John Jennings
เข้าร่วมเมื่อ 7 ม.ค. 2021
I am just an HVAC tech, who likes flounder gigging, trying to teach a few others along the way. I hope to keep beginning HVAC technicians engaged in the field and give them something to look at and help them as they learn how to diagnose and repair systems. There are a lot of fundamentals to learn and master. Being part of this online HVAC community can definitely help you in the field.
As far as the flounder gigging...it's the best thing ever. You don't have to buy bait and you get to pick which one you want for supper! Need I say more?
As far as the flounder gigging...it's the best thing ever. You don't have to buy bait and you get to pick which one you want for supper! Need I say more?
Learning to Read A Wiring Diagram Part 2
This is the 2nd of videos that I am putting out to try and help people understand how to read a wiring diagram and use it in electrical troubleshooting. I am moving from the electric heat kit I started with in the first video and into the air handler that I have in the shop. I continue with the couple of key "rules" that I have learned over the years and attempt to help get this across to whomever watches this video.
Remember that what I go over here and how we look at things will have to apply to anything we connect to this component. Even though you may have a residential, or commercial system, that has some add-on electrical parts not associated with the original air handler or outdoor unit...that doesn't matter...all of it has to fit together to be one functioning system.
00:00 Intro
01:20 Rule 2
01:50 Look at the air handler
03:48 Air Handler Wiring Diagram
04:53 Primary Side of the Transformer
06:52 Rule 3
08:00 The PSC Blower
10:05 Low Voltage Circuits
11:00 24v Red Wire/Fuse/Thermostat Circuit
12:35 Blue or 24v Common Circuit
13:27 Green or "G" Circuit
13:41 White or "W" Circuit
14:43 Brown or "W2" Circuit
15:30 High Voltage Purple Wire
16:27 Outro
Remember that what I go over here and how we look at things will have to apply to anything we connect to this component. Even though you may have a residential, or commercial system, that has some add-on electrical parts not associated with the original air handler or outdoor unit...that doesn't matter...all of it has to fit together to be one functioning system.
00:00 Intro
01:20 Rule 2
01:50 Look at the air handler
03:48 Air Handler Wiring Diagram
04:53 Primary Side of the Transformer
06:52 Rule 3
08:00 The PSC Blower
10:05 Low Voltage Circuits
11:00 24v Red Wire/Fuse/Thermostat Circuit
12:35 Blue or 24v Common Circuit
13:27 Green or "G" Circuit
13:41 White or "W" Circuit
14:43 Brown or "W2" Circuit
15:30 High Voltage Purple Wire
16:27 Outro
มุมมอง: 1 072
วีดีโอ
Learning to Read A Wiring Diagram
มุมมอง 3.2K5 หลายเดือนก่อน
This is the first in a series of videos in which I'll try to get the point across on how I read a diagram and use it in electrical troubleshooting. I chose to start out with a high voltage application because this particular electric heat kit will lend itself fairly easy to understanding. It will also allow me to go into a couple of key "rules" that I have in my head. Remember that what I go ov...
Refrigerant Pressure Switches (Part 2) - A look at a 2 Stage Scroll Compressor
มุมมอง 1.4K9 หลายเดือนก่อน
So part 2...this video is a few minutes on a 2 stage scroll gas pack with a different setup concerning the refrigerant pressure switches. This unit has been used before in some videos that I have done but I never noticed the 2 high pressure switches in the discharge line. Never have I seen anything like it but the way it works with the 2 stage scroll I think I can understand and appreciate.
Refrigerant Pressure Switches (Part 1)
มุมมอง 6K10 หลายเดือนก่อน
This video is a few minutes on hvac refrigerant pressure switches. You can find them in straight ac units or heat pumps but they are not used in all of them! I go through identifying issues when you have the unit cycling and you are able to easily see with you manifold gauges what is happening in the system. I also get into the 2 methods I would use to check the pressure switches if you happen ...
Update! X13 to PSC Motor Changeout Using the ICM715
มุมมอง 1.4K10 หลายเดือนก่อน
This is an update to the video that I posted on replacing an X13 motor. The invention of this product definitely makes it easier to convert to a PSC motor. I don't know what else to say except to look them up and learn about their products. Try the Mainstream Engineering website and look for QwikSwap X1, X3, or V3. Depending on if you want to have a single speed output or if you are using a var...
