RO Flow Restrictor value calculation

แชร์
ฝัง
  • เผยแพร่เมื่อ 28 พ.ย. 2024

ความคิดเห็น • 291

  • @ROMTHIRTY
    @ROMTHIRTY 3 ปีที่แล้ว +3

    Just replaced all my RO filters and I kept hearing constant water being wasted at an incredibly high rate. I found a tiny flow restrictive in my line, maybe the previous filter didn’t need much pressure so it worked before? But your video just helped me determine the importance of having a flow restrictor. I just ordered one based on your calculations. Thank you and I’m confident this will fix my problems.

    • @DIY_ZINDAGI
      @DIY_ZINDAGI 2 ปีที่แล้ว

      I replaced all my filters but now water I m having tds of RO water is same as tds of tap water. What should I do?? Is sv not working or fr is not working??

  • @veer1556
    @veer1556 3 ปีที่แล้ว +1

    Sab golmaal, kya master banega re tu 😂😂

  • @Mukeshmiktecrep
    @Mukeshmiktecrep 7 ปีที่แล้ว +42

    Everything you said is wrong, Flow restrictor is used to restrict the water flow to create pressure on the membrane so that pressured water molecules can pass through the membrane pores, without the Flow restrictor the water just pass over the membrane and go to drain side and you will not get pure water.

    • @do-rightsolar6455
      @do-rightsolar6455 6 ปีที่แล้ว

      What pressure does it create at the membrane? Does it depend on which restrictor one uses? Is the flow restrictor just a skinny tube on the inside? Thanks!

    • @devawratvidhate9093
      @devawratvidhate9093 6 ปีที่แล้ว +1

      What is right calculation for flow restrictor

    • @gregoriperalmannn
      @gregoriperalmannn 4 ปีที่แล้ว

      VALIDPOINT!

    • @ArunShankartheRealOne
      @ArunShankartheRealOne 4 ปีที่แล้ว +1

      Not everything, his calculation is correct, but the reasoning is wrong. Using Lowe value flow restrictor would increase water wastage.
      Let's assume the inlet water has a pump of 700 ppm, the wastage water's ppm coming out of the ro membrane might be 800 approx when 350 FR restrictor is used, when using 450 FR it would be around 900+. So using the wrong Flow restrictor would increase water wastage.

    • @bganguly100
      @bganguly100 4 ปีที่แล้ว +1

      @@ArunShankartheRealOne Sirji I think you told the correct reason but got I confused a bit on your example... Please note that you have mentioned 350 FR would result 800 wastage and 450 would result 900+. Here you are telling that if we increase from 350 to 450 then the wastage would be more? i mean from 800 to 900+?
      I am sorry to point this but doing it just to clear my confusion. Please don't mind, its not to proof you wrong, but to clarify my understanding

  • @someoyou
    @someoyou 7 ปีที่แล้ว +5

    I do service for many RO residential systems in my city, most of them have 420ml flow restrictor and 75G memranes, TDS of input water is usually 350 to 500ppm and everything works fine, memranes last for about 3-4 years sometimes more. Usually I try to change the restrictor when changin 75 to 50G membrane and so on.
    Klaudio Berger very useful tips, thnx!

    • @reviewmaza
      @reviewmaza  7 ปีที่แล้ว

      +Oleg Reshetov . Thanks 4 ur valuable feedback

    • @naveenssps
      @naveenssps 7 ปีที่แล้ว

      Oleg Reshetov Is it compulsory to change the flow restrictor when we change the RO membrane, if so why?

    • @someoyou
      @someoyou 7 ปีที่แล้ว

      you better change flow restrictor if you replace 50gal membrane with 100 or 125gal membrane. When change 50 to 75 I dont change restrictor.

    • @reviewmaza
      @reviewmaza  7 ปีที่แล้ว +1

      Thankyou for your valuable feedback... 😁

    • @relevation
      @relevation 6 ปีที่แล้ว

      Hi can i ask you something. My ro doesnt generate waste water at all...Nothing comes out of the drain tube. May i know whats wrong with it?

  • @Swanicorn
    @Swanicorn 4 ปีที่แล้ว +8

    If FR value is higher, 450 compared to 800, then that means 800 is more restrictive than 450. I think such a conclusion should have been mentioned in the video.
    800 FR is allowing more water to go through the membrane and less water is wasted via blue drain pipe. 450 will waste more water compared to 800. Higher FR value should reduce the life of the membrane IMO since it causes more water to pass through the membrane. More water passing through membrane means more wear and tear or higher possibility of membrane blockage which means lesser lifetime of the membrane.

