    @1943L 4 หลายเดือนก่อน

    The blue barrel will vent air I assume. That should be good for the water arriving at the turbine I think.

  • @kletusbobby7029
    @kletusbobby7029 3 ปีที่แล้ว +2

    I really like your duel voltage setup.

  • @JoeMalovich
    @JoeMalovich 2 ปีที่แล้ว +2

    Relocate the barrel up to the screen like I have done. It shouldn't have any pressure on it.

  • @clee79
    @clee79 ปีที่แล้ว

    A silt filter barrel should never be located in the drop section of a drive pipe, resulting in loss of head pressure. In best practice the free water level of the silt filter barrel is the start height of the drop section of your drive pipe. Relocating the silt filter barrel up the hill next to the collection will increase the head pressure and so also your power output at the generator.

  • @jamess1787
    @jamess1787 3 ปีที่แล้ว +4

    Algorithm brought me here. I watch some microhydro videos like Joe malovich, Kris harbour, Pierre et Malouin, loftis of six, etc.
    Thanks.

    • @JoeMalovich
      @JoeMalovich 2 ปีที่แล้ว

      Yes. I try to make my videos helpful and entertaining but it's hard to achieve both.

  • @vannboyce3250
    @vannboyce3250 2 ปีที่แล้ว

    You should be able to increase the pressure by removing the 90 deg elbow at the turbine. Awesome setup and build!

  • @kletusbobby7029
    @kletusbobby7029 3 ปีที่แล้ว +4

    No do not close off the vent line. The line NEEDS to be open to allow air through. But if the vent (head) pipe is vertical up to the height just above the water level of the supply/filter box, all the will go up and out, but you will retain ALL of the head from the water level at the supply/filter box.

    • @daviddavids2884
      @daviddavids2884 2 ปีที่แล้ว

      it appears that you did Not understand what the issue was. it was, too much Water.!!!!!

    • @kletusbobby7029
      @kletusbobby7029 2 ปีที่แล้ว

      @@daviddavids2884 It appears you did not understand my comment. The vent in the blue drum is not a vent if it is closed. The purpose of this vent is to let air out of the system before it enters the penstock. The vent outlet needs to be at the highest possible height, just above the pick up screen in elevation, in order to maximize the available head. The blue drum needs to be strong enough to take the head it has, he said it is 10-12 foot of drop that is 5.2 psi. (It does look like it is strong enough) If the drum can not cope with this head, then it should be replaced with a stronger container, or moved up stream a little, to reduce the pressure on it. (As I advised him on his previous video.)
      His problem has nothing to do with how much water there is, it has to do with the placement of the air relief tank and the material it is made of.
      By the way, how is your hydro set-up going?

  • @1981dasimpson
    @1981dasimpson 3 ปีที่แล้ว +2

    You have a few options I see enlarge the jet add more jets or even a 2nd turbine

  • @Richard_Trap
    @Richard_Trap 3 ปีที่แล้ว +2

    4:35 If the blue vessel is at 20 degrees (tilted) and the tube reaches the bottom, the sediment is automatically drained

  • @MrPizzaman09
    @MrPizzaman09 4 หลายเดือนก่อน

    Taller stand pipe should fix it.

  • @kletusbobby7029
    @kletusbobby7029 3 ปีที่แล้ว +1

    Yes I would definitely replace the blue drum. It needs to take the full head from the supply/filter box. In theory only air should travel up and out of the top of the (head) pipe, but is reality water surges up and down the (head) pipe. The hose out the top of the drum needs to be able to cope with all of the flow to the blue drum. So when you close the turbine off all the water can flow up to the top of the (head) pipe, and not pressurize the blue drum. The top of the (head) pipe should be a height just above the water level at the supply/filter box. This will allow all the air to escape up and out of the line.
    That will give you maximum potential down at the turbine. I have been working with my system and found setting it up as I have described is best.

    • @matthewagee4214
      @matthewagee4214  3 ปีที่แล้ว

      Thank you. I agree, I will probably move the barrel closer to the box in the future.

  • @1981dasimpson
    @1981dasimpson 3 ปีที่แล้ว +1

    You can leave both controllers on as the 12v system will charge first when upto voltage the controller will release the pull down on turbine and the 24v system will charge that or have a mppt between the 24v and the 12v or even a 2nd turbine one 24v the other 12v

  • @bertiesmit965
    @bertiesmit965 2 ปีที่แล้ว

    I have seen that they just install a stand off pipe that T's into the main line

  • @anthonymellor174
    @anthonymellor174 2 ปีที่แล้ว

    I B C tank instead of barrel have raised up higher fed with a ramp pump double your downward pressure

  • @roosenlodewijkwiggers4594
    @roosenlodewijkwiggers4594 6 หลายเดือนก่อน

    Don’t understand why you have put in that blue drum… has no fuction, only pressure loss. Better to have sediment venting just before turbine

  • @scwharley89
    @scwharley89 2 ปีที่แล้ว

    What brand charge controller....thx steve

  • @ngancekale3300
    @ngancekale3300 2 ปีที่แล้ว +1

    hi from Papua New Guinea. Just want to ask if you can tell us What's is the head? What is the flow rate? The pressure at the hydro? How many appliances you can power using this setup and for how long?

    • @matthewagee4214
      @matthewagee4214  2 ปีที่แล้ว

      150 feet of head, 68 psi with the turbine running, and it produces 10 amps on 12 volt/ 5 amps on 24 volt.

  • @jdeadman
    @jdeadman 2 ปีที่แล้ว

    5amp @ 24V is the same Wattage as 10A @ 12V just FYI

  • @bobjoatmon1993
    @bobjoatmon1993 3 ปีที่แล้ว

    The goal IS as much water pressure as gravity can produce, by venting the blue drum you are losing efficiency / power. Obviously you need to re-engineer and improve that lid and even the barrel perhaps.

    • @daviddavids2884
      @daviddavids2884 2 ปีที่แล้ว

      you are losing efficiency / power you obviously were NOT paying attention.!!!

    • @bobjoatmon1993
      @bobjoatmon1993 2 ปีที่แล้ว

      @@daviddavids2884 your statement's meaning isn't clear. I have no ideas what you mean.

  • @natrajannatrajan6457
    @natrajannatrajan6457 2 ปีที่แล้ว

    தேவை.உள்ளவர்களுக்கு.மின்சாரம்வழங்கும்போது........

  • @natrajannatrajan6457
    @natrajannatrajan6457 2 ปีที่แล้ว