Paano basahin ang 9 leads 3 phase motor terminal connection

แชร์
ฝัง
  • เผยแพร่เมื่อ 10 ก.ย. 2024
  • Matututnan natin dito ang ibat ibang application ng 9 leads 3 phase motor terminal connection gaya ng pagconnect ng low voltage, high voltage at pagconnect ng part winding motor starter. Matututunan din ang tamang boltahe na dapat gamitin.

ความคิดเห็น • 65

  • @bwielectrician992
    @bwielectrician992 2 ปีที่แล้ว +1

    Full support.....thanks for sharing idea

  • @danzelwesingtone7413
    @danzelwesingtone7413 2 ปีที่แล้ว +1

    Salamat Sir

  • @venzenpili
    @venzenpili 3 ปีที่แล้ว +1

    thank you po master sa dagdag kaalaman,marami po kayo matutulungan.godbless po

  • @georgegillbarrientos8288
    @georgegillbarrientos8288 ปีที่แล้ว

    Salamat master napakalinaw mo po magturo God bless u sir

  • @boybravo689
    @boybravo689 3 ปีที่แล้ว +1

    Well explained sir tnx more power

  • @simpliciocamirino2271
    @simpliciocamirino2271 3 ปีที่แล้ว +1

    Salamat sa sharing boss.

  • @ianrosal1235
    @ianrosal1235 3 ปีที่แล้ว +1

    sir request lang po ako yung paano iconvert ang 3phase na wye at delta connection sa single phase.salamat po☺

  • @leonardotorres4721
    @leonardotorres4721 3 ปีที่แล้ว +1

    sir magkaiba ba ang bilis ng ikut ng motor,,,sa high voltages at low voltage salama aa sagut sir kailangan ko kasi malaman

  • @moonlove8593
    @moonlove8593 2 ปีที่แล้ว +1

    Good day Sir, ask ko lang po yung low and high voltage po na nasa nameplate. hindi ko lang po maintidihan bali pagsinabing low voltage yung 230 Volts ay papasok doon each sa tatlong wire (L1= 230V, L2=230 V, L3=230V, at pag high voltage ay 460 each. Maraming salamat sa sagot ninyo.

  • @mariacrismayugba1418
    @mariacrismayugba1418 3 ปีที่แล้ว +1

    Good morning sir.. Patulong nmn po bka pd nio po itopic ung wye delta ing complete po ung meron auto at manual at float swich at ung alternate running ng pimp na wye delta

  • @josephdepedro4959
    @josephdepedro4959 2 ปีที่แล้ว +1

    Sir Tanong kulng sir diba naka wye low voltage ka sur pwedi ba gamitin sa delta Yan sir salamat

  • @jhojoenriquez8681
    @jhojoenriquez8681 3 ปีที่แล้ว +1

    sir ask q lang..papano po qng wla nang mga code ung linyang lumabas sa motor box connection nia..papano po ba sya ma lalaman na ndi ka ma liligaw ng koneksyo..tapos wla din sya diagram..papano po kaya ma lalaman o i kokonek un..pa sagot naman po..salamat

  • @alexandriavillarido4728
    @alexandriavillarido4728 3 ปีที่แล้ว +1

    Sir ang tapping connection ng control nito na pang star delta pwede bang gamitin?

  • @alexalmenario9181
    @alexalmenario9181 3 ปีที่แล้ว +1

    Good morning sir ang ibigsabihin po b starting lng po b ang double wye bago mag single wye. Ganon po b sir? Salamat po sa sagot sir

  • @joeycrisostomo5910
    @joeycrisostomo5910 3 หลายเดือนก่อน

    sir pag part winding starting connection isa lng gagamitin sa 220v standby muna yun isang winding alin man sa dalawang wye connection ty.

  • @rmascarinas47
    @rmascarinas47 3 ปีที่แล้ว +1

    papano po mag identify kung ang 9leads ay walang tagging or numbering?pls share with us youy video.Thanks

  • @marianitoerispe5203
    @marianitoerispe5203 3 ปีที่แล้ว +1

    sir magandang araw po, tanong ko lng po kung pwede bang gawin ang 9 leads out na motor sa delta connection? maraming salamat po .

  • @M3pcp
    @M3pcp 23 วันที่ผ่านมา

    yung terminal ko sir hindi naka label sa T1 to T9,,,,, U V W

  • @joelquinto7590
    @joelquinto7590 3 ปีที่แล้ว +1

    Sir baka pwd patulong..First time ko kasi magconnect ng 3phase 12 leads induction motor..Kahit diagram lang po sana..Salamat po in advance sir.

  • @joeycrisostomo5910
    @joeycrisostomo5910 3 หลายเดือนก่อน

    sir, pag namali yun khit isang connection mag high temperature lng sya po ba slmt.at sa connection po wye delta lng yun application hindi pd yun delta connection tama po ba ty.

