ADD Natural Gas to Dual Fuel Generator…

แชร์
ฝัง
  • เผยแพร่เมื่อ 9 ก.พ. 2023
  • If you have a existing dual fuel generator adding a kit to make it run on Natural gas is easy. But some dual fuel inverter units will use a internal on demand regulator making it harder for the switch and will pretty much void the warranty. If that’s not a concern then you would by pass it but that would disable the propane side. Tough choices but see if this video helps you out. #Dual fuel #inverter #genmax #DIY
    TopTes Gas Detector PEN!!: www.amazon.com/dp/B0B62LBZPC?
    Buy me a Coffee 👍🏼🙌🏼👊🏼😀
    www.buymeacoffee.com/johnny5120J
    TopTes Gas Detector PEN!!: www.amazon.com/dp/B0B62LBZPC?
    Trailer and vehicle accessories
    www.etrailer.com/?etam=a0017
    Lithium SOK Batteries Solar and more!! currentconnected.com/?ref=JW
    Level your trailer FAST & EASY!!!!
    Level mate pro: amzn.to/3S2xf5c
    AWESOME BUDGET BATTERY Chins w/ low temp and blue tooth! amzn.to/3IOjVfv
    MC4 All in one Kit : amzn.to/37jwLVb
    BEST GAS CAN!! Surecan Gas can : amzn.to/3Kf5rqn
    Protect Everything!! 303 Aero space Protectant: amzn.to/329dkM7
    BEST FIRE PIT!! Outland Propane fire pit!! : amzn.to/3rKIkwZ
    Generator tent amzn.to/3ddd3ds
    Lucas fuel treatment: amzn.to/3IfxQv8
    West coast Camping group join
    / 1771083136386739
    Videos are for entertainment purposes only. Do your own research when it comes to using these products shown in any Johnny's Weekends videos.
    Thanks for watching. Above links are part of a affiliate program. As an Amazon Associate I earn from qualifying purchases, if you purchase something I earn a small commission, if you do thank you so much as it helps creators like me to continue to bring content for viewers.👍👊😊

ความคิดเห็น • 105

  • @johnnysweekends
    @johnnysweekends  ปีที่แล้ว +1

    What do you think ? Does this help answer some questions?? Let me know.
    TopTes Gas Detector PEN!!: www.amazon.com/dp/B0B62LBZPC?
    Buy me a Coffee 👍🏼🙌🏼👊🏼😀
    www.buymeacoffee.com/johnny5120J

    • @dgunearthed7859
      @dgunearthed7859 ปีที่แล้ว +1

      Kind sir, thank you. I was just wondering if you could just plug a NG hose onto a duel fuel generator. Would you HAPPEN to have a list (partial or complete) of duel fuel generators that don't have the regulator INSIDE the hose connection like you showed? ie the eaay connection you showed using the natural gas???

    • @johnnysweekends
      @johnnysweekends  ปีที่แล้ว +1

      I don’t have a list because even old models change. You would have to see what brand and size you would like and then look at the hose. That is the easy way to tell. Most smaller units will have it outside on the hose since not a lot of room in the smaller generators.

    • @dgunearthed7859
      @dgunearthed7859 ปีที่แล้ว +1

      @@johnnysweekends appreciate it, thank u

    • @NoZenith
      @NoZenith 9 หลายเดือนก่อน +1

      Much appreciated, yes this helps.

  • @davidr6856
    @davidr6856 3 หลายเดือนก่อน +1

    Very helpful. Thanks.

  • @Max-fk2es
    @Max-fk2es ปีที่แล้ว +1

    Thanks for this video. It is very informative.

  • @wow1022
    @wow1022 10 หลายเดือนก่อน +3

    i think you could do a T fitting on the existing propane hose that goes to the carburetor, drill a hole on the side of the generator, run a hose from the T through the hole that goes to a valve, on the other side of the valve you run a piece of hose to a natural gas regulator
    if you want to use propane, connect propane and turn off the valve
    if you want to use natural gas turn on the valve

  • @therealmitch-a-palooza7262
    @therealmitch-a-palooza7262 26 วันที่ผ่านมา +1

    Johnny, I think you might want to revisit this topic. I just called Century to figure out how to get a Champion dual-fuel generator running off NG, and they said an an air box snorkel is necessary. This is despite Champion generators using external demand regulators on the hose running from tank to the front panel gas inlet. They explained that the propane feed inlets are "too restrictive" to allow for these generators to run at full load with NG, even if you use a different hose with a demand regulator tuned for NG pressures.