    • @mdfaisal216
      @mdfaisal216 2 ปีที่แล้ว

      No wrong ....fr blocks drain pipe ...if used 300 fr then water wastage would be less but system will work in high pressure ....more water will go through the membrane

    • @Swanicorn
      @Swanicorn 2 ปีที่แล้ว

      @@mdfaisal216 I replied to you with a blog post that did all the calculations. It got deleted because it was a website link. You can google it yourself if you want.
      In short let me explain: The FR number means how much it will restrict the flow of rejected water. Higher value means it will force more water through the membrane.
      A 75 to 100 GPD RO membrane should use 800 FR. Less GPD membranes should use lesser value FR.
      Higher FR value means more water will be purified and less will be drained. So FR800 drains less water than FR450.

    • @Swanicorn
      @Swanicorn 2 ปีที่แล้ว

      @@mdfaisal216 Whatever I said is mentioned on the supplier/manufacturers website. They have a table for what value FR to use for how much GPD membrane.

    • @patricpdp7380
      @patricpdp7380 ปีที่แล้ว

      I just tried joining 2 FR of 450 in parallel and series both but did not make any difference. I noticed same amount of drain water and pure water coming out.

  • @Mukeshmiktecrep
    @Mukeshmiktecrep 7 ปีที่แล้ว +23

    The Flow restrictor is added to the drain side not to the inlet side, the gasket seal is expanded automatically by the Booster pump pressure at inlet side...........
    I am sure you don't know anything how it works.

    • @rabimahapatra8687
      @rabimahapatra8687 7 ปีที่แล้ว +2

      MikTecRep ; Dude, I very much agree with you...

    • @sanjeev45087
      @sanjeev45087 6 ปีที่แล้ว +4

      english me agar अटक रहे हो तो हिन्दी मे talk kar lo sir,, सभी को जल्दि ओर सही समझ मे आयेगा

    • @gregoriperalmannn
      @gregoriperalmannn 4 ปีที่แล้ว +1

      MIKTECREP....YUP......I HAVE TO FORGET ALL INFO I LEARNED FROM THE VIDOE NOW

  • @Mukeshmiktecrep
    @Mukeshmiktecrep 7 ปีที่แล้ว +5

    Flow restrictor is not calculated only the membrane, it also depends on the water pressure, TDS of inlet water.

  • @bharathiarunachalam1949
    @bharathiarunachalam1949 ปีที่แล้ว

    Thank you
    For 80 and 100 gpd membrane
    If I add again one more 300 FR after 450 it be comes 750 FR..
    Will it work or damage membrane life.
    Can you give your suggestions.
    Am waiting for you Mr

  • @bhaskarscollection9894
    @bhaskarscollection9894 2 ปีที่แล้ว

    Hi bro, Thank you for this video. I replaced a FR450 with a new one of same value which came alongwith new RO membrane. But I noticed a lot of water going waste and usable water flow was very low. When I connected the old FR alongwith new one in series, I am getting normal flow of usable and waste water. Is it that the new FR is defective or any fault other than FR?

  • @ROWaterSupports
    @ROWaterSupports 4 ปีที่แล้ว

    Yes Sir. You say 100% right.

  • @Peter-kt5rr
    @Peter-kt5rr 4 ปีที่แล้ว +2

    Thank you for taking time to this video. It helped me determine the correct size for my 100GPD unit.

    • @darrinhawkey8913
      @darrinhawkey8913 3 ปีที่แล้ว

      ?? what one was it ?

    • @Peter-kt5rr
      @Peter-kt5rr 3 ปีที่แล้ว

      @@darrinhawkey8913 the Flow Restrictor video for RO Units

  • @SadanandaUTube
    @SadanandaUTube 7 ปีที่แล้ว +1

    Thanks for your good information about relation of Membrane with flow restrictor

    • @reviewmaza
      @reviewmaza  7 ปีที่แล้ว

      +Sadananda Dey welcome bro

  • @tarkanmercan9918
    @tarkanmercan9918 2 ปีที่แล้ว

    Sir . my I use 75 gp membrane and tds is 300 normallya.. Which flow can I use? I use 300 now... What is your opinion? (My pressure is 4 bar and I dont use pomp machine)

  • @bganguly100
    @bganguly100 4 ปีที่แล้ว

    I have a confusion here... I have checked and found that 600 is the highest value of the flow restrictor available on amazon.... that means it is again not suitable with 80 GPD membrane. so what is the alternative

  • @varunsardana2700
    @varunsardana2700 6 ปีที่แล้ว +1

    awesome....thats a scientific answer......really impressed.....

  • @siddiquihomeopathy422
    @siddiquihomeopathy422 3 ปีที่แล้ว

    i have used 100 gpd membrain but fr 300 is it good ?

  • @VijaySingh-ic5px
    @VijaySingh-ic5px 5 ปีที่แล้ว +1

    100 gpd membrane n 100 gpd pump me kon sa flowsictor lagana chahiye.. 450 ya 550

  • @vinothkannan4572
    @vinothkannan4572 7 ปีที่แล้ว

    my bnqs bump not able to generate as they membrane require pressure can i use under value flow resistrictor for create pressure for manually because you told ur videos bnqs bump is the best............

