RULES FOR PRESSURE SETTINGS OF SAFETY VALVE || HIGHEST & LOWEST PRESSURE SETTING || [हिंदी]

แชร์
ฝัง
  • เผยแพร่เมื่อ 2 ต.ค. 2024
  • Hello friends,
    "Power plant discussion" welcome to all of you my friend to this channel, my name is chandan pathak, I have 10 years of experience in power plant operation field I have created this channel only for sharing knowledge about power plant operation and maintenance, for this I shall provide series of lecture on the various topic of power plant in which theoretical, practical and mathematical concepts are included.
    Email
    powerplantdiscussion@gmail.com
    Website
    / @powerplantdiscussion (Company Website)
    LinkedIn
    / power-plant-discussion...
    #PowerPlantDiscussion
    #PressureSettingCalculationOfSafetyValve
    Thanks to all of you for connecting me.

ความคิดเห็น • 131

  • @allinone-rk7vk
    @allinone-rk7vk 4 ปีที่แล้ว +1

    Bahut sahi bhai

  • @PankajKumar-yk9iy
    @PankajKumar-yk9iy 4 ปีที่แล้ว +4

    Mera MAWP 78.8kg/cm2 but drum pe and line pe jo safety valve lge h unpe calculation k hisaab se set pressure nhi h .. I mean k unpe jo set pressure likha h hmne waise e set Kiya h ... Like sbse Jada 78 pe rkha h...
    And kya farak pdega agar me in pressure Ko Kam rkhuga. ... And calculations k hisaab se rkhuga to kya hoga?

    • @PowerPlantDiscussion
      @PowerPlantDiscussion  4 ปีที่แล้ว +1

      Koi dikkt ni hoga, Calculation se jyada ni rkhna h bs, agr km m easy operation ho rha h to koi dikkt ni h.

    • @PankajKumar-yk9iy
      @PankajKumar-yk9iy 4 ปีที่แล้ว +2

      And sir me Kahi me pdha hu... Correct me if iam wrong k boiler ka dangerous condition kya h k apka running plant me mssv band ho jata h and apka startup vent nhi khulta ... To us condition pe teeno k teeno safety uth Jane chaiye and jitna boiler ka capacity h utna steam vent hona chahiye like 30 ton ka boiler h to 30ton teeno safety valve vent karege....

    • @PankajKumar-yk9iy
      @PankajKumar-yk9iy 4 ปีที่แล้ว +2

      And yeh jo calculation h yeh uske base pe IBR decide krta h ... Mjhe lgta h... Sir me galat hu to please correct kijiyega.....

    • @PowerPlantDiscussion
      @PowerPlantDiscussion  4 ปีที่แล้ว +2

      Ye Correct h dear

    • @PowerPlantDiscussion
      @PowerPlantDiscussion  4 ปีที่แล้ว +2

      Jo Calculation Maine video upload Kia h o IBR Calculation hi h usse Sara steam release ho jaega.

  • @yjsuccesstrack7275
    @yjsuccesstrack7275 4 ปีที่แล้ว +2

    I think one daut sir working pressure se niche aap safety valve ko kaise set kr skte hai Sir. Jaise aap bataye working pressure 80 kg and lowest safety valve setting 79 how to possible Sir. Please explain me

    • @PowerPlantDiscussion
      @PowerPlantDiscussion  4 ปีที่แล้ว +1

      Dear it's maximum working pressure which is printed on drum name plate not working pressure.

  • @Mksjoke-9120
    @Mksjoke-9120 ปีที่แล้ว +1

    Sir ek nishchit pressure se maximum ke sefty valve ka matlab Samjh aya lekin nishchit pressure se kam kyu kiya jata hai

  • @s.mgujjar2011
    @s.mgujjar2011 4 ปีที่แล้ว +2

    Sir agar hamra boiler name plate py diye mixmum Pressure py he working pressure chalya ja raha ho... I mean agar 100bar mixmum Pressure ho name plate py or itne py working ho to b setting same rahe ge...?

    • @PowerPlantDiscussion
      @PowerPlantDiscussion  4 ปีที่แล้ว +1

      Agar ap Calculation Jo bataya hu usse nikaloge jitna aayega usse Kavi v jyada pr set ni kr skte ho but plant Purana ho to usse Kam m kr skte h.

