fire pumps installation details

แชร์
ฝัง
  • เผยแพร่เมื่อ 28 ส.ค. 2024
  • fire pumps installation details
    visit for comphansive details..Thanks
    informations786...

ความคิดเห็น • 177

  • @badmusbabatunde4724
    @badmusbabatunde4724 2 วันที่ผ่านมา

    Hello...thank you for this video. I find it very useful and informative every time I come to watch it. You didn't upload the detail drawing as promised all these while. I can't find it on your telegram channel too. Kindly upload it. Thank you

  • @uzairmalik498
    @uzairmalik498 5 ปีที่แล้ว +1

    Good video....World is moving towards standardization. Last month I was working on a project in 62 story building in Karachi and observed the same fire suppression system.

  • @ramsiramsath
    @ramsiramsath 4 ปีที่แล้ว +2

    Hi, If the pump room is designed as per NFPA 20 requirement, you should keep 10d of suction line. and some more i found.

  • @mohammedmakeen9132
    @mohammedmakeen9132 6 ปีที่แล้ว

    appreciate your hard work for us afreen Bhai...keep sharing knowledge..very helpful

  • @paulsmith7639
    @paulsmith7639 5 ปีที่แล้ว +1

    The suction reducer is installed incorrectly. The float of the reducer should be on the top to prevent air traps. It’s upside down!

  • @paulsmith7639
    @paulsmith7639 5 ปีที่แล้ว +3

    Also the auto air vent valve is missing a top U bend to prevent contamination ingress.

  • @zealotleader5203
    @zealotleader5203 5 ปีที่แล้ว

    Hello
    What you say about it?
    I THINK if the source of supply is above the pump,the eccentric reducer must be placed with the flat side down.. you are correct in this

  • @yunuspervez4702
    @yunuspervez4702 3 ปีที่แล้ว +2

    Eccentric reducer in pump suction should have flat top.

  • @akilinayat9595
    @akilinayat9595 2 ปีที่แล้ว

    Glycerol filled pressure gauges to be used with syphon arrangment.
    Manhole door is not provided for diesel tank for yearly cleaning tank.
    Level gauge is also not provided to diesel tank for diesel level checking
    Batteries terminal, plastic protection caps are not provided.

  • @sudarsansahoo8449
    @sudarsansahoo8449 6 ปีที่แล้ว

    Afreen Bhai mujhe Khushi hui is bat ki aap fire safety ki jankari bataya magar ek chig adhura rahagai aap har fire motor Ka pressure kg aur agar Kisi motor lineme Pani Kam ho yaniki pressure Kam hojaye kya Karna padega

  • @rods1812
    @rods1812 7 ปีที่แล้ว +9

    Hi friend... the excentric reducer flat side must be on top and de reduction side on bottom.. this is to prevent the formation of air pockets on the suction pipe..

    • @afreenali
      @afreenali  7 ปีที่แล้ว

      Thanks for You are right

    • @afreenali
      @afreenali  7 ปีที่แล้ว

      th-cam.com/video/iIDspuse0Jc/w-d-xo.html

    • @afreenali
      @afreenali  7 ปีที่แล้ว

      th-cam.com/video/90T7pGKk1mc/w-d-xo.html

    • @haleemfp
      @haleemfp 6 ปีที่แล้ว

      I was about to say this.... in this case if installation, air trapped and goes to impeller. Thereby the effect of cavitation increase and will heat and damage the pump.
      What I said is as per nfpa 20.

    • @gettingintoaction1
      @gettingintoaction1 6 ปีที่แล้ว +1

      Flat side of Eccentric reducer should be down , when source of supply is above pump and vice versa.

  • @SuperRancell
    @SuperRancell 4 ปีที่แล้ว

    FOR HVAC PUMPING DESING
    Hi thanks a lot for you videos
    I have a question...
    For calculate the Head at the secondary circuit:
    1.- Evalute the pipings circuit from the decoupler???
    2.-How estimate the energy flow at Primary Circuit (inposted by the primary pumps) for evaluate the HEAD at the secadary circuit ???

  • @mohseenaphaniband4740
    @mohseenaphaniband4740 6 ปีที่แล้ว

    First of all thanks for uploading the vedio,The flexible bellow provided after the gate valve for electrical and diesel pump must before the pump connection ,must be same as shown for jockey pump
    The pressure sensing line at the discharge of pump not explain in the vedio , what about the strainer at the inlet of the pump .