  • @bramhagyani5018
    @bramhagyani5018 2 ปีที่แล้ว +1

    Flow restrictor is not for to expand o ring, it is meant for back pressure generation.

  • @georgechristepher2118
    @georgechristepher2118 5 ปีที่แล้ว

    Which shop will we get FR and Y connector

  • @shancochin2010
    @shancochin2010 7 ปีที่แล้ว

    super macha.Where did you study all this? what about 0.38 factor coming into these calculations?

    • @reviewmaza
      @reviewmaza  7 ปีที่แล้ว

      Hi.. I read it in some Membrane manufacturers Website.. I dnt remember it.. but its correct for shure...

    • @reviewmaza
      @reviewmaza  7 ปีที่แล้ว

      goo.gl/2EWch8

  • @rajeshnanecha
    @rajeshnanecha 6 ปีที่แล้ว

    I am using 75 gpd membrane and flow restrictor is 450. Now I want to add 80 gpd membrane in my ro filter should I change ro flow restrictor ? If yes then pl. suggest.

    • @reviewmaza
      @reviewmaza  6 ปีที่แล้ว

      Yes you mus use new fr for new membrane

  • @shardaarvind123
    @shardaarvind123 7 ปีที่แล้ว

    Hi, I have Kent RO water filter. When I remove wire from FRT , water is coming out from rejected water pipe. But when I add FRT then rejected water is not coming out. Can you suggest what can be the problem.

    • @reviewmaza
      @reviewmaza  7 ปีที่แล้ว

      +Arvind Sharda replace the FR

  • @TheRj_007
    @TheRj_007 2 ปีที่แล้ว

    bhai 80 gpd membrane or pump h or tds 800 h ot konsa fr lagaye

  • @TheExcessivemhz
    @TheExcessivemhz 5 ปีที่แล้ว +1

    Thanks for the video! Could you please help: my RO filter doesn't produce Waste Water at all! Is it normal ? Or something is wrong ?

    • @raam1702
      @raam1702 4 ปีที่แล้ว +1

      There is a problem in ro candle and check the flow restrictor(pressure valve)

  • @sundarjaya7244
    @sundarjaya7244 3 ปีที่แล้ว

    When doing FR calculation it is not properly focused and you can use sketch pen instead of using light color. I am unable to catch perfectly.

  • @RUSHI251
    @RUSHI251 5 ปีที่แล้ว

    For 80 gpd membrane which FR used ?

  • @prashantdubey998
    @prashantdubey998 7 ปีที่แล้ว +1

    hey bro nice vedio... really helpful... I have ro purifier and I have replace the ro membrane last month and it's working properly... but from last two three days the output filtered water is coming at a very low speed.. it takes about 12 to 13 hrs to filter 12 ltr of water and waste water is so much... pls help me out to solve the problem... ro membrane is csm 75 gpd ... help me out... pls

    • @reviewmaza
      @reviewmaza  7 ปีที่แล้ว

      +prashant dubey did you also replaced the flow restrictor?

  • @prafullsabat
    @prafullsabat 7 ปีที่แล้ว

    My kent Supreme has a factory fitted Flow Restrictor of Rating 300, and it says capacity of 15L/hr, iam in process of changing the Membrane to 75gpd which flow restricor should i use ideally ?

    • @reviewmaza
      @reviewmaza  7 ปีที่แล้ว

      FR 450

    • @reviewmaza
      @reviewmaza  7 ปีที่แล้ว

      75 GPD SHALL GIVE YOU 10 TO 12 LITER. BETTER GO FOR 80GPD. WITH FR 450

    • @mohammadgulab2728
      @mohammadgulab2728 3 ปีที่แล้ว

      @@reviewmaza but you said for 75 GPD membranes we must use FR 800

  • @ramborums
    @ramborums 5 ปีที่แล้ว

    I get good flow from the pure outlet but almost no flow from the reject line. Could the restrictor be clogged? What can i do? Thanks

    • @reviewmaza
      @reviewmaza  5 ปีที่แล้ว

      Yes. change the FR

  • @dipuxu
    @dipuxu 5 ปีที่แล้ว +1

    i use 450 for 80 gpd. If i use 500 or 800 FR is possible that output of flow increasing.

  • @subhashsaini7755
    @subhashsaini7755 7 ปีที่แล้ว

    Sir, 75gpd membrane ke liye FRT konsa use kre

  • @MrSayog
    @MrSayog 6 ปีที่แล้ว

    Bhai mere kent prime Ro ki membrane ki out let pipe se drop drop krke water aata he kya wo block ho gyee hein inlet pipe se full pressure ja raha hein carbon filter ka baad I checked just Ro memebrane

  • @atulchauhan3931
    @atulchauhan3931 6 ปีที่แล้ว

    What post carbon does and how it is different from mineral cartridge?????