    • @s.mgujjar2011
      @s.mgujjar2011 4 ปีที่แล้ว +1

      Sir jb working pressure 100bar ho ga or likha b 100bar ho ga name plate py to ye bohat kam ho jae ga is haisb sy turbine ki Trip hone ki surat me problem ban sakte ya achnk thora load boiler py kam ho ga to sefty valve uth jae ga foran

  • @sanjibsahoo3972
    @sanjibsahoo3972 3 ปีที่แล้ว

    Very nice sir

  • @abhishekupadhyay5448
    @abhishekupadhyay5448 2 ปีที่แล้ว +1

    Three elements boiler drum control p vdo banaye

  • @rahulsatyam1605
    @rahulsatyam1605 4 ปีที่แล้ว +3

    How set safety valve Sr please

    • @PowerPlantDiscussion
      @PowerPlantDiscussion  4 ปีที่แล้ว +1

      Dear please watch my video on working and principles of safety valve I have explained this point in very detail way.
      Thanks

  • @ammaduddin2634
    @ammaduddin2634 3 ปีที่แล้ว +1

    Hello sir

  • @Afzalkhan-zl3ir
    @Afzalkhan-zl3ir 4 ปีที่แล้ว +4

    How to possible of set point of safety valve is max working press above 3%

    • @PowerPlantDiscussion
      @PowerPlantDiscussion  4 ปีที่แล้ว +3

      Pressure settings always below design pressure, highest pressure settings not exceeding 3% of permissible working pressure, and another set at permissible working pressure or below it.

  • @PankajKumar-yk9iy
    @PankajKumar-yk9iy 4 ปีที่แล้ว +1

    Sir ek question h maine boht logo se puch par proper answer nhi Mila ... Like safety valve me spring h to Apne aksar dekha hoga spring pe agar Maan lo koi wt rkha jaise ki 10kg and spring db jata h ... And jaise e me 10 kg hta du to spring apna shape retain kr leta h.... To fir safety valve me agar 73 kg/cm2 pe uthta h ..... And yeh b to ek spring h to fir 73 kg pe hi ku nhi baith jata means k reset pressure ku Kam hota h set pressure se...

    • @PowerPlantDiscussion
      @PowerPlantDiscussion  4 ปีที่แล้ว +1

      Jo Apne 10kg weight Ka example lie h usme weight hatane k bad us pr koi v external pressure ni rhta h, but Jo 73kg k case m apka 73kg pr ate hi uth jata aur but us pr steam Ka Pressure continue applied rhta h jisse o close ni hota h, apka 10kg weight k example se smjh lete h man lo ap 1kg kewal weight ko hataye h Yani 9kg weight h av to kya spring Pura Apne original position m retain ho jaega? Kavi ni hoga Uske upr koi load ni Hona chahie tv o Apne original position m aayega, similarly steam Ka Pressure always applied rhta h disc pr jb spring force applied steam force se jyada hoga tv usko stop krega, ni to safety valve hamesa up down krte rhega jisee chattering kahte Jo ki seat aur disc ko damage kr deta h, simple way m drum m Jo Pani inlet krwate ho uska same Pressure rkhoge to kya Pani drum m jaega?

    • @PankajKumar-yk9iy
      @PankajKumar-yk9iy 4 ปีที่แล้ว +2

      @@PowerPlantDiscussion sir yeh baat to me smjh geya but set pressure se Kam hi ku but 73 se upar geya to safety uthega.... And wapis after venting significant amount of steam it again attains 73 kg/cm2 pressure, then my question is k ab to 73 kg h to ku nhi baith rha safety valve....

    • @PowerPlantDiscussion
      @PowerPlantDiscussion  4 ปีที่แล้ว +1

      Q ki disc pr applied force aur spring force same h to kaise bnd hoga Kisi ko km Hona chahie n Yani bnd hone k lie steam applied force Kam hoga tv spring force close krega.

  • @mdsarfraj658
    @mdsarfraj658 2 ปีที่แล้ว +1

    Blowdown % kitna standard value hota h ?

  • @maharajagasti8330
    @maharajagasti8330 4 ปีที่แล้ว +1

    👏👏👏👌

  • @RajendraKumar-kr7hx
    @RajendraKumar-kr7hx 4 ปีที่แล้ว +1

    Why we can not continue operate any boiler to maximum working pressure

  • @ammannag7610
    @ammannag7610 2 ปีที่แล้ว

    ERV working condition tell me
    Please bhai

  • @Knowledgebooster708
    @Knowledgebooster708 2 ปีที่แล้ว

    max working pressure hamesa RHS safety valve mein hi kyu set krte hai??

