Toyota forklift no start issue

แชร์
ฝัง

ความคิดเห็น • 267

  • @adriancastaneda4971
    @adriancastaneda4971 8 ปีที่แล้ว +7

    I wanted to thank you for the time you spend making these videos. I'm new to this field and your videos have really help me out. Please keep up with the great work.

  • @texasfishingandfitness2621
    @texasfishingandfitness2621 2 ปีที่แล้ว +4

    Ran Into a problem like this today on an 7FGU35 and I got stuck on the diag but I remembered watching this video before and remembered something similar/doing the same thing, cranking but not turning over.. except mine was missing the spark.. awesome video bro nothing but straight facts and knowledge!!!! Keep up the videos bro u help more ppl then u know or think! All the way from San antonio TX

  • @leoveroude4492
    @leoveroude4492 8 ปีที่แล้ว +7

    Just watched your video and I have to say thank you for a video well done! I had a no start issue with my jurassic period Allis Chalmers. I had done a lot of what you showed already, but not the brake fluid into the carb trick, that is simple but effective.
    In the end what I did is clean the regulator and carb inside and out very well, propane lines too. Fired right up and got rid of my stress issues too! Thank YOU!!

    • @StanFlahautAFD
      @StanFlahautAFD 8 ปีที่แล้ว +1

      It was brake cleaner not brake fluid.  You have to be sure it is the flammable type too. If you use the CFC kind it doesn't work. Use starter fluid and be sure to stay away from the throttle body when you start it in case of flames from a back fire.

  • @Cantante1963
    @Cantante1963 ปีที่แล้ว +2

    Last comment was 7 years ago. I work driving one of this things and I’m learning a lot from your videos. Thanks.

    • @user-qh8ug5vj1h
      @user-qh8ug5vj1h 4 หลายเดือนก่อน

      Toyotaforkliftnoaselera

    • @clayton9136
      @clayton9136 วันที่ผ่านมา

      Last comment was one year before yours, and every year before that one.

  • @mrrangemaster
    @mrrangemaster 5 ปีที่แล้ว +5

    Awesome, Thanks very much for putting this on here. It makes life so much easier when it is shown the way you have just done. What a true gentlemen

  • @lw2nas
    @lw2nas 8 ปีที่แล้ว +5

    Excellent! Good logical and systematic approach on Troubleshoot the problem.

  • @dustywelker4054
    @dustywelker4054 3 ปีที่แล้ว +7

    Thank you. I recently got a job as a forklift/maintenance position after working on the production welding/fab floor for 6 yrs. I look forward to videos like this to help me in my new position

  • @jleron22
    @jleron22 4 ปีที่แล้ว +5

    Great troubleshooting techniques performed here 👍👍

  • @twotone87200288
    @twotone87200288 6 ปีที่แล้ว +3

    hey buddy, thank you for sharing. I actually was working on this same lpg regulator at work the other day. The issue I had with this particular one was with the diaphragm. apparently after awhile, the oil they put into the propane to give it its smell can clog up and keep the diaphragm from working properly.

  • @travisjohnson2753
    @travisjohnson2753 7 ปีที่แล้ว +2

    Thankyou! This will make me a hero at the shop!

    • @forkliftgeek10
      @forkliftgeek10  7 ปีที่แล้ว

      +Travis Johnson when you're spraying brake cleaner into the intake always have a fire extinguisher on hand as it may backfire. Something that I should have said in the video. Thanks for watching and always be safe.

  • @hdkirby9823
    @hdkirby9823 3 ปีที่แล้ว +2

    Thank you so much for that video I had the same issue did the same thing you did and sure enough that is the problem

  • @henrikjonsson4340
    @henrikjonsson4340 3 ปีที่แล้ว

    Thanks! Learning something new about gas-system :)

  • @andyfreeman660
    @andyfreeman660 8 ปีที่แล้ว +7

    I work for Toyota in the UK and you would be amazed the number of times we go to duel fuel trucks switched to Gas lol.

    • @carlosmafla9177
      @carlosmafla9177 7 ปีที่แล้ว

      Andy Freeman Haha same happened to me like two weeks ago

  • @johnblack4636
    @johnblack4636 8 ปีที่แล้ว +6

    Good job bro and thanks for the video;-)

  • @JustMe-JustBecause
    @JustMe-JustBecause 4 ปีที่แล้ว +3

    Great Video! My problem was one of my morons had switched the "LP to GAS" switch.
    I spent a lot of time trying to troubleshoot it and when you mentioned it, BAM! fixed :)

    • @antoniogassmann7532
      @antoniogassmann7532 4 ปีที่แล้ว

      Hola amigo tenés un email, tallerautoelevadores@gmail.com
      Y si tenés WhatsApp
      Antonio Paraná Entre Ríos Argentina

  • @bbdallas1
    @bbdallas1 3 ปีที่แล้ว +2

    Great video. Thank you for sharing

  • @raulsd.i.y.videos5585
    @raulsd.i.y.videos5585 2 ปีที่แล้ว +1

    Awesome video. Good troubleshooting.

  • @solofoto576
    @solofoto576 8 ปีที่แล้ว +1

    Really enjoyed your video thanks.

  • @jaymatias6649
    @jaymatias6649 9 ปีที่แล้ว +8

    Unfortunately, price of solenoid was more than half the price of the regulator. So might as well replace the whole thing. But still up to the customer if he wants just the solenoid. In this case he opted for the regulator.

