Generator lockout,fail to start and fail to crank due to oil sw and sensor?problem solve benzblogs

แชร์
ฝัง
  • เผยแพร่เมื่อ 5 ก.ย. 2024
  • Generator lockout due to multiple alarms without fixing now in this v'log we are going to talk about it how we make it correct trough program and simple explanation.

ความคิดเห็น • 248

  • @piecies_03_44
    @piecies_03_44 3 ปีที่แล้ว

    Boss automotive electrical Po Ako nong nkita ko yong vlog mo ang lupit nkakachallenge maa matuto pa thank you to your vlog boss sa katulad Namin maliliit na technician malaking tulong from Davao city Philippines God bless you boss

    • @benzblogsVlogs
      @benzblogsVlogs  3 ปีที่แล้ว +1

      Salamat sir im here to help bless more keepsafe

  • @inocenelson1943
    @inocenelson1943 2 ปีที่แล้ว +1

    I find your presentation very constructive and helpfull👍

  • @orimtonoi154
    @orimtonoi154 2 หลายเดือนก่อน

    thank you very much .I'm watching from Papua new Guinea.

  • @mohameddeik9556
    @mohameddeik9556 3 ปีที่แล้ว +1

    thank you eng for your explaining the best way.. please make us video how to do schedule perventive maintenance for generators in order to protect them

    • @benzblogsVlogs
      @benzblogsVlogs  3 ปีที่แล้ว

      Ok sir copy

    • @benzblogsVlogs
      @benzblogsVlogs  2 ปีที่แล้ว

      Preventive maintainance should be first 250 running hours and thin 500 for prome generator id standby it should be 1000-1500running hrs

  • @larzvlogag5027
    @larzvlogag5027 3 ปีที่แล้ว

    Very interesting, i learned more from this clip! Thanks for sharing master.. Replay ko uli ito sa ibang araw para makabisado ko..

  • @arifzafar9026
    @arifzafar9026 5 หลายเดือนก่อน

    Thanks buddy for sharing such good knowledge for generator troubleshooting but you are congratulations these things can't seen due shadow..

    • @arifzafar9026
      @arifzafar9026 5 หลายเดือนก่อน

      Dear may I know you where are you working?

    • @benzblogsVlogs
      @benzblogsVlogs  5 หลายเดือนก่อน

      Im working in dubai how about you?

    • @arifzafar9026
      @arifzafar9026 5 หลายเดือนก่อน

      @@benzblogsVlogs I'm good working in Dubai.. right now I'm looking your video low and under frequency but I can't see how to congratulation..

    • @benzblogsVlogs
      @benzblogsVlogs  5 หลายเดือนก่อน

      @@arifzafar9026 ok thank you

    • @benzblogsVlogs
      @benzblogsVlogs  5 หลายเดือนก่อน

      If you have under frequency this ither voltage is love just adjust in avr

  • @kookiddi3662
    @kookiddi3662 8 หลายเดือนก่อน

    Thanks for your valuable information.
    The video is really very helpful.

  • @jaykesapalaran5434
    @jaykesapalaran5434 2 ปีที่แล้ว

    Salamat sa PAG share ng knowledge mo Po sir.

  • @htcofficial8788
    @htcofficial8788 2 ปีที่แล้ว +2

    thank you for the videos godbless

  • @jrabot2035
    @jrabot2035 2 ปีที่แล้ว

    Salamat sir very informative tutorial videos

  • @rhodlomboydubailife7871
    @rhodlomboydubailife7871 3 ปีที่แล้ว

    here my support benz vlog tamsak done.. keep it up..

  • @nonoytv1740
    @nonoytv1740 3 ปีที่แล้ว

    thanks for idea sir, baka pwd ka request sir video for correct PMS for genrators..thanks in advance.

    • @benzblogsVlogs
      @benzblogsVlogs  3 ปีที่แล้ว

      No worries sir salamat din keep safe

  • @geoffreyjahooksiraba7704
    @geoffreyjahooksiraba7704 11 หลายเดือนก่อน

    Thanks, very informative.
    I also have a problem with a 200kva Cummins, where I keep getting a low coolant level shutdown alarm.
    So far I replaced the sensor but the alarm comes on after about 2 hours running on full load?

    • @benzblogsVlogs
      @benzblogsVlogs  11 หลายเดือนก่อน

      Did you install low coolant level sensor or sw only?

    • @benzblogsVlogs
      @benzblogsVlogs  11 หลายเดือนก่อน

      Make it sure so we can solve the problem

  • @aklilA
    @aklilA 2 ปีที่แล้ว

    Thanks for your helpful videos. can you please tell me the reason why air-cooled engine is overheating after the overhaul? All timing and valve adjustment are correct and also the cooling fan is well working, there is good oil circulation. Can it have other issues to see?

    • @benzblogsVlogs
      @benzblogsVlogs  2 ปีที่แล้ว

      Air cold engine is higher temp than the water cooled engine just make sire the correct passage of the and the oil and the air t avoid overheat sometime overfueling leads to this problem too

  • @obasekipaul7529
    @obasekipaul7529 ปีที่แล้ว

    This is great thanks, please what is the fault when the generator running for a short time and then shout down on generator looked out?.