  • @niladreesengupta7168
    @niladreesengupta7168 ปีที่แล้ว

    Ek baat boliyai 43kg working pr hai and mwp 52kg hai to drum sv pr kitna hoga and line pr kitna hoga

  • @RajenderKumar-od1yg
    @RajenderKumar-od1yg 3 ปีที่แล้ว

    Chandan ji heating surface nikalne ka farmula batayen

  • @niladreesengupta7168
    @niladreesengupta7168 ปีที่แล้ว

    Abhi tak hum log dekhai hain both drum pr sv pr settings 1kg difference par hota hai plz iska answers de😊

  • @abhimanyudas132
    @abhimanyudas132 3 ปีที่แล้ว

    Hamara boiler ka working pressure 100bar hai lekin drum ka pressure 116 kg hai kya app jo rule bol rahe ho wo lagu hoga kya
    High pressure boiler me jaha par super heater laga hua hai

  • @neerajpokhriyal7958
    @neerajpokhriyal7958 2 ปีที่แล้ว +1

    Sir agr nhi likha hoga to max wrkng pressure fir kya karenge?

    • @PowerPlantDiscussion
      @PowerPlantDiscussion  2 ปีที่แล้ว

      Value to manufacturer provide krte hi h dear

    • @neerajpokhriyal7958
      @neerajpokhriyal7958 2 ปีที่แล้ว

      @@PowerPlantDiscussion bcz sir asme regulation k hisab se alg aata hbor design manufavtur k hisab se alg..

  • @PramodYadav-cr6ll
    @PramodYadav-cr6ll 2 ปีที่แล้ว

    Sir superheater bhi ibr me aata hai ki nahi inspection ke samay superheater ka bhi dydraulic test lete hai ki nahi .

  • @entertainmentrk2949
    @entertainmentrk2949 4 ปีที่แล้ว +1

    Can be hydro test multy new and old boiler depends on working pressure

  • @prakashchoudhry8891
    @prakashchoudhry8891 4 ปีที่แล้ว +1

    Sar app hame ye btaye working pressure ham jada set kar skte hai kia ibr rules ke mutabik hamne maximum warkin pressure se jada app bta rhe hai app ayesa hota hai please

    • @PowerPlantDiscussion
      @PowerPlantDiscussion  4 ปีที่แล้ว

      Dear maximum working pressure pr hi set Kia Jata h, but Kisi v case m design Pressure of Boiler se safety Valve set Pressure Kam hi rkha Jata h.

    • @PowerPlantDiscussion
      @PowerPlantDiscussion  4 ปีที่แล้ว

      Design Pressure and maximum working pressure m bahut difference h

    • @prakashchoudhry8891
      @prakashchoudhry8891 3 ปีที่แล้ว

      @@PowerPlantDiscussion
      Sar is pe yek video bnaye please ham ko link beje watch krne ke liye please

  • @sivaramnimmala458
    @sivaramnimmala458 4 ปีที่แล้ว +2

    Muze 3&1element ke baare me msg kizeye

  • @muhammadzubair-vj2zw
    @muhammadzubair-vj2zw ปีที่แล้ว

    Nice love From Pakistan

  • @PramodYadav-cr6ll
    @PramodYadav-cr6ll 2 ปีที่แล้ว

    Sir pressure guage ke working par bhi koi video banaiye .

  • @oclahmed1173
    @oclahmed1173 3 ปีที่แล้ว

    Governor hunting ki reasons kya hn

  • @ashwin4624
    @ashwin4624 3 ปีที่แล้ว +1

    Logic doubt it means boiler drum ka steam pressure super heater ke safety valve setting bar se kam hoga am i right???

  • @vijaylalyadav8706
    @vijaylalyadav8706 4 ปีที่แล้ว

    बायलर का मोस्ट सेफ्टी क्या है

  • @santoshnath1383
    @santoshnath1383 4 ปีที่แล้ว +1

    Bhai turbine related videos banao.......

  • @funwithsuyog
    @funwithsuyog 2 ปีที่แล้ว +1

    LONG DAY DOUBT CLEAR.

  • @indianrailwaysjob2637
    @indianrailwaysjob2637 4 ปีที่แล้ว +2

    Good explain bhiya

  • @needjob4359
    @needjob4359 4 ปีที่แล้ว +1

    Please working pressure ka bare ma btae???

  • @leeladharsahu7653
    @leeladharsahu7653 4 ปีที่แล้ว +2

    Boiler hydro test ka pressure increasin & reducind ka ratio kitna hota hai

    • @PowerPlantDiscussion
      @PowerPlantDiscussion  4 ปีที่แล้ว +1

      Increase rate mainly 3kg/cm2 in One minute for best result.