  • @cesarvelazquez3231
    @cesarvelazquez3231 4 ปีที่แล้ว +3

    Thanks i just started working for a forklift company

  • @Juan-pt1lq
    @Juan-pt1lq 4 ปีที่แล้ว +1

    Thx for the education.

  • @gigglegasn20
    @gigglegasn20 7 ปีที่แล้ว +2

    That's a very common problem on Toyota forklifts, usually I would just put my hand on the solenoid and crank it and you will feel it if it works. If you're not getting power to that connector it's most like the relay located under the fuse box.

  • @andyfreeman660
    @andyfreeman660 8 ปีที่แล้ว +8

    the first thing to look at before you get any tools out on a duel fuel Toyota, is the truck switched to LPG if it's switched the GAS (petrol) it will crank but not start. you would be amazed how many people get cought out on this one ( myself included)

    • @AndrewSmith-pp6ir
      @AndrewSmith-pp6ir 6 ปีที่แล้ว +1

      And the switch gets bumped half way between gas and lpg sometimes which gives no start either

    • @samuelw.3992
      @samuelw.3992 ปีที่แล้ว

      No shit. That’s a good point

  • @EvanT1995
    @EvanT1995 4 ปีที่แล้ว +3

    Awesome vid. Just graduated college with a 2 year auto degree. Want to get into the forklift repair industry. Subscribed!

    • @deborahchesser7375
      @deborahchesser7375 3 ปีที่แล้ว

      Polish up on your schematic and wiring diagrams, the electric trucks are what you want to tech on. It’s good to know recip’s but electric trucks are way more field serviceable and usually cleaner. Good luck

    • @EvanT1995
      @EvanT1995 3 ปีที่แล้ว

      @@deborahchesser7375 I work for a company that services Raymond trucks and schematics and electrical in this industry I'm slowly but surely learning. Thanks for the advice. Like this industry more than cars!

    • @jamesmyers7066
      @jamesmyers7066 3 ปีที่แล้ว +1

      After 35 years in this field I can give a little advice to you new guys...don’t jump off the dock and always have a 6”adjustable wrench in your pocket!

    • @EvanT1995
      @EvanT1995 3 ปีที่แล้ว

      @@jamesmyers7066 when it comes to "jumping off the dock" what are you referring to? Lol

    • @anthonykozar9172
      @anthonykozar9172 ปีที่แล้ว +1

      @@EvanT1995 quite literally jumping off the dock to get down to your van!! haha

  • @carlitosreyes6703
    @carlitosreyes6703 4 ปีที่แล้ว

    Thank u buddy you video is nice

  • @checkenginelover
    @checkenginelover 6 ปีที่แล้ว +1

    Great vid.

  • @rudypacheco227
    @rudypacheco227 9 ปีที่แล้ว

    I have a cat gc18 no start, LPG i have changed the vaporizer and the lockoff, I also changed the oil pressure switch and I have 9 volts to the lockoff and no start, if I jump over voltage directly to lockoff the forklift starts and runs a few times, I also had battery checked by Napa and swapped starter with new and no fix, any ideas?

  • @joshteague8904
    @joshteague8904 2 ปีที่แล้ว

    Did you replace the regulator or just the selenoid only? I thought just the selenoid was suspect?

  • @NikoJones94
    @NikoJones94 ปีที่แล้ว

    Cool video!

  • @douglasparkin1026
    @douglasparkin1026 ปีที่แล้ว

    Did you install a whole new regulator or just the solenoid

  • @fernandog.aguirre2791
    @fernandog.aguirre2791 4 ปีที่แล้ว

    Great. Thank you!

  • @221180ful
    @221180ful 4 ปีที่แล้ว +1

    Excelente amigo

  • @jgmanza
    @jgmanza 9 ปีที่แล้ว +3

    Thanks!!!

  • @micheldupras7854
    @micheldupras7854 5 ปีที่แล้ว +1

    Hi Jay, what if the test light doesn't light up when you check the power going to the solenoid on that connector when cranking? Bad wiring?

    • @forkliftgeek10
      @forkliftgeek10  5 ปีที่แล้ว

      Bad relay, wiring, fuse or rev switch on positive side. If this was a dual fuel check if the switch is flicked to gasoline.

  • @tinogarcia72
    @tinogarcia72 7 ปีที่แล้ว

    I did check the 2 wires and they are good

  • @jacqueshenribien-aime3384
    @jacqueshenribien-aime3384 7 ปีที่แล้ว

    I wonder if way back I had opportunity to benefit all these training I would be an excellent Mechanic today I have to Paid to fix my vehicle for any little problem.

  • @marknicholson2718
    @marknicholson2718 6 หลายเดือนก่อน

    Did it not have gasoline in it? It's a dual fuel truck. I've Had wires break inside the insulation at terminals. Looked fine but conductor was broken.

  • @antilortiz2302
    @antilortiz2302 ปีที่แล้ว

    ok I see litle liquin from water came from radiator to conected to the regulator you think this is the problem and I have to refill radiator any 2 days thanks

  • @andyfreeman660
    @andyfreeman660 8 ปีที่แล้ว

    depending on the Gas regulator type the slow run solinoid is powered from a sensor in the distributor.
    if you have high gas flow to the carb ( mixer) the engine will crank but not start and the main valve seal inside the regulator.