    • @benzblogsVlogs
      @benzblogsVlogs  ปีที่แล้ว

      Sir double check the alarms thin their your can find what really in the problem just scroll the screen to alarms use the push botton to scroll

  • @armbangs
    @armbangs 3 ปีที่แล้ว

    Appreciate your video, can you make also video about programming a harsen controller..

  • @bismilkhan3149
    @bismilkhan3149 3 ปีที่แล้ว

    Super my friend I leaned something every day from you.. I chat with you last week in Facebook..

    • @benzblogsVlogs
      @benzblogsVlogs  3 ปีที่แล้ว

      Thabk bro bless and keep safe okay

  • @shakadelpeche261
    @shakadelpeche261 2 ปีที่แล้ว

    Very detailed video, thanks for sharing. I'm having very similar issues, generator not cranking, oil pressure alarm, engine not reaching require speed and generator lock out. This is on a FG Wilson P16.5-6S using a Deep Sea 7410 MK11 controller. Do you have any similar videos using the Deep Sea 7410 MK11 or can you advise on fixing the oil pressure issue.

    • @benzblogsVlogs
      @benzblogsVlogs  2 ปีที่แล้ว +1

      Oi pressure most common alrm you need to double check your connection and your sensor and level of your oil ither faulty already

    • @shakadelpeche261
      @shakadelpeche261 2 ปีที่แล้ว +1

      @@benzblogsVlogs Thanks for your response. I’ve made the necessary checks and everything seem OK all connection are intact, Filter are OK, oil level OK. It’s a new generator, all attempts to crank it over failed. Keep getting a LOW OIL PRESSURE ALARM.

    • @benzblogsVlogs
      @benzblogsVlogs  2 ปีที่แล้ว +1

      @@shakadelpeche261 ok if still same problem thin replace the oil sensor and check the oil viscusity is in the good condation my be need to change oil

    • @T.R.U.M.P.
      @T.R.U.M.P. 25 วันที่ผ่านมา

      Dud you ever figure your issues out? Im having the exact same issue as you with basically brand-new generator ​@@shakadelpeche261

  • @sharikhussain5817
    @sharikhussain5817 3 ปีที่แล้ว

    Very Nice information 👌

  • @SeigfredWall
    @SeigfredWall 3 ปีที่แล้ว

    Nice content... Master..

  • @AsgarKhan-uk1kp
    @AsgarKhan-uk1kp ปีที่แล้ว

    Nice information sir

  • @generemaxfernandez5878
    @generemaxfernandez5878 ปีที่แล้ว

    Ty for your sharing sir merry xmas

  • @eggycoolteknik5897
    @eggycoolteknik5897 ปีที่แล้ว

    Good job broo

  • @jaykesapalaran5434
    @jaykesapalaran5434 2 ปีที่แล้ว

    Sir sana magka roon ka po ng trade school sa pilipinas para ma I share mo lahat ng experience mo bilang maging Isang MAGALING na technician ng generator.

  • @Mhasso-gs7lr
    @Mhasso-gs7lr ปีที่แล้ว

    Hello ! Thanks for a great video.
    I have a generator that starts in a few seconds then shuts down due a low oil pressure. What is the issue in your opinion and what parameter should I adjust ? Where can I download the software from ?
    Thanks i hope you reply.

    • @benzblogsVlogs
      @benzblogsVlogs  ปีที่แล้ว +1

      My openion is check whin this engine maintinance and if no do the meantainance change oil filter fuel filter this. After that if still same remove the sensor oil and double check the wiring okay

    • @Mhasso-gs7lr
      @Mhasso-gs7lr ปีที่แล้ว

      @@benzblogsVlogs I’m getting around 2,5 bar of oil pressure and recently changed the oil filter as well . Thanks again

    • @benzblogsVlogs
      @benzblogsVlogs  ปีที่แล้ว +1

      Replace oil sensor

    • @Mhasso-gs7lr
      @Mhasso-gs7lr ปีที่แล้ว

      @@benzblogsVlogs okay ! Thank you 🙏

    • @Mhasso-gs7lr
      @Mhasso-gs7lr ปีที่แล้ว

      @@benzblogsVlogs The display shows that there is oil pressure and it should shut down at 1.3 bar and I have 2.5 bar . But it still shuts down due generator locked out (oil pressure low )

  • @samuelkahiga-sx4wd
    @samuelkahiga-sx4wd 8 วันที่ผ่านมา

    Sir how do you go about a 7320 deep sea that shows engine failed to stop while already in rest mode or not learning.,kindly explain this

    • @benzblogsVlogs
      @benzblogsVlogs  7 วันที่ผ่านมา

      Due to you oil sensor or sw

    • @samuelkahiga-sx4wd
      @samuelkahiga-sx4wd 6 วันที่ผ่านมา

      @@benzblogsVlogs thank you for the reply....have tried to replace it several times but the issue persists...is there in any way you can adjust it in terms of setting to make it work ...

