Oddly Satisfying Electric Wires Installation | DIY Project

แชร์
ฝัง
  • เผยแพร่เมื่อ 19 พ.ย. 2022
  • Explore a wide variety of content in our carefully curated TH-cam playlist: • Binge-Worthy Content
    If you’re enjoying this video, check out our other projects! Subscribe to our channel for woodturning, metalworking, restorations, remakes, epoxy resin projects and more. You name it, we do it!
    Subscribe to our channel → / totallyhandy
    Check our Shorts channel → / totallyhandyshorts
    #totallyhandy
  • แนวปฏิบัติและการใช้ชีวิต

ความคิดเห็น • 529

  • @TotallyHandy
    @TotallyHandy  ปีที่แล้ว +28

    🌘🌘🌘 Check out our other video HERE: th-cam.com/video/cSPv09O2zts/w-d-xo.html

    • @sandipmishra2178
      @sandipmishra2178 ปีที่แล้ว +2

      Ll I have to pay the one I like Tarak chocolate o let us look diffrent to card and

    • @claudeleondiatta9602
      @claudeleondiatta9602 ปีที่แล้ว +1

      😊😊

    • @AthulaBroElectrical
      @AthulaBroElectrical 7 หลายเดือนก่อน +1

      Ask me anything about house wiring. Thanks and best regards

    • @user-et3ij4ne8n
      @user-et3ij4ne8n หลายเดือนก่อน

      .❤❤😂😢 ‏‪2:08‬‏ ​

  • @danieljunge5522
    @danieljunge5522 ปีที่แล้ว +478

    As an electrician I'm crying to see that many mistakes at once

    • @jacksonroad9263
      @jacksonroad9263 ปีที่แล้ว +21

      as a handyman im laughing at the video too

    • @kaijnk
      @kaijnk ปีที่แล้ว +10

      Ha ha ha. Sorry for home owner.

    • @fletrcarr
      @fletrcarr ปีที่แล้ว +5

      Hahaha me too😂

    • @Zpoody
      @Zpoody ปีที่แล้ว +3

      I have to agree.

    • @danilomanrique3853
      @danilomanrique3853 ปีที่แล้ว +6

      at least he used conectors 😂

  • @MultiKlompen
    @MultiKlompen ปีที่แล้ว +98

    0:39
    NO! Never cut it that short!! Never!

    • @jacklancer8317
      @jacklancer8317 ปีที่แล้ว +5

      I'm curious as to why you say that?

    • @FXArts
      @FXArts 9 หลายเดือนก่อน

      Why please?

    • @eisenklad
      @eisenklad 8 หลายเดือนก่อน +5

      @@FXArts in case you need to add more breakers or replace a faulty breaker.
      during such scenarios, the electrician will cut off the ends because its already weakened during installation. if the core of the wire(the copper) breaks, a small arc may occur in the wire and lead to a fire.
      if a wire is short, one will have to use more connectors to extend existing wires but its not great( more point of failures)
      alternative is to run a new wire(costly and time consuming)

    • @FXArts
      @FXArts 8 หลายเดือนก่อน

      @@eisenklad Thanks

    • @IAmThe_RA
      @IAmThe_RA 4 หลายเดือนก่อน

      ​@@FXArtsAnd this board cannot fit RCBOs because he cut the wires so short especially the blue wires (neutrals). Unlike MCBs, RCBOs need both the phase and neutral of the circuit to go in its phase and neutral terminals (output).

  • @ranugsielprep1550
    @ranugsielprep1550 ปีที่แล้ว +173

    The cable cross-sections for the supply of the automatic circuit breakers (above) are wrong. In Germany there are 3-pin prefabricated copper bridges for this. The blue wires for the N busbar have been cut too short without any reason. There should be more reserve loop behind the circuit breaker. While the work looks good, it is technically critical.

    • @MilanTheMan69
      @MilanTheMan69 ปีที่แล้ว +3

      5:55
      Lol 😅

    • @jacksonroad9263
      @jacksonroad9263 ปีที่แล้ว +5

      as a handyman those are the wrong wires for the switch board. good luck running more than 30amps

    • @psatyanarayana3686
      @psatyanarayana3686 ปีที่แล้ว

      @@MilanTheMan69 .

