Generator and Technical Contents
Generator options and configuration 400kva
In this video give u more details about the options and function of this generator where we are the one make the configuration and functional test
มุมมอง: 106
วีดีโอ
#SCHNIEDER MICRO LOGIC LSI HOW SET AND CALCULATE
มุมมอง 31812 ชั่วโมงที่ผ่านมา
In this video I explain how to set and calculate this micro logic from schnieder breaker which is L-is for your overload and S-is for you short circuit and I-is for your instantaneous protection.
#2806engine Leroy somer alt 380 vac 60 hz synchronizing
มุมมอง 7216 ชั่วโมงที่ผ่านมา
In this video give you an example on how we did the synchronizing we encountered some trouble using the right tools to fix easier is must so watch till end to know more how we succeeded to this project.
#LSIG ABB BREAKER PROTECTION #HOW TO SET AND #CALCULATE
มุมมอง 134วันที่ผ่านมา
In this video explain how to do the settings and calculation LSIG breaker trip.
#2506PERKINSENGINE OPTION TEST AND TROUBLE SHOOTING
มุมมอง 19321 วันที่ผ่านมา
IN this video showing wiring troubleshooting,configuration,
#2806engine synchro options troubleshooting
มุมมอง 25628 วันที่ผ่านมา
In this video we are given some ideas on how to fix this type of problem and we show you how we succeed in synchronising.
#2206seriesengine #talalternator #synchronizing
มุมมอง 364หลายเดือนก่อน
In this video i show you the troubleshooting of what this generator is and how to use a multimeter to check pls watch the video till end thank you
MECCALTE ALTERNATOR DIFFERENT STANDARD CONNECTION? 400VAC 50HZ
มุมมอง 135หลายเดือนก่อน
In this video i explain what happened to the connection why it is reverse polarity and it looks like wiring is not the usual wiring we see in other alternator which is 400vac 50hz output pls watch till end.
#4006SERIES #ENGINE #MYDAILYWORK
มุมมอง 151หลายเดือนก่อน
Load testing 4006 series engine, preparations, load calculation, and programing pls watch my video thank you always.
Deepsea 8610mk2 Basic configuration explain
มุมมอง 243หลายเดือนก่อน
In the video i explain on how to do a configuration what are the function how to make it work make aure to watch ao you can underatand and comment below if u have questions thank you
DEEPSEA 8610 MK2 wiring diagram and functionality simplify
มุมมอง 385หลายเดือนก่อน
DEEPSEA 8610 MK2 wiring diagram and functionality simplify
SOLAR INVERTER AND GENERATOR SYNCHRONIZING EXPLAIN
มุมมอง 1772 หลายเดือนก่อน
SOLAR INVERTER AND GENERATOR SYNCHRONIZING EXPLAIN
HOW TO TROUBLESHOOT AND REMOVE 1206 PRIME PUMP
มุมมอง 3402 หลายเดือนก่อน
HOW TO TROUBLESHOOT AND REMOVE 1206 PRIME PUMP
#FACTORYLOADTESTING #770kva and inductive load bank
มุมมอง 833 หลายเดือนก่อน
#FACTORYLOADTESTING #770kva and inductive load bank
GOODWE Green operating indicators explain
มุมมอง 523 หลายเดือนก่อน
GOODWE Green operating indicators explain
HOW TO PREPARE AND DO MAINS GRID SYNCHRONIZING
มุมมอง 8613 หลายเดือนก่อน
HOW TO PREPARE AND DO MAINS GRID SYNCHRONIZING
#HOW TO IDENTIFY PERKINS SERIAL NUMBER
มุมมอง 923 หลายเดือนก่อน
#HOW TO IDENTIFY PERKINS SERIAL NUMBER
HOW TO FIX FAIL TO OPEN BREAKER AND PREPARE SYNCHRO 500KVA
มุมมอง 3523 หลายเดือนก่อน
HOW TO FIX FAIL TO OPEN BREAKER AND PREPARE SYNCHRO 500KVA
PERKINS 4012 SERIES ECM CONFIGURATION AVR CONFIGURATION LOAD TESTING PART-2
มุมมอง 1814 หลายเดือนก่อน
PERKINS 4012 SERIES ECM CONFIGURATION AVR CONFIGURATION LOAD TESTING PART-2
PERKINS 4012 SERIES ENGINE LOOM INSTALLATION AVR CONFIGURATION DSE CONGRATULATIONS LOAD TESTING
มุมมอง 1434 หลายเดือนก่อน
PERKINS 4012 SERIES ENGINE LOOM INSTALLATION AVR CONFIGURATION DSE CONGRATULATIONS LOAD TESTING
INSTALLATION OF L-SERIES IN 1104C PERKINS ENGINE
มุมมอง 4424 หลายเดือนก่อน
INSTALLATION OF L-SERIES IN 1104C PERKINS ENGINE