  • @thunderman7505
    @thunderman7505 ปีที่แล้ว

    Mr Benzblog, I have a 6120 Mii with brand new Perkins Diesel engine and all the sudden it shows Emergency lock out. So, I have changed all the Controller but still it is a same and Also, the oil and fuel sensor has been replaced and nothing has changed. So, I'm wondering what this could be.?
    Thank you

    • @benzblogsVlogs
      @benzblogsVlogs  ปีที่แล้ว

      If you look the wiring of emegency stop there are two emegency stop make sure the connection is good ang the push button have a contact sw inside of it take a look if still good condation ang measure it from the module dc boltage if there is if not means ither lose connection or faulty push button contact ither one if it

    • @benzblogsVlogs
      @benzblogsVlogs  ปีที่แล้ว

      th-cam.com/video/3mUv0sYx7H8/w-d-xo.html

  • @generemaxfernandez5878
    @generemaxfernandez5878 ปีที่แล้ว

    Ty sir for ur sharing your talent god bless u

  • @user-zn1hg1vb4c
    @user-zn1hg1vb4c 3 ปีที่แล้ว

    Nice jie goodjob😊

  • @hasnain3963
    @hasnain3963 2 ปีที่แล้ว

    Problem solved thanks.

  • @richieuntaran8530
    @richieuntaran8530 2 ปีที่แล้ว +1

    Sir can you teach me how to wiring from speed controller governor esd5500 going dse 5110. Thanks and good day sir

    • @benzblogsVlogs
      @benzblogsVlogs  2 ปีที่แล้ว

      Sir juat til me what speed controller and for single dz or synch

    • @richieuntaran8530
      @richieuntaran8530 2 ปีที่แล้ว

      @@benzblogsVlogs not for syncronizing sir, just only like cummins or volvo generator, they have actuator, mpu and battery in speed controller

  • @jaykesapalaran5434
    @jaykesapalaran5434 2 ปีที่แล้ว

    Sir may nagawa ka na ba na libro para sa generator??? Mga basic troubleshooting at mga does and don't na pag PM ng generator???

    • @benzblogsVlogs
      @benzblogsVlogs  2 ปีที่แล้ว

      I think wala pa sir sa mga company lang rule nila sa pg ppm ng mga generators

    • @jaykesapalaran5434
      @jaykesapalaran5434 2 ปีที่แล้ว

      By the way sir may trade school ba sa pilipinas para sa generator technician??? If Meron mag kano Po pag mag enroll??

  • @lisaloprestodehart1606
    @lisaloprestodehart1606 2 ปีที่แล้ว

    Any clue on 2013 kohler 20resa rotor lockout. Cranked ran a min then tried again it click then throws code. It's not battery or wires. Cant get anyone up on the mountain.

    • @benzblogsVlogs
      @benzblogsVlogs  2 ปีที่แล้ว

      In this case repalce oil sensore and sw may this the problem thanks

    • @lisaloprestodehart1606
      @lisaloprestodehart1606 2 ปีที่แล้ว

      @@benzblogsVlogs will those make the rotor not turn or do they not turn freely when off? I cant find anything on rotor lockout fault only says check battery lol

    • @benzblogsVlogs
      @benzblogsVlogs  2 ปีที่แล้ว

      If battery problem use multi meter to check thank

    • @lisaloprestodehart1606
      @lisaloprestodehart1606 2 ปีที่แล้ว

      @@benzblogsVlogs no I put new battery just incase. The fault is rotor lockout it will click only not start

    • @benzblogsVlogs
      @benzblogsVlogs  2 ปีที่แล้ว

      Show me the alrm posible what kva your generator

  • @inocenelson1943
    @inocenelson1943 2 ปีที่แล้ว

    Sir,I watched how you flush and reprogrammed a deepsea controller that showed blank on the deepsea controller.please advice me how I can purchase this deepsea controller flush kit

    • @benzblogsVlogs
      @benzblogsVlogs  2 ปีที่แล้ว

      Bro just follow what i said go to deepsa config and find firmware update no need flash same update the lataste version and follow what instruction give to you by the configurate and done ok

  • @umehmmaduabuchi7879
    @umehmmaduabuchi7879 11 หลายเดือนก่อน

    Sir I think you can reset that in the module directly instead of using your laptop. Please explain better or show how to reset direct from module

    • @benzblogsVlogs
      @benzblogsVlogs  11 หลายเดือนก่อน

      What reset u want alrms? Pls clarify your questions

  • @AuduEmmanuel1
    @AuduEmmanuel1 ปีที่แล้ว

    My P20 julaili Bros Genset is running on Auto but always failing with generator locked out alarm, I don't have the software for the program as explained on this video, what do I do please.

    • @benzblogsVlogs
      @benzblogsVlogs  ปีที่แล้ว

      Look the alarm list so we can identify easily what is the real problem why

  • @jaycabalu911
    @jaycabalu911 2 ปีที่แล้ว

    Sir what is the possible fault alarm of this? DSE6020 indicate crank fault. Starting motor no power.

