  • @arshadshaikh5632
    @arshadshaikh5632 24 วันที่ผ่านมา

    Sir, why dont we provide crank bent up bars in new mesh ...how will it resist negative bending moment if bent up bar is not provided in new mesh ???

  • @arshadshaikh5632
    @arshadshaikh5632 24 วันที่ผ่านมา

    And how can we know if slab is weak by positive bending moment or negative moment

  • @AdityaSingh-jn1kw
    @AdityaSingh-jn1kw 2 ปีที่แล้ว +1

    Thank u sir for this awesome lecture 🙏

    • @civilbasics21
      @civilbasics21  2 ปีที่แล้ว

      Thanks

    • @firozali4337
      @firozali4337 7 หลายเดือนก่อน

      Sir kya aap ka watsapp number milega

  • @subhashmedhi386
    @subhashmedhi386 หลายเดือนก่อน

    Sir, Is there any construction firm based in India specialised in providing such retrofitting services in Guwahati?

  • @haiderali-ey5rp
    @haiderali-ey5rp 2 ปีที่แล้ว

    Sir how to concrete it becuase we have no exposed surface to do it? please guide me

    • @civilbasics21
      @civilbasics21  2 ปีที่แล้ว

      It can be done by drilling holes in slab from the top at a suitable interval and pouring concrete into holes and using vibrator at the same time from top or bottom side by keeping some steel pannel open.

  • @sush6999
    @sush6999 3 ปีที่แล้ว

    For positive BM strengthening. How to place concrete after steel mesh is installed? Top slab is as it is so how can we pour the concrete at bottom of slab?

    • @civilbasics21
      @civilbasics21  3 ปีที่แล้ว

      This is typical job but not impossible. This can be done by pumping concrete from bottom. Complete bottom shuttering is not done,it is done in strips.when this strip is poured,another strip is fixed.
      Pouring concrete may be done by drilling holes at suitable interval in old slab and pouring fresh concrete by pumping into formwork.

    • @sush6999
      @sush6999 3 ปีที่แล้ว

      Sone Lal Sharma workability of concrete need to be check specifically so that the poured concrete should move horizontally

    • @civilbasics21
      @civilbasics21  3 ปีที่แล้ว

      Yes, special type of workable concrete is required for it.

    • @mcnakum7567
      @mcnakum7567 ปีที่แล้ว

      Can you tell me special type of workable concrete is which one?

    • @vinaykumaryadav5267
      @vinaykumaryadav5267 ปีที่แล้ว

      ​@@mcnakum7567 micro concrete