Sterlitech Automated Skid System: How to Start, Operate, and Shutdown

แชร์
ฝัง
  • เผยแพร่เมื่อ 25 มิ.ย. 2024
  • Watch this short video on how to start up, operate, and shutdown the Sterlitech Automated Skid System.
    0:12 Prepare the skid
    0:32 Automated Skid Startup
    1:23 Turn On Digital Panel
    1:40 Set up Program Preferences
    2:45 Start Experiment
    3:17 Finish Experiment
    4:03 Automated Skid Shutdown
    Sterlitech Automated Hybrid Skid Mounted Membrane Filtration System
    Specifications:
    Scale / Membrane Area: Medium
    Cell / Housing Type: Sepa, 1812 Housing
    Process Configuration: CFF/TFF
    Lines: 2
    Membrane Types: MF, UF, NF, RO
    Power: 110V or 230V
    Temperature regulation: Yes
    Data logging: Yes
    Touchscreen interface: Yes
    ====
    We recommend reviewing the setup video to ensure the system has been set up properly before operation.
    Make sure the drain valve is closed. Remove the lid from the tank. Go ahead and pour in the process fluid.
    These carboys that we have available from Stirlytech are great for getting in this tight space.
    Replace the lid.
    For the startup. Begin by making sure the regulating valve is fully loose and turn to the left.
    Next, we're going to close the outlet valve by turning it clockwise and close the vent valve by turning this fully clockwise.
    Next, we can open the main valve by turning this counterclockwise and begin to see the tank pressure increase to 22,200 psi on the gauge on the right.
    Now we can open the outlet valve by turning this counterclockwise and begin increasing the feed pressure by turning the regulating valve clockwise. We're going to increase the feed pressure until this gauge reaches at or above the desired experiment pressure.
    Today I'll be setting this to 500 psi.
    Begin by turning on the digital panel. The light will turn green. Next, we'll open and unlock the digital tablet. Once the panel has warmed up, we need to ensure we're connected to Wi Fi and then open the interface app.
    Now to operate the skid, I am connected with Wi Fi using my tablet. You can also connect with Wi Fi or Ethernet cable using a PC.
    On the tablet, I will be opening this kiosk browser application right here, which is pre configured to pull you into the IP address of the skid.
    Once loaded, select remote view and then select your unit of choice. First thing we want to do is select the additional information page on the bottom menu and adjust their pressure limit as we see necessary. I'm using a CFO42 cell with 1000 psi limit, so I will leave this set to 1000. This page also has helpful information on system specifications, how to connect to the HMI with an Ethernet cable, and scaling information. Return to the general operations page by selecting it on the bottom menu.
    Next, make sure your line selector is set to the correct line. My cell is connected on line two so we can select the right side of the switch to move this over to line number two. Next, select your flow rate set point to set your desired flow rate, do the same thing for the pressure set point.
    To start your experiment, simply press start. You'll see the flow rate and the pressure values begin to ramp up. You can view a trend line of any of this data by selecting on the gages.
    You can do the same for any of the connectivity, temperature or scale values on the bottom.
    When you are finished with the experiment, press stop to turn off the pump and motor and then reset the timer by selecting the timer.
    There are two programs built in. The first is a set point program where you can set three distinct set points and the skid will walk through each of those set points. The second is a ramp program where you can set a peak flow and pressure.
    The skid will ramp up to those peak flow and peak pressure over a duration of time, hold it for a given amount of time, and then ramp down to a final flow and a final pressure set point.
    If at any point you see an alarm populate here and the light on the front of your digital panel turns red, you can view and resolve those alarms in the alarm page here on the bottom.
    Now for shutdown, we're going to begin by closing the main valve on the tank, turning this clockwise. Next, open the vent relief valve by turning this valve counterclockwise. Once both pressure gauges read zero psi, turn the main regulating valve counterclockwise until that is fully open, and then close your outlet valve by turning this clockwise.
    Next, drain the system by opening the drain valve. The system can be fully drained with the recovery kit.
    Finally, turn off the main power supply.
    ===
    Interested in Sterlitech Skid Mount Membrane Filtration Systems? Find unit for your application here: tinyurl.com/2p8n725u
    For more information, contact us here: tinyurl.com/3ptva24n or call us at 1-877-544-4420