    • @benzblogsVlogs
      @benzblogsVlogs  2 ปีที่แล้ว

      Ganito gawin mo bypass mo mona para malamn mong ok pa ang starter moter mo baka mga relay lang ang defective or walang supply

  • @reldhenielniadas5669
    @reldhenielniadas5669 3 ปีที่แล้ว

    Good eve. Sir'
    Can i ask regarding DSE 8610 memory corruption alarm display how i can recover the normal display of controller?

  • @jemiesanpedro4481
    @jemiesanpedro4481 3 ปีที่แล้ว

    God bless po.. Sau boss

  • @maryamabbaslawal1979
    @maryamabbaslawal1979 ปีที่แล้ว

    Hello sir. i have the DSE6120 MODULE AND THE ALARM SOUND KEEPS ON AND THE GEN KEEPS SAYING "FAILED TO STOP" AND IT WONT SAID ALSO IT DOES NOT CRANKING ANYMORE. PLEASE CAN YOU HELP ME. THANK YOU

  • @elporky6420
    @elporky6420 ปีที่แล้ว

    I have a natural gas generator with an 8610 MK2. I press the button to start and it doesn't crank at all, but the countdown timer counts down as if it was cranking. Fuel on, then cranking 10,9, etc. Any idea what it might be? Thank you in advance

    • @benzblogsVlogs
      @benzblogsVlogs  ปีที่แล้ว +1

      Check battery supply fuse from suply from relay and check starter itself if working of faulty

    • @elporky6420
      @elporky6420 ปีที่แล้ว

      I checked fuses and relays and they look good. Starter is also good. When I disconnect and reconnect battery. I only get one crank first attempt. 2nd attempt, only countown timer no crank.

    • @benzblogsVlogs
      @benzblogsVlogs  ปีที่แล้ว

      @@elporky6420 check how much drop down voltage duting crank coz this i think battery is the issue

    • @elporky6420
      @elporky6420 ปีที่แล้ว

      They are brand new batteries. Thank you for your time. I appreciate your replying.

    • @benzblogsVlogs
      @benzblogsVlogs  ปีที่แล้ว

      @@elporky6420 only one thing you can check is the voltage drop and current drwn during crank time

  • @jagjeetsingh-ih3zv
    @jagjeetsingh-ih3zv ปีที่แล้ว +1

    🌷

  • @mohammedal-qadi104
    @mohammedal-qadi104 6 หลายเดือนก่อน

    Sir I do have emergency stop alarm though the emergency stop push button is open what is the reason??

    • @benzblogsVlogs
      @benzblogsVlogs  6 หลายเดือนก่อน

      Check ither contact is open or no positive supply going back tobyour module check using mukti mter

  • @leonardygrobay1153
    @leonardygrobay1153 2 ปีที่แล้ว

    Sir i had a trouble with our company smart gen 25kva generator.. the touble was pressure low alarm.. i watch on youtube..try to solve it..I try to replaced the oil pressure sensor.. but its still there the problem.. its same apear on panel board..LOW PRESSURE ALARM.. can u help me.. what should I do..tnx in advance

    • @benzblogsVlogs
      @benzblogsVlogs  2 ปีที่แล้ว +1

      If not remove in reset thin check the wiring and thin if same replace it check also the oil viscosity and level

  • @vicgonzales1326
    @vicgonzales1326 หลายเดือนก่อน

    boss lodi any idea bk mtulungan mko dko kc mkuha ung sofware pra sa 7310mk2 thnx in advance

    • @benzblogsVlogs
      @benzblogsVlogs  หลายเดือนก่อน

      Sir free lng yan sir ponta klng sa website nila sign up ka its full free

  • @shajeemonjohany5645
    @shajeemonjohany5645 3 ปีที่แล้ว

    Nice bro

  • @user-uf9tt3yg7h
    @user-uf9tt3yg7h 2 หลายเดือนก่อน

    Why maintenence alam 1 and lock out signs on in my Genset.

    • @benzblogsVlogs
      @benzblogsVlogs  2 หลายเดือนก่อน

      Meaning need to do maintainance and thin reaet it after the work so nit give you an alarm and generator will start

  • @SeigfredWall
    @SeigfredWall 3 ปีที่แล้ว

    Halimbawa master... Kung wla kang laptop pwde parin ba i reset yan sa module..or control panel?

    • @benzblogsVlogs
      @benzblogsVlogs  3 ปีที่แล้ว

      Yes sir pwedi g pwedi my designated na reset botton sir sa module pwedi morin switch off para totally reset unless kongmay alarm kailangan mo talagang resolve ang problima bago mawala ang alarm

  • @ssemassem8838
    @ssemassem8838 10 หลายเดือนก่อน

    What dose ECU amber alram mean on deep sea

    • @benzblogsVlogs
      @benzblogsVlogs  10 หลายเดือนก่อน

      Alarm amber meaning not mijor alrm mostly causing wayer in fuel or air mixture in fuel filter

  • @williamvillaruel2066
    @williamvillaruel2066 2 ปีที่แล้ว

    Hello sir
    Ask klng paano e troubleshot generator automatic start but goes off once din e switch ko ulit generator switch button para mag auto cya ulit

    • @benzblogsVlogs
      @benzblogsVlogs  2 ปีที่แล้ว

      Ano yan maam naka AMF or nka ATS

  • @iepdcpower3343
    @iepdcpower3343 2 ปีที่แล้ว

    Sir can please teach us how to program it like Deif and DSE

    • @benzblogsVlogs
      @benzblogsVlogs  2 ปีที่แล้ว

      First thing sir you need the app and its should be just follow in my yt there is how to do it

  • @olusanyaabisoye3138
    @olusanyaabisoye3138 2 ปีที่แล้ว

    Am having issue with my generator, the DSE 7210 is displaying ECU RED. How do i fix this?

