Setting An IP Address On a Powerflex 525 Drive Using BootP Server | Best Practice Method Windows 10

แชร์
ฝัง
  • เผยแพร่เมื่อ 16 ต.ค. 2024
  • This video shows using a BootP server to set up your IP address for a Powerflex 525 drive in just a few minutes. Also showing the watch-outs to be aware of to help you get the best rate of success in using BootP server.
    I made this video because during making my new Powerflex 525 training course.
    I had to default & setup the drive several times so I thought that videos would be a great point of reference as an aid for everyone to learn from.
    Setting up the IP address using BootP server on any device should be a direct connection & not done through a switch to make sure that you have a direct path with no confusion.
    If you like o see more sample videos about a Powerflex 525 then visit:
    www.allen-brad...
    #Powerflex525 #BootPServer #Powerflex

ความคิดเห็น • 18

  • @ShaneWelcher
    @ShaneWelcher  3 ปีที่แล้ว +1

    Subscribe: mmini.me/Subscribe-4-Updates
    Visit Our Training Center:
    www.allen-bradley-plc-training.com/

  • @ThriftyToolShed
    @ThriftyToolShed ปีที่แล้ว +1

    Great information. Thanks for sharing Shane!

  • @ardentdfender4116
    @ardentdfender4116 3 ปีที่แล้ว

    I've seen this done one time before on a commissioning project when we had to assign IP Addresses to a whole lot of New Nodes on Flex Logic equipment in revamped panels doing the BootP. So I've always remembered that as well Yes, we had to cycle power to retain the IP Address after the first assignment, but fine after. I wasn't aware of the CCW part though, so that's new to me in awareness. Great!

  • @soviethammer645
    @soviethammer645 ปีที่แล้ว +2

    When I follow the steps to set up a 1203-usb connection, rslinx doesn't see the cable. I checked device manager and ensured the the com ports were the same, I set the settings like you showed. Does it have to be in automatic in the startup options?

    • @ShaneWelcher
      @ShaneWelcher  ปีที่แล้ว +1

      You need RSLinx pro and the USB driver will automatically pop up.
      If not then verify you have a connection through device manager & if you are using a VMware then make sure it is connected to the VM instead of the host

  • @soviethammer645
    @soviethammer645 ปีที่แล้ว +1

    Is it the same procedure for power flex 400 drives?

    • @ShaneWelcher
      @ShaneWelcher  ปีที่แล้ว +1

      Yes, you can use BootP server for most all Rockwell Automation devices.
      There is a new FT manger tool coming in the future

  • @Brijesh8080
    @Brijesh8080 2 ปีที่แล้ว +1

    Hi, Shane
    Please help me , How to convert the .PF5 files into Word or excel.
    I want to record the The parameters of PF525.

    • @ShaneWelcher
      @ShaneWelcher  2 ปีที่แล้ว

      There is no easy way from my knowledge, sorry bud.
      Here is a document that might help.
      www.mediafire.com/file/qs4ac9t8ijyaqmg/Mains+free+and+pf5+importexport.docx/file

    • @Brijesh8080
      @Brijesh8080 2 ปีที่แล้ว +1

      @@ShaneWelcher Thanks Shane. It will also be useful to me. But I need CCW Software. From where I will get it.

    • @ShaneWelcher
      @ShaneWelcher  2 ปีที่แล้ว

      @@Brijesh8080 also keep is mind you could save as a PDF

    • @Brijesh8080
      @Brijesh8080 2 ปีที่แล้ว

      @@ShaneWelcher Dear Shane, My Question is From where I can get CCW Software? Is it available online? Because without CCW Software I will not be able to access the parameter list and .PF5 is directly not convertible to PDF or word.
      Thanks

    • @ShaneWelcher
      @ShaneWelcher  2 ปีที่แล้ว

      @@Brijesh8080 Create an account on Ab.com then go to the compatibility download section & search for CCW or Connected components.
      You can download it there.
      I believe I might have a copy of version 12 on my website.
      OnlinePLCsupport.com
      And I know I provide the software on my course for Powerflex drive.
      At www.allen-bradley-plc-training.com