    • @ioanmariusbozga
      @ioanmariusbozga ปีที่แล้ว

      6kw

    • @Devviiiii
      @Devviiiii ปีที่แล้ว

      And its a C10A and after that a B16, love that, short circuit failures will always trigger the C10 and you never now, which circuit it was. and all the other brakers are wired with live wire instead of all of them with the same load....

  • @alewhitesnake
    @alewhitesnake ปีที่แล้ว +102

    Beautiful job, but:
    - wire diameters are certainly not correct
    - feeding the breakers by jumping wires isn't the best solution at all
    - you should use wire terminals for the connections
    This video is actually teaching how to set your circuit on fire. At least it's a beautiful circuit.

    • @ljubomirculibrk4097
      @ljubomirculibrk4097 ปีที่แล้ว +1

      There are nice insulated thick coper flat rails, no chance of arcing or owerload.

    • @nowonmetube
      @nowonmetube ปีที่แล้ว +2

      Guys I'm lost. People put electrical installation videos online and there's always someone who says people put things on fire. It works though. So what are they on about? Does it work or cause fires or what? Also please don't use too many technical terms, I don't understand everything.

    • @DB4KK
      @DB4KK ปีที่แล้ว +2

      @@nowonmetube if a circuit pulls too much amperage, it can cause immense heating of certain gauge wires. A thicker gauge wire means more amperage.

    • @DB4KK
      @DB4KK ปีที่แล้ว +7

      @@nowonmetube jumping wires on a breaker is also not a great idea, buss bars a more commonly used

    • @andrasbradacs6016
      @andrasbradacs6016 ปีที่แล้ว +7

      @@nowonmetube Add up all the amperages to the first jumperwire next to the first breaker and you will know why is not a great idea to use jumperwires…

  • @darraghljordan3259
    @darraghljordan3259 ปีที่แล้ว +11

    Tks for showing us the propper way to start a fire

  • @kostadinkostadinow9319
    @kostadinkostadinow9319 ปีที่แล้ว +31

    Having 3 phase power but using only the closest phase. Totally handy to set your house on fire...

  • @gabriellando1
    @gabriellando1 11 หลายเดือนก่อน +19

    As an electrician engineer, I'm catching fire right now.

  • @grannywaffle
    @grannywaffle ปีที่แล้ว +11

    1:53 wwooooaaah hold up there sonny Jim, did you just link all the breakers for the property in 1.5mm? Toasty 😂

    • @darraghljordan3259
      @darraghljordan3259 ปีที่แล้ว +1

      He was trying to make a heater😂

    • @DavidKbst
      @DavidKbst 6 หลายเดือนก่อน

      ​​@@darraghljordan3259Hi, can you please explain me this? Why si more current on the jumper near supply on the right side?

    • @tristan6509
      @tristan6509 3 หลายเดือนก่อน +1

      ​@@DavidKbsthe's putting the load of every breaker in that row through a single 1.5mm wire...

  • @cristianjrojas
    @cristianjrojas ปีที่แล้ว +58

    That electric panel looks very dangerous, one thin wire to power every circuit?

    • @patrickcannell2258
      @patrickcannell2258 ปีที่แล้ว +13

      Not compliant at all. DIN busbar is correct covered by a 63A main. This board is a fire 🔥 looking for a time to happen!

    • @PedroFaria
      @PedroFaria ปีที่แล้ว +3

      Maybe it's an example of how it should be layed out and connected and not about the power and amps. At the end he turns on a bunch OU lights that, being LED and at 240v, 1,5mm2 wires are plenty. Xp

    • @afcl1984
      @afcl1984 ปีที่แล้ว +7

      Jesus, putting a board example like this online... Totally wrong.

  • @Fatpumpumlovah2
    @Fatpumpumlovah2 19 วันที่ผ่านมา +1

    THIS VIDEO NEEDS MASS REPORTING FOR HARMFUL AND DANGEROUS ACTS!!!