    • @benzblogsVlogs
      @benzblogsVlogs  2 ปีที่แล้ว

      Ecu red means you have problem of your engine if you have est tool kit there you can check

    • @olusanyaabisoye3138
      @olusanyaabisoye3138 2 ปีที่แล้ว

      @@benzblogsVlogs thank you sir,but I didn't have est tool kit with me

  • @mystery7310
    @mystery7310 2 ปีที่แล้ว

    Sir tanung ko lang po ano Ba possibilidad bakit Hindi maka takbu to generator n inooperate ko nagana yung starter motor nya pero Hindi siya sumasabit sa flywheel or ringer.. hindi po kayo sira ang starter solenoid nito?

    • @benzblogsVlogs
      @benzblogsVlogs  2 ปีที่แล้ว +1

      Pag ganyan sir ither sira na ang ngipon or dina natulak yung soleniod ng starter mo

    • @benzblogsVlogs
      @benzblogsVlogs  2 ปีที่แล้ว

      Try to remove and try to give supply to check if your starter condation is maayus pa

    • @mystery7310
      @mystery7310 2 ปีที่แล้ว +1

      @@benzblogsVlogs salamat sir. Baka po sira n nga yung solenoid kasi di na siya mag tulak pero nagana ang starter motor nya.request ko na Lang siguro ng michaniko para mas check.

  • @powerengineering1913
    @powerengineering1913 2 ปีที่แล้ว

    Hello sir. What would be the cause of generator locked out on deepsea 6120mkiii

    • @benzblogsVlogs
      @benzblogsVlogs  2 ปีที่แล้ว

      Sir if you mean lock out there alarm should be ither emegency stop , high temp its depend on juat take a look on the alrms list you can see there why its lock because duting alarm it is not rectify as a gevin time now module outomaticaly lock out to avoid any failure in your engine

    • @benzblogsVlogs
      @benzblogsVlogs  2 ปีที่แล้ว

      Send me the alarm so i can guide you to the next thing to do

  • @subhadeepsahu3996
    @subhadeepsahu3996 2 ปีที่แล้ว

    Sir Mera Dg generator ka display mey-"ENGING STARUS
    WARNING
    OILP LOCK OUT
    MANUAL" -yahi likha so ho raha hai or koi display me Kam nahin ho raha hai..start button kharab ho gaya hay.

    • @benzblogsVlogs
      @benzblogsVlogs  2 ปีที่แล้ว

      Do one one thing fix first the problem before you can reset in the module that kind of alarm

  • @carlosochoa4058
    @carlosochoa4058 2 ปีที่แล้ว

    Hi, we have a problem with a Perkins plant. Sometimes when it starts up with low oil pressure, other times it starts up but makes a noise when it starts like a gurgling, acpm filter pressure sensor was changed, the oil in the fuel filter was changed and the fault continues What can be

    • @benzblogsVlogs
      @benzblogsVlogs  2 ปีที่แล้ว

      Sir bith you change the sw snd sensor anong kva po sif sorry laye reply

    • @benzblogsVlogs
      @benzblogsVlogs  2 ปีที่แล้ว

      If electronic enegine you need EST to troubleshoot such problem but if conventional just sure the you replace both sw and sensor and make sure po do the propper change oil and config.

    • @carlosochoa4058
      @carlosochoa4058 2 ปีที่แล้ว

      @@benzblogsVlogs everything was changed and it was no use

  • @weetv69
    @weetv69 3 ปีที่แล้ว

    Sir, flushing and excite of generator sir to check if alternator or exciter is in good condition sir. Next in line po sir. Thanks. Medyo kinakabahan lang dahil hnd pa nakasubok at 1000 kVA yung generator.

    • @benzblogsVlogs
      @benzblogsVlogs  3 ปีที่แล้ว

      No issue sir same small to big

    • @benzblogsVlogs
      @benzblogsVlogs  3 ปีที่แล้ว

      Juat make sure that all on correct and safety ok pag nag flashing tayo always used 12vdc volt and remove ac sensing to the avr

    • @dennisducalang3112
      @dennisducalang3112 3 ปีที่แล้ว

      @@benzblogsVlogs sir San po kita pwede makontak? Salamat, sa, mga, blogs mo sir malaking tulong Lalo na, sa mga ofw na electricians..