  • @MrMute-md6gy
    @MrMute-md6gy 5 ปีที่แล้ว +1

    Thanks for priceless information you provided

  • @TayyabKhalil
    @TayyabKhalil 7 ปีที่แล้ว

    Very informative. Thank you for taking out your time to make and upload this video.

  • @premvigneshappiya9583
    @premvigneshappiya9583 5 ปีที่แล้ว

    Hi, The video is very informative and good. Could you please explain on Electrical panel connection and Pressure details on various pump.. Thank you..

  • @jagsingh8324
    @jagsingh8324 ปีที่แล้ว

    Very informative, good content

  • @hamedfaiz5992
    @hamedfaiz5992 6 ปีที่แล้ว

    Explain is good.. But I have one doubt how did working electrical to mechanical power ,so i ask you explain to electrical and panel board side..how automatically running ,used any sensor.?

  • @hlamoe935
    @hlamoe935 6 ปีที่แล้ว +3

    Installation shown here are not up to NFPA 20 Standard, suction distance not proper, eccentric reducer mounting wrong and OS & Y GATE Valve has no temper switch.

    • @Highlights_football_cricket
      @Highlights_football_cricket 5 ปีที่แล้ว

      Can you please tell me about distance and the detaila which we need to take while installing a pump

    • @allangascon8242
      @allangascon8242 5 ปีที่แล้ว

      Correction,tamper switch sir not temper switch

  • @nayeemhussain8121
    @nayeemhussain8121 3 ปีที่แล้ว +1

    Hi sir, my name is nayeem, and just want to know any design vacancy in fire protection system,
    I have 4 years of experience in fire fighting and fire alarm system...
    Thank you

  • @madhusudhanbt935
    @madhusudhanbt935 7 ปีที่แล้ว +1

    It's a nice info, may I know if it is a real fire electrical operated pump or DG operated pumps only supply water to sprinklers or hydrent system. On that time jockey pump stop working(because jockey pump is only to maintain pressure in the respected network)

    • @afreenali
      @afreenali  7 ปีที่แล้ว

      yes sure: real fire electrical operated pump and Digital fully Automatic Water Pump Control by BMS system..Thanks

    • @madhusudhanbt935
      @madhusudhanbt935 7 ปีที่แล้ว

      afreen ali Sorry I mean to ask Jockey pump is for only to maintain pressure not to supply water continuously while using hydrants for continuous firefighting

    • @afreenali
      @afreenali  7 ปีที่แล้ว +1

      Brother Jockey pump maintain pressure not to supply water continuously only in case of leakage because Pump only 25 GPM and main Pump 500 GPM . Jockey pump can not be pump in high grade pressure in the system. Thanks

    • @madhusudhanbt935
      @madhusudhanbt935 7 ปีที่แล้ว

      afreen ali thank you brother for ur clarification. Now I got my ans

    • @afreenali
      @afreenali  7 ปีที่แล้ว

      welcome

  • @laphilong2860
    @laphilong2860 5 ปีที่แล้ว

    Hi Friend, Please Show me, I think the center line plant off Tee and horizontal split-case Pump shaft should not be parallel. is it right??

  • @food4u598
    @food4u598 5 ปีที่แล้ว

    which schedule standard pipe is used for this? what materials is used ? why they all in red color ?

  • @Johnwick-dt9vx
    @Johnwick-dt9vx 4 ปีที่แล้ว

    Are UL listed check valves necessary requirement or non UL listed check valves can be used?

  • @ambaisi
    @ambaisi 4 ปีที่แล้ว +2

    Is 1/2 inch pipe sufficient for the supply of diesel from the tank to pump?

    • @afreenali
      @afreenali  4 ปีที่แล้ว +1

      Yes sure good

    • @ambaisi
      @ambaisi 4 ปีที่แล้ว

      @@afreenali Thanks a lot.

  • @balansvanas4605
    @balansvanas4605 7 ปีที่แล้ว +7

    ECCENTRIC REDUCTION ASSEMBLY INCORRECT

    • @GrimThe21
      @GrimThe21 5 ปีที่แล้ว

      NO IT IS NOT.. You have to realise that water soarce is supplied from above the suction centreline so it must be flat down... Supply from below suction centre line flat ontop.