    • @forkliftgeek10
      @forkliftgeek10  8 ปีที่แล้ว

      +Andy Freeman the type of regulator would depend on the model of the forklift. the regulator you are referring to would be more likely in an 8 series. As far as high gas flow, yes it would produce the same symptom but exhaust would smell of unburned propane and adding external fuel source would not get the engine to start.

  • @andycarpenter5561
    @andycarpenter5561 4 ปีที่แล้ว

    @forkliftgeek I'm having a minor issue with my Mitsubishi propane forklift. Seems lately I have to stomp the gas pedal to the floor to get it to start. Could that also be the solenoid or should i look at injectors?

    • @forkliftgeek10
      @forkliftgeek10  4 ปีที่แล้ว

      Your mitsubishi would have a different fuel system than a toyota.

  • @hawgbilly_07born_assassin88
    @hawgbilly_07born_assassin88 7 ปีที่แล้ว +1

    very helps man

  • @budiyantobong915
    @budiyantobong915 2 ปีที่แล้ว

    Hi, how much does solenoid costs in average range?

  • @peterlauzon4905
    @peterlauzon4905 2 ปีที่แล้ว

    nice encoder bearing we saw at 11.24 !!!

  • @theoffice1842
    @theoffice1842 3 ปีที่แล้ว +1

    I sprayed starter fluid and our FL started right up. It when I checked the fuel supply the gas didn’t come out as hard as yours did. It did a little more but I had to keep opening it. Any advice?

  • @scubastevesdestiny
    @scubastevesdestiny 5 ปีที่แล้ว

    Hey there. I have a tusk forklift. It is made by Komatsu. I just purchased it this morning and drove it on the trailer as well as off the trailer. While backing it off the trailer it hit the ground pretty hard and I drove it into the shop. I shut it off and it never started back up after that. The guy mentioned he cleaned the regulator to get the machine back running again. I have to assume that somehow the regulator is failing. It seems to be forcing a enormous amount of propane into the system when I turn the key key on. It acts like it wants to start but it just won't do it. Do I need to replace the entire regulator? It's blowing the excess propane out of a small vacuum size line off the side of the regulator that goes to the intake tube.

  • @JW-qd4ig
    @JW-qd4ig ปีที่แล้ว

    Hey forklift geek,
    Thank you for the fun interesting videos. I appreciate solid diagnostic work. And the explanation is spot on.
    I have a toyota 7fgcu15 with a no start, I diagnosed it to a (what I thought was a faulty shutoff solenoid) but rather a no power to the shut off solenoid issue.
    Do you know what else is on that circuit?
    It powers the solenoid through the ignition switch, but without a schematic I do not know where the solenoid connecting wires come from.
    Thank you

    • @forkliftgeek10
      @forkliftgeek10  ปีที่แล้ว +1

      th-cam.com/video/bSvOp-zRlMQ/w-d-xo.html
      This one is a 7 series, but not all 7 series are wired this way. Some of them, the lock off is powered by a rev switch and the input is from the distributor.

    • @JW-qd4ig
      @JW-qd4ig ปีที่แล้ว +1

      @forkliftgeek10 I just watched that linked video.
      I will definitely look into that.
      I bypassed the main solenoid (in the regulator) to feed it voltage so it would open. Then that is when I discovered it would run, but this video could definitely be the final culprit or at least similar to the problem that I am having.
      Thank you again for the explanation.

  • @solden49
    @solden49 6 ปีที่แล้ว

    So I have a propane floor buffer that is doing the exact same thing. It was running perfect until I dis connected the hose from the vaporizer to the carb and turned the propane valve on. I put the hose back on and now and it still will not start. I have bought a new vaporizer and solenoid and it will not start. Any ideas if that made sense?

    • @forkliftgeek10
      @forkliftgeek10  6 ปีที่แล้ว

      +Solomon Smith when an engine does not start it can only be missing a few things, spark, fuel, air, timing and compression. I'd start with spark and fuel. Check if the solenoid is getting power.

  • @thatcoolguy131
    @thatcoolguy131 6 ปีที่แล้ว

    I have this model lift won't start not get power from the fuse box to starter I'm thinking the neutral safety is bad as i have checked fuses and put in new relay but can't find neutral switch. Starts and runs fine jumping to starter.

    • @forkliftgeek10
      @forkliftgeek10  6 ปีที่แล้ว +1

      +thatcoolguy131 neutral switch is part of the directional lever assembly.

  • @WarrenStarCat
    @WarrenStarCat 4 ปีที่แล้ว

    This is good info, but we are dealing with a newer generation Regulator with dual solenoid lockouts. Getting an intemittent, NO START after the rig sits for a while. Same as yours it will try to run with starting fluid. Also breaking the flare connection coming out of the big lockout solenoid path, bleeding off some pressure and re-tightening may allow it to start. The Attending Forklift is also Puzzled by this one. S/N is 41051 Model 8FGU25.
    Any suggestions are helpful.
    Star

    • @forkliftgeek10
      @forkliftgeek10  4 ปีที่แล้ว

      Sometimes the main solenoid (big one in the middle) gets stuck or the solenoid is already weak. When it is not starting try tapping on the solenoid and see if it starts.