    • @benzblogsVlogs
      @benzblogsVlogs  3 ปีที่แล้ว

      @@dennisducalang3112 sir dito po

    • @benzblogsVlogs
      @benzblogsVlogs  3 ปีที่แล้ว

      @@dennisducalang3112 facebook.com/groups/1581429425388674/

  • @brucelimbago7861
    @brucelimbago7861 3 ปีที่แล้ว

    Sir magandang gabi or araw tanong lang kung pano maka kuha ng DSE sytem para maka pag load or makapag palit ng settings sa mga DSE monitoring or engine controll pannel salamat po sa sagot...

    • @benzblogsVlogs
      @benzblogsVlogs  3 ปีที่แล้ว

      DSE APP you mean ponta kalang sa website nila sir mag resgister ka doon tapos magpadala sila confermation at pagkatapos noon pwedi kna magupload ng sofware nila www.deepsea.com

    • @brucelimbago7861
      @brucelimbago7861 3 ปีที่แล้ว +1

      @@benzblogsVlogs okey sir salamat po

  • @lahiruwajira3905
    @lahiruwajira3905 5 หลายเดือนก่อน

    Why does Crank Attempt1 fail here?

    • @benzblogsVlogs
      @benzblogsVlogs  5 หลายเดือนก่อน

      There is more reason behind it some are battery low some are fuel is not present in the emjector,

  • @babikiradam6256
    @babikiradam6256 2 ปีที่แล้ว

    What is the Crank Attempt 1

    • @benzblogsVlogs
      @benzblogsVlogs  2 ปีที่แล้ว

      Crank attemp means module is trying again to crank depend on your configuration but standrard is 3 times only so the engine will crank 3 time until generation will run.

  • @pinoytechelectrical
    @pinoytechelectrical 2 ปีที่แล้ว

    Sir ganda araw po my generator it won't run the warning is DIGITAL INPUT C what is the cause how i will fix it. Thanks

    • @benzblogsVlogs
      @benzblogsVlogs  2 ปีที่แล้ว

      Sir take a look with the digital input and check the wire and the confige why its not program propperly

  • @JasperFSaludes08
    @JasperFSaludes08 ปีที่แล้ว

    Boss my tanong po ako about sa generator nmin volvo dse7310 mkii, baka my idea po kau,
    Problem
    Ayaw po magstart,ayaw umandar ang starter as in,pro pag dinadirect nmin gumagana nman starter good condition sya, ano po kaya ppsible problem bkit parang di po nagbibigay ng power papubta sa starter, my connect po ba ang fuel solinoid sa pagstart or ano po ung posible na solinoid na koniktado before start.

    • @benzblogsVlogs
      @benzblogsVlogs  ปีที่แล้ว

      Sir nka ecm yan if my ecm check mo yong main positive supply my fuse yan sa wire check mo if busted

    • @JasperFSaludes08
      @JasperFSaludes08 ปีที่แล้ว

      Yes sir nka ecm, ung fuse po ba is yung dalawa sa my ecm nia,, if yun po ai ok nman

    • @benzblogsVlogs
      @benzblogsVlogs  ปีที่แล้ว

      @@JasperFSaludes08 complito ng supply

    • @benzblogsVlogs
      @benzblogsVlogs  ปีที่แล้ว

      Ecm kc ng bibigay commang ng start sa starter kaya kong walang fuel on di yan magstart

  • @user-tk6wn2hu2q
    @user-tk6wn2hu2q 9 หลายเดือนก่อน

    good day po sir, ask lang po why my generator faild to start even crank would not,baterry is good and starter alternator, ano po pwede ko gawin salamat sa sagot..more power sir

    • @benzblogsVlogs
      @benzblogsVlogs  9 หลายเดือนก่อน

      Posible yes or relay or starter somtimes module

    • @benzblogsVlogs
      @benzblogsVlogs  9 หลายเดือนก่อน

      Use multimeter to check if any volyage out from module to starter telay

  • @jimnahmananap2128
    @jimnahmananap2128 2 ปีที่แล้ว

    sir what if all light indicator on the buttons of controller is on.. what is the cause ??

    • @benzblogsVlogs
      @benzblogsVlogs  2 ปีที่แล้ว +1

      All the light indicator is on thin make sure your configuration is in correct

    • @jimnahmananap2128
      @jimnahmananap2128 2 ปีที่แล้ว

      @@benzblogsVlogs thank you sir

  • @kiboytv7756
    @kiboytv7756 2 ปีที่แล้ว

    what if you dont have laptap to set the parameter

    • @benzblogsVlogs
      @benzblogsVlogs  2 ปีที่แล้ว

      You can not if its a synch

    • @benzblogsVlogs
      @benzblogsVlogs  2 ปีที่แล้ว +1

      But if only standard ot stand alone you can do it manualy in the module but limited

  • @viswanathan.g4567
    @viswanathan.g4567 11 หลายเดือนก่อน

    How do solve the a s lock out

    • @benzblogsVlogs
      @benzblogsVlogs  11 หลายเดือนก่อน

      Lock out meaning the alarms that not reset or rectifiy go to the alarm list there you can see thin try to rectify what alarm of the generator you have thin reaet it after tht it gone

  • @ahmedsallam5228
    @ahmedsallam5228 2 ปีที่แล้ว

    How can I contact with you? If you have time ?