Crankcase Heaters and Single Pole Contactor
มุมมอง 3.1Kปีที่แล้ว
So...I was talking to some people around the shop and we were discussing contactors, replacing them, etc. Nothing to bad. Then someone on the Tube of You commented about "back-feeding" circuits and that brought up crankcase heaters. This is just a few minutes on crankcase heaters, why they use single pole contactors (mostly), and how they are actually pulling it off. It isn't perfect but someth...
Package Unit Refrigerant Checks (Getting Started)
มุมมอง 4.1Kปีที่แล้ว
This is a video to follow up on the previous one where I tried to show how to start evaluating the refrigerant numbers and/or system performance. There are many ways to do this and this one is just mine. I have tagged in a couple of cards (to refer you to those older videos in case you wonder just where I am coming from). Of course, I know that long-windedness of my videos so the chapters shoul...
Current Switch and How You Can Use It
มุมมอง 11Kปีที่แล้ว
This video is about a current switch. It is a fairly simple switch and of course this is just one variant of the many out there. The current switch I am using came from none other than Amazon and is no doubt a cheaper version of some of the more famous commercial hvac controls brand names. The idea is to get you to understand and remember the basics! I am running through a couple different scen...
Ice Cube Relay and LED's in an Air Handler!
มุมมอง 6Kปีที่แล้ว
This is a small feeble attempt to look at an ice cube relay or what they call a plug in relay. I am really more interested in the circuits, sequence of operations, and thought processes for operation and troubleshooting. I'll probably always have the idea in my head that a relay is just a relay, no matter the model number, amps it can handle, or all the switches it may or may not have on it. It...
RIB Relay in Residential Air Handler?? Absolutely Can!
มุมมอง 17K2 ปีที่แล้ว
For this video (and possibly a couple more) I am going to take a look into some commercial style controls. They are going to fall into the traditional on/off controls so they aren't anything fancy. They look different and that is what seems to throw people off about them. It all boils down to paying attention and using learned basic theory to install or troubleshoot. This walk-through of instal...
Goodman 80% Furnace Circuit Board (with X13 Blower Motor)
มุมมอง 13K2 ปีที่แล้ว
This video is about a circuit board that is found in many Goodman furnaces. The first half is a rough explanation of the layout of the board...just in case you never paid attention to it. The second half is a brief walk-through of some voltage checks that you could be doing in the field. Of course it isn't everything but I think you will get the idea. Hopefully you get the idea before you go to...
Motor Windings vs. Terminals
มุมมอง 1.7K2 ปีที่แล้ว
I have been asked/talking about different motors, the amount of windings they have inside, terminals, etc. I thought it might be beneficial to put together a short video with a few examples. There are many different types of motors out there but you should try to understand the basics of them when you come across one in the field. I started off first with the standard PSC motor, then show a 3 p...
Part 2 - How to Get Started Checking Refrigerant Charge
มุมมอง 3.2K2 ปีที่แล้ว
So once again...While I will tell you that I am not a perfect a/c tech, I do stick to some basics that I feel people are forgetting or just never learned. This video is about how I think about superheat and subcooling as I am evaluating or diagnosing an a/c system. It is not a perfect way and I do mention that I like to use a range of numbers when getting an idea of what a system is doing, but ...
How I Get Started Checking Refrigerant Charge
มุมมอง 5K2 ปีที่แล้ว
While I will tell you that I am not a perfect a/c tech, I do stick to some basics that I feel people are forgetting or just never learned. This video is about refrigerant saturation temperatures and how to get started when evaluating or diagnosing an a/c system. It is not a perfect way and I do mention that I like to use a range of numbers when getting an idea of what a system is doing, but it ...
Is the relay REALLY bad? | Understanding HVAC Electrical Concepts
มุมมอง 80K2 ปีที่แล้ว
Is the relay REALLY bad? | Understanding HVAC Electrical Concepts
Is the thermostat really bad? | Understanding HVAC Electrical Concepts
มุมมอง 19K2 ปีที่แล้ว
Is the thermostat really bad? | Understanding HVAC Electrical Concepts
Summer Cooling Maintenance | Getting Ready for the Summer Season - Keeping Your Unit Running Right!