    • @johnnysweekends
      @johnnysweekends  26 วันที่ผ่านมา

      True, plus hose length will matter as well.

  • @todd.parker
    @todd.parker ปีที่แล้ว +2

    Cool video Johnny, I didn't know you could do this! Do you think that would work with the Ecoflow dual fuel generator?

    • @johnnysweekends
      @johnnysweekends  ปีที่แล้ว +2

      Hey Todd, Thanks. Unfortunately for the Dual fuel Smart gen they use a proprietary connector that is not easily found. And the internal load regulator would have to be bypassed. Which again voids warranty when ever you like to dig inside stuff 😂👍🏼

  • @andystegner
    @andystegner ปีที่แล้ว +1

    Thanks, I am considering it as it's nice to not have to store a bunch of propane or worry about running out.
    Can you post the link to that gas detector pen please?

    • @johnnysweekends
      @johnnysweekends  ปีที่แล้ว

      I think the link is added in the description but ill double check and add

    • @johnnysweekends
      @johnnysweekends  ปีที่แล้ว +2

      Here ya go…amzn.to/3Ylbz72

  • @caseymaples19xx
    @caseymaples19xx ปีที่แล้ว +1

    Johnny, just wanted to let you know you can easily hook up a gen with internal Built in load regulator. You only have to buy a propane to natural gas conversion hose. It’s actually easier and cheaper than the one with external load regulators.

    • @johnnysweekends
      @johnnysweekends  ปีที่แล้ว

      I do t know if the internal regulator will operate correctly on the lower pressure from NG. A hose is one thing but correct pressure delivery is another.
      Did you try it with a couple models or anything ? Would be nice to just grab a hose.

    • @caseymaples19xx
      @caseymaples19xx ปีที่แล้ว +1

      @@johnnysweekends i have done it with both my pulsar gd400bn and wen dual fuel 4500 watt version. I actually needed to add a regulator as the NG supply pressure was too high.

    • @caseymaples19xx
      @caseymaples19xx ปีที่แล้ว +7

      Lemfema 10 Feet Natural Gas Hose Conversion Kit for Grill, Low Pressure Natural Gas Grill Hose with 5" Outlet Pressure Regulator Valve and 1/2" Male NPT x 3/8" Female Flare. This is what i used

    • @declineofthewest.
      @declineofthewest. ปีที่แล้ว

      @@caseymaples19xxI’m going to try this

    • @NoZenith
      @NoZenith 9 หลายเดือนก่อน

      This is cool

  • @jasonatwood66
    @jasonatwood66 ปีที่แล้ว +2

    I just found your videos yesterday - appreciate the information. Have you ever looked at the Firman WH03242? The LPG hose included with the generator looks like it has both regulators on the hose. Thanks.
    P.S. newly subscribed - thanks again for the helpful information.

    • @johnnysweekends
      @johnnysweekends  ปีที่แล้ว

      I’m not a big fan of firman but the big selling point is that it’s sold at Costco and they pretty much take dead chickens back so it’s a great selling point.
      If the both regulators is on the outside than adding a kit like this for a tri fuel setup should be easy.
      Thanks for stopping by and joining the group 😀👍🏼👊🏼

    • @fb510m
      @fb510m ปีที่แล้ว +2

      Hi. Would you know if genmax 7250 can be fitted to run on natural gas? Thanks. I dont have one to check nor know anyone that owns one

    • @johnnysweekends
      @johnnysweekends  ปีที่แล้ว

      Unless you by pass the internal load regulator then it can not be ran on NG.
      Genmax has a new Tri fuel 9000 coming out soon..👍🏼

    • @gatardif
      @gatardif ปีที่แล้ว

      Hello Jason, I am looking at the Firman WH03242 as well to use with my BBQ natural gas outlet. Did you end up trying with a kit like this?

  • @tome5345
    @tome5345 3 หลายเดือนก่อน +1

    Hi, very informative, thank you. I've had a NG feed with external regulator/conversion kit for a loud (76db) Briggs 5500 for years (works great), but have a new Pulsar 7250 coming today (62db), dual fuel. Do you know if this will work with just an external regulator/conversion kit or does it have the internal regulator that would need to be bypassed? tyia.