  • @rhysferris1996
    @rhysferris1996 ปีที่แล้ว +8

    And this is why (In the UK at least) a consumer Unit has to be installed by a qualified electrician. You won’t get a installation certificate or a satisfactory EICR because this consumer unit is just a fire hazard. I don’t think an EICR has enough space to list the issues with this install. I am not yet fully qualified and I can see many issues with this install.

  • @barrydonnelly4790
    @barrydonnelly4790 ปีที่แล้ว +7

    Jaysus you're putting some faith in them 1.5 or 2.5 singles linking your breakers 🤣

  • @Fuck__Russia
    @Fuck__Russia ปีที่แล้ว +42

    1:42 - Those repeated single brown wire bridges on top of the circuit breakers should be avoided at all cost, because the nearer the bridge to the supply spot, the more current. In a nutshell, a 1.5mm² wire supplies a dozen circuit breakers. This is insane.

    • @user-tg2rj2rj5n
      @user-tg2rj2rj5n ปีที่แล้ว

      На перемычки нет нагрузки,я подобные щиты собирал и каждый год провожу осмотр,всё в порядке

    • @evgeneevgen8177
      @evgeneevgen8177 10 หลายเดือนก่อน

      @@user-tg2rj2rj5nну если в квартире где две лампочки и один чайник то можно и так😂😂😂😂😂хотя еслибы мне собрали такое говно как этот щит я бы просто не заплатил за такую работу😂

    • @IAmThe_RA
      @IAmThe_RA 7 หลายเดือนก่อน

      I think those are 2.5mm² conductors. This is probably dutch electrics, i think i was told by some that in netherlands they use 2.5mm² conductors for both lighting and power circuits, smaller conductors are not allowed.

    • @DavidKbst
      @DavidKbst 6 หลายเดือนก่อน

      Hi. Can you explain me why is near the supply spot more current? Why not on the left side?

    • @Odisovic
      @Odisovic 2 หลายเดือนก่อน

      it depends on the project documentation, where the designer has specified for what output load he has designed the switchboard.
      Even in Slovakia it is true that you do not design for the maximum, but for the operation that is expected.
      So to say it is wrong is nonsense, if you are serious and you look at the manufacturers products, if one bridge is for 63A and another for 80A, which one would you put?
      If you don't know what's in the project documentation, then to jump to conclusions that something is wrong shows more likely that you have no idea what you're talking about and are just a "screwdriver user" and not an electrician ;)

  • @Ytofmayachev
    @Ytofmayachev ปีที่แล้ว +17

    Make sure to ask to an electrician which cross section to use before DIYing, i beg all the watchers. White the edit of the video is great, the way the materials are chosen and assembled is beyond dangerous, especially in the electrical board part.

    • @Dobai1
      @Dobai1 ปีที่แล้ว +1

      Formula for that is pretty simple, you multiply the section area of the conductor with 7 Amps/mm2 and there you have it. 10.5 Amps for 1.5 mm2 conductor, 17.5 Amps for 2.5 mm2. What goes above 4 mm2 is calculated with a different formula. But it can withold around 9KWh in continuous consumption.

    • @Ytofmayachev
      @Ytofmayachev ปีที่แล้ว +3

      @@Dobai1 I am an electrician.
      This formula doesn't account for tension loss over lenght or short circuit values, which are absolutly necessary for a stable and secure installation.
      While there are ways to circumvent those problems without changing the cross section of a cable, it feels safer to encourage talking to an electrician for tips especially in a comment section.

    • @IAmThe_RA
      @IAmThe_RA 7 หลายเดือนก่อน

      ​@@Ytofmayachev The biggest wire used in this distribution board looks like 2.5mm². I hope the main isolator switch has a 16A fuse otherwise this whole installation is a fire hazard. Standard is on the floor. What country is this?

  • @Lee-xs4dj
    @Lee-xs4dj ปีที่แล้ว +7

    Let's just hope the input tails are covered by a 12amp breaker on this board

  • @user-el6ht7xo9i
    @user-el6ht7xo9i ปีที่แล้ว +3

    Руки бы оторвать за такую работу

  • @West_Kootenay_railfan
    @West_Kootenay_railfan ปีที่แล้ว +4

    9:49 There's a thing called a wood burner you can buy for cheap instead of burning your house down by messing with 120 or 240 ac or 340 ac depending where you live.