มุมมอง 2K2 ปีที่แล้ว
Summer Cooling Maintenance | Getting Ready for the Summer Season - Keeping Your Unit Running Right!
80% Goodman Furnace - Heat Not Turning Off | Shop Troubleshooting (Bad thermostat wire)
มุมมอง 34K2 ปีที่แล้ว
80% Goodman Furnace - Heat Not Turning Off | Shop Troubleshooting (Bad thermostat wire)
80% Goodman Furnace - Furnace Won't Light | Shop Troubleshooting (Gas Valve outlet pressure too low)
มุมมอง 139K2 ปีที่แล้ว
80% Goodman Furnace - Furnace Won't Light | Shop Troubleshooting (Gas Valve outlet pressure too low)
Why I Don't Like Using Ground to Check 208/240 Circuits
มุมมอง 10K2 ปีที่แล้ว
Why I Don't Like Using Ground to Check 208/240 Circuits
Horrible Looking | Re-Wiring a Heat Pump Air Handler with Electric Heat
มุมมอง 18K3 ปีที่แล้ว
Horrible Looking | Re-Wiring a Heat Pump Air Handler with Electric Heat
Replacing an X13 Blower Motor with a PSC Motor
มุมมอง 22K3 ปีที่แล้ว
Replacing an X13 Blower Motor with a PSC Motor
How to Identify and Wire a 2 Heat 1 Cool Air Source Heat Pump Unit
มุมมอง 7K3 ปีที่แล้ว
How to Identify and Wire a 2 Heat 1 Cool Air Source Heat Pump Unit
Low Voltage Troubleshooting a Goodman Electric Heat only Unit
มุมมอง 20K3 ปีที่แล้ว
Low Voltage Troubleshooting a Goodman Electric Heat only Unit
How to Identify and Wire a Heat Cool Unit - 1 Heat 2 Cool Package Unit
มุมมอง 2.8K3 ปีที่แล้ว
How to Identify and Wire a Heat Cool Unit - 1 Heat 2 Cool Package Unit
How to Identify and Wire a Heat Cool System - 1 Heat 1 Cool Furnace with A/C
มุมมอง 6K3 ปีที่แล้ว
How to Identify and Wire a Heat Cool System - 1 Heat 1 Cool Furnace with A/C
How to Identify and Wire a Heat Only Unit - Electric Furnace
มุมมอง 54K3 ปีที่แล้ว
How to Identify and Wire a Heat Only Unit - Electric Furnace
I'm still confused i don't have none of he's readers machines
Is there a way to bypass the defrost sensor on the newer style board? I live in AZ and have no need for that sensor and I believe it's causing my unit to short cycle. Runs for 5 and shuts down for 2mins. The 3 little capacitors get super hot.
Good job thank you for your help
Please help me with the Wires 24 volts for the Carriers.
What you got going on?
Thank you 😎 🤟
Thanks for sharing this, saved me a service call!
Thanks for the video. I tested the voltage on my HK32EA001. The voltage reading between C and R is 5.5v. In the video you said it should be 24v. Can you advise.
You need to find a full 24v! You need to backtrack and find power...if you got 5.5 at the wire nuts outside the you need to check R and C and the air handler connections. If you have it on the air handler end of the wire but not on the heat pump end...may be a wire connection (loose wire nuts, corrosion, etc) or a break in the wire!
@@johnjennings-JJ thank you for the reply. I appreciate the information.
BTW...where are you located ???
Not too much detail but I am in the Carolinas...had a guy spot me in a Tractor Supply the other day though and had a video pulled up on his phone 🤣 He asked "is this you?" Got me! Just a dude at a Tractor Supply like you.
Great Tutorial !!! ......keeping this as file for either my own work or to show tech if needed....
Thanks. Means a lot.
@@johnjennings-JJ ...good, slow, clear speech and good close-ups of the areas in question.....great job....👍...you're welcome.
Thank you for the video. I have a scenario where my coil turns on only when I disconnect the blower motor wire(purple). If I connect the blower wire, the blower fan turns on but the heating element doesn't. It's puzzling me.
Sounds like you got something wired wrong. Have you replaced something lately?