  • @avelonestoesta6128
    @avelonestoesta6128 3 ปีที่แล้ว +1

    Parequest po sir, logo soft paano mg program/plc po. Salamat sana mapansin

    • @TagalogElectricaltips
      @TagalogElectricaltips  3 ปีที่แล้ว

      Di ko kabisado logo soft, kung gusto mo omron zen at schneider Zelio, kabisado ko. Parehas lng din yung mga yun

    • @marlonmendoza6250
      @marlonmendoza6250 3 ปีที่แล้ว +1

      Sir baka po may hiring po kau nid ko po ng work graduate po ako ng electrical engineering.tenks po

    • @avelonestoesta6128
      @avelonestoesta6128 ปีที่แล้ว

      @@TagalogElectricaltips sige sir un nlang omron

  • @eduardandrademixvlog2292
    @eduardandrademixvlog2292 ปีที่แล้ว

    Sir tanong kolang po pariho po ba ang dami ng ikot ng mga winding ng 3 peace motor hidi katolad ng electric fan na mas marami yong number one kaysa sa number 2 at 3

  • @mariacrismayugba1418
    @mariacrismayugba1418 3 ปีที่แล้ว +1

    Good morning sir.. Delta connection po dati.. Paano po b ung pag step up to wye. At paano din po ung step down to delta 240 v

  • @jthk-pop2605
    @jthk-pop2605 3 ปีที่แล้ว +1

    Sir pano naman kaya yong 12 lead out pano mag wiring ng wye delta connection🙂

  • @bugoyjavier5934
    @bugoyjavier5934 2 ปีที่แล้ว +1

    Sr ask ko ln pede b gawen delta Yan ty

    • @TagalogElectricaltips
      @TagalogElectricaltips  2 ปีที่แล้ว +1

      karamihan sz motor ay nka design ng delta sa running. ang Y ang pangstart lng kdlasan. pero meron din nman nkadesign n Y sarunning pero bihira

    • @bugoyjavier5934
      @bugoyjavier5934 2 ปีที่แล้ว

      @@TagalogElectricaltips ty

  • @kakwago1510
    @kakwago1510 3 ปีที่แล้ว +1

    Paano po pag delta connection same lang po ba

  • @brucedavis823
    @brucedavis823 ปีที่แล้ว +1

    Kapag ganyan po ba dual voltage low voltage at high voltage pwede po rin bayan i wye delta connection sir? Kung supply voltage sa site ay 400v?

    • @TagalogElectricaltips
      @TagalogElectricaltips  ปีที่แล้ว

      di pwdeng wye delta

    • @brucedavis823
      @brucedavis823 ปีที่แล้ว +1

      @@TagalogElectricaltips salamat po sir nalinawagan nako..👍👍

    • @brucedavis823
      @brucedavis823 ปีที่แล้ว

      Sir kapag po ba sinuplayan ko ang delta ng 400v posible po ba masunog ang motor?

  • @dandoymiller2671
    @dandoymiller2671 ปีที่แล้ว

    Paano magtesting ng resistance sa tatlong wires yellow wire at black wire at red wire submersible pump franklin brand...ano ang yellow wire at ano ang black wire at ano ang red wire

  • @boybravo689
    @boybravo689 3 ปีที่แล้ว +1

    Sir ask lng po meron po bang motor na 12 leads out pero angmagtetetminate sa termination box ay yong electrician na kng ano ang configuration ng motor sir

    • @TagalogElectricaltips
      @TagalogElectricaltips  3 ปีที่แล้ว

      Meron, actually gumagawa n ko ng tutorial nun, ilalabas ko soon

    • @boybravo689
      @boybravo689 3 ปีที่แล้ว +1

      @@TagalogElectricaltips Sir ask ko lng ang motor na may 6 9, 12 leads pwedeng gamitin syang wye delta starter tnx sir

    • @darrenroydelaminez1008
      @darrenroydelaminez1008 3 ปีที่แล้ว

      @@boybravo689 yan din ang tanong ko master, hindi daw pede sa wye delta control

    • @boybravo689
      @boybravo689 3 ปีที่แล้ว

      @@darrenroydelaminez1008 pwede cguro darren kasi maiiconfigure mo sya wye delta yong motor maliban na lng kng walang available na supply na 3 phase sa lugar tnx

    • @darrenroydelaminez1008
      @darrenroydelaminez1008 3 ปีที่แล้ว

      @@boybravo689 low voltage naman siya master 220v

  • @arnelgarro23
    @arnelgarro23 11 หลายเดือนก่อน

    pano ho ma identify ang 9 leads dual voltage nawala ho kase tagging nya .salamat

  • @ryanvalendez1387
    @ryanvalendez1387 3 ปีที่แล้ว +1

    Sir yng formula nang 9 leads motor same rin ba sa 6leads motor thks

  • @froelynmaeresula4124
    @froelynmaeresula4124 2 ปีที่แล้ว

    sir pwede po ba nenyo i explain paano e convert yung 5hp 3phase into single phase,salamat

  • @arielcunanan4994
    @arielcunanan4994 2 ปีที่แล้ว +1

    Paano naman Sir i identify ang 9 leads kung ito ay unmarked

    • @joeycrisostomo5910
      @joeycrisostomo5910 3 หลายเดือนก่อน

      tester mo lht at lagyan mo ng tagging bro.tyagain mo

  • @yurialexacanada3859
    @yurialexacanada3859 ปีที่แล้ว

    may 8 leads na motor po ba? sana ma notice .

  • @laboktech6975
    @laboktech6975 2 ปีที่แล้ว +1

    panu po pag uvw marking sir?

    • @TagalogElectricaltips
      @TagalogElectricaltips  2 ปีที่แล้ว

      pakipamood po ying .ga ptevious videos meron po tyong paliwanag nyan

  • @elenofatmelon9836
    @elenofatmelon9836 3 ปีที่แล้ว +1

    good day sir? pahingi ng email add? thanks

  • @user-hf6dn2ir3q
    @user-hf6dn2ir3q ปีที่แล้ว

    Idol bakit iyong 3phese electric motor ko ang bilise mag init

  • @joselimasin3975
    @joselimasin3975 3 ปีที่แล้ว +1

    sir mag email po ako para s importanteng tanong ko ho. salamat

  • @vivinvidyawati4015
    @vivinvidyawati4015 ปีที่แล้ว

    Rpm berapa Mr

  • @jonathantalirongan3830
    @jonathantalirongan3830 3 ปีที่แล้ว +1

    Paano kung double delta sir?