Very nice explain and very informative. Please make videos on Boiler heating surface Area calculation and which pressure parts are not considered for the calculation. Thank you very much
I am trom pakistan ,your all vedios are very helpful and much informative ,I appreciate you too much,. Would you please make the vedios for back pressure turbine kw calculations at different pressure in and out let with temperature difference.thanx for...
Sir, Very nice explained. Sir, please make one video on Auxiliary air dampers operation of wind box Because we are not getting thermography graph as per requirement in standard condition.. Our plant 210 mw Nasik.( Lmw) How to keep their position? Is there any Standard operating procedures? If yes please make vdo . Thank you sir..
Bhai If we increase SCH , this will increase wall thickness so in that case internal id will be reduced but it will not increase outer diameter for same size(say 2”) of pipe with different sch 40&80
Bro, needs to correct your video at 8:45 . In the case of pipe OD is always constant. Example: Pipe size: 1" it means OD is 33.4mm Pipe size is 2", it means OD of pipe is 60.3mm. If we change our schedule the ID of the pipe will change.
Sir, if we increase od of tube and decrease the Id, that time how heat will transfer. For Heat transfer both I'd and od required right. Please clarify my doubt
Sir in your discussion ,you have told that pipe is not generally used for heat transfer but in case of double pipe exchanger is used heat transfer phenomenon. So please help me !
Hello sir ji pipe ka Outer diameter hamesa same hota hai(example 2" Ka pipe ,agar alag alag Sedule ka ho to sirf internal diameter change hota hai OD fix rahata hai)
Sir, please make a video n help. How can we control LOI??? Condition is this, our mixing coal contain more than 60% les then -1. And super heater tubes are also week. Please sir
We have cooling tower COC -9. so we take 600 m3 as blow down. We have to throw it to drain. Can u suggest how to reuse this water, reduce our water loss
Bro you messed up with number 2... Pipe ka sch brhne se uska id km ho ya zayada ho ga.. Agr sch change hone se OD change ho ga to baqi fittings kese design kro ge? Like flanges? Pipe is nominated by nominal dia not OdD nor ID
Check this link for further explanation @Mech_Is_Easy Difference b/w Film Foil Sheet and Metal th-cam.com/video/1mM6fVG0qlc/w-d-xo.htmlsi=XQjUEtoqwAlYxcqL
Good Information
Thanks
Bahot acha bataye hai sir g
It will be very helpful
Excellent and very informative video thanks
Please make a video on difference of IBR tube and normal tube.
Bahut badiya sir 👍
Very good bhai
Very well discussion this topic sir..
Very nice explain and very informative.
Please make videos on Boiler heating surface Area calculation and which pressure parts are not considered for the calculation.
Thank you very much
Good explanation 👍
Supersir
Ek Detail video BCP pe bhi bana dijiye ...Plz
Bahut achha laga bhai apka video
thanks a lot bhaiya
Good explain sir....
Pathak jee plz make a vedio regarding fan chacterstist curve...
All video's very good sir ji
I am trom pakistan ,your all vedios are very helpful and much informative ,I appreciate you too much,. Would you please make the vedios for back pressure turbine kw calculations at different pressure in and out let with temperature difference.thanx for...
Thanks sir
Awesome explanation Bhai jee
Good explanation
Good information, Thnx sir..
Very nice
Thank you sir 🙏🙏
Good sir
Kindly centerifugal and steam turbine maintenance point of view .per video bnyia ga
V good sir .🎉🎉🎉🎉🎉🎉
I like it
Sir please information about induction motor rotor testing
Chiller inlet connection k bare mein pls video banaye
Nice .
Pipe schedule ki bhi video benao
Good
💯💯
Sir,
Very nice explained.
Sir, please make one video on Auxiliary air dampers operation of wind box
Because we are not getting thermography graph as per requirement in standard condition..
Our plant 210 mw Nasik.( Lmw)
How to keep their position?
Is there any Standard operating procedures? If yes please make vdo .
Thank you sir..
Sir. Turbine oil analysis par ek video please
Bhai
If we increase SCH , this will increase wall thickness so in that case internal id will be reduced but it will not increase outer diameter for same size(say 2”) of pipe with different sch 40&80
You r right
Pls share correct explanation boss...if u have
Right
U r right...for increasing or decreasing sch. Pipee ID will be decreasing and increasing respectively. ..you tuber need to correct himself
Correct.