@@johnjennings-JJ The defrost control board was burnt. I replaced that. I labelled each wire before removing the board and replacing it. I guess the outdoor unit defrost control board can be ruled out because the heating happens at the air handler. Secondly, the fuse on the relay board in the inside unit was burnt, I replaced it.
Sorry for the late reply, got caught up at work. The only time I have seen that happen on an electric heat kit and blower motor circuit board was when the fan board was mis-wired on the relay. That was a goodman air handler and all the high voltage wires were basically one terminal off of where they were supposed to be. That being said it might just be a faulty relay on that fan circuit board. Sometimes when things go boom it messes up something else before that fuse catches it! I would be curious to find out what fixes this.
@ Thanks for explanation and please do be sorry :). I have the new fan relay board. I will keep you posted how the repair goes.
Could u do video with Ruud defrost board?
Ruud unit: what is the OCT & OAT terminals, and what are they used for? Also, what is the D terminal. Does it feed as W to light heat strips?
That one must be a Demand Defrost board. There are 2 temp sensors (thermistors) tied to the board. OCT is Outdoor Coil Temp, OAT is Outdoor Air Temp. I believe it is a purple wire factory connected to the D terminal and yes it goes to the white wire we typically use to turn on the heat strips in Defrost!
@johnjennings-JJ Thank you!
@johnjennings-JJ Thank you for helpful insight.
Great video
How do you remove these? Why start with it outside of the furnace already
Sometimes you can just take a few screws from off of the plate above the burners. Different models vary of course. This was an old COVID video when it all started and they kicked me out of the training room at work. It was the only thing I had when the world shut down. You got a particular model number...might help if you haven't already figured it out.
Will this work the same on a rtu I’m still learning this my first year and I work commercial
Same principle but on commercial you will run into different power supply voltages like 460/277V but once you see and understand it you can use it on whatever!
@@johnjennings-JJ thank you,thank you love your videos.
You saved me. Some maintenance man had removed everything, and wired in 120v relays with wires going everywhere. If that wasn't enough, no wiring diagram. So I really appreciate this for helping me get this setup going in an old unit. Bless you for these videos.
great video. thanks brother.
I am trying to do this to my hvac that went out - but i live in florida so heat is NOT necessary.. just want the fan to turn on.. but the board has an L1 and L2.. so how would this be hooked up? I understand the 24V part.. but if i get L1 from the transformer and put on #3 - and fan (Med) on #1… how am i giving the fan 240V? What is the purple on the fan for? Should the purple but hooked to L2?
Connection-wise...i believe the purple from the fan goes back to the capacitor where it joins another purple wire the goes back to the L2 side (black wire) of the transformer. You shouldn't have to mess with that L2 side of power for this as the relay will only be installed in the L1 side like you already mentioned.
@ ah, I think maybe that answers my question. The purple wire (common) of my fan connects to the pcb.. I am assuming this is a 120v supply (L2)? Since I’m getting rid of the board all together and you said purple most likely joins L2 anyways, I should hook this purple to L2 right? This way I’m getting the 240v - purple common + relay . Am I correct or am I way off?
Yes. You can go back to the terminal block or the primary side of the transformer had a black wire with a place to add the purple to it. Sounds like you got it though.
thank you for doing this
You failed to show procedure to connect hose to gas valves.
I have been working on stuff for a long time and I still like to watch videos I'm always learning something because you can not learn to much no matter how simple it looks thangs change all the time on different heating and cooling units.
Got to keep learning. I think that keeps us alive!
Thank you for your help, I’ve figure out my board is bad. Now is it possible to directly replace my old Upgrade for Goodman PCBDM130 Rev B Heat Pump Defrost Control Circuit Board with a newer version? I’m having difficulty finding a new replacement
I think the newest version is a PCBDM101S. There were a couple updates since that original board came out but that one should pull up online and be a suitable replacement if I am reading correctly. If you find one from an online supplier just call them and verify.
@ thank you i was cross reference manuals and than I ended up on the Goodman website and they told me the 101s is a replacement 130,133, 101
Thank you
I am trying to install a Lennox like this in my mom’s house to help out with her pellet stove. I bought a new pull out air handler with heat strip. It has the red, green, and blue wire but also has a black and white wire nutted together. Can you please help me out why is the black and white hooked together?