  • @damusscone4373
    @damusscone4373 7 ปีที่แล้ว

    is there a need to change a flow restrictor , if yes , when should be change it, after how many days or months

    • @reviewmaza
      @reviewmaza  7 ปีที่แล้ว +1

      Damu Sscone it must be replaced when you replace any inline filter or Membrane

  • @rishitasaini5283
    @rishitasaini5283 4 ปีที่แล้ว +1

    When you make vdo plz price must be tell us.

  • @suseelaballina2952
    @suseelaballina2952 6 ปีที่แล้ว

    Water does not have countnes flow in side the pot after passing through members what is the problem

  • @ABDULAZIZ272
    @ABDULAZIZ272 7 ปีที่แล้ว

    My input water tds is 245. I want to bring it down to below 10 tds not for drinking. Which flow restrictor should I use with 300 gpd ro membrane and 300 gpd booster pump. Please help me.

    • @reviewmaza
      @reviewmaza  7 ปีที่แล้ว

      +Md.Abdul Aziz ok . Pl give ur no

    • @ABDULAZIZ272
      @ABDULAZIZ272 7 ปีที่แล้ว

      Reviewmaza my mobile no. is 9957258567

  • @nileshtikkas9674
    @nileshtikkas9674 5 ปีที่แล้ว

    Sir 100 gpd membrane ko konsa FR lagana chahiye. Aur 300gpd membrane ko konsa FR lagana chahiye. Plz tell me

    • @krish2542
      @krish2542 4 ปีที่แล้ว

      It depends on motor output value. By the way, 100gpd RO system (domestic) and 300gpd RO system (commercial) use different sized pipes, connectors, etc.

  • @bishwajeetmahato9924
    @bishwajeetmahato9924 7 ปีที่แล้ว

    my actual water tds is 400 which member should i use for better result, i need 50 tds

  • @biswajitbhattacharyya9217
    @biswajitbhattacharyya9217 3 ปีที่แล้ว

    Very good info! Thanks! 👍

    • @reviewmaza
      @reviewmaza  3 ปีที่แล้ว

      Glad it was helpful!

  • @OrangeCandyShorts
    @OrangeCandyShorts 7 ปีที่แล้ว

    sir can we use ro membrane without booster pump ..with high pressure inpit

    • @reviewmaza
      @reviewmaza  7 ปีที่แล้ว +1

      +MOHAMMAD UMAIR no. If pressure is low u cant use ro membrane

    • @OrangeCandyShorts
      @OrangeCandyShorts 7 ปีที่แล้ว

      Reviewmaza :my water pressure is high sir ..sir please make a sall video about without booster pump ro membrane ..please sir

  • @HimanshuSharma-bb7mi
    @HimanshuSharma-bb7mi 4 ปีที่แล้ว

    My membrane is of rating 75 gdp and the water tds is 600 ppm can I use 300 mlm flow restrictor?

  • @karunasagardheram598
    @karunasagardheram598 3 ปีที่แล้ว

    We understand that you have not understood yourself!
    A restrictor results in back pressure, which necessary for RO, which itself needs pressure to pass through a membrane. Please go through the process of reverse osmosis!

  • @davdaamit
    @davdaamit 7 ปีที่แล้ว

    At present in my ro it's 450 fr should i upgrade to 800 fr ? 75gpd membrane is installed before 2 months

    • @davdaamit
      @davdaamit 7 ปีที่แล้ว

      My ro Motor is week as told by installer so do suggest ...

    • @reviewmaza
      @reviewmaza  7 ปีที่แล้ว

      +Amit Davda no.if ur motor is weak then jo h wohi thik h.

  • @MultiBibhudatta
    @MultiBibhudatta 7 ปีที่แล้ว

    i want to buy a tds meter from which brand and from where i will buy?please reply sir

    • @sathishmn5188
      @sathishmn5188 7 ปีที่แล้ว

      HM brand is good for home use

  • @vikiraman8398
    @vikiraman8398 5 ปีที่แล้ว +1

    Super sir you are very kind thank you you share all knowledge about RO system thank you very much

  • @amanmaheshwari2537
    @amanmaheshwari2537 7 ปีที่แล้ว

    mereko 300gpd pump &300 gpd membrane me fr lagana hai kitne value ka lagana hoga

  • @ncertzone2249
    @ncertzone2249 7 ปีที่แล้ว

    Sir plz bataen ki 'nexus' company ka ro filter kaisa rahega for tds between 900 to 1000

    • @reviewmaza
      @reviewmaza  7 ปีที่แล้ว +1

      +anzar ata better go for hitech filters

    • @ncertzone2249
      @ncertzone2249 7 ปีที่แล้ว

      Reviewmaza hitech filter nexus nahi hi?
      agar nahi hi to kon si company ka hitech filter hi plz bataen ?