    • @benzblogsVlogs
      @benzblogsVlogs  2 ปีที่แล้ว

      Just comment here or message me in my facebook account thabk you

  • @JUNCOSTILLASVLOG47
    @JUNCOSTILLASVLOG47 3 ปีที่แล้ว

    Black out video mo Jie😁

  • @gilbertcornerstv792
    @gilbertcornerstv792 3 ปีที่แล้ว

    Sir ask ko lng kung problema sa genset namin shutdown voltage up lumalabas thanks God bless...

    • @benzblogsVlogs
      @benzblogsVlogs  3 ปีที่แล้ว

      Meaning di naabot or sobrang taas yung numinal adjust to the voltage accodingly kong ano man ang settings sa program ither 240 or 440

    • @benzblogsVlogs
      @benzblogsVlogs  3 ปีที่แล้ว

      Ang alarm nyan ither over or under voltage to para makacguro gamitan mo ng votage meter para masure

    • @gilbertcornerstv792
      @gilbertcornerstv792 3 ปีที่แล้ว

      Kei sir maraming salamat

    • @benzblogsVlogs
      @benzblogsVlogs  3 ปีที่แล้ว

      Salamat din sir bless you

  • @agent70vids3
    @agent70vids3 3 ปีที่แล้ว

    Tumatakbo ung cummins KTA38 with DSE 8610 MKII, bigla nalang nagshutdown, may alarm na Generator Locked out. Ayaw mareset, sa alarm ang nakalagay, emergency stop. Ok naman contact ng emergency stop. Ano possible reasons?

    • @benzblogsVlogs
      @benzblogsVlogs  3 ปีที่แล้ว

      Pwedi dalawang source ng emergency stop sir isa main ang isa ay connected sa digital input at naka config ng emergency stop din pero magkaiba ng suply ngayun first gawin mo double check mo lang yjng pinangalingan ng supply my fuse or breaker yan baka busted or trip lang sir

    • @benzblogsVlogs
      @benzblogsVlogs  3 ปีที่แล้ว

      Kc kong may supply dapat wala na yung alarm sir ganito din gawin mo sir pilonta sa sa module tingnan mo ang alarms list makikta mo doon lahat ng alrm baka di lang emergency stop pwedi vediohan mo para makita natin paano nag shudown

    • @benzblogsVlogs
      @benzblogsVlogs  3 ปีที่แล้ว

      Minsan pag lockout ang module ibigsabihin yung alarm ay dipa natangal kaya naglockout sya mawawa lng yan lockout if na rectify na yung alarm

    • @agent70vids3
      @agent70vids3 3 ปีที่แล้ว

      @@benzblogsVlogs emergency stop nakalagay sa event log, pero ok naman emergency stop. Yung inoff ko power tapos ON ko ulit, ang lumabas sa display "Memory Corruption refer to Manual" yung sinubukan redownload ng program ayaw na, sira na daw yung deepsea controller. Tama po ba findings? Ano kaya posibilidan nun bakit nag Memory corruption sya at hindi na po ba maayos yun?

    • @benzblogsVlogs
      @benzblogsVlogs  3 ปีที่แล้ว

      Ok sir nx blog ko gagawin ko yan pano e recover

  • @williamvillaruel2066
    @williamvillaruel2066 2 ปีที่แล้ว

    And another thing po totally off and LCD monitor ng control board pero gumagana padin

    • @benzblogsVlogs
      @benzblogsVlogs  2 ปีที่แล้ว

      No if you have other defective module take that lcd and transfer it to this module or else try to open and clean the rebon inside

  • @arunarashidsheriff6623
    @arunarashidsheriff6623 ปีที่แล้ว

    What cause trubocharger is Red

    • @benzblogsVlogs
      @benzblogsVlogs  ปีที่แล้ว

      Depend on the engine some time you have to check enjector ,injextor calebration, airpressure , intercooler

  • @mechanicdodz
    @mechanicdodz 3 ปีที่แล้ว

    Sir. Pwedi koba malaman massenger MO Kong pwedi sana. Patulong Sana ako sa unit ko dto Perkins.

    • @benzblogsVlogs
      @benzblogsVlogs  3 ปีที่แล้ว

      facebook.com/groups/1581429425388674/

    • @mechanicdodz
      @mechanicdodz 3 ปีที่แล้ว

      @@benzblogsVlogs sir Yong Perkins ko dto nag over speed sya... Tapos may Naka lagay monitor fail stop. Kaya ba reset ito sir. Salamat.