No idea. If you can send me the model number of the air handler so i can look up the wiring diagram i maybe can help. Unless the black and white wire are both meant for the heat relay...something like a auxiliary and emergency situation.
@ Lennox CBK45UHPT-36-230 And I believe the heat element is ECB45-15CB
So they must be hiding the wiring diagrams with the nuclear codes cause I couldn't find much! But i did notice on most of the other wiring diagrams that Lennox likes to use blue for 24v common. I think both the white and black wires are for heat on that 15kw heat kit you have. Look at where the white wire goes to the heat relay amd i think you'll notice there is a blue wire on the other side of the "coil" (probably a bunch of high voltage black wires going to/from the heat element itself) but the low voltage should be white and blue. I am thinking there might be 2 heat relays and the black wire would go to the second relay and then have the blue wire as the 24v common just like the white wire on the relay does. If you want to take some pics you can send it to me. We can try to make sense of it. Hard to get your head wrapped around something when you can't see it!
I've watched your sequence of events vid from 2 yrs ago. I have American Standard Freedom 80. When I call for heat, inducer motor turns on, then 3 seconds later the main blower turns on. No igniter, no gas, no flame proof. Blower stays on until I manually power unit off. Suggestions?
If the inducer is coming on and then nothing else seems to happen I would say it is likely something with the pressure switch not closing. Maybe another safety like a roll out switch or high limit?? Not exactly familiar with that particular model. Look for an error code LED that may blink/flash. BUT...if it is a pressure switch that isn't closing then you have to find out why. You could have a serious issue with a hole in the heat exchanger and that is not particularly good. I doubt it would be a bad pressure switch only. Same for a roll out issue, it likely isn't the switch that is bad. It is just doing its job.
Thanks John for more details diagram of the video and happy new year new year
Happy New Year to you as well!
Thank you so much for giving knowledge. May I know how I can reach out to you some questions with pictures of electric heat pack that I confused. Old Heat pack has 15 kw I replaced with 10 kw heat pack.old Heat pack 240 v 2 wire supply at heat pack breaker for 15 kw heat kit. At main breaker there is only 60 amp breaker. I am trying to understand how it work. I don’t see any wiring diagram. I just want to understand and study. One limit switch is wire in series with 24 v at contactor . Please let me know if you know any sources that explain how it work. Thank you
Sounds like the 15 kW didn't work good because a 10kW needs a 60 amp breaker, 15kW would need a 90 amp. The new heat pack should fit well with the power supply you described. If you would like to email me at jenningsj@hotmail.com that would be ok but I think you have it under control by the way you just described it! I'll take my email down in a few days just so it isn't out there forever. Have a good New Year.
Merry Christmas to you and your family,sir! Thank you so much for all the great lessons video that you made, it helped me a lot in the field. May I have a question for the 90340 relay? So when we in the heat mode so we have the power 24 voltage to the contactor that kick in and 240 voltage form L1 L2 power to the other side and turn on the heat strip. Then the blower fan will turn on and the terminal 2 of the 90340 relay will energize the power to terminal 1 ( speed taps) and terminal 1 to 3 will open right?
Sounds right. Power goes in on terminal 2 and 3 and then out on terminal 1 to the blower. This way no matter if you have 24 volts on the 'G' or not the PSC blower should come on.
@ thank you so much sir
Awesome awesome video.
Thank you.
Normally its your gas valve not the pressure.
Absolutley agree but i knew the guy that was booby trapping my unit. Still maybe good practice to check the pressure/adjustment if it is a brand new one?
That was good stuff. Thank you
Great job John good to see you back always enjoy your videos marry Christmas to you and your family thanks for the video
Thank you
Question: junction going into a load, it keeps going as if the load is not there....but it also flows into the load in addition to continuing along the path, right? In other words, the power flows to every touch point along the way, and keeps going?
Yes, you are correct. It powers the load and keeps going to the next one. I have seen some that think that the load (like the primary of the transformer for instance) is power for the blower motor. My point is loads don't power another load. Only power does! But you have to know the flow from the power source.
Another great job, thank you for the knowledge.
Once again, excellent video. Thanks for sharing.
Thanks John was a pleasure to know you in person and appreciate you for yours videos and all the acknowledged I received May God bless you and your family
Thank you sir. Nice to meet you. It is a small world and you never know who you are going to come across! Have a Merry Christmas and Happy New Year.
