Paano basahin 12 leads 3 phase motor terminal connections

แชร์
ฝัง
  • เผยแพร่เมื่อ 10 ก.ย. 2024
  • Matututunan dito kung paano basahin 12 leads 3 phase motor terminal connections

ความคิดเห็น • 63

  • @jonathanbrazil1325
    @jonathanbrazil1325 6 หลายเดือนก่อน +1

    Thank you po sa dagdag kaalaman sir napa husay nyo pong magpaliwag malinaw na malinaw detalyado pa god bless po

  • @IGTsamples
    @IGTsamples 2 ปีที่แล้ว +1

    Hay salamat tama pala ang configuration ko sa 3 phase blower motor

  • @wilfredobanes9489
    @wilfredobanes9489 6 หลายเดือนก่อน +1

    Wow nice sit thank u

  • @manuelmagno2432
    @manuelmagno2432 ปีที่แล้ว

    Maraming salamat sa information Sir for sharing your knowledge to us. Mabuhay po kayo!

  • @olimotovlog
    @olimotovlog ปีที่แล้ว

    Galing po sir detalyado po ang kaalaman dito sa vlog nyo

  • @benartdacman6699
    @benartdacman6699 10 หลายเดือนก่อน

    Maraming salamat po

  • @buedingmingoc1622
    @buedingmingoc1622 3 ปีที่แล้ว +1

    Salamat po sir .sa dagdag kaalaman na tolad sakin na bagopalang na electrician.sir pwedi gawa po kayu nang video nang motor calculation rewinding. Salamat po god bless you...

    • @TagalogElectricaltips
      @TagalogElectricaltips  2 ปีที่แล้ว

      cencya na at medyo nkalimutan ko na ang rewinding, d ko na kasi napractice e. yung huli kong gawa ng rewind ay nung nasa school pa ko. nagrewind ako dati ng motor ng floor polisher. split phase motor pa ang gamit dati sa floor polisher, ngayun d n ko familiar

  • @kulotunat7005
    @kulotunat7005 2 ปีที่แล้ว

    Dagdag kaalaman! Salamat po sir!

  • @julieanngudes6431
    @julieanngudes6431 3 ปีที่แล้ว +2

    Good job sir

  • @agukoytv7920
    @agukoytv7920 ปีที่แล้ว

    ang galing

  • @raymarkventura5604
    @raymarkventura5604 2 ปีที่แล้ว +1

    ty master very informative.

  • @simpliciocamirino2271
    @simpliciocamirino2271 3 ปีที่แล้ว

    Salamat sa sharing bosing.

  • @SimeonPalenzuela
    @SimeonPalenzuela 5 หลายเดือนก่อน

    Napakalinaw drawing ninyo. Pwede po ba malaman kung anong software ang ginagamit ninyo?

  • @michaelerestain4634
    @michaelerestain4634 2 ปีที่แล้ว

    So master kung hiningi ng motor 300 Volts s Wye at an supply nya eh 600Volts halimbawa supply s buildingor s Barko wye to wye lng or Delta to Delta pla gagawin ,kc nakakalito ,un name ng motor my nakalagay n 220,440Volts

  • @rod-yours695
    @rod-yours695 3 ปีที่แล้ว

    Pashare naman ako ng diagram ng topic na to bossing...salamat

  • @junpanganiban4576
    @junpanganiban4576 ปีที่แล้ว

    Thanks so much sir, pero pano po yun dati ay wye connection na 12 leads 440v ay ililipat po sa delta connection 440volts prin? Pano po ang babaguhin termination? Salamat po sa inyong kasagutan, baguhan plang po ako ... thanks 🙏🙏🙏

  • @DonnexPradel
    @DonnexPradel 2 ปีที่แล้ว

    Sir kong 760 ang Y at 420 ang dilta. Valtge
    KC ganyan ang valtage nya
    Ang Y Dilta namin 220 lang ang valtge posible ba na hindi cya aandar

  • @isaiahdakks6136
    @isaiahdakks6136 6 หลายเดือนก่อน

    sir tanong ko lang po my na encounter ako 12 leads na motor d ko na mabasa yung taging pano ko po mallalaman sa tester kung saan po ung t1 t2 t3 t4 t5 t6 t7 t8 t9 t10 t11 t12 salamat po

  • @abdullahalanflorendo2876
    @abdullahalanflorendo2876 2 ปีที่แล้ว +1

    Sir tnung lng po bkit mgkaiba ung sa nameplate ung connection wye to wye 380v 60hertz pero sa panel diagram is wye delta 6cables ppunta sa motor

  • @michaelerestain4634
    @michaelerestain4634 2 ปีที่แล้ว

    Ah Sir pwd b malaman f pano m malalaman f mali k or short un wiing , pr s wye Delta,or DeltaDelta, or wye wye,lalo n f 12 leads

  • @chennymaeestoche2811
    @chennymaeestoche2811 2 ปีที่แล้ว

    Sir magandang araw dapat bang sundin Ang nasa plate kasi naka lagay lng ay u1u2 v1v2 w1w2 peru 12 leads out po 220 delta Sana e kabit ko salamat Sana masagot sir.

