5V - 36V Timer Modul Trigger Mosfet Relaismodul with LED

แชร์
ฝัง
  • เผยแพร่เมื่อ 18 ธ.ค. 2020
  • 5V - 36V Timer Modul Trigger Mosfet Relaismodul with LED
    Available here(*): amzn.to/3nMajHu
    Useful links for Nissan X-Trail / Rogue abd other things:
    Nissan X-Trail TH-cam Channel ABO: bit.ly/2VeNz9c
    Soldering stations(*): amzn.to/3gE29hH
    Solder(*): amzn.to/3no9wg5
    Flux(*): amzn.to/37ahfZb
    Circuit board kits(*): amzn.to/2W6ejqd
    Foxwell equipment(*): amzn.to/3gC7ZAp
    Description:
    0.1 seconds (min) to 999 minutes (max) continuously adjustable.
    This product is easy to use, many functions, but all buyers need to carefully read the instructions, very useful product.
    Module characteristics and uses:
    To achieve fast turn-on and off the circuit, an unlimited number of switching;
    Conducting and cutting process does not produce noise, no spark, no electromagnetic interference;
    Compared with electromagnetic relay products, longer life;
    The dual-MOS parallel drive, lower resistance, more current, strong power; at room temperature, operating current of up to 15A, power up to 400W, to meet the most use of the equipment;
    A method for controlling the motor, lights, LED, DC motors, micro-pumps, solenoid valves, etc., very convenient.
    Highlights:
    Wide voltage input (5 ~ 36V), most devices can be used, very convenient;
    The interface is clear and simple, powerful, easy to understand, meet almost all your needs;
    The emergency stop function (“STOP” key);With reverse polarity protection, reverse polarity will not burn the product.
    Increase the sleep mode, if this mode is enabled, without any operation within 5 minutes, then automatically turn off the monitor, any key wake-up;
    You can set a different OP, CL, LOP parameters, which are independent of each other, and are automatically saved;
    After the module is powered down, all parameter settings are not lost.
    Operating mode:
    P1: trigger signal, the relay is on "OP" time, and then disconnect; in the "OP" time, as follows:
    P1.1: signal is triggered again, invalid
    P1.2: signal is triggered again, the clock is reset
    P1.3: Signal trigger again, relay off, stop the clock;
    P-2: trigger signal, the relay off "CL" of time, the relay on "OP" time, and then disconnect relay;
    P3.1: trigger signal, the relay is turned on after the "OP" time, the relay off "CL" time, then the operation cycle, if the trigger signal period, the relay off, stop the clock; the number of cycles ( "LOP ") can be set.
    P3.2: without triggering signal, the relay is on "OP" time, the relay off "CL" time, and has been cycling; frequency ( "LOP") cycle can be set;
    P-4: signal holding function. If there is a trigger signal timing is cleared, the relay remains on; when the signal disappears, after the timing "OP" time, the relay is; if another signal during timing, timing is cleared;
    Product parameters:
    1: Operating voltage: 5--36V.
    2: Trigger Source: Active-high (3.0V-24V), have optocoupler isolation, can improve the system's anti-jamming capability (customers can also shorting common ground).
    3: Output capacity: DC 5V - 36V, at room temperature, continuous current 15A, power 400W! Enhance heat dissipation conditions, the maximum current up to 30A.
    4: Quiescent Current: 20mA; Operating Current: 50mA
    5: Life: any switching times; Working temperature: -40-85 ℃; Size: 6.0*3.4*1.2cm.
    6: With optocoupler isolation, enhanced anti-jamming capability, industrial grade board.
    Pay attention:
    The module is an active output, the output voltage equal to the input voltage.
    2.'DC + 'and' load + 'This is an internal short circuit of the poles, but' DC- 'and' load - 'poles during use can not be shorted, otherwise the load can not be controlled on and off, which is equivalent load is been carrying electricity.
    Timer Module(*): amzn.to/3nMajHu
    Alle Angaben ohne Gewähr und gezeigtes dient nur zur Veranschaulichung und zu Test Zwecken!
    Affiliatelinks/Werbelinks:
    Die mit Sternchen (*) gekennzeichneten Links sind sogenannte Affiliate-Links. Wenn Du auf so einen Affiliate-Link klickst und über diesen Link einkaufst, bekomme ich von dem betreffenden Anbieter eine Provision. Für dich verändert sich der Preis nicht!
  • วิทยาศาสตร์และเทคโนโลยี

ความคิดเห็น • 12

  • @ammertech6216
    @ammertech6216 ปีที่แล้ว

    Vielen Dank. Möchte dies gerne für meine Trinkwasser Tauchpumpe im Wohnwagen einsetzen. Hatte es bereits bestellt. Vielen Dank für das Video.

  • @jasonbrenner9707
    @jasonbrenner9707 3 ปีที่แล้ว +1

    Vielen Dank für die Erklärung 👌👍

  • @floh_mit_h
    @floh_mit_h ปีที่แล้ว

    Danke für die Erklärung. Kann man auch das Trigger Signal mit Spannung belegen und bei Trigger Spannungslos, eine bestimmte Einschalt/Ausschaltzeit programmieren? Danke für Eure Hilfe

  • @jeees
    @jeees 2 ปีที่แล้ว

    Vielen Danke für deine Erklärung, aber könntest du mir trotzdem sagen was ist ein LOP, OP,CL ? ich möchte das in mein Fahrzeugverwenden damit das KFZ Radio...erst nach 3Min sich selbst ausschaltet, ist dies möglich ? (Das solange Strom in Triger ist, das das Gerät sich nicht ausschaltet und erst bei kein Signal der Trigger erst nach 3min sich ausschaltet ?)

  • @martinaolszowy1493
    @martinaolszowy1493 ปีที่แล้ว

    Danke für dieses Video.
    Kurze Frage: Wenn ich auf P3.2 programmiere (also kein Triggersignal möchte), schließe ich einfach nichts an die beiden Trigger-Pole an. Solange das Modul dann mit Strom versorgt wird, läuft der LOP den ich eingestellt habe...habe ich das richtig verstanden?!

    • @elektroniknissanx-trailrog2641
      @elektroniknissanx-trailrog2641  ปีที่แล้ว

      Du kannst den trigger auch nur mit batt Spannung machen - Relais ist dann in hold Position und schließt oder öffnet wenn die batt Spannung wegfällt

    • @elektroniknissanx-trailrog2641
      @elektroniknissanx-trailrog2641  ปีที่แล้ว

      Es gibt auch eine neuere Version des Moduls das über eine App programmiert werden kann. Soll es ab August in China geben … Ali , wish etc …

  • @marcelmohrchen2001
    @marcelmohrchen2001 2 ปีที่แล้ว

    Moin ist es möglich das so zu programmieren das erst der Motor läuft und dann für eine gewisse zeit nicht mehr ansteuerbar ist? quasi P2.1 nur das op und cl vertauscht sind?

  • @MonkR32
    @MonkR32 2 ปีที่แล้ว

    Hallo. Wenn das Modul zb. Ein halbes Jahr stromlos ist...ist das Programm dann immer noch gespeichert oder muss man wieder alles neu einspeichern? Liebe Grüße. Top Video!!!