    • @evgeneevgen8177
      @evgeneevgen8177 10 หลายเดือนก่อน

      U re right, this panel simply awful

  • @user-ug2hy4ti3t
    @user-ug2hy4ti3t ปีที่แล้ว +9

    По ПУЭ должен быть запас провода как минимум на ещё одно подключение,тут как то в обрез совсем...

    • @user-nu2su1tn2u
      @user-nu2su1tn2u ปีที่แล้ว +1

      Блин тебя только это смущает?

  • @electromag95
    @electromag95 ปีที่แล้ว +3

    Когда ещё не было в каждом магазине гребенок, соединяли АВ с помощью перемычек. Только делали перемычку неразрывной.

  • @lasphalteur
    @lasphalteur ปีที่แล้ว +5

    Fire in 3…..2…..1…..🔥

  • @taimoorshah8230
    @taimoorshah8230 ปีที่แล้ว +10

    never use a wire to jump circuit breakers. its insane how thin the wire is which he used without thinking twice.

  • @oleksandrponomarov2437
    @oleksandrponomarov2437 ปีที่แล้ว +7

    На 1:48 где куча перемычек на фазу. Такие делать нельзя. Нужно использовать либо перемычки из более толстого провода, либо специальную шину. Если делать как на видео, при мах нагрузке на все автоматы, соединенные такими перемычками, сгорят первые (справа) перемычки.

    • @user-rn5cl9zw1g
      @user-rn5cl9zw1g ปีที่แล้ว

      А я уже думал,что только меня смутило сечение провода на перемычки) Но судя по номиналам этот щит исключительно на освещение,и каждый автомат питает отдельную лампочку)

    • @user-qh6kp5lz1b
      @user-qh6kp5lz1b 9 หลายเดือนก่อน

      Нужно использовать сечение провода который будет вывозить суммарный ампераж всех соединённых автоматов? А в чем еще плох этот электрощит?

    • @DavidKbst
      @DavidKbst 6 หลายเดือนก่อน

      Hi. Can you expain me please why jumper on the right start fire? Why not jumper on the left?

  • @ZloySok
    @ZloySok ปีที่แล้ว +1

    Сразу видно профи за работой.....
    1. Оболочку кабеля режет ножом.
    2. Подозрительно тонкое сечение кабеля на групповые автоматы. Да и вводной кабель тоже странный учитывая количество автоматов.
    3. Перемычки короткими обрезками. Если готовые шины еще не выучил, сделай хотя бы цельным отрезком провода,а не огрызками.
    4. клещи для зачистки нужно другие( именно эта модель плохая, есть лучше варианты), они изоляцию портят, как зубами кусали.

  • @user-fo5is8dt2j
    @user-fo5is8dt2j ปีที่แล้ว +7

    Это видео о том, как не надо делать. Нельзя делать перемычки кабелем того же сечения.

    • @user-nb9mk5le2c
      @user-nb9mk5le2c ปีที่แล้ว

      Перемычки то он сделал по правилам - того же свечения что и кабель ввода - а вот он - кабель ввода - заниженного сечения

    • @user-fo5is8dt2j
      @user-fo5is8dt2j ปีที่แล้ว

      @@user-nb9mk5le2c нет. Явно перемычки сделаны тем же кабелем, что и разводка. Перемычки в принципе колхоз.

  • @Fuck__Russia
    @Fuck__Russia ปีที่แล้ว +17

    You're using only phase #1, you must balance load across the 3 lines...

    • @MetalMilitia7771
      @MetalMilitia7771 ปีที่แล้ว

      It depends in some countryes you have available only one phase for home instalations

    • @panosassos788
      @panosassos788 ปีที่แล้ว +3

      @@MetalMilitia7771 he has 3 phases here, uses 3phases RCD and uses only one small bridge of 1,5mm for all his house. Do this and dont wonder why your house is smoking one day

  • @guffermeister
    @guffermeister ปีที่แล้ว +11

    Why run three phase to the unit and only use one of it? Why type C breakers? These have much more stringent Zs readings to ensure they trip in time - a problem if you have long cable runs at times. Only usually required if you have high inrush situations that would cause a B type to trip too easily

    • @AthulaBroElectrical
      @AthulaBroElectrical 7 หลายเดือนก่อน

      Ask me anything about house wiring. Thanks and best regards

    • @IAmThe_RA
      @IAmThe_RA 7 หลายเดือนก่อน

      Type c is the most common in the world. As far as i know only the UK where type B is common.

