  • @repmservices3009
    @repmservices3009 3 ปีที่แล้ว +1

    You are AWESOME!!! We learned so much!!! Your videos are perfect!!!

    • @spaman5440
      @spaman5440  3 ปีที่แล้ว

      Thank You for Watching &SUBSCRINING

  • @davidh3152
    @davidh3152 9 หลายเดือนก่อน +1

    Spa Man, thanks for your videos. What are your thoughts on bonding the Balboa controller pack to the pumps using non-insulated 8 guage wire. From what I've read it is not REQUIRED, but would it hurt to bond them to the controller using the grounding bus on the outside of the controller box? Thank you

    • @spaman5440
      @spaman5440  9 หลายเดือนก่อน +1

      That is the way it is done with almost all of the hot tubs I see.I would not myself go any smaller then #6 wire because that is the only size wire that I use. Thanks for Watching & SUBSCRIBING

  • @JosephLange-j6u
    @JosephLange-j6u ปีที่แล้ว

    Do you have any videos wiring a spa builder pack on a dynasty tub?

  • @mitbbew6901
    @mitbbew6901 5 หลายเดือนก่อน +1

    Ok I have a balboa hot tub. 50a breaker #6 wire. I noticed the Balboa has a SC-30 FUSE rated 30a. Im ok there?

  • @racebumtv8398
    @racebumtv8398 3 ปีที่แล้ว +1

    Great video vert helpful and to the point. Keep it up.

    • @spaman5440
      @spaman5440  3 ปีที่แล้ว

      Thanks, will do!

  • @WeatherNut27
    @WeatherNut27 2 ปีที่แล้ว

    Nice video! I cant find where to plug in my ET-H4000 heater wire on a KL6600UL74B board. Old heater was spliced with leads, new heater has the clip

  • @Mike-mn9xo
    @Mike-mn9xo 2 ปีที่แล้ว +1

    Will the balboa accommodate #4 wire? I bought a 20ft swimspa the hot tub requires 50amp and poolside requires 60amp. I ran # for the poolside .

    • @spaman5440
      @spaman5440  2 ปีที่แล้ว

      No it will not the largest wire Ive been able to get in a Balboa pack was #6

    • @Mike-mn9xo
      @Mike-mn9xo 2 ปีที่แล้ว

      @@spaman5440 awesome thanks . My swimspa company is pretty useless on wiring spec . I went off # 4 due to 60 amp load . Thanks again

  • @carriv
    @carriv 2 ปีที่แล้ว

    For jacuzzis that dont require a neutral, do they still require a ground fault circuit breaker with a neutral pigtail? If so, is the neutral pigtail still connected in the panel? Thanks!

  • @chase9118
    @chase9118 2 ปีที่แล้ว +1

    Hi SpaMan.
    My board blew on my old 2008 Vitaspa. Noit sure why, but It had a 3 wire 30 amp power supply line w/ 10 guage wire...I found a Spa control pack on ebay, but its a 4 wire 40 amp board. Is that something I can hook up to this without changing the line to a 4 wire or changing the breaker?? How do you hook up a 3 wire line (L1 L2 G) to a 4 Wire Spa board? What do you do with the Neutral connection for the board if you don't have a wire for it?

    • @spaman5440
      @spaman5440  2 ปีที่แล้ว

      You have a ton of Red flag that just went off ..We do not want to confuse other viewers with a similar problem to your and then they blow up there hot tub..I would call the office and talk to Scott. You have a lot going on. Thanks for Watching & SUBSCRIBING

  • @TravelShortcuts
    @TravelShortcuts 9 หลายเดือนก่อน

    Great vid brother

  • @templarstringham4854
    @templarstringham4854 3 ปีที่แล้ว +1

    If you have a three wire hot tub setup where does the neutral or white wire go? Isn’t the white or neutral wire required so that the GFCI works properly?