    • @johnnysweekends
      @johnnysweekends  3 หลายเดือนก่อน +1

      Has internal regulator. Needs to be bypassed

  • @larrylp2192
    @larrylp2192 ปีที่แล้ว +4

    What is the maximum power that you can get with this generator on NG? I have the same generator and same basic setup here, but mine shuts down above about 1200W. In my testing, I was hooked up to my NG line that normally connects to my gas grille, and it's about 50-60 ft. from the meter. I can add a takeoff point about 20 ft. closer to the generator, or worst case run a new line. I just want to make sure that the generator will put out decent power on NG... I'm hoping for something like 2400-2500W.

    • @robertholmes1556
      @robertholmes1556 5 หลายเดือนก่อน

      Did you ever figure out the peak & running watts for your generator on natural gas?
      Thanks

  • @robertprestigiacomo4657
    @robertprestigiacomo4657 ปีที่แล้ว +1

    That’s why you need a battery on dual fuel generator, the solenoid needs power to switch from one fuel to another. They should have a manual backup switch because almost every generator has a dead battery.

    • @johnnysweekends
      @johnnysweekends  ปีที่แล้ว +1

      These new units if you watch my dead battery video, I was able to start several of the Genmax units with a dead.
      And yes the solenoid need to open or close for either propane or gasoline

    • @guyin916
      @guyin916 6 หลายเดือนก่อน +1

      I used to jumpstart these off of trailer batteries when i was an equipment technician. worked like a champ.
      portable jumpstart packs didn't work all the time since they require a minimum voltage and proper polarity for safety purposes.

  • @robd117
    @robd117 4 หลายเดือนก่อน +1

    Does the T-fitting mixture adjust have any parts inside or is it just a long bolt with lock nut?

    • @johnnysweekends
      @johnnysweekends  4 หลายเดือนก่อน

      Just a long bolt and a jam nut to control flow..👍🏼

  • @tome5345
    @tome5345 3 หลายเดือนก่อน +1

    Just got the Pulsar mentioned below. It does have the internal load regulator you mentioned that keeps it from running ng. To bypass, can I simply couple the input and output hoses and rely on an external ng regulator?

    • @johnnysweekends
      @johnnysweekends  3 หลายเดือนก่อน

      So you could remove it entirely and use the kit. Or I would add a T after the regulator with a on off valve. I dont think it would back flow into the onboard regulator as once the gen starts running its pulling from the external.

    • @tome5345
      @tome5345 3 หลายเดือนก่อน +1

      @@johnnysweekends Thanks for the comment: even better I'm going to try a 3-way valve so either the propane channel or the NG channel will feed the carb; no chance of back flowing from either. Your video was extremely informative; thanks again.

  • @davecardoza9328
    @davecardoza9328 ปีที่แล้ว +1

    Johnny, thanks for this video. Do you know if this would work on the Genmax 9000ied?

    • @johnnysweekends
      @johnnysweekends  ปีที่แล้ว

      I don’t know for sure but I’m pretty sure the load regulator is inside and would need to be by passed. They have a new tri fuel coming..
      But you could make it work but that’s up to you.

    • @davecardoza9328
      @davecardoza9328 ปีที่แล้ว +1

      @@johnnysweekends Waiting for the tri fuel coming sometime soon! Thanks!

  • @robertholmes1556
    @robertholmes1556 4 หลายเดือนก่อน +1

    Great video. Would this work on a GENMAX GM4600iAEFIC ? Thank you

    • @johnnysweekends
      @johnnysweekends  4 หลายเดือนก่อน +1

      Hello, sorry I thought your were commenting on another video. No this will not work on the EFI unit

  • @philipscougale2075
    @philipscougale2075 ปีที่แล้ว +1

    I get that the first regulator that's always found on the propane line for dual fuel generators is to regulate pressure to similar levels similar to those provided by the regulator on my natural gas meter. My question is, if the Century demand/secondary regulator works for propane, why wouldn't it work for natural gas also? The only thing that seems to be missing is possibly some kind of adjustment for the amount of fuel that's allowed through.

    • @johnnysweekends
      @johnnysweekends  ปีที่แล้ว

      It does work for NG. That’s what the video shows me doing is using this kit for NG and how to set it, or can be used for a gas to LPG.

    • @philipscougale2075
      @philipscougale2075 ปีที่แล้ว +2

      I’m talking about the generators that have a demand regulator built-in like the ones you claim you would have to bypass. Why do you need to buy another regular so you can bypass the built-in one?

    • @philipscougale2075
      @philipscougale2075 ปีที่แล้ว +1

      Example, WEN DF875iX. It comes with a pressure regulator on the hose like normal and then behind the propane inlet there is a demand regulator. Is there a reason someone with this generator couldn’t just run a gas hose to the propane inlet and run with it?