  • @user-ip5ud4nd2h
    @user-ip5ud4nd2h ปีที่แล้ว +6

    Запаса вообще не оставляешь, как это потом ремонтировать если сгорит?

  • @afonsobatistadealmeidaalme3798
    @afonsobatistadealmeidaalme3798 ปีที่แล้ว

    Eu adoro fazer escalações muito bom está de parabéns

  • @reedy8585
    @reedy8585 ปีที่แล้ว +3

    Using single wire jumpers to feed the breakers is a fire hazard as you have overloaded the wire you should be using a bus bar rated for the supply usually 100 amps

  • @kolobok2440
    @kolobok2440 7 หลายเดือนก่อน

    Граждане специалисты - еврофанатики супер - пупер любители устанавливать кучу всяких узо , напряженческих реле и расцепителей, учитесь делать щитки так же просто , красиво и надежно!!!

  • @romycruz4498
    @romycruz4498 6 หลายเดือนก่อน

    now, that's the way it should be. excellent !

  • @mananraval3506
    @mananraval3506 ปีที่แล้ว +1

    I Am from India. I am Electrisian.
    Electrical Distribution box Connections method is good but all M.C.B's incoming power wire link connect MCB's Down terminal not up Terminal. As per my knowledge.

  • @user-rv9co5ll9i
    @user-rv9co5ll9i ปีที่แล้ว +6

    Перемычки выполнены каким сечением? 1,5 мм2?

    • @user-xr4wh2rn3w
      @user-xr4wh2rn3w ปีที่แล้ว

      Больше в видео нечего не смутило?)))

    • @user-rv9co5ll9i
      @user-rv9co5ll9i ปีที่แล้ว

      @@user-xr4wh2rn3w хотя бы на этот вопрос ответ получить бы)))

  • @one.tap.-2667
    @one.tap.-2667 ปีที่แล้ว +2

    The First Clip: U can run to the jail when u Do it like that. .... Normaly u use a 10qmm Phasenschiene

  • @user-tw4tg9ir5p
    @user-tw4tg9ir5p ปีที่แล้ว +2

    Всё красиво где запас провода!

  • @sr.navarro7859
    @sr.navarro7859 ปีที่แล้ว +2

    Ese cuadro eléctrico en España incumple toda la normativa de seguridad

  • @leonnegro4226
    @leonnegro4226 6 หลายเดือนก่อน +1

    Guau. Que país será ese que todavía siguen usando conductores de 1 solo hilo. Es prehistórico. Será algún país del tercer mundo.
    Saludos cordiales.

  • @aleksandrmozgovoy1167
    @aleksandrmozgovoy1167 ปีที่แล้ว +3

    Перемычки вместо гребёнки)))

    • @user-jg4bu8iz4d
      @user-jg4bu8iz4d ปีที่แล้ว

      Ага , а сечение видел? )))

  • @technics6215
    @technics6215 9 หลายเดือนก่อน

    I became electrican because electrical equipment is soooo cool :)

  • @cristogil4537
    @cristogil4537 ปีที่แล้ว +1

    Ese cable tan fino trae la derivación individual al cuadro

  • @Grigory_Protsuk
    @Grigory_Protsuk ปีที่แล้ว +9

    Перемычки на автоматах зло, есть фазная шина, нет запаса в проводах на второе подключение к автомату, ншви на многожилку обязательно, сечение проводов в щите подозрительно мало

    • @santoz71
      @santoz71 ปีที่แล้ว +2

      шина медная есть на это дело

  • @ricardomoraes8874
    @ricardomoraes8874 ปีที่แล้ว +2

    Deixou sem recurso pra manutenções... fios muito curtos. Derivou tudo de uma única fase... e não entendi pra que pôs dois disjuntores trifásico em série

  • @Sanya231986
    @Sanya231986 ปีที่แล้ว +5

    У меня все сжалось когда он над ладонью начал прорезать оболочку кабаля🤔🙄

    • @alekssamsonov5722
      @alekssamsonov5722 ปีที่แล้ว

      Я тоже думал, что кровищи не избежать! Повезло парню!)

