Good ET is also connected. My preference is 1U-5470 pressure group too for deep technical analysis. Well fuel pressure external gauge is your good choice too. 🇺🇲☺️🇵🇰😉
Cat makes best in class diesel generators but not a fan of any large nature gas gen sets. At the large hospital that I retired from we had three 2,000 KW CAT Diesel Gen sets that ran great ( 1800 RPM ). We had four natural gas CAT POS 2 760 KW Gen sets that even after major overhaul they had trouble running 650 to 700 KW of load banks especially during the summer. They both were same size & 16 cylinders but the natural gas only ran at 1,200 RPM due to they ran them in hot days to leak shave power. Had a CAT PIG POS 1,000 KW natural gas gen set in a high rise office building that would never shut down after monthly halve hour ATS testing. Told us the load was not high enough so it needs a load bank for it. ( YEP sounds like a BS story ).
When charges The resistors banks,Is a drop in rpn AND of course, frequency too. If the resistor banks are Huge, like 500 kilowatts or more the engine cant stay stable,because the load Is present in microseconds,so the drop Is present until rpm control systems actívate quickly for stay the frequency constant,AND voltage output too
I become chargeman with A4 skill and convert to B4 and PJ8 skill before 😝😝😝 same with this machine CAT brand high voltage.... one time i forget wear saftey glove the electric leak hit my screw 🪛 throw away like being kicked by horse 🐎😅 that only my experience before and by hand bump with dark blood inside.. not funny at all😑😑😐
Very huge ABB termomagnétic interruptor ( circuit breaker).
Sure Is 1600 or 2000 amp setting,or bigger
Very informative video thanks for sharing
Good ET is also connected. My preference is 1U-5470 pressure group too for deep technical analysis. Well fuel pressure external gauge is your good choice too. 🇺🇲☺️🇵🇰😉
Cat makes best in class diesel generators but not a fan of any large nature gas gen sets. At the large hospital that I retired from we had three 2,000 KW CAT Diesel Gen sets that ran great ( 1800 RPM ). We had four natural gas CAT POS 2
760 KW Gen sets that even after major overhaul they had trouble running 650 to 700 KW of load banks especially during the summer. They both were same size & 16 cylinders but the natural gas only ran at 1,200 RPM due to they ran them in hot days to leak shave power. Had a CAT PIG POS 1,000 KW natural gas gen set in a high rise office building that would never shut down after monthly halve hour ATS testing. Told us the load was not high enough so it needs a load bank for it. ( YEP sounds like a BS story ).
Ma Sha Allah. Good work. Keep it up.
Great Job
Thanks from #PowerLearningChannel
ما شاء الله
Hmmm Zahid Tractor KSA 🇺🇲☺️🇵🇰😉
Mr.khaled good job
Barley bogged it down
👍
استاذ خالد عندى نقص فى الزيت ...و عنديش اى بقع زيت...f30. 2015
Strange question could this run an hotel on emergency power
Easily
As salam aleykum
How I can contact with you
I'm looking to buy CAT generator machines
ممكن تليفونك لى التواصل ..
Frequency not stable RPM ok temperature is ok
When charges The resistors banks,Is a drop in rpn AND of course, frequency too. If the resistor banks are Huge, like 500 kilowatts or more the engine cant stay stable,because the load Is present in microseconds,so the drop Is present until rpm control systems actívate quickly for stay the frequency constant,AND voltage output too
I become chargeman with A4 skill and convert to B4 and PJ8 skill before 😝😝😝 same with this machine CAT brand high voltage.... one time i forget wear saftey glove the electric leak hit my screw 🪛 throw away like being kicked by horse 🐎😅 that only my experience before and by hand bump with dark blood inside.. not funny at all😑😑😐