HOW TO ADJUST SPEED TO 1800 RPM AND 240VAC USING R120 AVR
มุมมอง 4994 หลายเดือนก่อน
HOW TO ADJUST SPEED TO 1800 RPM AND 240VAC USING R120 AVR
CONFIGURATION 7SETS OF DSE890 WITH 6120 DSE MODULE
มุมมอง 2034 หลายเดือนก่อน
CONFIGURATION 7SETS OF DSE890 WITH 6120 DSE MODULE
45KVA WITH AUTOMATIC TRANSFER SWITCH LETS SIMPLIFY
มุมมอง 2985 หลายเดือนก่อน
45KVA WITH AUTOMATIC TRANSFER SWITCH LETS SIMPLIFY
110% LOAD TEST USING CONTAINERIZED INDUCTION LOAD BANK
มุมมอง 3485 หลายเดือนก่อน
110% LOAD TEST USING CONTAINERIZED INDUCTION LOAD BANK
(Neutral in Load side of alternator) T-4 T-5 T-6 (Neutral in Line Side of output Breaker) T-10 T-11 T-12 (Install plates in this connection) T-7 to L-1 T-8 to L-2 T-9 to L-3 Tama ba to Sir? 400v to 220v L-L connection
Correct but the two side neutral are joint should be
How to configure 400v to 220v
If u need to comfig 440 -220 you have to change also the wiring ang the wiring to module and alternator connection
@benzblogsVlogs the generator is 100kva/80kw 3phase, how to convert the 400v output in L-L to 220v output L-L
@benzblogsVlogs how can I convert the 400v L-L output to 220v L-L output the controller is DSE6120 MK3
@@benzblogsVlogs pwede maka hingi ng diagram pano ma convert yung 400v to 220v L-L connection
@@wintertrucheon6418 no problem
Is it 6 lead out from stator?
What is your question again pls?
@benzblogsVlogs how many lead out from stator?
Ayos lods merry Christmas
Merry christmas
Nice view lods Ganda
Wow
Nice lods
Thank you bro. for the info you have shared. More power
Welcome sir 🙏
Sir send me your what’s number and I have one issue depsea 6110 display coming start and again stop
Hi recently i am facing issue that dse 8810 not indicating any LEDs on controller and not starting like hanged condition so tried firmware updation , after updation problem solved but again it comes after power off What may be the reason
The reason is your clock battery is dead
Hello. My MPU is giving a signal of 2.1 VAC but there is no output Voltage on A and B to the actuator
Meaning there is already problem it self your speed controller try to adjuat the idle to zero
How to do it link,
No need link now only update firmware
Good explanation idol iba talaga Ang master
Bless you lods
Sir good morning. Can you teach me how to synchronize generator sets using deepsea 8610 mk2 ?
Litle bit complicated but if u have knowldge about it its easy for you
Nice one lods morning...
Bless morning 🌄 lods
Do you need to adjust AVR on DSE config suite 8610 mk2, I always adjust centre and range? Can you do a video showing that? Please
Yes if nessisary you need to catch 70-75 percent of a calibration
@ I've tried but can't always get to 70-75, if I change one, it takes the other one off track, any way you could please make a video like that?
@ I use AVR ss341, 440s, and 408
@@elporky6420 sw1-2 in 75% thin andjust the avr according to you needs
Yon o ayos idol.iba talaga..❤❤❤
Salamt lods
Watching lods
Very bad Vdo
Thank you no problem
@ Actually Language issue
Is God worker I'm apirshet u
Bless you
What is the link on how to fix the problem on DSE when it say Memory Corruption refer to Manual
Simply update firmware version after that you need to config again in order to work the module
Sir dse 8610 mk2 gov output A and B wire is connected to L series Aux1 (8) and another wire is , where to connect?
Chck the diagram and it depend on the configuration from laeries but mostly that is 3-8 but need to comfig
Helo sir, pls how can i get the password setting for iNTL amf 25
0000
Thanks for sharing sir...pls how can I change interlite amf 25 to single face mannually, it shurting down. Thank you sir
I think not posible u need laptop to config
Sir ano root cause ng ramping o hunting ?
