300 ml Per Min Flow Restrictor | RO Membrane |Vontron Co. Ltd.| R.K.Aquafresh | RO Water Support |
ฝัง
- เผยแพร่เมื่อ 2 ต.ค. 2024
- RO Membrane choke hone ke kaee karan hote haian-
1- jab aap pre filter housing me lage spun ya 9" candle ko 1500 litre se 3000 litre pani filter karne ke baad samay par change nahi karte haian.
2- Jab aap Achha quality ka inline filters use nahi karte haian.
3- Jab App achchha quality ka membrane tds ke according apne ro system me nahi use karte haian.
4- Jab aap 550 ml per minute wali flow restrictor nahi lagakar 300 ya 450 ml per minute wali koee ghatiya quality kee flow restrictor ka use karte haian.
#RO
#membrane
Aameria 0 to 21 Kg/Cm2 300gpd Bottom Connection Pressure Gauge Meter Stainless Steel-
amzn.to/3al62VQ
Wellon Organic Push Fit Inline Filter Complete Set with Pre Carbon, Sediment, Post Carbon Filters and Connectors for All Water Purifiers and RO Systems 2 Carbon Filter 1 Sediment Filter 6 Elbow-amzn.to/3hbrcII
Wellon 100 GPD RO Booster Pump with Teflon Tape for All Types of Water Purifier - 3 Pcs - amzn.to/3aP8x2I
Hi-Tech RO Booster Pump Head Black for Water Purifier Pump -
amzn.to/3j7F5YO
NECO TECH Cubit 75 GPD RO Low TDS Membrane - amzn.to/3gpdh0f
KENT Supreme Lite 2020 (11110), Wall Mountable, RO + UF + TDS Control, 8 L Tank, White, 15 LPH Water Purifier - amzn.to/3gHpI7G
FLAWISH Replace Remove Tool Kit Plier for Reverse Osmosis Ro Membrane Filter Stainless Steel - amzn.to/3mBHeOP
Mi Smart (MRB13) 7 L RO + UV Water Purifier with App Connectivity and DIY Filter Replacement (White) -amzn.to/32Z1Bhv
PARIJATA Industrial Water Solenoid Valve 12V DC 500mA (1/2"X1/2") for Commercial Water Purifier - 1 Pcs - amzn.to/3ioO2MK
Ionix Ro Booster Pump Head White For Ro Water Purifier Pump, Works with All ro Booster Motors 75 GPD, 100 GPD, ro motor pump head, ro motor pump head parts - amzn.to/3dfUoNe
KEMFLOW 48 VOLTS 100 GPD PUMP WHITE ( MATEL ) - amzn.to/37s3zsK
बहुत ही अच्छे तरीके से आप ने समझाया और वीडियो भी अच्छे से बनाया ताकि समझ आये 🙏🙏🙏🙏🙏👏👏👏
बहुत ही अच्छे तरीके से काम समझाया है। बहुत बहुत धन्यवाद।
Membrane ka do output hai,kayse pata chalega konbala pure water ka aur kon bala reject water ka?
Sir original membran ka pata kese lagai ki original hi ya copy
Tds reading Kitna hone chahiye
Normally 80 to 90
Alkaline k pehle post carbon filter lagaye tho koi nuksaan tho nhi
नहीं, but last में original post carbon filter लगाने में आपको क्या दिक्कत है ?
I like that very good as best friend
Yes, I can feel it...🤝
Memron kitne ka aayega original
Call me all products sell sarvice all pune
To mea mene signent+carbon+ s v pump + tds +memrin ke bad carbon element ko kha lgaye sir jra diagram btana 🙏
Very helpful sir, hamara kent pearl ro system hai.. usme pure water slow aa raha hai aur waste water normal se bhi jyada speed aa raha hai, iska karan kya hoga
Sir TDs controller ke upper ek video banaiye
Aapne jo pump khola hai woh star wala 🪛 kitna number hai
Tds controlar ka canection uf me dena chahiye tha sir
सर जी बहोत बधिया
Membrane kaun si brand ki lagana chahie?
भाई साहब आप का भिडीयो से तो सभी समझ में आ गया लेकिन गंदा पानी यानी वेस्ट पानी नहीं निकल रहा है इस का कारण बतायेंगे तो बहुत बहुत अभारी रहुगा
Flow restrictor या solenoid valve
Ro me New membrane, pri carbon , post carbon & sediment change kar liya hai tank me pani drop drop aaraha hai to kya problem hogi
SV का flow, pump का pressure और ये दोनों अगर सही है तो अंत में membrane ka output check करो...
Great information
Sir maine ek assembled RO 2-3 din k liye use kiya tha uske bad fir 1 sal bad use kiya.. Lekin pani slow aa raha hai...tds v high aa raha hai.. Koi upai bataiye?