Thanks best explanation on this 90 340 relay ive ever seen esp the Right to left .. scenario used to trip me overtime if Iam adding an relay not just replacing an existing relay bc one can just go wire for wire but adding an relay for what ever reason can be tricky to some including myself
Thanks for sharing the knowledge.
Thanks for explaining the more complicated new defrost board, the old one was so simple and user friendly compared to the new one. But now I understand, Thanks
Talking to much about nothing just show the kids ho it works😊
Excellent explanation. I have the same board for a GMC furnace, however I am trying to configure the Fan only mode to blow max speed of air, right now it blows only 30% airflow speed during fan-only mode (without heat or cooling). I do not have the manual. Have any advice how to make the fan-only mode to blow 100% airflow speed? Thanks. Also during heat mode, the fan blows at 100% speed. Edit: Alright I figured it out, I simply shifted both dip switches for the "fan dip switches" to the "ON" position, this made the fan speed go on full blast. Now, I can turn on FAN-ONLY mode (without heat or cooling) at high speed.
where can I buy this clamp ?
I think that the UEI clamp has been discontinued. If you try to search and find it it is the UEI CH3. I don't even know if Amazon can get it!
Muy bueno Jenkins
great video
This really helped and saved me a boat load of $$$. Thanks so much for sharing your talent and skills with us.
For 24v purple/ orange heat dc relay would u wire one with thermostate white wire( heat) and the other to 24 common?
I think you are referring to the carrier type brands...yes. the pure/orange is 24Vac and it doesn't get to be 24Vdc until after that little board that sits on the heat relay. I have done it it before like you are saying when putting in a regular 24Vac sequencer, white to one side and common the the other side. But the plug doesn't fit a normal 1/4 so i cut the purple/orange about 6 inches away from the end and put a male and female terminal in each wire so it is an easy connection if you want to ever put back the original relay you can do it easily.
@ thank you so much. If I may ask another question. I have a wiring diagram where the ecm “speed tap” selection 2 leave in BLUE wire to a Resistor then leave in a GREY wire to the thermostats green wire ( fan). Can you please tell me the purpose of the resistor? There also 24v common fan coil wire going to it as well
I know the air handler and had one at work to look at closer...just don't know why the resistor is there! I am not sure of the resistors value either. We would probably have to call and talk to one of their engineers to get the answer. Sorry.
you have explained in a way that i would never ever forget it... all those days i have spent in class room didnt learn basic well they didnt teach the way u did and u did it in less than 40 mints thank you so much🙏
We all have and learn different ways! Maybe you have some experience now and it just hits different so you get it easier!?
I know this is an old video but I'm hoping for some help. I have a package goodman with HP and a defrost board. When calling for heat only the heat strips and blower kick on. I tested the defrost board and everything was good. Voltage in, pressure switches and a call for heat on the W terminal but nothing between common and CTR. I jumped wht to the contactor and the heat pump fired right up "proper pressures" with strips giving me a toasty 125 degrees at the supply. Figured it must be a bad board so I got one from supply, installed and the same thing. Switched it to cool and it closed the contactor after the thermostat delay was completed but would not close the CTR when calling for heat. nt suggestions would be appreciated.
Should be a call on "Y" when using heat or cool. You should have voltage on "W" only when heat strips are needed. I know some thermostats are different but if you have a 2 stage heat pump thermostat it should be like this description. Maybe the thermostat is new and not programmed correctly??
@@johnjennings-JJ Thanks. I'm thinking the problem will be the it's an old thermostat. I should have investigated further but had so many no heating calls after the cold snap I just moved on to the next since the home had heat strips working. My gut is telling me to go back and check to see if the installer wired O to Y at the unit cause the thermostat is just a 1H 1C and the heat pump hasn't worked since it was installed a couple years ago. If that's the case hopefully there's an extra wire at the tstat I can use for O and install a new tstat.
Please do a full troubleshooting on every component brother. This is a heat pump?
Could be installed in a heat pump. Could just be an all electric heat system.
My respect for Jhon this ones you tube videos ,most clear and simple for learning even if you have some knowledge about electrical and HVAC-R, god bless you great teacher, thank you for sharing.
Thank you