Alarm Check Valve Assembly Process

แชร์
ฝัง
  • เผยแพร่เมื่อ 3 พ.ย. 2019
  • Alarm Check Valve Assembly Process
    Wanna buy alarm check valve from a real manufacturer?
    Feel free to contact me:
    Contact Information: Diyong Liang(Mr.)
    Email (first choice): diyongliangmr@siifuu.com
    Website: www.siifuu.com
    Mob./Wechat/QQ/Facebook/WhatsApp/Skype:+86 18606963202
  • วิทยาศาสตร์และเทคโนโลยี

ความคิดเห็น • 20

  • @csonracsonra9962
    @csonracsonra9962 2 ปีที่แล้ว +1

    Thanks to all three of you men who apparently were too awkward to speak and guide along with what you were doing

  • @chamboadventures6781
    @chamboadventures6781 ปีที่แล้ว

    Pipe works a bit loose , use some ptfe tape

    • @siifuu
      @siifuu  ปีที่แล้ว

      Yes, thanks. This is just a guiding video to show our customers how to assemble the valve.

  • @its_me__Akshay
    @its_me__Akshay 2 ปีที่แล้ว

    is there a NRV inside of an ICV..?

    • @siifuu
      @siifuu  2 ปีที่แล้ว +1

      yes

  • @storm_bringer2266
    @storm_bringer2266 ปีที่แล้ว

    does the inlet pressure gauge reading is always higher than system pressure gauge reading? (wet type sprinkler system)

    • @siifuu
      @siifuu  ปีที่แล้ว

      No, they will be the same. Or, the system side pressure will be higher than the inlet side pressure.
      Because there's a pressure compensation device(one way), so if the system side has something like a little leakage that causes pressure drop, a little stream of water will flows through compensation device, into the system side to keep both sides have the same pressure.
      2nd, becuase the height of water causes pressure increasing in the system side guage, and the water will not possible to flow into the water inlet side. So, the system side gauge may has a higher reading than the inlet side.

    • @storm_bringer2266
      @storm_bringer2266 ปีที่แล้ว

      @@siifuu oh, my inlet pressure reading is 250psi and system pressure is 220psi in standby mode.. what is the problem about this?

    • @siifuu
      @siifuu  9 หลายเดือนก่อน

      @@storm_bringer2266 this is not a common sense. Check to see if there's a leakage on the system side or valve trim, check to see whether the pressure gauge damaged or not.

  • @SonuYadav-eb5ke
    @SonuYadav-eb5ke 3 ปีที่แล้ว

    Show inside alarm valve

    • @siifuu
      @siifuu  3 ปีที่แล้ว

      Email me, diyongliangmr@foxmail.com, I will send you more details.

  • @SonuYadav-eb5ke
    @SonuYadav-eb5ke 3 ปีที่แล้ว

    Please tell name number waise part fitting

    • @siifuu
      @siifuu  3 ปีที่แล้ว

      Email me, diyongliangmr@foxmail.com, I will send you more details.

  • @lenphil9875
    @lenphil9875 2 ปีที่แล้ว

    Why is there a connection between the gauges?

    • @siifuu
      @siifuu  2 ปีที่แล้ว +1

      It's a pressure compensating device to keep the upper chamber has a same pressure with lower side while set condition.

    • @lenphil9875
      @lenphil9875 2 ปีที่แล้ว

      @@siifuu Thankyou. Makes sense now.

  • @SonuYadav-eb5ke
    @SonuYadav-eb5ke 3 ปีที่แล้ว

    How to work

    • @siifuu
      @siifuu  3 ปีที่แล้ว

      th-cam.com/video/yv6TExFIv0c/w-d-xo.html

    • @siifuu
      @siifuu  3 ปีที่แล้ว

      This video for your reference

    • @ebereisaac3687
      @ebereisaac3687 3 ปีที่แล้ว

      How