Please make videos on turbine troubleshooting
Please make video on type of impeller of fan
Hello sir cgpsc le rha abhi boiler inspector ka question ka kuch idea de skte hai ky
Sir.. Please make video on calculating heating surface and which are the zones which we include to calculate heating surface area..
Sure dear
Sir boiler tube material ke upr video bnao❤
Bro, needs to correct your video at 8:45 . In the case of pipe OD is always constant.
Example:
Pipe size: 1" it means OD is 33.4mm
Pipe size is 2", it means OD of pipe is 60.3mm.
If we change our schedule the ID of the pipe will change.
Key diffrence
Pipe shape is always round.
Tubes shape, Round, square, Rectangular
Bro boiler superheater ko drain krne par ek video bnao
Thanks
Helo sir .please make to one video how many type of exchanger
sir, turbine rotor aur casing clearance kitna hota he.. moving aur fixed blade ka clearance kitna rehta he.. plzz explain
.05mm
Please watch my video on turbine rotor
@@chittaranjansahu8330 wrong bro....0.05mm me roll check nhi mil paayega
Pipe is denoted by nominal diameter and heat number instead of internal diameter..
Sir, if we increase od of tube and decrease the Id, that time how heat will transfer.
For Heat transfer both I'd and od required right.
Please clarify my doubt
Sir in your discussion ,you have told that pipe is not generally used for heat transfer but in case of double pipe exchanger is used heat transfer phenomenon. So please help me !
Nice🇧🇩
How can attanted interview valve technician please
Hello sir ji pipe ka Outer diameter hamesa same hota hai(example 2" Ka pipe ,agar alag alag Sedule ka ho to sirf internal diameter change hota hai OD fix rahata hai)
Pl see Is 3589. Pipes are also specified by OD
sir,
please AVGF ka ek simple video banaiye, mai pehele bhi upko request kiya tha but up bole the bad me karenge but banaye nhi..
Bna dunga dear thoda time lag skta h
At 6:30 Flow=Area×Velocity
In tube case in fire tube which u consider id or od for heating surface
sir boiler water treatment or boiler chamical k bare me ek video bnana plz
Dear I have already uploaded, please check my playlist of DMP
Sir bowl mill performance pe koi vedio banaye
Sure dear
Boiler efficiency nikalne ka video
Already uploaded
Is condensate happening in steam drum of boiler...
As per you video
Difference between pipe and tune
What about 14" pipe how is .
Is it same?
If schedule change out diameter naver change. Is it?
it's not necessary that tube always transfer heat, wrong concept. Copper tube use in plant to carry air not for heat transfer
Sir, please make a video n help.
How can we control LOI???
Condition is this, our mixing coal contain more than 60% les then -1. And super heater tubes are also week.
Please sir
We have cooling tower COC -9. so we take 600 m3 as blow down. We have to throw it to drain. Can u suggest how to reuse this water, reduce our water loss
Sir aap plz ek WhatsApp group ya telegram group banaiye
8:40 I think you are wrong. For the same NPS OD remains the same with schedule, and it is the ID that changes.
Yes I also Agree with you OD remains the same only ID change as per schedule.
Boiler me pani Ka sankulesan sir bataiye
Rong masegges. Pipe ke should badne pr id pr frank padenga sir OD pr nhi padenga steady kijiye ritern
In which book mention as you describe
Pipe ko mean diameter se denote krte hai
How to check template in drawing
Pipe ki OD fixed hoti hain
Bro you messed up with number 2... Pipe ka sch brhne se uska id km ho ya zayada ho ga.. Agr sch change hone se OD change ho ga to baqi fittings kese design kro ge? Like flanges? Pipe is nominated by nominal dia not OdD nor ID
Ist view
Thanks
Pipe od not chenge only id chenge in case of schedule changes
Tube se v to fluid flow karte hain..
Pipes are denoted by nominal diameter or NPS, not by its ID
Check this link for further explanation @Mech_Is_Easy
Difference b/w Film Foil Sheet and Metal
th-cam.com/video/1mM6fVG0qlc/w-d-xo.htmlsi=XQjUEtoqwAlYxcqL
DH-1 AND DH-2 KE DRAIN KAHA SE LIYE JATE HAI AUR KYU
I think this video should be in 2 minutes.😅
Pipe ka od fix hota hai
Sir woh FLUUD nahi FLUID hh
Pipe OD vs Sch explained is not correct...
For the same pipe size (NPS), pipe ID varies with pipe schedule.
Please delete this video and come back with more knowledge ... Don't let anyone miss guide
Thanks sir
Nice sir