    • @spaman5440
      @spaman5440  3 ปีที่แล้ว

      We did a video about how to wire up a 3 wire Hot Tub that will help You ...If you still not sure you can call the shop and talk to Scott Thanks for Watching & SUBSCRIBING

  • @nsikakemeh1130
    @nsikakemeh1130 3 ปีที่แล้ว

    What if you have 4 wire going for the pump with single phase red,black and greg plus the ground. How will you connect it

  • @GeorgeFernandez-uz4js
    @GeorgeFernandez-uz4js 9 หลายเดือนก่อน +1

    What if u have 4 wire to tub from main but only 3 wire whip but four wire h.t. can it still be connected

    • @spaman5440
      @spaman5440  9 หลายเดือนก่อน

      NO! ....If its a four wire Hot Tub you have to have all four wires to run it.. Two hot wires one neutral and one ground Thanks for Watching & SUBSCRIBING

  • @BWCA-vy2pi
    @BWCA-vy2pi 3 ปีที่แล้ว

    Thanks for your videos! We are getting a Master Spa 7.25 which calls for a 50 amp four wire. We are already set up with a 60 amp breaker on the main panel and a 60 amp GFI in the spa panel with all 6 ga wire. Is it total fine to run the new tub with this set up or should I replace the 60's for 50's to be totally safe? Thanks!

  • @TheRuggedChannel
    @TheRuggedChannel 2 ปีที่แล้ว

    My electrician did not use a black wire what he did he used 2 red wires but inside spa pack he marked one of the wires with black tape but inside of gcf breaker box he did not mark one of the red wires in their so I don't know which one is black and which one is red. Does it matter?

  • @woar3307
    @woar3307 4 หลายเดือนก่อน +1

    Thank you

  • @Sloane122
    @Sloane122 ปีที่แล้ว

    How do you wire a grande from hot springs hot tub

  • @jenardbolt123
    @jenardbolt123 2 ปีที่แล้ว +1

    AWESOME!!

  • @bertricaldi5104
    @bertricaldi5104 3 ปีที่แล้ว

    thank you who you recomend in Rhode Island

  • @AA-ol6fl
    @AA-ol6fl 2 ปีที่แล้ว

    Hey Spa man on my balboa the label is colored different than what is says on motherboard … which one should I follow ?

    • @AA-ol6fl
      @AA-ol6fl 2 ปีที่แล้ว

      Well I followed the motherboard coding and that blew the gfi immediately so I guess it’s follow the label

  • @DavidAnderson-on5ce
    @DavidAnderson-on5ce 2 หลายเดือนก่อน +1

    I have. Balboa v 500 it was heating to 100 it popped ireset now only heats87 please help

    • @spaman5440
      @spaman5440  2 หลายเดือนก่อน

      You are most likely in the wrong MODE locate your owner manual and make sure you are in STANDARD Mode (STD)
      Thanks for Watching & SUBSCRIBING

  • @stupidmonkey8859
    @stupidmonkey8859 2 ปีที่แล้ว +1

    I got an old hot tub. 3 wire. How do tell if it's 110 or 220?

    • @spaman5440
      @spaman5440  2 ปีที่แล้ว +1

      If you go to the back side of the spa pack cover it will tell you If you are still having trouble you can call the shop and talk to Scott and he can help you figure it out.Thanks for Watching & SUBSCRIBING

    • @stupidmonkey8859
      @stupidmonkey8859 2 ปีที่แล้ว +1

      @@spaman5440 ok. It's 20 years old and the tag is faded and not readable.

