Lapping zone in Beam

แชร์
ฝัง
  • เผยแพร่เมื่อ 31 ม.ค. 2025

ความคิดเห็น • 47

  • @watsonexalien3968
    @watsonexalien3968 4 ปีที่แล้ว +6

    Correct lecture according to what i've learned.

  • @kannansenthilkumar5229
    @kannansenthilkumar5229 4 ปีที่แล้ว +3

    Sir! Very good 👍 explanation for learner. This video is lapping zone between 2column.we are expect another video lapping zone between 4column (20Meter).tq,🙏🙏♥️♥️

  • @civilengineeringtolifeengi3333
    @civilengineeringtolifeengi3333 4 ปีที่แล้ว +2

    so nice of you , Clear explanation . Very well .

  • @kinleygyeltshen6494
    @kinleygyeltshen6494 3 ปีที่แล้ว

    I believe bottom beam main bar lapping is provided up to L/8 from the face of column is have been ban. Because during earthquake join of building face most stress. Like beam and column join.
    Lapping is provided 2d(d- effective depth of beam) away from face of column. So it is simple. We just need to add 2d + LD.
    If there are more numbers of bars. We just need to avoid midspan' s L/4 distance(L- effective span) and 2d from face of column and keep minimum of 1.3m distance between 2 center of lapping. If lapping length is 550mm. It's center would be 275mm, other rod's lapping should be provided 1.3m away. If we have started our first lap at 2d from face of column. Then next lap should be provided at 2d+275+1300 continue in same manner
    If it is not possible we should provide lapping between other other columns.

  • @drsl6209
    @drsl6209 ปีที่แล้ว

    Hi sir I look at video is very good In you say lapping length in beam is l x8 and one you say lx4 can you explain which one to use

  • @ImranHossain-rf1ou
    @ImranHossain-rf1ou 3 ปีที่แล้ว

    Thanks for give us very very important tropic.

  • @sukdebstory3035
    @sukdebstory3035 4 ปีที่แล้ว

    very nice sharing and very informative... thank you for sharing...

  • @muzafarahmad4128
    @muzafarahmad4128 4 ปีที่แล้ว +1

    Thanku sir for making these informative videos.

  • @gauravtrivedi9851
    @gauravtrivedi9851 2 ปีที่แล้ว

    Can we overlap extra bars

  • @phyohtetkoko929
    @phyohtetkoko929 3 ปีที่แล้ว

    Thanks For Teaching 👌🏻👍🏻✌🏻😊

  • @rudreshkumar4643
    @rudreshkumar4643 4 ปีที่แล้ว

    Thank you for understanding. Keep bringing new more topics like this. 🤗🤗🤗

  • @hassanhaider9651
    @hassanhaider9651 3 ปีที่แล้ว

    Sir if the lap in in the junction of columns? Will this be alright? In bottom bars

  • @Toonswithbabaji
    @Toonswithbabaji ปีที่แล้ว

    Hello sir what should be length of lapping near cantilever

  • @er.saddam9856
    @er.saddam9856 3 ปีที่แล้ว

    Sir you wrote lapping zone in bottom l/8 but you said l/4. Can u Clearrifing it will be help full for us.

  • @lismanpermana8218
    @lismanpermana8218 2 ปีที่แล้ว

    sir.. where is lapping zone for distribution / side face bars?

  • @paklahisap2646
    @paklahisap2646 3 ปีที่แล้ว

    Suppose if we cover the whole length of lapping zone. But we have the rod which we donot want to cut it. Can we continue

  • @paklahisap2646
    @paklahisap2646 3 ปีที่แล้ว

    In the other video you mentioned that lapping should not provide upon the column.

  • @loydfernandez5490
    @loydfernandez5490 3 ปีที่แล้ว

    Sir where is the safe splicing zone in suspended slab?

  • @travelexploring4259
    @travelexploring4259 4 ปีที่แล้ว

    Can u please mentioned the is code and clause of this ?

  • @chennareddyindla2349
    @chennareddyindla2349 4 ปีที่แล้ว

    Told the point directly .

  • @madhankumarm1910
    @madhankumarm1910 4 ปีที่แล้ว

    Sir video is not playing from 5:11 to 7:14
    Please fix this or
    Reupload this sir,.
    Your videos are helpful and informative

  • @maberikinstink9407
    @maberikinstink9407 3 ปีที่แล้ว

    what about the 2D from the face of the column?

  • @gladiatorgaming4840
    @gladiatorgaming4840 4 ปีที่แล้ว

    Please make one more video as the video got struck. Difficult to understand what is the formula

  • @inhinyerongsibil6383
    @inhinyerongsibil6383 4 ปีที่แล้ว

    well discussed.. next topic Construction Joints

  • @Rintu0007
    @Rintu0007 4 ปีที่แล้ว +2

    Helpful video but somewhere in the mid the video got stopped

  • @joseloturiano9532
    @joseloturiano9532 4 ปีที่แล้ว

    what is 1.3 as lapping length for slab

  • @royalpankaj9769
    @royalpankaj9769 3 ปีที่แล้ว

    well explained thank u bro

  • @richardneile.salalima54
    @richardneile.salalima54 10 หลายเดือนก่อน

    thank you sir

  • @samvignesh620
    @samvignesh620 3 ปีที่แล้ว

    Sir I have one doubt L/8 or L/3 where L is unit is meter or MM or feet

    • @arcanery6604
      @arcanery6604 3 ปีที่แล้ว +1

      In this example it's m so take m. If it's feet take feet and so on. When u divide something with a constant the unit remains unchanged haha. Basic.
      I hope this cleared ur doubt

  • @prabapolladhavan
    @prabapolladhavan 3 ปีที่แล้ว

    Kola mass

  • @yasarkhan672
    @yasarkhan672 4 ปีที่แล้ว

    Sir, where are you from??

  • @abdimuhaba9256
    @abdimuhaba9256 2 ปีที่แล้ว

    I appreciate you

  • @dr.alikhan2384
    @dr.alikhan2384 ปีที่แล้ว

    Dear tutor, it seems ur not getting expected viewers. Fir the following reasons.
    1st the board is not super white what ur writing or drawing can’t be seen. 2nd poor light which every one can’t see what is written. Ur well wisher.

  • @v-b9b
    @v-b9b 2 ปีที่แล้ว

    thank you

  • @udaykumar-pu8zf
    @udaykumar-pu8zf 4 ปีที่แล้ว

    sir lapping zone is best place in beam tensile zone in beam

  • @keshavamurthymn2939
    @keshavamurthymn2939 4 ปีที่แล้ว

    Excellent

  • @khansami8882
    @khansami8882 4 ปีที่แล้ว

    Thank you sir

  • @udaykumar-pu8zf
    @udaykumar-pu8zf 4 ปีที่แล้ว

    but teaching lapping zone at top of beam

  • @bijobabu9992
    @bijobabu9992 4 ปีที่แล้ว +1

    Sir video is stuck from 5:34 to 7:10

  • @gladiatorgaming4840
    @gladiatorgaming4840 4 ปีที่แล้ว

    Video stopped at mid