    • @WarrenStarCat
      @WarrenStarCat 4 ปีที่แล้ว +1

      @@forkliftgeek10 Thanks for the info. 10-4

    • @WarrenStarCat
      @WarrenStarCat 4 ปีที่แล้ว +1

      OK Excellent. Tap on the secondary lockout on the REG when cranking and it start right up after prolonged NO START. Good Technique. Thanks. New Reg should solve this one.

  • @antilortiz2302
    @antilortiz2302 ปีที่แล้ว

    thanks for video I have question mi forklift regulator is frozen every 15 minutes and the forklift shut down after desfrozen forklift run again justo do this just when is cold once when the forklift warm up running good all day now I can running only 15 minutes thanks

    • @forkliftgeek10
      @forkliftgeek10  ปีที่แล้ว

      Check your coolant level in the radiator

    • @antilortiz2302
      @antilortiz2302 ปีที่แล้ว

      ok I see litle liquin from water came from radiator to conected to the regulator you think this is the problem and I have to refill radiator any 2 days thanks

  • @FleetTech97
    @FleetTech97 3 ปีที่แล้ว

    Hey man I have a Toyota. I sprayed starter fluid inside and it just cranks and tries to start but never catches. It’s got spark but it looks a little weak. Could it be the distributor cap? It’s got new plugs in it.
    What should I look fir on the cap ?

    • @forkliftgeek10
      @forkliftgeek10  3 ปีที่แล้ว

      Worn contacts in the cap. The cap is not the only part that produce a weak spark though. The rotor, ignition coil, ignition module, and cables are all suspect.

  • @mikesecondo2254
    @mikesecondo2254 4 ปีที่แล้ว +9

    Been a field service technician for 25 years..got 2 years left..then retirement...thank God...lift trucks are getting more complex!!!

    • @deborahchesser7375
      @deborahchesser7375 3 ปีที่แล้ว

      I’m thinking about getting back into it, I was a Raymond tech so I’m used to reading schematics and diagrams. Not sure if the body can handle it though. Good luck on retirement brother, enjoy

    • @mikesecondo2254
      @mikesecondo2254 3 ปีที่แล้ว

      @@deborahchesser7375 I am presently employed by a Raymond dealer as a field technician.

    • @THEDARK3BLUETEAMS
      @THEDARK3BLUETEAMS 2 ปีที่แล้ว

      Capture Troubleshoot

    • @richardnardella2553
      @richardnardella2553 6 หลายเดือนก่อน

      raymond in anchorage alaska sucks they are the worst come take the asshole who runs service out of here rob doesn’t know how to treat his customers or how to shut his mouth we won’t buy anymore raymond crap here

  • @jesuszaragoza6554
    @jesuszaragoza6554 6 หลายเดือนก่อน

    I have a 7 series with an issue that when I’m on the throttle it work but then let off the throttle it shuts off. I have spark , and propane . I do have the regulator it is full of tar . Any ideas before I replace the regulator

    • @forkliftgeek10
      @forkliftgeek10  6 หลายเดือนก่อน +1

      Throttle plate might be gummed up

  • @barrygirky8194
    @barrygirky8194 7 ปีที่แล้ว

    I have a hyster 80 that wont start. I know am not getting spark. replaced the coil, distributor cap and rotor, and the boss man had me change the starter??? but I cant get spark from the coil. can you help me?

    • @forkliftgeek10
      @forkliftgeek10  7 ปีที่แล้ว

      +Barry Girky does it have a gm engine with the bypass system?

  • @kenzieneal8476
    @kenzieneal8476 3 ปีที่แล้ว

    Excellent

  • @andyfreeman660
    @andyfreeman660 8 ปีที่แล้ว

    nice presentation

  • @cbenpictures
    @cbenpictures 8 ปีที่แล้ว +2

    Love your process of elimination, you should consider teaching.

  • @garycastle1477
    @garycastle1477 7 ปีที่แล้ว

    Great Job, I have one 5fgcu20, gets spark with key start, has good compression, cap, wires double checked, will only stumble on start, fuel is controlled by vacuum only on this one, big clue is it wont run with starting fluid in air intake. does this sould like distributor or exciter/coil, I got this job to help these guys out and got it started by jumping the relay the guy before me cut the neutral saftey switch out of the harness, so i was lost with wires dangling and off the start relay, figured most of it out without schematic, got it to start with jumper to relay, started everytime one pop, so i fixed the hydralic cylinder for side shift, installed new key switch, repaired altenator lower mount bolt broken in cover, hood hinges repaired, rewired as best i could they way it was running and now it won't start only stumbling with fuel open, Any Idea?

    • @forkliftgeek10
      @forkliftgeek10  7 ปีที่แล้ว

      +Gary Castle pull out the hose from the regulator to the mixer. When cranking the engine there should be no gas coming out, if there is then it's flooding the engine. You could also check the butterfly on the governor, I've seen it before that when the engine vacuum increases it pulls it shut due to a broken spring. Ignition wise I usually use an ignition tester and set it to 30kv. If it's not able to jump that gap then I'd check for high resistance in the secondary circuit.