    • @santoz71
      @santoz71 ปีที่แล้ว +1

      есть нож с лопаткой спецовый.

    • @Anisimov_Yu_M
      @Anisimov_Yu_M ปีที่แล้ว

      да, кабель жалко

  • @sanvigameing1082
    @sanvigameing1082 ปีที่แล้ว +1

    First video me apne Jo cutter use Kiya h , available hai ky meko chahiye

  • @marcelo_rcosta
    @marcelo_rcosta 2 หลายเดือนก่อน

    1:45 o serviço ensina a trabalhar.
    Excelente montagem!
    Lembra da primeira que fez?
    Quantos erros.
    Quanto tempo levou.
    Não ficou uma obra de arte como essa.
    A prática leva à perfeição.

  • @deusdetefranciscodesouza8099
    @deusdetefranciscodesouza8099 ปีที่แล้ว +4

    Quando a pessoa tem o dom de fazer bem feito ele já vem de berço parabéns 🎉🎉🎉

  • @dimasemilov7426
    @dimasemilov7426 7 หลายเดือนก่อน +1

    Всегда бы с такими проводами работать в щите!

  • @eisenklad
    @eisenklad 8 หลายเดือนก่อน

    alternative title: if you do this, dont expect Fire Insurance to cover your home

  • @dapxdap110
    @dapxdap110 7 หลายเดือนก่อน +2

    Какой смысл ставить пакетник на 16a и за ним на калдую линию 16A?

  • @gino2465
    @gino2465 ปีที่แล้ว +1

    That's a lovely job, bit confused to see all those wires tightly packed together in the conduit.

    • @BigHunt206
      @BigHunt206 ปีที่แล้ว +4

      It's Alot easier than you think, he actually made many mistakes.

  • @user-sb1un4hk4u
    @user-sb1un4hk4u ปีที่แล้ว +2

    Перемычкой в шкафу должны выполняться диаметром побольше. Иначе пожар!!!

    • @stariyhopper
      @stariyhopper ปีที่แล้ว

      Вообще лучше ставить шину а не экономить.

  • @firozmulla4512
    @firozmulla4512 ปีที่แล้ว +1

    Superb........

  • @mariusreit305
    @mariusreit305 ปีที่แล้ว +2

    La coupure unipolaire est interdite en France, vous devez couper la phase et le neutre en même temps

  • @philippeberenger257
    @philippeberenger257 หลายเดือนก่อน

    Complètement illégal en Europe !!!

  • @ta3aloumsat
    @ta3aloumsat ปีที่แล้ว +1

    تحياتي اخي الكريم من قناة تعلوم سات تحياتي

  • @sanatbekegambergenov7559
    @sanatbekegambergenov7559 ปีที่แล้ว +1

    Very good jobs

  • @user-wl9gv7tj8m
    @user-wl9gv7tj8m ปีที่แล้ว +1

    Извенити НО Вы допустили ошибку:1)-перемычки с разрывом,2)-перемычки вообще не должно быть

  • @user-zt7bc7hd5o
    @user-zt7bc7hd5o ปีที่แล้ว

    Yes it's beautiful. but we can break our hands for this

  • @MF-kk2cj
    @MF-kk2cj ปีที่แล้ว +1

    good skills

  • @JamesBrown-rm2rd
    @JamesBrown-rm2rd ปีที่แล้ว +2

    unless they are low voltage, I would never run wires underneath, a buse bare or breaker bars, if the breaker should go bad and heat up the wires are right behind them,but whatever make your movie.