  • @nantulalbhowmick6302
    @nantulalbhowmick6302 3 ปีที่แล้ว

    Very very very very thanks

  • @sandeepbompally8998
    @sandeepbompally8998 7 ปีที่แล้ว

    what will happens if use 100 gbd membrane for 80gbd pump
    is it creates any problems???

    • @reviewmaza
      @reviewmaza  7 ปีที่แล้ว

      after some days membrane will get weak.
      and also may get damaged

    • @ariseagain3423
      @ariseagain3423 6 ปีที่แล้ว

      Kuch nhi hoga tensn na lo

  • @ParveenKumar-zi6se
    @ParveenKumar-zi6se 6 ปีที่แล้ว

    मेरे घर पर KENT SUPER PLUS 8 Ltr Ro लगा हुआ है। पहले 75 GPD की membrane व FR 550 लगी थी । मैने अब मेम्ब्रेन चेंज कर दी ह जो CSM 50 GPD की है ।क्या अब मुझे FR बदलनी पड़ेगी।

    • @reviewmaza
      @reviewmaza  6 ปีที่แล้ว

      ha.. 300 lagao ..

  • @damusscone4373
    @damusscone4373 8 ปีที่แล้ว +1

    it was very helpful

  • @purushothamnikkam6069
    @purushothamnikkam6069 6 ปีที่แล้ว

    where do u get these spares? also let me know if there is any specific brand?

    • @reviewmaza
      @reviewmaza  6 ปีที่แล้ว

      whatsapp me 7972197566

  • @patelbijal422
    @patelbijal422 5 ปีที่แล้ว

    Sir mera ro dulphine ka hai aur mere ro me pani ka test nahi aarha hai tds bhi 94 hai to aub me kya karu jo muje pani ka test acha mile

  • @vickygpandori5851
    @vickygpandori5851 6 ปีที่แล้ว

    Sir 70 gpd membrane 70gpd pump per kon sa flow e j kter lagana ha

  • @damusscone4373
    @damusscone4373 8 ปีที่แล้ว

    do you think aquadyne ro coponents are good for local ro systems

    • @reviewmaza
      @reviewmaza  8 ปีที่แล้ว

      Damu Sscone dear sir, thanks for the question. aquadyne i suppose if you dont have any option. other wise you can go for good brand names .

    • @damusscone4373
      @damusscone4373 8 ปีที่แล้ว

      i have a mineral ro system 1 year old the taste of water is degraded now. also the rejected water coming out is very low. should i change the entire components including the ro membrane. also suggest some good brands

    • @reviewmaza
      @reviewmaza  7 ปีที่แล้ว

      +Damu Sscone genrally after 1 year you must replace all components.

  • @martinvarkey150
    @martinvarkey150 7 ปีที่แล้ว

    What is the GPD value of Kent grant plus RO filter (concealed one)

    • @reviewmaza
      @reviewmaza  7 ปีที่แล้ว

      +Martin Varkey 80 gpd or 75 gpd

  • @415AS
    @415AS 6 ปีที่แล้ว

    Livpure purfier Tds is less than 10 what should I do there is no tds adjuster.

    • @epc123456
      @epc123456 5 ปีที่แล้ว

      Throw it. Product water TDS should be atleast 200 -250 TDS so that you can get necessary minerals. Very low TDS water is closer to distilled water and gets acidic. Thats why tingling taste which people say its sweter...

  • @Ruthrasivasakthi
    @Ruthrasivasakthi 7 ปีที่แล้ว

    What is the color of drain water. If is white any problem

    • @reviewmaza
      @reviewmaza  7 ปีที่แล้ว

      +Sakthi Vel no problem . Actually in foreign contries blue color is used for pure water and red color is used for reject water. In India we use any color

    • @pavlosm8827
      @pavlosm8827 7 ปีที่แล้ว

      If it's whitish this probably means it's high in TDS

  • @abishekba4149
    @abishekba4149 7 ปีที่แล้ว

    i would like to use an RO to reduce the TDS of tap water for bathing,not for drinking it.Inlet Water TDS is 900 i would like to reduce it to 250 TDS not to 90.i thinking of using 2 or 3 ro membrane in series with booster pump in between the membrane to reduce waste water waste from the normal ratio of 4:1,Can you give any suggestions How can a flow restrictor be used to increase the RO output to get higher TDS upto 250, i don't mind replacing the ro membrane due to premature fouling once in 6 months also.Suggestions

    • @reviewmaza
      @reviewmaza  7 ปีที่แล้ว +1

      th-cam.com/video/KA6_sjjutaA/w-d-xo.html

    • @reviewmaza
      @reviewmaza  7 ปีที่แล้ว

      Pls see the reply video...