    • @garycastle1477
      @garycastle1477 7 ปีที่แล้ว

      thanks for reply, good thing to look at, I checked the two units out the bottom unit looked new and shinny, had small amount of black dust inside that side, the upper had some waxy stuff but not clogging anything and the vacuum seemed to activate the switch to open valve to let LPg thru. The broken spring you mention is that in the upper or lower unit of this regulator mixer ? I have gotten spark from plug but its a very small bluish white spark that is not that strong cause the shock wasn't that bad! The plug wire 4 is bad and is getting replaced
      asap, but others were ok and stronger. Would that spring stop it from running on starter fluid? This is why I think its ign. THANKS FOR REPLYING. Really Appreciate it. Gary

    • @forkliftgeek10
      @forkliftgeek10  7 ปีที่แล้ว

      Top unit u are referring to is the lock off and the bottom unit is the regulator. The mixer is on top of the intake manifold. On the mixer side (carburator) there is another butterfly which is spring loaded. Shoot me your email so I can send some diagrams.

    • @jturkish
      @jturkish 6 ปีที่แล้ว

      Gary Castle noon

  • @jasonvargas4611
    @jasonvargas4611 5 ปีที่แล้ว

    I have a early 90's Clark lp forklift it wont start without a shot of starting fluid. Any ideas? Thanks

    • @forkliftgeek10
      @forkliftgeek10  5 ปีที่แล้ว +1

      Well, if it keeps running after that a vacuum leak would be a good place to start. Assuming that the fuel system is vacuum operated. Poor Ignition may also be a cause.

    • @jasonvargas4611
      @jasonvargas4611 5 ปีที่แล้ว

      @@forkliftgeek10 thanks for your reply, will check into that.
      Some days it fires up just fine with no help🤷‍♂️

  • @Sam-lk6eo
    @Sam-lk6eo 2 ปีที่แล้ว

    Hi, Buddy at the end you said you changed the regulator not the solenoid, I thought you determined the fault as being the solenoid, Or is it that in order to change the solenoid you have to do it with a new regulator and solenoid attached ?

    • @forkliftgeek10
      @forkliftgeek10  2 ปีที่แล้ว

      Customer opted to change the regulator

  • @tinogarcia72
    @tinogarcia72 7 ปีที่แล้ว

    ok that's what it said she on the wiring diagram and didn't know where the engine rev sw was located so I need to replace the distributor or can I just replace the engine rev sw is there any picture of it
    thank you

    • @forkliftgeek10
      @forkliftgeek10  7 ปีที่แล้ว

      +agustin tirado I would suggest checking the integrity of the wiring first.

    • @tinogarcia72
      @tinogarcia72 7 ปีที่แล้ว

      i did check everything and still wont start

    • @forkliftgeek10
      @forkliftgeek10  7 ปีที่แล้ว

      +agustin tirado are you sure fuel is what you are missing?

    • @tinogarcia72
      @tinogarcia72 7 ปีที่แล้ว

      any other idea

  • @tangkokaun4383
    @tangkokaun4383 4 ปีที่แล้ว

    Sir my is toyota diesel engine 6 sparks also cannot start how to do

  • @honi9
    @honi9 8 ปีที่แล้ว

    wondering if you can help? I have a forklift which is a Henley husky 12 which has a ford 4cyl 2711e convert with a beam 120a propane system. The problem I have is that the forklift runs fine when shescold and just been fired up, though when she gets hot after say 10mins she begins to struggle to rev properly like she is struggling to get fuel. you can put full throttle and she just sits all lumpy at idle revs struggling to do anything. then out of the blue she will pull through and rev normal for a few secs and then die off again. if I let her cool down for 15mins she will fire up again as normal until she gets warm and then do the same thing again. bare in mind shes an old girl so the engine runs a little hot anyway so im wondering if its too much heat causing this as the regulator we have the beam 120a is so hot that you can barely touch it... Im wondering what you can advise?

    • @forkliftgeek10
      @forkliftgeek10  8 ปีที่แล้ว

      +honi9 when it's acting up you could try what I did here and spray some carb cleaner or brake clean into the intake and see it runs any better, if it does then you are probably right that it's lacking fuel. Be careful though in using an external fuel source as it might backfire and if you sprayed too much into the intake it might catch fire.

    • @forkliftgeek10
      @forkliftgeek10  8 ปีที่แล้ว

      +honi9 does the regulator have a primer button? Sorry not familiar with beam regulators.

    • @honi9
      @honi9 8 ปีที่แล้ว

      ForkliftGeek why is it only doing this when the thing warms up after 10mins running though. plus why is the regulator/mixer (beam120a) so bloody hot to touch?surely the coolant feed into themixer shouldn't heat it that much? could that be the problem? is it getting so hot the diaphragm is going all to shit with the heat. then when its cool the diaphragm is fine again? this is about the level of my grasp on the situation...

    • @forkliftgeek10
      @forkliftgeek10  8 ปีที่แล้ว

      +honi9 what does your temperature gauge indicate when it starts acting up?

    • @honi9
      @honi9 8 ปีที่แล้ว

      i will check next time ok

  • @australiaaustralia6412
    @australiaaustralia6412 5 ปีที่แล้ว

    Great job responsibilities are there

    • @sikopapouomalo9662
      @sikopapouomalo9662 4 ปีที่แล้ว

      He don't know how to work on propane forklifts

  • @maxwelmurtala4044
    @maxwelmurtala4044 2 ปีที่แล้ว

    This is very interesting

  • @busfairnitrometh
    @busfairnitrometh 6 ปีที่แล้ว

    Im working on a 8series Toyota forklift with a code e 09-1 and will not start. Any ideas

    • @forkliftgeek10
      @forkliftgeek10  6 ปีที่แล้ว

      +busfairnitrometh 09-1 is ignition signal abnormality. No spark?