Sir ro se khara water aane ka kya karan hai
सरजी आप इतनी मेहनत करके विडिओ बनाते है।तो और 20 से 25 सेकंड का विडिओ बडा बनाकर उसमे फिल्टर के नाम के साथ डायाग्राम बनाकार दिखाये वो भी सब तराह के फिल्टरो के साथ का तो बहुत अच्छा होगा
Wonderful bhai.. Aap to RO ke master hai. Kya aap ahata sakte hai flow me agar air aa rahi hai uska kya reason ho sakta hai..? Kabhi bhi RO running conditions me bhi air ki awaz aati hai ander se.
Flow restrictor की sound आती है।
बोहत अछा तरीका बताया आपने सरजि आपको बोहत बोहत धन्यवाद 🙏🙏
आपको पसंद आया और मुझे बहुत खुशी हुई।
बेहतरीन तारिकेसे जानकारी दी हैं, शुक्रिया सर जी 🙏
Tusi Gareth ho sir
Sar mere mambran ke ak side se Pani aa rha he peor water nhi aa rha he kya Karu
Bro mane ek aqua purifire karida hai uske water Ka tds 700 se jyada aaraha hai aap kuch batao
Nice information sir
Thanks bro
Ro poora bharne ke baad flot se band ho jata hai or thodi der baad bina paani nikale aapne Aap chal parta hai phir band ho jata hai
helpful information for us thnx..sir MLT filtrr ka full form kya hai pls tell us
Sar abhi main Ek a raha hun main disturb and lagaya hai 100 GDP ka Hafte Bhar chalne ke bad pure water Aana Band Ho Gaya booster pump ke aur putland per Pani Rokne se pressure per Hath Nahin rukta Hai anguthe ko fek deta hai to kya Sar uska memoran Chauk Hai
sir ji neo company ki ro me westege pani slow arahahe or filter water fast arhae kya krna padega bata dijiye
Membrain output chack kare
Ha know.
मेरे मेम्ब्रेन की एक साइड रिजेक्ट पानी आ रहा है लेकिन पियौर पानी नही आ रहा कैसे ठीक करू
मैंने आज sv भी बदल कर देख लिया लेकिन pure water नही आ रहा है मेम्ब्रेन में जबकि रिजेक्ट वाटर आ रहा है
Good info sir ,
अगर मे धोमाहोनो पहले देखता थो rk वाटर फ़ॉल्टर नही लेथ था । Any way good video
Aisa hai...
Sir, mere ground raw water 700 tds hai, bar bar membrane choke ho jaati hai, mai aapse ye janna chata hu ki konsa membrane or kitni GPD ka lagana chahiye 700 tds ground water, mere ground water mai chhar bahot hai. Aur flow restrictor kitne wala lagana chahiye isme... Aapka bahot bahot dhanyavad
Sir RO ka tank full hone k bad jad power off karte hain kuch der bad tank se pani kam ho jata hain but tank main koi leakage nehi hain..... Float valve v sahi se power cut kar raha hain.... Iska karan kaya hain?
What is best price of memren & UP.
Hum deti h 1 year warranty sab chij ki
अच्छा करते हैं, आप...
Super Bhai
Very good information khatiyani johar dada
CONT ME URGENT 7900000060
Sab thik hai but membrane se pure water nhi aa rha hai but waste water speed se chal rha hai membrane new fit kiya fir bhi pure water nhi aa rha
sir bluestar water purifier ka video dikhaye.
Normal water drop drop a raha hai reject water normal a raha hai lakin motor ruk ruk ke chal rahi hai
Kuch na kuch naya sikhne ko milta hai aapke video dekh kar aapane to PHD kar li R.O me
RO Sector का मैंने अभी तक ठीक से क,ख,ग,घ भी नहीं सीखा है...
Sir jitna TDS handpump ka hai utnahi TDS to ka hai .or TDS set karne par vi utnahi ro ka TDS bta rhai hai to kya kre
WHO ne tds 300se 400 takkka tds excellent bataya hai
Replying back
membrane housing se reject water aa raha hi lekin pura water nhi aa raha hai jabki membrane bhi new hai or sabhi parts bhi new hai
सर ro के लिए अच्छा सर्व्हिस कीट कौनसा लेना चाहिए..।जीसमे मेम्ब्रेन सेडीमेंट कार्बन फिल्टर अच्छा हो..।
और sv कौनसा अच्छा है उसकाभी link दीजीए।
Csm 80 membern lex pure carbon block and lex pure sediment sv slx lana
Meri active copper ka aqua he,aj kucha time keliye pura system slow tha,phir khudse chalu hogeya phirse slow,mene chake kiya corrent connection ka probelm nenhi tha,to ye knu hua
You should send the pic of your ro system on my what's app no.- 9204019254
Itne se work me,km se km kitna rs lgna chahiye? sir
Tum ko service ke liye kaise bulai ?