    • @ChristianGuco
      @ChristianGuco 4 ปีที่แล้ว

      @@GrimThe21 Yup its a positive suction, but installing eccentric like that is bad practice

    • @leonardlim4838
      @leonardlim4838 3 ปีที่แล้ว

      @@ChristianGuco sir what is the correct position of escentric reducer?thank you

  • @allankusumah2794
    @allankusumah2794 6 ปีที่แล้ว

    the flexible is useless if you install far form pump and between the fix support what for is useless. and the excentric reducer installation is reverse that can use air trap is suction pipe and can cause cavitation at pump. the maintenance space for both engine and fire pump is not good. the battery position in front of fire pump control panel how come.

  • @sruthijeril8026
    @sruthijeril8026 4 ปีที่แล้ว

    Can you make on video on
    1) fire diesel parts and it function
    2) fire pump inside parts and functio

  • @jiromartinez3301
    @jiromartinez3301 5 ปีที่แล้ว

    Eccentric will be on the suction side and concentric will be on The discharge side

  • @muhammadnouman519
    @muhammadnouman519 2 ปีที่แล้ว

    Where is Y strainer to every pump in suction line?

  • @simpledesign5305
    @simpledesign5305 3 ปีที่แล้ว

    Great.. Thanks for this

  • @SAFETYMGMTSTUDY
    @SAFETYMGMTSTUDY 6 ปีที่แล้ว

    Nice video sir

  • @AliRaza-cn7qw
    @AliRaza-cn7qw 5 ปีที่แล้ว

    Salam
    Bhai ap ki video thyk but agr English main explain ni ho rhi to Kia zarorat ha English main smjhany ki Hindi main smjha dety achi smjh a jati

  • @kunalkamble3540
    @kunalkamble3540 2 ปีที่แล้ว

    Sir,
    Why in Dubai indian experience is not considerared.

  • @jaipur3808
    @jaipur3808 4 ปีที่แล้ว

    Why bypass is provided after Discharge Point in Diesel Tank ?..and that also went back to main storage tank why??

  •  7 ปีที่แล้ว +1

    Chuyên g/c và Lắp đặt: INOX- CẤU KIỆN THÉP- HỢP KIM NHÔM CN:" BỒN CN- BỒN ÁP LỰC- BỒN GIA NHIỆT- BỒN CHỨA THỰC PHẨM- SILO- ỐNG CN- ỐNG VI SINH- ỐNG THỰC PHẨM- BỒN &ỐNG GAS CN- BỒN KHUẤY CN": 0974060068( Mr Hoàn)

  • @dsmehndi5813
    @dsmehndi5813 4 ปีที่แล้ว

    Will u plz tell me in a single fire room. How many types of pumps are needed to assemble process

  • @chetan1972
    @chetan1972 7 ปีที่แล้ว +1

    Why sprinkler pump was not installed in the pump room?

  • @Ansari29
    @Ansari29 3 ปีที่แล้ว

    Nice Video 👍

  • @YaseenKhan-pe3qj
    @YaseenKhan-pe3qj 6 ปีที่แล้ว +1

    suction pipe minimum length from pump flange to fitting shall 0 times of pipe dia

  • @br01engineeronwheels
    @br01engineeronwheels 2 ปีที่แล้ว

    What's the responsibility of Pump technician ?

  • @ShoebKhan-mb9tc
    @ShoebKhan-mb9tc 6 ปีที่แล้ว

    Why there is no strainer before pump inlet?

  • @silent9566
    @silent9566 6 ปีที่แล้ว

    what is the black thing in the diesel pump?

