    @iiikeman111 4 ปีที่แล้ว +1

    Thanks for the straight forward explanation. Came home late to find the pilot out. Took it apart, cleaned out the holes and it’s working fine

  • @dominislaw6860
    @dominislaw6860 2 หลายเดือนก่อน

    Love that kind of video short and full of usefull things

  • @alex8214997
    @alex8214997 4 ปีที่แล้ว

    Thanks a lot. I learned in depth detail of how pilot works. It really helped me to solve the yellow flame problem because I didn’t know the cap was needed to create pressure. Without the cap, yellow flame caused a lot of soots and carbon monoxide

  • @arthurvin2937
    @arthurvin2937 5 ปีที่แล้ว +1

    Mine was burning orange in my pool heater and the thermocouple was collecting unburned carbon gunk and it stopped sensing flame. I reached to clean it, and it fixed the problem, but I noticed flames under the bracket, clearly it wasn't alright because it melted sensor wire isolation off. Soon after, pilot tube broke off completely and the whole thing was burning in hell. Turns out the tube completely rusted off. I made a new aluminum tube and fittings, and now it burns in steady blue flame. I watched your video prior and couldn't understand what kind of blue flame you were talking about. Now I see.

  • @funkybioped
    @funkybioped 8 ปีที่แล้ว +1

    You vids have been super helpful for me while studying for gas coursework. Thanks

  • @kimdoug9183
    @kimdoug9183 6 ปีที่แล้ว +3

    Thank you for gas study and would be more understand about how to work as the pilot and the thermo sensor,

  • @oreo7939
    @oreo7939 3 ปีที่แล้ว

    Here for the voice over edits. Best part of all the video... 1:52 "primary air". 💪🏽🤪👌🏽

  • @Guyhakverdi
    @Guyhakverdi 8 ปีที่แล้ว +1

    I have never paid attention to that before. Good thing I know what it is now.

  • @ramcharge68
    @ramcharge68 8 ปีที่แล้ว

    Thanks for all your great videos.

  • @quangnguyen-hq1bc
    @quangnguyen-hq1bc 8 ปีที่แล้ว

    Thank you for sharing your knowledge to everyone in the world . Please keep up the program .God bless you and your family.

  • @LavlllAce
    @LavlllAce 8 ปีที่แล้ว +2

    Thank you for the video great explanation

  • @alexsfit
    @alexsfit 8 ปีที่แล้ว +1

    Thanks for share your knowledge and time master.

  • @dan020350
    @dan020350 3 ปีที่แล้ว

    will a small blue flame automatically shuts down my furnace, even i have a working thermocouple?

    • @grayfurnaceman
      @grayfurnaceman  3 ปีที่แล้ว

      If the pilot flame goes out, the pilot safety will shut down the gas supply.
      GFM

  • @need2retire543
    @need2retire543 ปีที่แล้ว

    My pilot used on a burner for a pizza oven is acting inconsistent. When I first start the oven it works fine, but as the oven come up to temp (800f) the pilot starts to die off and hence shuts off my pizza oven. Any idea why the pilot is getting cutoff when the temp is hight?

    • @grayfurnaceman
      @grayfurnaceman  ปีที่แล้ว

      You probably have a failing gas valve.
      GFM

  • @richardterry1230
    @richardterry1230 5 ปีที่แล้ว

    Question......I have a propane central heat. unit...I once tried to lite it an s it acted like there was excessive gas in the chamber....could the orfic be missing to cause that?

  • @hvacrjunky6119
    @hvacrjunky6119 8 ปีที่แล้ว

    Great video, thanks.😎

  • @lucdumouchel3864
    @lucdumouchel3864 8 ปีที่แล้ว

    Thanks for this. I've been following you since quite sometimes. I even made up a binder of a good part of what you teached us. I have a question. It's a fireplace and after 2 days you can see a huge accumulation of smoke on the window. The pressure is 10 wc.( propane) for some reason,there is no adjustment.It's installed in the basement. I cleaned it. Replace the wood onside ( not wood, but, anyways) If ever you have an idea, please let me know.

    • @grayfurnaceman
      @grayfurnaceman  8 ปีที่แล้ว

      +Luc Dumouchefl Have you adjusted primary air? Adjustment may also be dirty. Hope this helps.
      GFM

  • @geojor
    @geojor 8 ปีที่แล้ว +1

    practical video, thank you ...

  • @我我儿子爱喝喜多多
    @我我儿子爱喝喜多多 3 ปีที่แล้ว

    How to buy this accessory? What's the name of this accessory?

    • @grayfurnaceman
      @grayfurnaceman  3 ปีที่แล้ว

      It is called a pilot assembly. It is available from a local HVAC dealer.
      GFM

  • @JacobKnightRiderShop
    @JacobKnightRiderShop 5 ปีที่แล้ว

    If the pilot tip gets dirty will the furnace still run?

  • @LoneWolf-mh4ob
    @LoneWolf-mh4ob 4 ปีที่แล้ว

    I have a pretty far out there question. I have a 100lb propane tank. Could I run just a pilot light with this with the right parts? Looking to generate C02 without too much heat. Thanks!

