  • Found an interesting one with this reach-in-cooler having weak suction valves in compressor, causing the pressure to slowly drop lower and lower. I appreciate everyone watching. Please consider liking video and subscribing.

ความคิดเห็น • 26

  • @HermesVintage
    @HermesVintage 3 ปีที่แล้ว +4

    When your leak detector is worth more than the prep table 😂

  • @rosskious7084
    @rosskious7084 3 ปีที่แล้ว +4

    When you upgrade to that style of drier, you need to add a little extra refrigerant. Sporlan has a chart for the amount the drier holds.

    • @HVACRSTRONJAY
      @HVACRSTRONJAY  3 ปีที่แล้ว +1

      Yeah thats definitely good info to know. appreciate the feedback

    • @rosskious7084
      @rosskious7084 3 ปีที่แล้ว

      @@HVACRSTRONJAY Btw good video.

  • @jackrabbitalex
    @jackrabbitalex 2 ปีที่แล้ว +2

    Running kinda hot with the torch turn it down so you don't cook the joint.

    • @HVACRSTRONJAY
      @HVACRSTRONJAY  2 ปีที่แล้ว

      I like my copper well done 😁

    • @randomrefrigeration4564
      @randomrefrigeration4564 ปีที่แล้ว

      I had to fast forward could not watch it
      He had it glowing cherry red with no nitro flowing
      Cap tube was like dang man you killing me
      Rookies whata do they think they know it all after a year of changing parts lol

  • @UltraHydrophobiccoat
    @UltraHydrophobiccoat 3 ปีที่แล้ว +2

    When you see the frost on suction line at back the system is over charged. I think the old compressor has no problem.
    When You opened the system if there’s no any or little gas in the system somewhere is leaking. Normally inside of the box at evaporator side. You will get callback after a couple of months for sure.

    • @HVACRSTRONJAY
      @HVACRSTRONJAY  3 ปีที่แล้ว +1

      This was recorded in early 2020, so far they have had no issues but I see your point and appreciate the advice. 👍

    • @randomrefrigeration4564
      @randomrefrigeration4564 ปีที่แล้ว

      I’m sorry but your leak check was not sufficient
      30 years doing this you missed a leak
      200 PSI would have found your leak trace gas with 404a as well
      134a is hard to hit on 404 isn’t
      I also think there was nothing wrong the compressor pulling over 4 amps and called it weak or bad valves doesn’t make sense
      Don’t always trust tech support haven’t called them in years
      You are young and cocky some day you will figure it all the mistakes over the years

  • @johnbaxley8948
    @johnbaxley8948 ปีที่แล้ว +1

    How much would a repair like this cost ? Parts and labor combine

  • @dangda-ww7de
    @dangda-ww7de 3 ปีที่แล้ว +3

    I didnt see any nitro, did you use any when u braze?

  • @shine-cg9uf
    @shine-cg9uf ปีที่แล้ว

    Why didnt new compressor require a capacitor ? What was the big notch indent on top of compressor for?

  • @randomrefrigeration4564
    @randomrefrigeration4564 ปีที่แล้ว

    Nextech

  • @cpabrego
    @cpabrego 3 ปีที่แล้ว

    Can you help me with my gdm-26? Fridge is 80 degrees, it was working well a couple of days ago. Fans and compressor all appear to be working.

    • @HVACRSTRONJAY
      @HVACRSTRONJAY  3 ปีที่แล้ว

      Email me at hvacrnovice@gmail.com

    • @cpabrego
      @cpabrego 3 ปีที่แล้ว

      @@HVACRSTRONJAY sent thanks

  • @emmaa427
    @emmaa427 3 ปีที่แล้ว +1

    I wonder how much you charge for all these work!!??

    • @HVACRSTRONJAY
      @HVACRSTRONJAY  3 ปีที่แล้ว +2

      usually just an arm and a leg

    • @emmaa427
      @emmaa427 3 ปีที่แล้ว +1

      @@HVACRSTRONJAY can you give me ballpark figure...thx

    • @HVACRSTRONJAY
      @HVACRSTRONJAY  3 ปีที่แล้ว

      Email me at hvacrnovice@gmail.com

  • @randomrazr
    @randomrazr 2 ปีที่แล้ว

    are True coolers reliable?

    • @HVACRSTRONJAY
      @HVACRSTRONJAY  2 ปีที่แล้ว

      I see alot of true coolers have issues but on the flip side they are usually easy to fix or not that expensive. But like all units its how much of a beating they get and if they get them tuned up regularly.

    • @randomrazr
      @randomrazr 2 ปีที่แล้ว

      @@HVACRSTRONJAY like cleanign the dust off the coils or more tune up necessary?

    • @HVACRSTRONJAY
      @HVACRSTRONJAY  2 ปีที่แล้ว

      100% If you take care of that true cooler it will take care of you.