    • @joepacheco4038
      @joepacheco4038 5 ปีที่แล้ว

      Broken wire tach sensor

  • @forkliftgeek10
    @forkliftgeek10  9 ปีที่แล้ว

    Why only 9v? I'm assuming you have a fully charged battery. That's a big voltage drop. I'd start there.

    • @MAKSIVICHANE213
      @MAKSIVICHANE213 7 ปีที่แล้ว

      ForkliftGeek workn on 8fgcu32. alternator not charging. checked 3 wires on alternator. yellow gets 12v. white with blue wire 12v but red wire nothn. fuses is good. where do red wire go?

    • @forkliftgeek10
      @forkliftgeek10  7 ปีที่แล้ว

      +Mak Sivichane 10A IG fuse same fuse for the charge indicator light

  • @frankstromboili5482
    @frankstromboili5482 8 ปีที่แล้ว

    I have a 7FGCU20 that won't start when hot unless you relieve fuel pressure from line. any ideas?

    • @forkliftgeek10
      @forkliftgeek10  8 ปีที่แล้ว

      +Frank Stromboili when it's not starting pull the hose form the regulator going to the mixer. If you feel any pressure when cranking the engine then your regulator is faulty.

    • @billjarred7531
      @billjarred7531 5 ปีที่แล้ว

      I'm a Toyota tech. Its most likely the regulator. They seem to have a service life of about 7 years in my experience. Once they need adjustment its soon time for replacement on the 7-series trucks in my experience.

  • @user-cr6gh5vp3d
    @user-cr6gh5vp3d 6 ปีที่แล้ว

    wise man

  • @chrisl1636
    @chrisl1636 10 หลายเดือนก่อน

    This just come up on my for you page- it is easier to remove lp vapor hose from mixer and stick in a cup of water and crank engine, if water bubbles you have fuel as long as solenoid clicks

  • @ezzeddinezahi6847
    @ezzeddinezahi6847 4 ปีที่แล้ว

    Awesome

  • @cajememillan5800
    @cajememillan5800 ปีที่แล้ว

    Can I test that plunger out side with a powerprobe?

  • @tobybrewer2439
    @tobybrewer2439 5 ปีที่แล้ว

    Got a s50ft no fuel new regulator getting fuel to the solenoid but not past would that be the problem

    • @forkliftgeek10
      @forkliftgeek10  5 ปีที่แล้ว +1

      Make sure the solenoid is getting power and ground

    • @tobybrewer2439
      @tobybrewer2439 5 ปีที่แล้ว

      You the man broken ground wire thanx so much

  • @shenchen4810
    @shenchen4810 3 ปีที่แล้ว

    What's the reason that gas accelerator doesn't react

  • @559TheAndrew
    @559TheAndrew 2 ปีที่แล้ว

    Hey if the truck didn’t start with brake clean, what would be you next step?

    • @rodneyleboeuf164
      @rodneyleboeuf164 ปีที่แล้ว

      If it didn’t start with break cleaner then that would suggest a ‘no spark’ problem. Such as spark plug problem, ignition problem, coil problem.

  • @StanFlahautAFD
    @StanFlahautAFD 8 ปีที่แล้ว +6

    stay out of the line of fire when you start it after spraying starter in the intake. If it has jumped time a backfire will blow your doors off.

    • @samuelw.3992
      @samuelw.3992 ปีที่แล้ว

      Definitely. I had it blow a huge fireball out once lol

  • @willcojak9650
    @willcojak9650 2 ปีที่แล้ว

    thanks.

  • @ellie9571
    @ellie9571 6 ปีที่แล้ว

    hi i have a problem with tcm 3.0 ton diesel forklift.(i think 1992).key ignition turns on but no start.It starts if i use screwdriver on starter first time.What is wrong?Starter is fine.had it checked.

    • @forkliftgeek10
      @forkliftgeek10  6 ปีที่แล้ว

      +crazy pineapple where did you use the screwdriver on?

    • @forkliftgeek10
      @forkliftgeek10  6 ปีที่แล้ว

      +crazy pineapple im guessing you jumped the battery connection on the starter to the starter solenoid with a screwdriver. If this is the case then everything from the key switch, relay, and wiring upto the starter are suspect. Corrosion in the connectors is also a possibility.

  • @muhammadattique6230
    @muhammadattique6230 ปีที่แล้ว

    Good 👍

  • @tinogarcia72
    @tinogarcia72 7 ปีที่แล้ว

    i have this problem engine starts and then dies check the regulator valve relay and is not working theres no ground to the relay to activated the relay and the solenoid on the regulator where this ground supply from

    • @forkliftgeek10
      @forkliftgeek10  7 ปีที่แล้ว

      +agustin tirado if you're talking about the lock off solenoid then ground could either be provided by the ecm or constantly from the chassis.

  • @adamadam-mq6im
    @adamadam-mq6im 5 ปีที่แล้ว

    hi any idea where to buy toyota forklift diagnostic software ?

    • @forkliftgeek10
      @forkliftgeek10  5 ปีที่แล้ว

      Intella sells the 8 series analyzer

  • @ayerimosfox
    @ayerimosfox 5 ปีที่แล้ว

    Will this solution also work for a conversion kit for automobile use?

    • @forkliftgeek10
      @forkliftgeek10  5 ปีที่แล้ว

      As far as testing if you are having a fuel problem, yes.