    • @johnnysweekends
      @johnnysweekends  ปีที่แล้ว +4

      The internal demand regulator is set to run on the pressure and Btu ratings of LPG not NG. So the on board will probably run to lean for NG as you need more NG since its way less efficient.
      I have tried a couple with my units but they just wont run correctly.

    • @johnnysweekends
      @johnnysweekends  ปีที่แล้ว

      I commented on other post

  • @williamwacaster4870
    @williamwacaster4870 2 หลายเดือนก่อน

    I was wondering if you could share the link with me for the natural gas conversion kit you used on the genmax 3500iad? I have that same generator and would like to do the conversion like you did in the video. Thank you

    • @johnnysweekends
      @johnnysweekends  หลายเดือนก่อน

      They don’t actually make one for it. It’s a universal kit and you would have to build it a little. It’s just brass fittings and a hose. Some of the parts are listed in description

  • @undisclosed2673
    @undisclosed2673 ปีที่แล้ว +1

    It looks like that is the GM7250iEDC that has internal load regulator and won’t work without bypass correct? Do you happen to know whether GM6000iED requires bypass as well?

    • @johnnysweekends
      @johnnysweekends  ปีที่แล้ว +1

      Yes the 6000 is the same.
      You can make it work but your using the external type for both NG and LPG and bypassing the internal.
      So it would void warranty so maybe after it expires..🤷🏼‍♂️

  • @SunAndShade
    @SunAndShade ปีที่แล้ว +1

    Newbie here so I really appreciate all your info. But a bit confused. I want a small generator (1 KW) that will run on natural gas (for power outages at home). Would also be nice to run on propane (to use away from home). Have no interest in running on gasoline. All the only natural gas ones are huge. So thought of getting dual fuel. But are you saying if I want to run natural gas, it's better to start with a gasoline only generator? Thanks.

    • @johnnysweekends
      @johnnysweekends  ปีที่แล้ว +1

      You should take a look at the alp generator amzn.to/3N5nbHT
      It’s propane only, can run a very long time on a 20lb bottle and would be perfect for charging thins and more. Simple, small and getting decent reviews..👍🏼

    • @NoZenith
      @NoZenith 9 หลายเดือนก่อน

      ​@@johnnysweekendsbummer, it's gone

  • @jacalynnrolin3000
    @jacalynnrolin3000 9 หลายเดือนก่อน +1

    so is the Genmax GM3500IAED in the video already tri fuel?

    • @johnnysweekends
      @johnnysweekends  9 หลายเดือนก่อน

      No it is not. You need to add the external conversion kit and use that load regulator. Not the factory

  • @noads6566
    @noads6566 ปีที่แล้ว +1

    Do you have a link to buy this kit? And would this work on a Champion 2500W dual fuel inverter generator (model 200961)?

    • @johnnysweekends
      @johnnysweekends  ปีที่แล้ว

      Sometimes for certain model you have to go to uscarburation website or even hutch mountain.

  • @joelwingate7994
    @joelwingate7994 ปีที่แล้ว +1

    Do you know which way the pulsar 9500 inverter generator is set up? Im wanting to add natural gas abilities to it.

    • @johnnysweekends
      @johnnysweekends  ปีที่แล้ว

      Pretty sure the regulator is internal so it would need bypass which you could add a splitter after it for a second feed. But would still need a outside regulator

  • @darthraider2483
    @darthraider2483 ปีที่แล้ว +1

    Just bought a pulsar gd400bn you think this will work on it as well.

  • @robertholmes1556
    @robertholmes1556 4 หลายเดือนก่อน +1

    Will this natural gas kit work on GENMAX GM4600IAEDC ?
    What I’m looking for: is to have a lighter inverter generator below 70 lbs that is tri-fuel.
    Thank you

    • @johnnysweekends
      @johnnysweekends  4 หลายเดือนก่อน +1

      Sorry it will not. The onboard load regulator limits it. So you are double regulating and would need to by pass the internal one.

  • @vvburnvv8526
    @vvburnvv8526 ปีที่แล้ว +1

    Would this work for a dual fuel genmax 7250iedc?

    • @johnnysweekends
      @johnnysweekends  ปีที่แล้ว +1

      Not with out modifying the inside and by passing the load regulator

  • @robertholmes1556
    @robertholmes1556 4 หลายเดือนก่อน

    Do you have link to this kit?
    Thank you

    • @johnnysweekends
      @johnnysweekends  4 หลายเดือนก่อน +1

      You need to get ahold of them and get one more specific for your unit

  • @neilcomparetto5282
    @neilcomparetto5282 ปีที่แล้ว +1

    Any idea when the updated Genmax 7250 is coming out?