  • @puriaa
    @puriaa 7 ปีที่แล้ว

    wud u b so kind enough to post it in hindi, so that all people can understand it . now i have a problem dear. one night the over head tank of ours got emptied and d kent machine installed in our house kept running for 6 hours (without water). from then onward very low water with air is coming out from d tube that ejects rejected water and it takes much much time to fill the container. plz help me out as soon as possible. what might have bn happened and if i call the kent personnel how much will it cost to me . plz let me know.

    • @reviewmaza
      @reviewmaza  7 ปีที่แล้ว

      +jeetendra kumar pallai membrane has been damaged due to low pressure

    • @puriaa
      @puriaa 7 ปีที่แล้ว

      sir thanx a lot for having reciprocated to my message. so what wud d cost i have to incur and is there any other damage caused to the machine

    • @reviewmaza
      @reviewmaza  7 ปีที่แล้ว

      +jeetendra kumar pallai how much old is your machine?

    • @puriaa
      @puriaa 7 ปีที่แล้ว

      Reviewmaza . It's a 9 yr old machine but 1 1/2 YR back everything including d motor was changed.

    • @reviewmaza
      @reviewmaza  7 ปีที่แล้ว

      you will hav to change ro+ inline filters + flow restrictor

  • @sandeepbompally8998
    @sandeepbompally8998 7 ปีที่แล้ว

    can u tell me about the quality of hi-tech company products

  • @deepaksingh-ye1cv
    @deepaksingh-ye1cv 7 ปีที่แล้ว

    Mere philter ki membrin nai h or kuch dino bad wo kam pani filter kr rhi h sb kuch change kraya tha mene lekin pani der s philter kr rhi h ab mene usme 450 ki 2 fr lgai h pani to sai philter horha h but usse koi pareshani to nai hogi n

    • @reviewmaza
      @reviewmaza  7 ปีที่แล้ว

      +deepak singh nai

    • @reviewmaza
      @reviewmaza  7 ปีที่แล้ว

      +deepak singh 300 ke 2 Laga do

  • @abhijeetjanjalkar3569
    @abhijeetjanjalkar3569 6 ปีที่แล้ว

    light green colour inside the pipe of ro why?

  • @subhashchander5572
    @subhashchander5572 4 ปีที่แล้ว

    Very good topic,but audio is not laud n clear.

  • @Mukeshmiktecrep
    @Mukeshmiktecrep 7 ปีที่แล้ว +2

    Wrong: Flow restrictor does not generates pressure RO Pump does.

    • @reviewmaza
      @reviewmaza  7 ปีที่แล้ว +3

      Mukesh flow restrictior restricts flow so generate reverse pressure

    • @collins51070
      @collins51070 6 ปีที่แล้ว

      Miktecrep sir then please tell me how to select the FR against TDS

  • @arsxplr
    @arsxplr 7 ปีที่แล้ว

    i have ro purifier...and waste water not stopped after ro machine switched off...plz tell me the solution ....

    • @reviewmaza
      @reviewmaza  7 ปีที่แล้ว +1

      brother your Solenoid valve has been damaged, please replace it so that problem will be solved.
      buy solenoid valve amazon : amzn.to/2mXcNqH

    • @someoyou
      @someoyou 7 ปีที่แล้ว

      check and replace your 4-way valve if you have one in your system

    • @arsxplr
      @arsxplr 7 ปีที่แล้ว

      thank u for kind reply...it is a problem of SV (solenoid Valve) and solved the problem after replacing the valve.

    • @reviewmaza
      @reviewmaza  7 ปีที่แล้ว

      Happy to help.. Please subscribe our channel .

  • @ankitjangrag8924
    @ankitjangrag8924 4 ปีที่แล้ว

    50 gpd for which quality fr plz tgol

  • @chahatkhanna5276
    @chahatkhanna5276 7 ปีที่แล้ว

    Can flow restrictor be used in opposite direction

    • @reviewmaza
      @reviewmaza  7 ปีที่แล้ว

      +chahat khanna no

  • @WaterXpert
    @WaterXpert 6 ปีที่แล้ว

    In my new RO reject ro continues
    even i changed sv n housing
    still problem continues

  • @ziaulislammamun3795
    @ziaulislammamun3795 4 ปีที่แล้ว

    Can you please explain more how a flow restrictor works and if an RO purifier does have it what will happen? Meaning কি, কি ভাবে কাজ করে, কি জন্য দরকার, না হলে কি সমস্যা ।

    • @babudhi
      @babudhi 4 ปีที่แล้ว +2

      Flow restrictor is used to create pressure on RO membrane. There is one water inlet and 2 outlets(One is for for pure water and other is for waste water) in a RO housing. There is direct flow of water from inlet to outlet. Pure water is taken form membrane from pure water outlet. Now, to extract water through RO membrane requires high pressure. So if we not use flow restrictor, enough pressure will not build up and water will directly pass through outlet. So, by adding flow restrictor pressure build up inside housing and water squeezes through membrane and comes out through pure water outlet. Hope you understand.