    • @danieloriaku6624
      @danieloriaku6624 3 ปีที่แล้ว

      I suppose so, since it's all based on the same principle.

  • @boater35
    @boater35 4 ปีที่แล้ว

    I’m desperate for help. I recently purchase a Toyota 42-4FGC25 lpg forklift. I purchased it at an auction and it ran perfectly fine. I transported it my shop and I can’t get it to start. It has spark. The forklift was at sea level and I’m now at 4700’ elevation. I’m assuming I have a fuel mixture problem. I tried messing with the screw on the top of the regulator and I can get it to where it almost starts but can’t get continuous combustion. I’m unfamiliar with lpg fuel systems. Any help would be greatly appreciated. I purchased a new battery so it should have plenty of voltage. Thank you.

    • @forkliftgeek10
      @forkliftgeek10  4 ปีที่แล้ว

      How far does the spark jump? Lpg is a gas and requires higher kv to ignite. Is the lpg lock off vacuum operated or solenoid controlled?

    • @boater35
      @boater35 4 ปีที่แล้ว

      It’s vacuum operated. Tester shows spark but I doubt the spark is the problem. It ran fine at sea level and when I brought it to the shop later the same day @ 4700’ elevation I can’t get it to start.Is there a way to send you video?

    • @forkliftgeek10
      @forkliftgeek10  4 ปีที่แล้ว

      Ok, if its fuel try spraying carb cleaner or brake cleaner into the intake, see if it starts. There could also be too much fuel flooding the engine.

    • @boater35
      @boater35 4 ปีที่แล้ว

      I got it running. It was a fuel problem. Had not leaned out the regulator enough. Thank you very much for replying. It’s extremely appreciated.

  • @sc0tte1-416
    @sc0tte1-416 7 ปีที่แล้ว +3

    Why replace the whole regulator if it was just the solenoid?

    • @forkliftgeek10
      @forkliftgeek10  7 ปีที่แล้ว +4

      +sc0tte1 solenoid cost more than half of price of regulator. Customer opted for new one.

    • @joepacheco4038
      @joepacheco4038 5 ปีที่แล้ว

      Regulator diaphragm fill with oil most likely double labor replace assembly warranty is a wonderful thing

  • @robe5000
    @robe5000 9 ปีที่แล้ว +1

    Had to install a completely new reg for a bad solenoid!? Dam

    • @johnlangdon5784
      @johnlangdon5784 8 ปีที่แล้ว +2

      +Robert Perry Ah ha! Thank you! I was getting confused by the term regulator when it was the lockoff that was the problem. *click* The lockoff is in the regulator on this machine.

  • @tinogarcia72
    @tinogarcia72 7 ปีที่แล้ว

    yes the lock out solenoid relay that supplys power to the lock solenoit theres no grount to the relay to ctivate the lock out solenid i replace the ecm and still the same problem

    • @forkliftgeek10
      @forkliftgeek10  7 ปีที่แล้ว

      +agustin tirado is this a toyota?

  • @chriskrefft3284
    @chriskrefft3284 5 ปีที่แล้ว

    What test light are you using?brand and model# please?

    • @forkliftgeek10
      @forkliftgeek10  5 ปีที่แล้ว

      It's a matco test light but I don't remember the model.

    • @chriskrefft3284
      @chriskrefft3284 5 ปีที่แล้ว

      I'm just getting started in the forklift mechanic trade. Well for about a year now as a PM Tech. But they are now letting me go out to service calls. So I've been building my tools accordingly. I have a matco test light and it is 12, 24, 48 volt. Test light but somebody said it was not good for what we do. So just trying to figure out what one is the right one.

    • @forkliftgeek10
      @forkliftgeek10  5 ปีที่แล้ว

      Honestly, it all depends on what you use it for. If its LED and you use it on solenoids, injectors or contactors then you will more likely fry the test light.

    • @chriskrefft3284
      @chriskrefft3284 5 ปีที่แล้ว

      So standard bulb is better. What about voltage range? And also was wondering about your fuel pressure tester? Any good recommendations?

    • @forkliftgeek10
      @forkliftgeek10  5 ปีที่แล้ว

      I just use a test light for quick testing on 12v systems other than that is a meter or an oscilloscope. My fuel pressure tester is from impco.

  • @amzilyoussef8080
    @amzilyoussef8080 10 วันที่ผ่านมา

    Hello، my forklift don't start and hydraulic system not work also i Do not have current to my starter relay and when i took wire direct from positive battery to positive relay it's start but hydraulic system don't work.
    Can you help me please

  • @SergioCruz-ji3jy
    @SergioCruz-ji3jy 8 ปีที่แล้ว

    I'm having the same problem but with a Nissan it cranks but won't start any ideas what it could be?

    • @forkliftgeek10
      @forkliftgeek10  8 ปีที่แล้ว

      If it cranks with normal speed then one or more of the following would be missing. Spark, fuel, compression, air (being sucked in). If all of these are present then it would be timing( ignition or cam/crank).

    • @MrSfbsnyder
      @MrSfbsnyder 6 ปีที่แล้ว

      if you have spark and no error codes, lp regulator is over pressurizing

  • @menachemize
    @menachemize 5 ปีที่แล้ว

    I was using my take fork lift for 3 hours with no issue then I go and park it and try using it again but the engine now shuts down when put in drive or reverse any ideas why?

