Purpose of Bed Drain and Bed Charging in Boiler? | Bed Drain | Bed charging in AFBC Boiler |
ฝัง
- เผยแพร่เมื่อ 22 เม.ย. 2022
- Hello friends,
"Power plant discussion" welcome to all of you my friend to this channel, my name is chandan pathak, I have 10 years of experience in power plant operation field I have created this channel only for sharing knowledge about power plant operation and maintenance, for this I shall provide series of lecture on the various topic of power plant in which theoretical, practical and mathematical concepts are included.
Email
powerplantdiscussion@gmail.com
Website
/ @powerplantdiscussion (Company Website)
LinkedIn
/ power-plant-discussion...
#PowerPlantDiscussion
#BedDrain
#BedCharging
#AFBCboiler
Thanks to all of you for connecting me.
Sandhar explain sir...
You are very knowledgeable person ❤ The way you teach is superb
Excellent
Sir soot blower ke bare me video banav
Superb explanation sir
Good job 👍🆗👏👌👍👍👌👌👏👌👌
Super explanation sir 👍
Nice sir ji
Good
Thanks Sir
Very nice explain and informative video's.
Sir, what is the density of bed material and density of Ash and how only ash comes at the drain point only.
Thanks a lot
Sir. Downcomer tube furnace ke bahar kyu rakhte hai? And feed water pura waterwall me nahi aata par steam drum se water drum aitha steam drum me aesa kyu?
Nice sar
Super explain sir j
👌
Very good video sir
t
Very nice video
Sir,Please make a vedio boiler refrectory material
Sir boiler Compressor and condensor pr video bnaiye
We are waiting sir
sir please one vedio for what is the work of furnace internal
Sir, everything is correct and we have understood completely but this manual charging is very risky.
Sir. Ek bed me se dusre bed me Ash carryover hota ho to kya reason ho sakta hai
Sir mee plant me vacuum drop hone ke kya kya reasons ho sakte hai please video banaye ya comments me answer digiye
coal me unburn partical and lime feeding se bhi height high ho sakta hai...right sir
Sir fbc boiler main sand ku use ki jati hy?plz
Sir crude palm oil Refinery ke loss ke calculation bata dijiye
Sir I have also seen that some of the fuel particle...(like coal) also drain out through drain pipes! How is this possible...if we have AFBC boilers....?
If percentage of flyash increased in eco or aph then what should be our thinking ..
What are the merit or demerit of it ...
Sir please bed hight menten AFBC boiler par video bnaeye 🙏
Sir kitna main steam flow pe kitna FD flow rkhte h
Sir afbc boiler ke under Loi maintain kaise Krte hay uska detail chaiye
Sir boiler par load kam hone par b.f.p section chod de raha h pls reson kya h
What is difference between over bed and under bed feeding?
How to specifying top and bottom side in AFBC Boiler.??
Sir coal aur dolo char ka mixing ratio ke bare me bataiye. Kyun ki sab plant me coal 100% use nahi hota hai dolo char se boiler chalate hain. reply dijiye ga sir 🙏 mera jan na bahut jaruri hai.
Dear for this I decided to make separate video very soon got notifications.
@@PowerPlantDiscussion thank you ❤️
Sir please aap ek distillation column ka ethanol and methanol recovery ka bhi ek video banao na
Sir how line safety check in running boiler
600 mw me NH3 treatment (dosing) karte hai, if pH is 11 then what will effect
Awesome explain
Sir jab plant blackout ho jata hai to hume us time kya kerte hai, boiler per
How much iron% in bedash maintain afbc boiler ?
Normal bed tamprature kitna hona chahiye
Sir ji bed me use hone wale sand ko kya kahte hai
Sir please furnace tempcture high low par video please sir,,🙏
mobry fel hojaye to feed pump kese start kare
Can you please explain that esp not charging , even by pass drain also opened and ash handling system also working..... What's the reason.....
Sure
@@PowerPlantDiscussion thank u
Try to change ESP Controller then charge, if it charges no problem, if didn't get charge it might be the internal problem (emitting electrode might be body)
Where is null point in boiler
Sir humara plant me bed material charge nahi karte to bed material drain ho ja raha hoga aur charge nahi karte to iss se kya effect padega ya nahi?
Agr bed temperature maintain h to koi dikkat ni h
@@PowerPlantDiscussion per kuchh bed material to. Drain ho ja raha hoga,thoda thoda bed material drain hoga bed material ka percentage to kam ho jayega na.
Sir, what is difference between boiler bed material and refractory?
Hello
@@nesifkadivar7313 yes??
Pressure or steam quantity ka kya relation hota hai
For example
Suppose hum 6kg/cm2 pe 1.6ton steam produce kr rhe per hour (2TPH boiler capacity)
Now instead of 6kg/cm2 se pressure ko 8kg/cm2 pe steam generate krne lge
To 2kg/cm2 pressure increase hone se steam quantity pe kya effect pdega
As we know as pressure and temperature increases enthalpy of steam increases. So if you increase pressure or temperature steam production with high enthalpy so steam consumption is reduced
Production of Steam will remain constant
Calculate enthalpy at both conditions
And we know our turbine is design for desired heat rate, so for short period of time this can't be predict but if you want to see their effect, you should maintain constant parameters in a single shift.
Okk sir
Sir muje 267 tph boiler ke liye Ap se class lena he please sir
In which powerplant u are working
I can't share my personal info here,
Please contact me through powerplantdiscussion@gmail.com
Sir muje Ap se class lena he
Sky alloys ka ladka
Hii
Good explanation but poor in calculation.
Please suggest me what should be improvement
Please Use PPE before Bed Drain and Charge Activity.
Yes you are correct
good morning sir. sir ppe means
Personal protective equipment
Sir boiler ka heating surface area se boiler ki capacity kaise pata karenge