  • @armansace36
    @armansace36 3 ปีที่แล้ว

    Sir sample tama nmn po yun connection ko motor to panel board controller pero nagtrip agad MCB kapag tinest possible po ba me shortage na winding ng motor ko..

  • @romerberganting1403
    @romerberganting1403 2 ปีที่แล้ว

    Sir sana masagutan kailangan po kc baguhan lng po kc ako source po namin sa planta is 220 lng so ibig sabihin delta delta gagamitin ko ang connection kuren ba sa contactor is delta delta rn or same dn wye delta salamat sana mapansin🙏🏿

  • @sydneysabellano8486
    @sydneysabellano8486 2 ปีที่แล้ว +1

    Sir pano po malalaman ang tagging ng mga terminals pag nabura na po ang mga ito,ok lang po ba magkabaliktad ang u1 mapunta sa u2 or u6 mapunta sa u5?

    • @TagalogElectricaltips
      @TagalogElectricaltips  2 ปีที่แล้ว +2

      hindi pwde magkapalit ng terminals. sa pagidentify nman pag burado na ang markings, kelangan mo ng tester at battery. gagawa ako ng bagong tutorial jan

  • @romeobarrios3214
    @romeobarrios3214 ปีที่แล้ว

    Sir. Pwede ba wye delta operation sa 220 volts ? 12 leads out motor. Pwede po ba Yun?
    Alam ko kasi 440 volts lang eh.

    • @romeobarrios3214
      @romeobarrios3214 ปีที่แล้ว

      Wye delta kasi control. Tapos 220 volts supply. Tnx po and godbless

    • @TagalogElectricaltips
      @TagalogElectricaltips  ปีที่แล้ว

      posible yan, depende yan sa voltage rating ng stator windings, dahil 12 leads out yan, ibig sabihin meron kang 6 na hiwahiwalay na stator windings. pwdeng iconnect ng delta in series o delta in parallel pag running at series wye o parallel wye pag starting. kung ang rating ng isang stator winding ay 220 volts, pwdeng gamitin sa 220 3 phase pag parallel connection ang windings at pwde ring gamitin ang 440 volts pag series connection ang windings

  • @ErnestoMosqueda-jy7wr
    @ErnestoMosqueda-jy7wr วันที่ผ่านมา

    Pano mag conecsion ng doodle speed

  • @edgardosarmiento6161
    @edgardosarmiento6161 3 ปีที่แล้ว +1

    Correction lng po sir,,,is it clockwise or counter clockwise? Tnx..

  • @jumelnonod6849
    @jumelnonod6849 3 ปีที่แล้ว

    sir may tanung lang ako normal lang ba n zero continuety ng wye delta n 12 leads out...ung line 1 at line 5 kc naga zero

    • @rap3208
      @rap3208 3 ปีที่แล้ว +1

      mga dulo ng windings yang 12 leads. Kung 12 leads ibig sabihin may 6 windings (2 windings per phase). Nai-brought out lahat yong dulo ng windings para may versatility na ibahin yong connection from wye to delta, o vice versa.
      Eto tandaan mo, pag yong motor ay 3 or 9-leads out, di mo pwedeng baguhin ang connection, malamang permanente nang naka-wye mga yan lalo na kung dual-voltage rated (para sa 9-leads).
      Kung 6 or 12 leads out, yan ay pwede mong gamitin as wye or delta. May versatility ka rin na dual voltage rated yang motor

  • @jesuscardinez1078
    @jesuscardinez1078 2 หลายเดือนก่อน

    What about Kung 380 volts ang supply?

  • @jeromesales8909
    @jeromesales8909 2 ปีที่แล้ว

    Sir wala po ba kayo yun v1 u1 at w1 ang samples?

  • @boyetmelgar
    @boyetmelgar 2 ปีที่แล้ว

    sir yung 9 leads po paano basahin..nawa po masagot nyo po..