  • @asgarfarooque6802
    @asgarfarooque6802 ปีที่แล้ว

    Achcha after installing all the recommendation given by the fire brigade and achieving their certificate and just after achieving the certificate in a month or 2 fire happens in that building who is responsible

  • @shafiqrehman7436
    @shafiqrehman7436 5 ปีที่แล้ว

    Respected sir,
    have you any inspection layout OF ELECTRIC FIRE PUMP ? Reply

  • @shaikkareem1142
    @shaikkareem1142 5 ปีที่แล้ว

    Hi, sir u r vdos is good but in hind tips ok u have mor vdos please give me ok and thanks

  • @danish2zia
    @danish2zia 6 ปีที่แล้ว

    Can you please share electrical termination details of diesel pump and electric pump

  • @karemasamuel1330
    @karemasamuel1330 7 ปีที่แล้ว +1

    very good

  • @vinaygoel859
    @vinaygoel859 5 ปีที่แล้ว

    HELLO SIR
    good morning sir
    what is the minimum pressure in pipe according to chart please explain it

  • @metropcsspringvalley2102
    @metropcsspringvalley2102 6 ปีที่แล้ว

    The small pump isn't chipping out i think it's the check valve but it was recently changed

  • @stalinmarmatas7428
    @stalinmarmatas7428 7 ปีที่แล้ว +1

    With out a tamper switch for each gate valve for monitoring?

  • @beltranfloresflores2408
    @beltranfloresflores2408 4 ปีที่แล้ว

    Mejorar la toma, la succión en desorden

  • @Praveen271
    @Praveen271 4 ปีที่แล้ว

    Good one bro..!!

  • @ahammadhusen9932
    @ahammadhusen9932 6 ปีที่แล้ว

    Sir please upload video of cooling tower and its pipe layout with valve.

    • @afreenali
      @afreenali  6 ปีที่แล้ว

      shortest time in this week thats why i cannot make video in this week hope i will make soon i noted for you Thanks

  • @TheNetcubus
    @TheNetcubus 7 ปีที่แล้ว +1

    nice work my friend , it would be nice if u provided some tech details . thank you

    • @afreenali
      @afreenali  7 ปีที่แล้ว +1

      thanks soon i am working in detail drawing i will upload soon Thanks☺

    • @afreenali
      @afreenali  7 ปีที่แล้ว

      th-cam.com/video/iIDspuse0Jc/w-d-xo.html

    • @afreenali
      @afreenali  7 ปีที่แล้ว

      th-cam.com/video/90T7pGKk1mc/w-d-xo.html

  • @mohammadshojib2927
    @mohammadshojib2927 5 ปีที่แล้ว

    No Supervised system found for gate valve.

  • @shaikgm8084
    @shaikgm8084 5 ปีที่แล้ว

    sir... i want connections from diesel tank to diesel pump
    please tell me how to connect this one,how many inch pump using in this connection....please give me replay

    • @allangascon8242
      @allangascon8242 5 ปีที่แล้ว

      In diesel pump you can see the two black hose pipe with a tag for the supply and return connection.never to use a gate valve in the return piping line.

  • @saadkadu3835
    @saadkadu3835 6 ปีที่แล้ว

    Plz upload video on working of Deluge valve

    • @afreenali
      @afreenali  6 ปีที่แล้ว

      Deluge Valve is known as a system control valve in a deluge system, used for fast application of water in a spray system. Deluge valve protects areas such as power transformer installation, storage tank, conveyor protection and other industrial application etc

  • @angelosalinas4057
    @angelosalinas4057 2 ปีที่แล้ว

    What is that?

  • @gowthamansairam5841
    @gowthamansairam5841 2 ปีที่แล้ว

    Where is the main raiser.......

  • @leventkuzay5983
    @leventkuzay5983 5 ปีที่แล้ว

    min. 10XDia. straight pipe should be installed in order to avoid turblent flow in suction side of the pump.

  • @TheCrustyFry
    @TheCrustyFry 5 ปีที่แล้ว +1

    You need to flip the eccentric reducer upside down.

  • @khadeershaikh1418
    @khadeershaikh1418 7 ปีที่แล้ว +4

    please tell me pressure maintained at jockey and electric pump

    • @afreenali
      @afreenali  7 ปีที่แล้ว +2

      th-cam.com/video/90T7pGKk1mc/w-d-xo.html

  • @msajjadalimsajjadali6742
    @msajjadalimsajjadali6742 6 ปีที่แล้ว

    good job

  • @Hvacian
    @Hvacian 7 ปีที่แล้ว +2

    horrible voice ..not cleared ..your video is good ..but what are you saying ..?

    • @Fakhrealammm
      @Fakhrealammm 6 ปีที่แล้ว

      have you payed him for the video?