  • @villagersvlogs4565
    @villagersvlogs4565 7 ปีที่แล้ว +1

    i watched our most of the videos.now i want to buil ro+uv+tds water purifier at home. where should i get all the components. I am from Pune. Please tell me.

    • @reviewmaza
      @reviewmaza  7 ปีที่แล้ว

      +Ajit Anpat you can get many suppliers from indiamart

    • @villagersvlogs4565
      @villagersvlogs4565 7 ปีที่แล้ว

      Thank You sir...

    • @villagersvlogs4565
      @villagersvlogs4565 7 ปีที่แล้ว +1

      I saw many suppliers on indiamart now i am confused about brands, so suggest me the brands of all parts please. my email id is ajitanpat55@gmail.com

    • @hareshdodiya2658
      @hareshdodiya2658 7 ปีที่แล้ว

      Ajit Anpat for more detail WhatsApp me on 9723477627

  • @YogenderShandilya
    @YogenderShandilya 5 ปีที่แล้ว

    Sir ro का आउटपुट पाइप कितनी ऊचाई
    तक पानी पहुंचा सकता है

  • @lawiez
    @lawiez 6 ปีที่แล้ว

    hello, nice video!
    if i'm running 2 100 gpd membranes in series, ie, waste water from 1st membrane feeds the second, what kind of flow restrictor should i get?

    • @reviewmaza
      @reviewmaza  6 ปีที่แล้ว +1

      Fr 650-850

    • @lawiez
      @lawiez 6 ปีที่แล้ว

      thank you!

    • @ariseagain3423
      @ariseagain3423 6 ปีที่แล้ว

      In series combination system work in 1:1 (clean : waste) you need only 300ccm .
      Calculate if both membrane work 30% recovery then take 100L(litter) and make 30L clean water and 70L waste
      In series that 70 went again in next membrane 21L clean and 49L waste
      So clean water 51L(30+21) and waste only 49L
      Means now system work 51:49
      For your system 250ccm sufficient. So use 300ccm only

    • @reviewmaza
      @reviewmaza  6 ปีที่แล้ว

      actually you are correct to some extent, but the membrane which is prior will get damaged soon, due to clogging. if we do not give 1:4 rejection.

    • @ariseagain3423
      @ariseagain3423 6 ปีที่แล้ว

      I just giving correct fr value for system on the basis of giving information
      Now one more data needed for considering membrane life waste water TDS
      If waste water didn't reached 1000+ TDS system can run with 300fr
      If waste water have more TDS than 1000 then use fr 550 only
      By using fr550 system run on 1:4

  • @shravan4469
    @shravan4469 6 ปีที่แล้ว +1

    Good one Bro...👏👏👍

  • @chingeshkhan5182
    @chingeshkhan5182 7 ปีที่แล้ว

    sir my to water is not sweet my TDS is 1800 to membranes 50 gpd CMS, filter ro with bio cera alkaline cartage 260 TDS but water is not sweet kindly tell me how to increase water sweetnees.i want little hard water.

    • @reviewmaza
      @reviewmaza  7 ปีที่แล้ว

      +chingesh khan 1800 tds is to high . And product water is also high in tds.

    • @chingeshkhan5182
      @chingeshkhan5182 7 ปีที่แล้ว

      Reviewmaza I'm asking you for solution,I knw this already,my tab water is 1800. n ro water is 260 with alkanine cartage,but water is not sweet,n flow of my incoming ro water is dip,so slow, m using csm 50 gpd membrane with 300 fr.

    • @vinothkannan4572
      @vinothkannan4572 7 ปีที่แล้ว

      chenge your high tds ro membrane go with dow filmtech is the best for high tds,,,,,

    • @ariseagain3423
      @ariseagain3423 6 ปีที่แล้ว +1

      Brother use multiple post carbon filter it will make water taste sweet
      And if you want lower TDS water use multiple ro membrane
      100 or 80 gpd membrane 1st and second will be 50gpd in series,
      Re-circulate second membrane product water to pump inlet with main inlet
      You will see your TDS drop and taste improve.
      Membrane life increase

  • @devendrabhattacharya
    @devendrabhattacharya 7 ปีที่แล้ว

    50gpd membrens which FR no can be use

  • @9971439099
    @9971439099 6 ปีที่แล้ว

    Mere ro ka rejected water apne aap bahar aata hai power of hone ke baad bhe ?.

