Manitowoc Ice - long harvest and T3 error

แชร์
ฝัง
  • เผยแพร่เมื่อ 14 ต.ค. 2024

ความคิดเห็น • 14

  • @al6347
    @al6347 7 หลายเดือนก่อน +2

    In the manual there is a procedure you can follow to troubleshoot the board
    Very easy

  • @justanoldhandyman
    @justanoldhandyman 7 หลายเดือนก่อน +1

    Way to go.👍

  • @davejohnsonnola1536
    @davejohnsonnola1536 7 หลายเดือนก่อน +1

    All too often hear " the thermistors don't affect operation".
    Seldom have heard why they are diagnostically important.
    I've attended annual official Manitowoc trainings and not heard that emphasized enough.

    • @restaurantrepairs
      @restaurantrepairs  7 หลายเดือนก่อน +2

      Without accurate data how can we diagnose?

    • @TeefMah
      @TeefMah 7 หลายเดือนก่อน +1

      I'm confused. What part of the units operation other than assisting diagnosis and throwing errors do the probes serve? I thought they don't actually do anything in terms of among ice?

    • @restaurantrepairs
      @restaurantrepairs  7 หลายเดือนก่อน

      @@TeefMahyour not confused you said it right. They only offer data. They don’t DO anything other than alert us to an issue if they’re working properly and make errors but if they fail it’s double useless.

  • @harrydickson4575
    @harrydickson4575 7 หลายเดือนก่อน +2

    👍👍👍

  • @garygordon37
    @garygordon37 26 วันที่ผ่านมา +1

    good day i has a manitowoc ice machine it drop ice then going into long harvest then after turning in off and on it makes ice then drop then goes back into long harvest. i replace the ice thickness probe the, the board and the problem still exist i tried what you explain in the video and still exist. what next can i tried

    • @restaurantrepairs
      @restaurantrepairs  26 วันที่ผ่านมา

      Sounds like it’s not recognizing the ice dropping. That’s a bad curtain switch.

    • @garygordon37
      @garygordon37 22 วันที่ผ่านมา +1

      i change the curtain switch and the issue still exist

    • @restaurantrepairs
      @restaurantrepairs  22 วันที่ผ่านมา

      it’s making ice and dropping the ice ? But showing long harvest? Long harvest means the curtain switch didn’t open (aka ice didn’t drop) or if it did the board didn’t recognize it. The end. Long harvest happens when the ice thickness probe says start a harvest…. The harvest valve initiates and then waits for the curtain switch to open to start a freeze again. The board should show a light indicating the curtain is closed so when you manually open it that light should go out. Check that.

  • @marquism2920
    @marquism2920 4 หลายเดือนก่อน +1

    How much is the service call on something of this nature

    • @restaurantrepairs
      @restaurantrepairs  4 หลายเดือนก่อน

      lol. Sorry for the weird reply. I thought this was on a different video. 😂. Labor hours are labor hours. Everyone’s different and it depends how efficient we find the issue and if we have the parts on the van or now. No simple answer to that question sadly.

    • @marquism2920
      @marquism2920 4 หลายเดือนก่อน +1

      Ok thank you for replying ​@restaurantrepairs