  • @NurulIslam-uc9ic
    @NurulIslam-uc9ic ปีที่แล้ว +1

    Nice

  • @amabsalom251
    @amabsalom251 ปีที่แล้ว +1

    good job

  • @electrokomtech1441
    @electrokomtech1441 9 หลายเดือนก่อน +2

    It's cool,but Don cut too short ,ensure there is some allowance for maintenance in cable part,overall it's cool

  • @user-nn4lh4wn9q
    @user-nn4lh4wn9q ปีที่แล้ว +2

    Удвоивайте провода,вы собирайте не верно,так нету площадь прикосновение и всё будет перегореть

  • @HristovRumen
    @HristovRumen ปีที่แล้ว +3

    Unless all of these wires are powering lights of equal load size, this would be insane to wire like that without tracing and labeling each wire. That's a lot of lights, if they are indeed all lights. Hopefully, they're all 5W led's as otherwise, you wouldn't want to have all of them on, or your bridge power feeds between the breakers will soon be all melted.

  • @philopatepataphil6696
    @philopatepataphil6696 ปีที่แล้ว +1

    Type de branchement qui ne se fait plus en France car la coupure est unipolaire donc dangereuse. Ce type de branchement est interdit depuis plus de 40 ans en France. Peut être est ce du au régime de neutre. Dans ce cas il faudrait le préciser.

  • @user-ed1ew6qv1d
    @user-ed1ew6qv1d 3 หลายเดือนก่อน

    Since the MCBs Miniature Circuit Breakers have different rating, you could have utilized busbar to connect between them much more better. Jumper cables with the some cross sectional area are not safe.

  • @rmhanseniii
    @rmhanseniii 2 หลายเดือนก่อน

    The jokes on us because we’re all watching this hack

  • @DestroyerSTK
    @DestroyerSTK ปีที่แล้ว +8

    То самое чувство, когда нагружают 1 фазу из 3-х, а остальные НОЛЬ нагрузки! Такому электрику нужно на "булках" межфазку сделать...

    • @KOJIXO3NICK
      @KOJIXO3NICK ปีที่แล้ว

      Ага, а ещё он, о Боже, канцелярским ножом кабель зачищает и запас по длине жил маленький 😁

    • @user-sk3xl3js3t
      @user-sk3xl3js3t ปีที่แล้ว

      А это нормально, что он на медный провод обжимки из другого металла использует? Что это за металл, можете подсказать? Это допустимо?

    • @user-pd4ke6gk1t
      @user-pd4ke6gk1t ปีที่แล้ว

      Я думал по феншую, так себе сделал

    • @dimondiablo9644
      @dimondiablo9644 ปีที่แล้ว +1

      @@user-sk3xl3js3t это луженая медь

    • @user-sk3xl3js3t
      @user-sk3xl3js3t ปีที่แล้ว

      @@dimondiablo9644 спасибо за ответ!

  • @user-wp4dy9bz7t
    @user-wp4dy9bz7t ปีที่แล้ว +2

    Где маркировка проводов? Или все равно в какой автомат и что пихать? Ну а вишенка на торте, это перемычки!!! Ты купил щит, купил провода и автоматы, а на шину денег не осталось!!!! У тебя вроде изолированный приличный инструмент. Но перемычки это конец.

  • @gervaziovieira9764
    @gervaziovieira9764 ปีที่แล้ว +1

    Very good.

  • @rams5474
    @rams5474 ปีที่แล้ว

    Things are connected with art. Eating comes with design colour appealing and patterns. So also wiring with a design and art concept is really a job satisfaction. Self interest in any work is primary. Even in corporate they go for design and chart rather than numerical statistics report.

  • @aderoyrenaldo
    @aderoyrenaldo ปีที่แล้ว +1

    0:02 😢😢 careful with the razor bro dont do like that bro

  • @Mijgan
    @Mijgan ปีที่แล้ว +1

    Закручивать винты контрольской, тру качество

  • @elassrimohammed5600
    @elassrimohammed5600 ปีที่แล้ว +2

    Pravo,
    👍👍👍👍👍👍🇭🇺🇲🇦🌹🌹🌹🌹🌹🌹🌹

  • @rogeriomauricio9946
    @rogeriomauricio9946 ปีที่แล้ว +4

    Canal, parabéns! Estamos vendo que o profissional para ser bom tem que ter o dom. SHOW!