  • @balwantkumar4892
    @balwantkumar4892 6 ปีที่แล้ว

    What is the measurement of .38

  • @MrAnirbanchakrabarty
    @MrAnirbanchakrabarty 6 ปีที่แล้ว

    How much for 300 GPD ro membrane

  • @vijaymareddi4514
    @vijaymareddi4514 4 ปีที่แล้ว

    Sir pls hindi main video banaye ta ki sabko samj Main aye. Kyon ki mostly technicians English jante nahi

  • @rajendarsingh4777
    @rajendarsingh4777 7 ปีที่แล้ว

    how many cost of solenoid valve

    • @reviewmaza
      @reviewmaza  7 ปีที่แล้ว

      Rajendar Singh depends on company

  • @subhashsaini7755
    @subhashsaini7755 7 ปีที่แล้ว +3

    Sir, mere RO membrane me clean water dire dire(बुंद-बुंद)aa rha h & dirty water fast as rha h,sir please problem btao.

    • @mrgoludau4690
      @mrgoludau4690 6 ปีที่แล้ว

      same problam he .....ans. nahi de rahe he sir

    • @sayurmesh7639
      @sayurmesh7639 6 ปีที่แล้ว

      I think your membrane is chocked.
      Replace it

    • @buddhiprakashmeena2481
      @buddhiprakashmeena2481 6 ปีที่แล้ว

      मेम्ब्रेन चेंज कर लो

  • @vidalcharide
    @vidalcharide 6 ปีที่แล้ว

    Thank you. Good help

  • @OrangeCandyShorts
    @OrangeCandyShorts 7 ปีที่แล้ว

    i have uf uv filter ..but i need to ro .

  • @Rajvi14.318
    @Rajvi14.318 7 ปีที่แล้ว

    angreji ki jagah Hindi me vdo banaoge to bahut logo ko phayda hoga, bahut kam log aapke channel ko subscribe karenge, Hindi me bologe to vdo jaldi banegi aur bahut likes bhi milenge

    • @reviewmaza
      @reviewmaza  7 ปีที่แล้ว

      bhai ye to purnana video h.. abi sare naye videos hindi me hi h..

  • @gulishtakhan978
    @gulishtakhan978 6 ปีที่แล้ว +6

    Bhai Bhai saree video Hindi mein banaya karo

  • @sandeepsandy6927
    @sandeepsandy6927 6 ปีที่แล้ว

    Very good sir

  • @vipindhiman7645
    @vipindhiman7645 6 ปีที่แล้ว

    f.r ki jagah nal ki tonti lgaa de aur waste water ki speed slow kar de to Kya nuksan ho jaayga

    • @reviewmaza
      @reviewmaza  6 ปีที่แล้ว

      MEMBRANE BLOCK HO JAYEGA

  • @fareedmd8413
    @fareedmd8413 4 ปีที่แล้ว +1

    100gpd membrane aur100gpd pump

  • @hemantkvlog8400
    @hemantkvlog8400 6 ปีที่แล้ว

    Sir..pura pani bahar nikal rha h store nhi ho rha h kya problem batayiye pls

    • @reviewmaza
      @reviewmaza  6 ปีที่แล้ว

      watsapp me 7972197566

  • @chayanbhowmick3800
    @chayanbhowmick3800 6 ปีที่แล้ว

    Hi sir I am looking for a installation training

  • @shravanghatage1059
    @shravanghatage1059 7 ปีที่แล้ว

    What stands for. 38

    • @reviewmaza
      @reviewmaza  7 ปีที่แล้ว

      it is a value that is used for the calculation.

  • @NeonblueIndustries
    @NeonblueIndustries 7 ปีที่แล้ว

    Back pressure caused by the restrictor FORCES water molecules to be pushed through the membrane. This is bypassed when you want to flush the R/O surface to help it keep clear. This can add extra life of the R/O membrane.

    • @reviewmaza
      @reviewmaza  7 ปีที่แล้ว

      +Neonblue Industries correct

  • @gopikrishna3226
    @gopikrishna3226 4 ปีที่แล้ว

    Book akkda dhorukuthudhi sir

  • @Civilcontra
    @Civilcontra 7 ปีที่แล้ว

    bhai installing kaise kare pipe ki ho bata

  • @awaanawaan7687
    @awaanawaan7687 7 ปีที่แล้ว

    Tnx for information

  • @santoshthorave8859
    @santoshthorave8859 6 ปีที่แล้ว

    F.R Kaise kam karta hai? Q lagana padta hai? please make Hindi video

  • @asankar228
    @asankar228 4 ปีที่แล้ว

    Hi can i have ur number please... My RO output water is very slow and RO takes more time to fill 7 lts... How to increase the flow... Please help

    • @reviewmaza
      @reviewmaza  4 ปีที่แล้ว

      api.whatsapp.com/send?phone=+917972197566

    • @reviewmaza
      @reviewmaza  4 ปีที่แล้ว

      Replace ro membane