Ramping nasa speed controller Yan pweding lagyan or Hindi Ang hunting naman is pweding dahil sa dumi Ng fuel barado or colang sa calibration sa speed controller or mismong may problima Ang enjection pump
Emcp 1.1 phase sequence incorrect alram coming in. Faults how to turn off this in settings please tell thanks
Use multi meter to check check the comnection RYB if in correct posation and equal voltage
Sir i am your big fan #Powerlearningchannel
Same with you sir i am watching your videos have bless day
Watching from Botswana Africa Master, I have a Generator set with Volvo engine with Deepsea Controller 5320 running in good condition, after a while its just switch off, no display in deepsea controller even the indicating lights is off also. We check the wirings its ok, we change the battery still no display. Is the Deepsea controller is the problem or the ECU? Please enlighten me Thanks.
First check the voltage dc if there is from the module supply after that if there is thin check the led display from the module where it has red color if there is meaning only the display is the problems
@@benzblogsVlogs Thanks master appreciate...
buenas tardes tengo un caso de falla de comunicacion pero no tengo el enlace
El configuration or wiring problimo
Is configuración me dice la pantalla memoria corrupta consulte el manual@@benzblogsVlogs
how you sense the output voltage on AVR if you remove U & W cable
In order to undertand what are the posible causes of low voltage shutdown
Also, bka pwede makabili sa company nyo ng woodward proact digital speed control model II. May minomodify akong perkins engine 4008. Ang existing speed governor ay model I. Nagkakaroon ng delay ng impulse between dse and speed governor dahil sa interposing relay. Kaya balak ko palitam ng model II para direct sa dse teminal.
Sir dipo kc ng bibinta ng parts yung company check mo nalamg sir wala akong idea but im sure di sila ngbibinta
Idol, anong pin number sa ecm ang speed governor ng 2806 engine
20-24-19 lods
Great job
Idol❤❤❤❤
Hello bro,please show laptop closeup
It can auto start but can't stop running in auto mode
Till me what the module and if there is an ats or amf function
Thanks bro, very educational. I have a question. Why can't a generator fail to stop in auto mode.
Check the the module what model check if your using remote start or amf till me thin i reply to you what is the posiblity
Hi ,how are you brother ,I am facing problem with perkins 1300 series to replace 7320 AMF controller with new 7320 MKII controller.Generator is not getting started with new controller and working good with old controller.The old controller is screen is faulty that's why need to change the controller.can you guide Thanks
Yes bro what your problem
If u replace with new controller make aure you need to config again read the old module save the file and during the configuration compare the old config and follw it so you have the guide line what are the old configuration so it will work propperly
Ikaw lang ang nag gawgawa ng trouble mo 😅😅
Oh thank you so much may Godbless you
Love you from India sir you have explained more easy thank you so much sir 🎉
Thank you bless you
When I connect my pc with device using usb cable, It is not showing anything. It says Com4 inaccessible. I tried manytimes but cant connect to device with usb cable.Any solution?
Check the settings of your module and if not working with usb thin use the rs232 to config
Or update your sofetware
Watching friend, good evening, nice sharing
Thanka
Sir how are you, I want to ask you one question about generator, I connect the cable from generator to low voltage switch board for auto pourpose but after that the generator is not starting and it's saying ECU data fail and ECU override sir please could you tell me the reason why my generator is saying like that
Acu data meaning this is the communication between your ecu and from your module this problem my happen if not connected correctly or not program the module correctly
@benzblogsVlogs sir thank you for your kind response but the generator was working for 1 year before we connect the cable for Auto main failure mode but after cable connection our generator fails to start and even the filter also have air(there is air in fuel system) and I was thinking is there any possibility that the cable which we connect to the generator for AMF mode cause the problem
I have a Honda EV6010 generator Max Output 6.0KVA, Rated Voltage 120V, 50A, 60Hz, Single Phase. My controller is dead and I have been through two replacement controllers one used and one (supposed) new?. No new controllers are available. So I bought off Amazon HQM611OU 0.5-70V. Will this Smartgen work with my existing Automatic Voltage Regulator? Will it send the DC voltage that my AVR needs to keep up with AC load?
Avr only matain you voltage not to fluctuate or dropdown but its always depend to the engine if engine also not stable also voltage not stable
@@benzblogsVlogs Do I have to have a "Magnetic Pickup" for my controller to work? Can I work around this? And this Honda generator runs when the ground for the gas engine coil is disconnected--can I get this controller to issue a ground for running and stopping?
Good job lodi
Same with you lods
Ang laki nyan lodi
Atos lodi dami nyan
Nice one lodi❤❤❤
Thank u lods
Loss of Mag- PU what does it mean?
Meaning there is connection between you magnitic pickup or defective
Watching kabayan, good evening