  • @janardhangedela592
    @janardhangedela592 9 หลายเดือนก่อน

    Thank you

  • @akdgkp7957
    @akdgkp7957 ปีที่แล้ว

    Thank you

  • @ammaduddin2634
    @ammaduddin2634 3 ปีที่แล้ว +1

    I am working as senior Operations engineer combine cycle power plant 32 gas engine+ 32 HrSG+steam turbine

  • @ramesh40634
    @ramesh40634 3 ปีที่แล้ว

    Super

  • @ashwin4624
    @ashwin4624 3 ปีที่แล้ว +1

    Ye boiler drum ka steam ka pressure aur superheater tube ke inside ka steam pressure same hota hai kya? Ya fir boiler drum ke compare me superheater ke steam ka press kam hota hai? Plz answer

    • @PowerPlantDiscussion
      @PowerPlantDiscussion  3 ปีที่แล้ว

      Superheater m steam ka pressure kam rhta h, ap dekhe honge superheater tube inlet m reducer lga rhta hai, agr pressure jyada rhega to steam ka flow kaise hoga, Q ki kv v high pressure low pressure K trf flow krta h.

  • @Gmasskidsclub.
    @Gmasskidsclub. 4 ปีที่แล้ว +2

    You explanation is very good..

  • @muhammadadam523
    @muhammadadam523 2 ปีที่แล้ว

    Vip

  • @ammaduddin2634
    @ammaduddin2634 3 ปีที่แล้ว +1

    Kindly make videos on ACC AIR COOLED CONDENSER

  • @abhimanyudas132
    @abhimanyudas132 3 ปีที่แล้ว

    High pressure boiler me kese rule apply karege if working pr 100bar. Drum and main steam line me safety valve pressure kitna hoga pls comet

  • @pankajsahu4581
    @pankajsahu4581 4 ปีที่แล้ว +1

    Mwp 80 kg h or safty valve 79 kg or 80 kg boiler drum ki and super heater ki 72 h to boiler ko 75 kg mein chalige to super heater ki safty valve open nahi ho ge kya

    • @PowerPlantDiscussion
      @PowerPlantDiscussion  4 ปีที่แล้ว

      Jarur Hoga

    • @ashwin4624
      @ashwin4624 3 ปีที่แล้ว

      @@PowerPlantDiscussion it means boiler drum steam ka pressure 72 se niche rahega right?

  • @aerowind87
    @aerowind87 2 ปีที่แล้ว

    Sir can you clarify which IBR regulation..number...specifies about minimum number of safety valve
    Also can u specify regulation mentioning the pressure setting ..rules which you have mentioned

  • @ammaduddin2634
    @ammaduddin2634 3 ปีที่แล้ว +1

    Your videos too much helping for understanding the steam turbine power plant

  • @nandanchowhan6016
    @nandanchowhan6016 4 ปีที่แล้ว +1

    Sir good evening
    This is nandan chauhan
    Actually I want to separate video on whrb so please

  • @pankajlanjewar7575
    @pankajlanjewar7575 3 ปีที่แล้ว

    सर्, अगर पावर प्लांट में लोड कम हुआ तो जनरेटर की speed मेन्टेन करके लोड कैसे manage करते है?

  • @powerplant413
    @powerplant413 2 ปีที่แล้ว

    🙏🙏🙏

  • @ranjankumarswainswain573
    @ranjankumarswainswain573 ปีที่แล้ว

    Sir, as per calculation safety v/v operating pressure pe set kar dengey, but kitna pressure pe blow down set karenge

  • @shailendrajadon3599
    @shailendrajadon3599 4 ปีที่แล้ว +1

    Good evening sir... Next video kab aaraha hai.. I m waiting.. Your video is very helpful .. Thanks sir.. For update in this video...

  • @gaganshrivastava1998
    @gaganshrivastava1998 4 ปีที่แล้ว +1

    Sir plz ek video generator hydrogen cooling mi banaye

  • @mohitkumar-hh2vy
    @mohitkumar-hh2vy 9 หลายเดือนก่อน

    Vgod information sir about the same
    Hartley thanks

  • @ubaidullah9674
    @ubaidullah9674 4 หลายเดือนก่อน

  • @manojverma9317
    @manojverma9317 3 ปีที่แล้ว

    Is it necessary to line up Cooling water in condenser before putting STG in heating,why

  • @praveenkulkarni625
    @praveenkulkarni625 4 ปีที่แล้ว

    The information is incorrect.

    • @PowerPlantDiscussion
      @PowerPlantDiscussion  4 ปีที่แล้ว

      Please mention correct data if you have Available, because this described data is taken from book I think this is correct towards me.