  • @fahadelambilacheri6120
    @fahadelambilacheri6120 7 ปีที่แล้ว +1

    I AM 5 YEAR EXPERIENCE I FIRE FIGHTING ENGINEER ANY GOOD OPRTUNITY

    • @nahidhassan8500
      @nahidhassan8500 6 ปีที่แล้ว

      Fahad Elambilacheri add me in what's app - +8801811900607

  • @debashisdas3598
    @debashisdas3598 6 ปีที่แล้ว +1

    Improve your voice and you are only showing the parts without explaining their functions and how do they work. Don't just post any video randomly without any preparation. I don't mean to hurt you, but please check these points so as to improve yourself

    • @afreenali
      @afreenali  6 ปีที่แล้ว

      OK------group link chat.whatsapp.com/InDSuQrqStPED1lVYlhQ7k

  • @advantureindia951
    @advantureindia951 5 ปีที่แล้ว

    Khana khake boliye sir kuch sunai nahin deta...😜😜😜😀😀😀😃😀

  • @ramalingeswararaobhavaraju5813
    @ramalingeswararaobhavaraju5813 3 ปีที่แล้ว

    Thank sir.

  • @nadimakhtar711
    @nadimakhtar711 6 ปีที่แล้ว +2

    Useful for me.

  • @forexlearnpro2264
    @forexlearnpro2264 6 ปีที่แล้ว +1

    Mery pyary bahi pls ap hindi ya urdu me video banao pls

    • @afreenali
      @afreenali  6 ปีที่แล้ว

      bhai Hindi mai b video hai ..check in my channel

    • @namiramariamhayath6858
      @namiramariamhayath6858 6 ปีที่แล้ว

      Boss, where's the strainer in the inlet, no identification or tagging, not told about working of different pumps, where is pressure switch? Sensing line? Only gate valve????

  • @jitbiswajit7336
    @jitbiswajit7336 3 ปีที่แล้ว

    Very poor presentation.Must start from pump foundation and then proceed from there.

  • @rajibnandi7989
    @rajibnandi7989 7 ปีที่แล้ว +1

    can u help about fire fighting technicians. we have company here in dubai?

    • @afreenali
      @afreenali  7 ปีที่แล้ว

      th-cam.com/video/iIDspuse0Jc/w-d-xo.html

    • @afreenali
      @afreenali  7 ปีที่แล้ว

      th-cam.com/video/90T7pGKk1mc/w-d-xo.html

    • @oluyemiakande5626
      @oluyemiakande5626 7 ปีที่แล้ว +2

      am a good technician,
      i know fire works and domestic plumbing

    • @naveend1373
      @naveend1373 7 ปีที่แล้ว

      Oluyemi Akande .msg me 9963792657 Naveen India

    • @rajibnandi7989
      @rajibnandi7989 7 ปีที่แล้ว

      just text me by whatsapp +971566279462

  • @user-lh7iv5gs2c
    @user-lh7iv5gs2c 3 ปีที่แล้ว

    انا فني تركيب مضخات في طرق اسهل من كده بكتير

  • @erwincallao9018
    @erwincallao9018 6 ปีที่แล้ว

    Your flexible is not listed.

  • @MDKHAN-nh5vg
    @MDKHAN-nh5vg 3 ปีที่แล้ว

    Not installed as per NFPA

  • @mohammedsafeer2725
    @mohammedsafeer2725 6 ปีที่แล้ว

    your installation of reducer at pump suction flange is wrong

    • @zealotleader5203
      @zealotleader5203 5 ปีที่แล้ว

      I think , if the source of water supply is above the pump , the flat side of eccentric reducer should be down.. what you say ?

  • @muhammaduzairmukhtar
    @muhammaduzairmukhtar 7 ปีที่แล้ว +1

    Dear Afreen are you work in KSA?