  • @edilsonjesus-yl9ne
    @edilsonjesus-yl9ne ปีที่แล้ว +1

    Bom parabens ótimo bom

  • @alexdiver9809
    @alexdiver9809 10 วันที่ผ่านมา

    Отличное видео КАК НЕЛЬЗЯ ДЕЛАТЬ.

  • @cheryljason9617
    @cheryljason9617 ปีที่แล้ว +5

    Only thing satisfying is it ended that music... nice clean job especially for a younger generation electrician... I'm a electrician of 25 years in America either way that's one of the cleanest panels I've seen

    • @tukituki9537
      @tukituki9537 ปีที่แล้ว +3

      Please, STOP working, if you like it

  • @1.hturmgewer
    @1.hturmgewer ปีที่แล้ว +2

    Запаса провода не оставлено, одноразовая сборка не ремонтно пригодна. Сечение питающего кабеля маловато.

  • @mamoun16
    @mamoun16 ปีที่แล้ว +1

    Nice, but not safety, very hazard if any electric leak

  • @spsaravanan3605
    @spsaravanan3605 ปีที่แล้ว

    Vera level Mass 👍

  • @user-cb1lu6wl8x
    @user-cb1lu6wl8x ปีที่แล้ว +1

    Так и думал что столько стоумовых электриков соберётся, как раньше жили? у меня дом 50 лет, всё на скрутках, менял проводку сам по простому на скрутках, без разводил электриков, а то они без штанов оставят, так вот скрутки как новые были, а сейчас чуть ли автомат на автомат надо ставить и ещё третьим подстраховаться.

  • @francescoinnamorati9591
    @francescoinnamorati9591 ปีที่แล้ว +1

    Se questo lavoro di cablaggio si faceva alle scuole professionali...

  • @noelbyrne8735
    @noelbyrne8735 ปีที่แล้ว +1

    Where to start with the oh so many mistakes made here. I’ll mention one, a very basic lesson learned on the job and in trade school. A single termination of a solid core copper wire should be folded over, especially when being terminated into such a large terminal like an MCB.

  • @aliahmedjan1135
    @aliahmedjan1135 ปีที่แล้ว +1

    I like your good joob

  • @KG-gg8rl
    @KG-gg8rl ปีที่แล้ว +1

    I have no idea what you are doing - could be incredibly dangerous for all I know? But it looks lovely.

  • @sprivet
    @sprivet ปีที่แล้ว +2

    В НШВИ провода нельзя скручивать перед обжимной

  • @Azoma78
    @Azoma78 ปีที่แล้ว

    Столько автоматов на одну фазу, остальные две отдыхают 😂

  • @1.hturmgewer
    @1.hturmgewer ปีที่แล้ว +2

    Интересная зажигалка!

  • @Tselectricals
    @Tselectricals 8 หลายเดือนก่อน

    Very nice presentation bhai ❤❤❤❤❤❤❤❤

  • @CreativeIdeasMaker
    @CreativeIdeasMaker ปีที่แล้ว +2

    Every time we watch your videos, we find interesting educational tips and get energy from watching you.

  • @rishirajupadhyay1704
    @rishirajupadhyay1704 ปีที่แล้ว

    With that much detailing I was expecting to see an artwork of someone's face or something. Still pretty cool though. :P

  • @TheCodr9
    @TheCodr9 หลายเดือนก่อน

    Can you use that setup on L1 and L2 mains?

  • @obaidulrahman3685
    @obaidulrahman3685 ปีที่แล้ว +1

    Good video.More video new

  • @BangMandor46
    @BangMandor46 ปีที่แล้ว

    Good very good amazing thank for your

  • @zakariagansagne6073
    @zakariagansagne6073 6 หลายเดือนก่อน

    Magnifique 😊

  • @AntonyoKnight
    @AntonyoKnight ปีที่แล้ว +1

    It's nonsense. Just an oddly satisfying video and a dangerous installation...

  • @abangayakubu5663
    @abangayakubu5663 5 หลายเดือนก่อน

    VERY GOOD BUT NEXT TIME INDICATE THE NAMES OF THE EQUIPMENTS AND DEVICES THAT YOU U USED