    • @grayfurnaceman
      @grayfurnaceman  4 ปีที่แล้ว

      You could, if you simply ran a gas valve and pilot assembly set for propane in the pilot only position with the main gas outlet plugged.
      GFM

  • @ronaldcach2779
    @ronaldcach2779 8 ปีที่แล้ว

    Can you clean out the orifice hole with maybe a needle or small wire, or, small drill? Or do you have to replace the orifice, or whole assembly? THANKS FRIEND.

    • @grayfurnaceman
      @grayfurnaceman  8 ปีที่แล้ว

      You can try if you are careful not to enlarge the hole.
      GFM

    • @MrsScatCat
      @MrsScatCat 6 ปีที่แล้ว

      We got a nifty tool: Leavey Pilot Cleaning Pump Kit. Great Pilot Cleaning Tool.
      Pipe cleaners, pins, small wire, etc... enlarge the Orifice hole - then, it's replacement time. :(
      We have even used air in a can for $2.55 - that works.

  • @al52269
    @al52269 6 ปีที่แล้ว

    Q: Are all honeywell pilot burner with orifice the same?
    I'm going to replace mines. I have the OEM parts number, but unfortunately I can find it on line to buy it. Local plumming/heating supply store can find on number

    • @grayfurnaceman
      @grayfurnaceman  6 ปีที่แล้ว

      They are not the same. Depending on whether the spark ignition was original equipment or and upgrade, it could have virtually any pilot assembley.
      GFM

  • @chrissysko3259
    @chrissysko3259 8 ปีที่แล้ว

    Thank you :)

  • @donjackson4951
    @donjackson4951 7 ปีที่แล้ว

    After thoroughly cleaning off the Thermopyle, the Thermocouple, and the metal gas flame supply orifice, and vacuuming the area, my pilot light is still weak. It doesn't seem to energize the Thermocouple and Thermopyle. As a result, the main burner doesn't ignite. How can I get a robust pilot flame?

    • @grayfurnaceman
      @grayfurnaceman  7 ปีที่แล้ว +1

      If the pilot is entirely blue and covering both the thermocouple and the thermopile, it is probably ok. If not, there is a pilot adjust screw on the gas valve.
      GFM

    • @rickhayes4090
      @rickhayes4090 5 ปีที่แล้ว

      @@grayfurnaceman I have same problem , but on water heater with honeywell smart gas valve. I can not find a pilot adjustment screw....Help !!!

    • @grayfurnaceman
      @grayfurnaceman  5 ปีที่แล้ว

      @@rickhayes4090 Why do you want to adjust the pilot?
      GFM

  • @quangnguyen-hq1bc
    @quangnguyen-hq1bc 8 ปีที่แล้ว

    Thanks .

  • @christiandrury3605
    @christiandrury3605 3 ปีที่แล้ว

    SECONDARY AIR!!!

  • @zack6892
    @zack6892 4 ปีที่แล้ว

    My sisters furnace stopped working I came over and cleaned everything. After removing and cleaning this pilot/flame sensor the furnace fired right up. 3 days later she began having the same problem would it be safe to assume this part needs replaced? It was pretty dirty I cleaned it all with steel wool but there was corrosion.

    • @grayfurnaceman
      @grayfurnaceman  4 ปีที่แล้ว +1

      The flame should be blue and covering the thermocouple by 3/8". Also, there thermocouple may be weak. If the flame is ok, the thermocouple would be the first culprit I would look at.
      GFM

    • @zack6892
      @zack6892 4 ปีที่แล้ว

      @@grayfurnaceman so after getting a look at it seems like it's having a spark issue not a pilot one. It no longer Sparks like it did the first time I cleaned the thermocouple and got it working. It will spark once during starting sequence then all I hear is gas from the pilot after about 30 seconds it Sparks once ignite the pilot which is a blue flame then stops and restarts the firing sequence. I replaced the thermocouple just because I already had the part with no success could it be the intermittent spark module? Edit: after reseating the connections to the spark module I got one good ignition sequence where it sparked good then nothing. I went ahead and ordered the control module. This is for a Kenmore power miser 70 by the way pretty old unit but it worked great the very first time I cleaned the thermocouple I'm just at a loss here.

    • @zack6892
      @zack6892 4 ปีที่แล้ว

      @@grayfurnaceman appreciate your advice by the way it really helps to have an experienced professional to go to for guidance.

    • @grayfurnaceman
      @grayfurnaceman  4 ปีที่แล้ว +1

      @@zack6892 It could certainly be module.
      GFM

    • @zack6892
      @zack6892 4 ปีที่แล้ว

      @@grayfurnaceman thanks for the input I'm hopeful that solves the problem. Spark is definitely erratic at best not as it was last time it worked.

  • @armandom.5299
    @armandom.5299 8 ปีที่แล้ว

    got me at 1:22!!

  • @fishycomics
    @fishycomics 3 ปีที่แล้ว

    photos.google.com/photo/AF1QipPEv1Wj7RfNdbjmkBrxp_wjE1weWn8Fiwxvbx4L lets see if I get a quick response this looks like the same part you are referring to, I have my pilot burner let for many years, when should we change out, could be part of my issue

  • @charlesmcqueen3274
    @charlesmcqueen3274 2 ปีที่แล้ว

    None