  • @MuhammadAmjad-ol8nx
    @MuhammadAmjad-ol8nx 4 ปีที่แล้ว +1

    Thanks,

  • @needjob4359
    @needjob4359 4 ปีที่แล้ว +1

    Thanks...

  • @gurusharanjitsingh9153
    @gurusharanjitsingh9153 4 ปีที่แล้ว

    LHS SV hi highest pressure pe set krna chahiye kya?Jaise maine padha hai ki steam drum ka lower portion bahot minor slope ya tapper hota hai ek side ko toh LHS ko max pressure set ka yehi reason hai???

  • @elangoduraisamy5089
    @elangoduraisamy5089 3 ปีที่แล้ว

    Thanks for useful information. How to set the pop up pressure in safety valve. Any calculation for spring tension and adjusting ring.

  • @manojmaji4301
    @manojmaji4301 3 ปีที่แล้ว

    R.H.S ya L.H.S drum safety valve ka setting konsa zyada rahta he and kyu?

  • @vijayjeeva3590
    @vijayjeeva3590 2 ปีที่แล้ว

    Sir, i need reason for boiler wall thickness in top is more than bottom.. thanks

  • @Dkscreations4022
    @Dkscreations4022 4 ปีที่แล้ว

    Valve's ke upor video bonao

  • @RohitGupta-ez5fq
    @RohitGupta-ez5fq 3 ปีที่แล้ว +1

    Sir why two safety valves are provided on drum ? Is there any rule for this

    • @PowerPlantDiscussion
      @PowerPlantDiscussion  3 ปีที่แล้ว +2

      Yes dear it's under IBR rule, for boiler protection if incase of one safety valve is not popup during high pressure chances of second will pop-up which protect over pressure

    • @RohitGupta-ez5fq
      @RohitGupta-ez5fq 3 ปีที่แล้ว

      @@PowerPlantDiscussion thank you sir

  • @kebinfernando6158
    @kebinfernando6158 3 ปีที่แล้ว

    Very nice explanation.. good luck sir

  • @needjob4359
    @needjob4359 4 ปีที่แล้ว +1

    Working pressure sa pressure ha???

  • @kalpatarumajhi7344
    @kalpatarumajhi7344 7 หลายเดือนก่อน

    Best regards to you.

  • @HaroonUAE1116
    @HaroonUAE1116 4 ปีที่แล้ว

    Thanks dear very useful video
    God bless u always

  • @DAVIDJOHNSON-te6jc
    @DAVIDJOHNSON-te6jc ปีที่แล้ว

    Bahut badhiya sir

  • @amolbhoi4822
    @amolbhoi4822 3 ปีที่แล้ว +1

    Nice sir

  • @mukeshkur3557
    @mukeshkur3557 4 ปีที่แล้ว

    Kamalesh Gupta
    Nice vdo

  • @govindpatel7035
    @govindpatel7035 4 ปีที่แล้ว

    Very good
    How much pressure difference should be in between Blowdown pressure of safety valve & pop-up pressure ?
    How to calculate it?

    • @PowerPlantDiscussion
      @PowerPlantDiscussion  4 ปีที่แล้ว +2

      I have completed a separate video on this topic, very soon I'll upload

  • @diliprawat4477
    @diliprawat4477 3 ปีที่แล้ว +1

    Supar sir ji

  • @pradipdan6679
    @pradipdan6679 4 ปีที่แล้ว

    Sir
    Aap achha se samjhate hai.

  • @pkentertainer4824
    @pkentertainer4824 4 ปีที่แล้ว

    Very informative video sir

  • @kameshyadav3084
    @kameshyadav3084 4 ปีที่แล้ว

    Nice sir

  • @santoshkumar-cf1pv
    @santoshkumar-cf1pv 4 ปีที่แล้ว +1

    Thank you sir, very useful knowledge.sir please reply.
    1)Any formula for reset pressure.
    2)Can a super heater savety valve be used as a drum savety valve?

  • @AVoyagerCouple
    @AVoyagerCouple ปีที่แล้ว

    Thanks for the important information. Can you please clarify me about the difference between the maximum working pressure and designed pressure.

  • @anilkumar9570
    @anilkumar9570 4 ปีที่แล้ว

    Saftey valve ki setting drum pe jo likha hua hota hai usi ke according hi kiya jata hai yaa jo hamara working pressure hai spouse my working pressure is 66kg/cm² uske according bhi kiya ja sakta hai kya please tell me sir?

    • @PowerPlantDiscussion
      @PowerPlantDiscussion  4 ปีที่แล้ว +1

      Drum pr name plate m Jo maximum working pressure hota h usse set Kia jata h