    • @johnnysweekends
      @johnnysweekends  ปีที่แล้ว +1

      No not yet waiting, for them to let me know when all the new units are tested and ready. Would assume soon.

    • @scramick
      @scramick 3 หลายเดือนก่อน +1

      Looking for the Genmax 7250 that can do Natural Gas. Is there a new model coming out that can do Natural gas as well? If not, do you know which regulator needed for the 7250? Thanks! @@johnnysweekends

    • @johnnysweekends
      @johnnysweekends  3 หลายเดือนก่อน +1

      @scramick I’m headed to the NHS show in Vegas next week!! There will be tons of new stuff from several manufacturers including GenMax so stay tuned for the video…😀👍🏼

    • @scramick
      @scramick 3 หลายเดือนก่อน +1

      Thank you! @@johnnysweekends

  • @jamessmith6220
    @jamessmith6220 ปีที่แล้ว +1

    I'm wondering if i can run a baja 900 inverter generator on natural gas

    • @johnnysweekends
      @johnnysweekends  ปีที่แล้ว

      Sure if it doesn’t have a internal load regulator or is not dual fuel already then it’s easy with the kit..👍🏼

  • @brianreip411
    @brianreip411 ปีที่แล้ว +1

    would you need that regulator if the generator is tri-fuel?

    • @johnnysweekends
      @johnnysweekends  ปีที่แล้ว +1

      No, tri fuel is ready to go 😀👍🏼

    • @brianreip411
      @brianreip411 ปีที่แล้ว +1

      @@johnnysweekends Thank you! In tri-fuel generators or even in that regulator. Will the flow of natrual gas stop if the generator is shut off? Just as a saftey feature if you don't notice the generator stopped running natural gas wouldn't be flowing all over the floor.

    • @johnnysweekends
      @johnnysweekends  ปีที่แล้ว +1

      Yea both the tri fuel units or dual fuel and the after market load regulator will shut off if the generator does.
      Although NG is lighter than air so it does dissipate quicker. But leaks can still be dangerous

    • @brianreip411
      @brianreip411 ปีที่แล้ว +1

      @JOHNNY'S WEEKENDS awesome thank you , it's good to know they have that saftey device built in.

  • @billaire1channel710
    @billaire1channel710 ปีที่แล้ว +1

    Genmax has a Tri fuel "natural gas" generator

    • @johnnysweekends
      @johnnysweekends  ปีที่แล้ว

      Yes they do now! I was the first to report on this and they have two models along with making some for pulsar. Genmax has several new models coming including a 120/240 volt small gen. So you can combine into parallel or series along with the new fuel injection model ..😀👍🏼

    • @billaire1channel710
      @billaire1channel710 ปีที่แล้ว +1

      @@johnnysweekends do you know when the release dates are for the US and Canada?

    • @johnnysweekends
      @johnnysweekends  ปีที่แล้ว +1

      Mr. Brown I have been talking with my contact and I think mid summer is when we should see most so then I assume another month or so till Canada gets them. It seems it’s always a couple months or less before you do.
      But the bigger V twin 12000k unit is a end of the year release from what I’m hearing.

  • @rickbraden4272
    @rickbraden4272 9 หลายเดือนก่อน

    The generator is 3200 watts rated load. Why did you adjust your natural gas regulator with only a 15 amp load?

  • @entubadao
    @entubadao ปีที่แล้ว

    That sounds dangerous. I might only being ignorant, but when you use two fuel types on the same machine, differences of pressure, volatility and others must be carefully considered.

    • @johnnysweekends
      @johnnysweekends  ปีที่แล้ว +5

      These engines are nothing more then lawn mower engines and many can be converted to LPG and NG. As long as the correct regulator and load regulator or on demand type is used then it’s perfectly safe for you and the engine.
      This is not new and has been going on for for 20 years+

  • @pacman3834
    @pacman3834 ปีที่แล้ว

    can this generator run on hydrogen instead of propane?

    • @johnnysweekends
      @johnnysweekends  ปีที่แล้ว +1

      It’s possible but it has a lower btu than NG …🤷🏼‍♂️

    • @NoZenith
      @NoZenith 9 หลายเดือนก่อน +1

      ​@@johnnysweekends😮