    • @spaman5440
      @spaman5440  2 ปีที่แล้ว

      @@stupidmonkey8859 I would call the shop and talk to Scott..Thanks for Watching & SUBSCRIBING

  • @captaintenfour
    @captaintenfour 3 ปีที่แล้ว +1

    show me how you connect one with #6 teck cable

    • @spaman5440
      @spaman5440  3 ปีที่แล้ว

      Ive seen Teck cable cause problems with Hot Tubs and because of that I can not recommend using it for any type of Spa installation. Thanks for Watching & SUBSCRIBING

  • @patriotveteranauto
    @patriotveteranauto 6 หลายเดือนก่อน +1

    could you spend more time on the Balboa 54381 I seriously dont mind venmo you for services or advice . i got a customer wired it themselves and fried 2 boards i believe he wired the same . On the board between its a viking VKV502 its burnt on the board between w7and the slow blow fuse .

    • @spaman5440
      @spaman5440  6 หลายเดือนก่อน +1

      I would need to see how it is wired...
      The fact that two boards have been fried tells me it is wired wrong. in cases like this I always start with the main checking wiring / breaker then move on to sub disconnect and again make sure everything is wired correct then move on to the pack
      In the pack I would disconnect every thing
      I have ways in the field to check motors and I would check them first to make sure they are good.
      The fact that two boards fried tells me something was done wrong.
      Hope this Helps Feel free to call the office and talk to Scott to see his thoughts. Thanks for Watching & SUBSCRIBING

    • @patriotveteranauto
      @patriotveteranauto 6 หลายเดือนก่อน +1

      @@spaman5440 Thank you for the help , I agree what i can tell is they mis identified the plug for the pump2 he landed it on the Circ pump not the Pump2 the spa does not have the optional Circ pump installed.
      so it had to have been the issue. Im going to ohm out the motors and see if they are dead short or open , but yes i ordered him a new board to replace the other 2 he burnt up . Thank you again i hope others can benefit of these comments.

  • @NorthPolePaul
    @NorthPolePaul 3 ปีที่แล้ว

    do you have a website for parts, and would you be willing to help me figure out the parts I need to repair and update an older tub that came with the house I bought? By the way I'm in Alaska.

    • @spaman5440
      @spaman5440  3 ปีที่แล้ว

      Sure we can Help you...Call the Arizona Hot Tub Factory and ask for Scott he will be able to help You. Thanks for Watching & SUBSCRIBING

  • @6ixBOI
    @6ixBOI 5 หลายเดือนก่อน +1

    Spa man I have a Amish spring old hot tub how can I splice a extension cord to the main power plug

    • @spaman5440
      @spaman5440  5 หลายเดือนก่อน

      We would need more Info to help you.

    • @6ixBOI
      @6ixBOI 5 หลายเดือนก่อน

      @@spaman5440 it’s a Amish spring spa from the 1990s the plug for it is not long enough to reach an outlet so I will need to splice it to my breaker box or could I just splice the power cord from the hot tub to a extension cord and just simply plug it in

  • @slickmick7114
    @slickmick7114 5 หลายเดือนก่อน +1

    Ur pretty cool dude 🫡

    • @spaman5440
      @spaman5440  5 หลายเดือนก่อน +1

      Thank you Sir
      And Thanks for Watching & SUBSCRIBING

  • @joels.7836
    @joels.7836 3 ปีที่แล้ว +1

    My cuestión is why #6 wire for 50 amps if #8 its for 50???? Its my cuestión

    • @spaman5440
      @spaman5440  3 ปีที่แล้ว

      There is a little more to it then that.. You can call the office and talk to Scott and he can explain it to you...there is a reason behind why You don't use #8 Thanks for watching and SUBSCRIBING

    • @joels.7836
      @joels.7836 3 ปีที่แล้ว +1

      Mr spa man under the nec code 40 -50 spa its # 8 and 60 # 6 3 wires i live on dallas . Its different to arizona or why #6 on 50 amps hot tube?

    • @spaman5440
      @spaman5440  3 ปีที่แล้ว

      @@joels.7836I would like to thank you for sharing with me and others what the NEC code says..( You should go back and read it again)...Just because it meets code and might pass an inspection doesn't mean you will not have several problems with your hot tub..But what do I know ...