    • @forkliftgeek10
      @forkliftgeek10  5 ปีที่แล้ว

      That could be a lot of things. Without knowing what truck it is, I would start with what is missing when it dies, spark or fuel. You would need a schematic to look for an engine shut down circuit. Is this a Clark?

    • @menachemize
      @menachemize 5 ปีที่แล้ว

      ForkliftGeek thanks for responding.
      It only dies once I switch to drive or reverse the propane tank is full.
      I just let it run for 10 minutes and after it was able to go in drive with out shutting down but it seems like I need to let it run for 10 min each time I want to use it

    • @menachemize
      @menachemize 5 ปีที่แล้ว

      It’s a yale forklift

    • @forkliftgeek10
      @forkliftgeek10  5 ปีที่แล้ว

      Well, from what you are telling me it seems to be temperature related. Still need to determine what is missing when it dies either spark or fuel since it can't be timing nor engine breathing. I had a clark that had the same symptom and it turned out to be the computer but every system is different.

  • @tinogarcia72
    @tinogarcia72 7 ปีที่แล้ว

    Yes what happens is that engine starts then dies right of way won't stay running the rally that activate the fuel cut off valve won't stay on if I by pass it it will run bud on lean mode

    • @forkliftgeek10
      @forkliftgeek10  7 ปีที่แล้ว

      +agustin tirado what do you mean when you said lean mode?

    • @tinogarcia72
      @tinogarcia72 7 ปีที่แล้ว

      can you pm me at tinotirado@yahoo.com

  • @gabrieltorresmatamoros4332
    @gabrieltorresmatamoros4332 2 ปีที่แล้ว

    Como que car el tiempo del encendido del montacargas

  • @mattsan70
    @mattsan70 ปีที่แล้ว

    I'm confused - you didn't show that the solenoid was getting a good ground to operate it - just +12v on both sides of the coil. to me that suggests a relay up stream is faulty more than anything on the regulator

    • @forkliftgeek10
      @forkliftgeek10  ปีที่แล้ว

      Yes I did. At 4:58 in the video, my test light is clamped to the battery positive so when it is lit from the connector it means I have a good negative. Transferring my t pin to the other side of the connector and have the test light lit verifies that my coil is not open.

  • @777hdt
    @777hdt 3 ปีที่แล้ว

    Lol fitted a hole new reg as it wasn’t just the solenoid.

  • @karloslerma7851
    @karloslerma7851 8 ปีที่แล้ว

    No power to relay , where do I check next ?

  • @TTLLOGIC
    @TTLLOGIC 8 ปีที่แล้ว

    Current draw measurement would have told you everything you needed to know.

    • @forkliftgeek10
      @forkliftgeek10  8 ปีที่แล้ว +1

      If you know the current draw of the coil then yes. Using a current clamp with an oscilloscope could have shown a current ramp and possibly a hump suggesting it was opening. Wanted to stay with basic tools for this one. Tnx.

  • @delbyshernandez.insurance
    @delbyshernandez.insurance 8 ปีที่แล้ว

    Hello Sir I have a problem with toyota 8FGU25. The engine fail and the aceleration is up nd down every time, I can see two error code E-03-1 and E-01-3, Please help me to solve this problem.

    • @forkliftgeek10
      @forkliftgeek10  8 ปีที่แล้ว

      E03-1 is an intake pipe pressure sensor open. Check your connections on the map sensor. E01-3 is a rich condition. Go with the E03-1 first. Check also for a vacuum leak.

  • @gigglegasn20
    @gigglegasn20 7 ปีที่แล้ว

    What else could it be if the solenoid is working and still no start? I have fuel pressure to the regulator. This happens to me every once in a while where the solenoid is good and is working but it still won't run with out starting fluid

    • @forkliftgeek10
      @forkliftgeek10  7 ปีที่แล้ว

      +gigglegasn20 have you checked the slow solenoid?

    • @gigglegasn20
      @gigglegasn20 7 ปีที่แล้ว

      ForkliftGeek what's a slow solenoid? I noticed on some Toyota models there is a second smaller solenoid on top, and some models don't have one just a vacuum line going in. Can you give me a list on what you would check when you're not getting fuel. The company I work for has about 30 Toyota lifts and every once in a while this same scenario happens and I feel like an idiot cuz I can't figure it out lol. Thanks for you help, great video BTW

    • @forkliftgeek10
      @forkliftgeek10  7 ปีที่แล้ว

      +gigglegasn20 that's the slow solenoid, some are electric and some are vacuum operated. Best thing to do is check regulator compared to specification if problem is intermittent. Do u have the manuals for them?

    • @gigglegasn20
      @gigglegasn20 7 ปีที่แล้ว

      ForkliftGeek oh okay. Only manuals we have are the owners that come on the back of the seats

    • @forkliftgeek10
      @forkliftgeek10  7 ปีที่แล้ว

      +gigglegasn20 what's the model of truck u working on?

  • @efraindlcerda2860
    @efraindlcerda2860 5 ปีที่แล้ว

    Where can i go to school to learn forklift repair?

    • @forkliftgeek10
      @forkliftgeek10  5 ปีที่แล้ว

      If you are in Canada, you need to be employed as an apprentice first before being accepted into school. Don't know about other countries though.

  • @kb1sxv
    @kb1sxv 3 หลายเดือนก่อน

    The engine has to rotate fort the solniod to pull in