  • @josephdepedro4959
    @josephdepedro4959 2 ปีที่แล้ว

    Sir panu po ung taging ay my u4v4w4 12 leads po 220v

  • @leonardotorres4721
    @leonardotorres4721 3 ปีที่แล้ว

    sir 9 tirminal itung motor na gagamitin ko pwedi i connec kuto sa delta connection paki sagut naman sir

  • @victorioracelis9483
    @victorioracelis9483 3 ปีที่แล้ว +1

    Paano Po ba ma I connect ung 3 phase sa single phase saan Po ikabit ung 2 wire lang

    • @TagalogElectricaltips
      @TagalogElectricaltips  3 ปีที่แล้ว

      alin mang 2 wire sa 3 phase system ay single phase, pwde kang magconnect basta dapat alam mo yung voltage n makukuha mo, sa delta secondary ng transformer makakakuha ka ng line to line na single phase, sa wye secondary nman ng transformer ay mkakakuha ka ng line to line at line to neutral

    • @victorioracelis9483
      @victorioracelis9483 3 ปีที่แล้ว

      @@TagalogElectricaltips ok Po thank you

  • @josephdepedro4959
    @josephdepedro4959 2 ปีที่แล้ว

    Yong taging kasi u1u2u3u4 v1v2v3v4 w1w2w3w4 pahungi Ng tulong sir low voltage 3phase

  • @arielcunanan4994
    @arielcunanan4994 2 ปีที่แล้ว

    Paano naman Sir kung unmarke yung 12 leads na wire paano hanapin polarity ng bawat isa. Halimbawa walang diagram paano hanapin ang grouping phasing at polarity

  • @mercapssarapac4661
    @mercapssarapac4661 3 ปีที่แล้ว +1

    paano po pag 380v ang supply ano po ang connection?

    • @TagalogElectricaltips
      @TagalogElectricaltips  3 ปีที่แล้ว

      pakilinaw po ng tanong

    • @mercapssarapac4661
      @mercapssarapac4661 3 ปีที่แล้ว +1

      @@TagalogElectricaltips i mean meron kami motor na tatlo ang boltahi 220/380/440...yung supply namin is 380v..ano po pde connection na gamitin nmin sa motor?.pde ko ba sya double Y or delta?.12 leads din po ang wire sa motor?...

    • @TagalogElectricaltips
      @TagalogElectricaltips  3 ปีที่แล้ว

      @@mercapssarapac4661 pakipicturan mo nga please yung name plate rating para masagot kita ng tama, salamat

  • @wilfredomaquilingjr.6430
    @wilfredomaquilingjr.6430 3 ปีที่แล้ว +1

    Sir paano gawing 6 leads ang 12 leads out..

    • @TagalogElectricaltips
      @TagalogElectricaltips  3 ปีที่แล้ว

      pwde yan bale icoconnect lng yung mga pang middle terminals T4&T7, T8&T5, T6&T9

  • @MichaelMontemor-kf1pb
    @MichaelMontemor-kf1pb ปีที่แล้ว

    Pwedi pong sa actual idol

  • @josephchua8850
    @josephchua8850 2 ปีที่แล้ว +1

    GOD DAY SIR, KUNG NABURA PO YUNG LABEL O HINDI NA MAKITA YUNG LABEL SA 12 LEADS MOTOR, PAANO KK PO MALALAMAN O MALALAGYAN NG TAMANG LABEL? PAANO PO MAG TEST O MALAMAN? THANKS INADVANCE!

    • @TagalogElectricaltips
      @TagalogElectricaltips  2 ปีที่แล้ว +1

      may paraan jan, gagamit tyo ng tester at DC power supply or battery. gawa siguro ako ng video tutorial jan

    • @josephchua8850
      @josephchua8850 2 ปีที่แล้ว +1

      Maraming salamat Sir in advance! Antay ko po video niyo, thanks and more power!

    • @JOSHDTV-hf5hr
      @JOSHDTV-hf5hr ปีที่แล้ว

      Sir video napo kau ng 12leads motor na nabura napo ung label?

  • @khristianbajo9472
    @khristianbajo9472 3 ปีที่แล้ว

    Sir pde mo makahingi ng soft copy nian?

  • @kimolaso9943
    @kimolaso9943 3 ปีที่แล้ว

    Pano gamitin ang demand factor master

    • @TagalogElectricaltips
      @TagalogElectricaltips  3 ปีที่แล้ว

      mag gawa ako ng video tungkol sa demand factor

    • @kimolaso9943
      @kimolaso9943 3 ปีที่แล้ว

      @@TagalogElectricaltips Maraming salamat master