    • @afreenali
      @afreenali  7 ปีที่แล้ว

      Yes Dear

    • @muhammaduzairmukhtar
      @muhammaduzairmukhtar 7 ปีที่แล้ว

      AfreenAli
      In which city, Can you please give me your mobile no

    • @afreenali
      @afreenali  7 ปีที่แล้ว

      I m on vacation in will back after one month

  • @Pelusacollective
    @Pelusacollective 6 ปีที่แล้ว +1

    mumble mumble jumble ok ok .... let me guess he works in Dubai

  • @paradoxlearningpoint4296
    @paradoxlearningpoint4296 3 ปีที่แล้ว

    apni english bolte somossa hole banglai bolen, kotha sposto hoini apnar

  • @nasrinaktar7298
    @nasrinaktar7298 3 ปีที่แล้ว

    i no this work

  • @rajeshgummula3479
    @rajeshgummula3479 7 ปีที่แล้ว

    nice bro i like

  • @iqbalkhan1640
    @iqbalkhan1640 5 ปีที่แล้ว

    Awesome sir bt voice problem

  • @muratakay3499
    @muratakay3499 7 ปีที่แล้ว +1

    there are unnecesary equipments. Suction side have extra unnecessary valve and rubber compensator::::)))))

    • @afreenali
      @afreenali  7 ปีที่แล้ว

      this is as per NFPA installation..thanks

    • @afreenali
      @afreenali  7 ปีที่แล้ว

      th-cam.com/video/iIDspuse0Jc/w-d-xo.html

    • @afreenali
      @afreenali  7 ปีที่แล้ว

      th-cam.com/video/90T7pGKk1mc/w-d-xo.html

    • @mohammedkirmanisyed7960
      @mohammedkirmanisyed7960 6 ปีที่แล้ว +1

      Not at all NFPA 20 installation's followed....suction side reducer is eccentric....but installed incorrectly. ..the taper side should be bottom not on top side...and many more...

  • @LatheWar
    @LatheWar 5 ปีที่แล้ว +1

    Sir hindi me batao ye

  • @ibrahiminayat505
    @ibrahiminayat505 4 ปีที่แล้ว

    jab enghlis nahe aaty tu q bat karta ha

  • @usmannomi4626
    @usmannomi4626 5 หลายเดือนก่อน

    Prv Khan ha

  • @mdramjanali44
    @mdramjanali44 5 ปีที่แล้ว

    please translate in bangla/hindi

  • @shahzadkhan-bs7vb
    @shahzadkhan-bs7vb 7 ปีที่แล้ว

    Please tell me in urdu or hindi.

    • @afreenali
      @afreenali  7 ปีที่แล้ว

      as soon i will make

  • @husseinbindhafer3840
    @husseinbindhafer3840 5 ปีที่แล้ว

    i cant hear you clearly what the explanation is

  • @joshfreak0007
    @joshfreak0007 7 ปีที่แล้ว +2

    Speak louder dude

    • @afreenali
      @afreenali  7 ปีที่แล้ว +1

      next time i have to try my level best .Thanks

    • @afreenali
      @afreenali  7 ปีที่แล้ว

      th-cam.com/video/iIDspuse0Jc/w-d-xo.html

    • @afreenali
      @afreenali  7 ปีที่แล้ว +1

      th-cam.com/video/90T7pGKk1mc/w-d-xo.html

  • @niazafridi3651
    @niazafridi3651 10 หลายเดือนก่อน

    Rubbish sound volume

  • @Antindev
    @Antindev 5 ปีที่แล้ว

    Speak to good voice.. Not good u r voice.
    I can't able to understand...

  • @Sanjayjhaofficial962
    @Sanjayjhaofficial962 6 ปีที่แล้ว

    G

  • @farrukhmehmood679
    @farrukhmehmood679 5 ปีที่แล้ว

    Sir hindi urdu main b btya krin please

  • @KMA835
    @KMA835 6 ปีที่แล้ว +1

    i can't hear you bro

  • @syedzubairali5269
    @syedzubairali5269 7 ปีที่แล้ว +1

    hi bro

  • @jiromartinez3301
    @jiromartinez3301 5 ปีที่แล้ว

    Eccentric reducer position is wrong

  • @ivanivanov7671
    @ivanivanov7671 5 ปีที่แล้ว

    Totally wrong assembly. This won’t be accepted by any assurance company.

  • @mohammedsamimukarram2270
    @mohammedsamimukarram2270 7 ปีที่แล้ว

    wtf dude

    • @afreenali
      @afreenali  7 ปีที่แล้ว

      th-cam.com/video/iIDspuse0Jc/w-d-xo.html

    • @afreenali
      @afreenali  7 ปีที่แล้ว

      th-cam.com/video/90T7pGKk1mc/w-d-xo.html