    • @benzblogsVlogs
      @benzblogsVlogs  3 ปีที่แล้ว

      Ok sir no problem ilang kva sir message mo ako sir hanapin mo lang Benjie mosquite sa facbook

  • @piecies_03_44
    @piecies_03_44 3 ปีที่แล้ว

    Tanong lng boss sa program ba my apps pba or diritso na USB cable from module to lap tap

    • @benzblogsVlogs
      @benzblogsVlogs  3 ปีที่แล้ว

      Normal na my app ka para sa module ko anong module na gamit mo tulad ng deepsea dapat my app ka para doon

    • @piecies_03_44
      @piecies_03_44 3 ปีที่แล้ว

      Ok boss anong apps fit sa deepsea module..xenxa na boss napatanong😅😅

    • @benzblogsVlogs
      @benzblogsVlogs  3 ปีที่แล้ว +1

      Deepsea configuration fit nayaun sa lahat ng deepsea

    • @piecies_03_44
      @piecies_03_44 3 ปีที่แล้ว

      Salamat boss sa mga tips keep safe Boss

  • @naveedahmad4103
    @naveedahmad4103 2 ปีที่แล้ว

    hi dear

  • @kiboytv7756
    @kiboytv7756 2 ปีที่แล้ว

    how to download the sofwer

    • @benzblogsVlogs
      @benzblogsVlogs  2 ปีที่แล้ว

      Just go the there sire regester there

    • @benzblogsVlogs
      @benzblogsVlogs  2 ปีที่แล้ว

      Go www.deepsea.com its free just registered there

  • @henrybugtong8488
    @henrybugtong8488 3 ปีที่แล้ว

    Boss ano dapat gawin pag ang alarm ay Failed to stop.

    • @benzblogsVlogs
      @benzblogsVlogs  3 ปีที่แล้ว

      Sir ganito ang pwedi mong gawin faild to stop ibigsabihon my problima oil sensor mo check mo oil level if ok and vescusity thin if all ok replace mona oil sensor mo

    • @henrybugtong8488
      @henrybugtong8488 3 ปีที่แล้ว

      Boss maraming salamat sa pag-sagot.....

  • @indrajitbiswas9647
    @indrajitbiswas9647 2 ปีที่แล้ว

    hi sir GENERATOR OF DISPLAY is just being RAIDING locked out. How to solve. I saw your video. I have done it that way but it is not happening. DISPLAY NO. 6120 MKIII
    Please help me....

    Please help me

    • @benzblogsVlogs
      @benzblogsVlogs  2 ปีที่แล้ว

      Ok if lock there is alarm for that check the module what is the alarm list this if found it rectify the problem my nit only one make that all you rectify first before you can reaet it from the module stop botton double click it to reset

    • @indrajitbiswas9647
      @indrajitbiswas9647 2 ปีที่แล้ว

      Oil engine fult

    • @indrajitbiswas9647
      @indrajitbiswas9647 2 ปีที่แล้ว

      Thank you for reply sir... I well try

    • @indrajitbiswas9647
      @indrajitbiswas9647 2 ปีที่แล้ว

      Sorry, oil sensor fult showing

    • @benzblogsVlogs
      @benzblogsVlogs  2 ปีที่แล้ว

      @@indrajitbiswas9647 thanks too

  • @user-zn1hg1vb4c
    @user-zn1hg1vb4c 3 ปีที่แล้ว

    Pa shoutout and subscribe narin si kalokongjho😊salamat

  • @kyoot_leah6973
    @kyoot_leah6973 2 ปีที่แล้ว

    Sir paano e reset ang alarm sa module

    • @benzblogsVlogs
      @benzblogsVlogs  2 ปีที่แล้ว

      If yu want to reset the alarm and if your using deepsea just pres stop and double click it to reset

  • @transientmatter6088
    @transientmatter6088 ปีที่แล้ว

    Can you give securty pin to deepsea controllers to avoid people access it in front panel?

  • @ssemassem8838
    @ssemassem8838 10 หลายเดือนก่อน

    750 kva

  • @harleyarnado6538
    @harleyarnado6538 3 ปีที่แล้ว

    good day sir, ano po ba ang posibling dahilan ng error na ito sa Generator namin Taylor Power system sir;
    *04/BOC L1 under
    *05/BOC L2 under
    *06/BOC L3 under
    *07/Underspeed
    *salamat po sa sagot in advance.

    • @benzblogsVlogs
      @benzblogsVlogs  3 ปีที่แล้ว +1

      Sir nbalance load yan sir

    • @benzblogsVlogs
      @benzblogsVlogs  3 ปีที่แล้ว +1

      Check mo sensing fuse nya sir yung pomonta ng module baka fuse lang ang my prblima minsan ngayn lang busted lang ang fuse or trip

    • @harleyarnado6538
      @harleyarnado6538 3 ปีที่แล้ว

      @@benzblogsVlogs nag testing na kami sir na hindi namin nka contact/switch sa load, ganon pa rin. thanks sa reply

    • @harleyarnado6538
      @harleyarnado6538 3 ปีที่แล้ว

      @@benzblogsVlogs cge sir, e check namin to.

    • @benzblogsVlogs
      @benzblogsVlogs  3 ปีที่แล้ว +1

      @@harleyarnado6538 kong ganon double check nyo lang fuse check nyo din ang voltage if ilan an output double check the rpmilan inabot

  • @mobolajiadeniyi7875
    @mobolajiadeniyi7875 9 หลายเดือนก่อน

    There was lock out alarm on a generator and it went down . Gen was restarted what can be the issue

    • @benzblogsVlogs
      @benzblogsVlogs  9 หลายเดือนก่อน

      You can see the problem in the alrm list

  • @SeigfredWall
    @SeigfredWall 3 ปีที่แล้ว

    Nice content... Master..