Machine band hone ke baad bhi rejected water discharge kyo hota hai, or ese kaise repair kare
Solenoid valve change kr do
Hello sir
Mere RO me b same prblm he .pura pani discharge ho kar bahar aa raha he aur leakage bhi he .3000 rs ka cost hoga bol rahe he repairing k.Itna dena chahiye ??
No, without troubleshoot, we can't confirm that which filters are choked.
All types Ro solution 9560212600
Nhi bhai, 1800 se upar mat Dena... 3000 Jada ae
Membrane konsi company ki le
After ro water drinking with tds 8.. I have dycentry and some pain in mouth.. I dnt know why...
You increase tds of ro water. But this is not related with your health issues.
Good information
Thanks bro...
1. Dray membren 2.Wet membren Konsa achha ha
Wet CSM is better.
Great boss apke video dekh dekh kar mene apne aap hi pura ro assemble kar liya .Agar mobile no. Mil jaye to koyi problem aane per aapse thodi si jankari le sakte hai kya
You can ask on my whatsapp no.-9204019254
Awesome
Excellent video🙏
Hello
Hi ! Friends...
Sir kya membrane replacement k saat flow ristricter bhi replace karna chahiye.
बिल्कुल
सविसीग चार्ज कितना है
Ro Repairing Tools Ke Uper ek video Bana Do
Raw water tds kithna...
500 ppm ke andar hee tha.
Filter band hone ke bad bhi FR che bund bund Pani nikal raha hai SV bhi check kr li lekin fir bhi FR se pani nahi band ho raha.. andar ke sabhi candle badal diye hai tabhi se ye problem aa raha hai.. please bataiye abhi kya kare.. service dele vala admi bhi hat upar kr Chuka hai usse bhi problem solve nahi hua..
Bhai same problem , aapka resolve hua issue ?
@@alokrai744 ji solve ho Gaya...
I'm Frist Like
Ro is electrically ON. But not filtering hard water.
There are the problems of inline filters.
@@ROWaterSupport we used to filter soft water into ro water for 8 months. And now again started to filter hard water but taste is horrible it's just like hard water
I'm Shaikh Mosin
Good demo for this product thanku sir
But sir mujhe apki tode help chahiye
Help ke liye WhatsApp kijiye-9204019254
@@ROWaterSupport mere ro me bhi pure water drop drop A raha hai aur reject sahi hai. Lekin maine membrane change kiya to naya wala bhi kaam nahi kar raha. Sv bhi sahi hai. Motor ka pressure sahi lag raha hai but aapke nahi dekha. Kya problem ho sakta hai. Era system Kent pearl hai. 4 month se pareshan hoon. Koi help kare.
@@homeoveda7034 membrane duplicate daal diya hai apne bhai
Nice
आदरणीय सोलेनाइड वाल्व को कैसे चेक किया जाए कि खराब है या ठीक है
Solenoid Valve se related kaee video hai, mere channel par unhe dekhiye, samajh me aa jayega....
Solenoid Valve Repairing Videos: th-cam.com/play/PLf27BpBrsH-H7DEmxk9-pn6p5WwrZy0Hj.html
Kya RO water purifire ki switch raat ko band kerne ki wajah se RO kharab hojata hai kya ?sir plz reply
No, this can be electrical fault....
Kuch nahin hota hai. You can switch off if u want to.
Good vdo
These are the best videos n this channel reguardind the the RO Support. By watching this I confidently changed the solenoid valve. Also I got information regarding leakage and now I got to know that I need to change push to push elbow
Meanwhile I applied PVC cement and Teflon tape on that. Also how much times Teflon tape is to move around I got to know on this channel. Really informative.
i guess im asking the wrong place but does anybody know of a method to log back into an Instagram account?
I was dumb lost my password. I would appreciate any help you can offer me.
@Phoenix Koa instablaster :)
@Remy Brandon I really appreciate your reply. I got to the site thru google and Im in the hacking process atm.
Takes a while so I will reply here later with my results.
@@phoenixkoa9771did it work mate?
Thank u very much for this valuable knowledge 🙏
sir agar membren ulta krke dall de to kya kucch time nikal sakta hai us se??
Nahi
मेमोरम कितने आता है
Very nice sir , यही video को मैं detail में देखना चाहता था के kent assembling के बाद यही सही assembling का तरीका है जो आपने किया हैं, पर सर inlines को wash करने के लिए आपने जो T लगाया है जो एक मेम्ब्रेन को और एक tds adj.को जा रहा है उसी T से Inlines को washing कर सकते हैं। after all very nice and best video which never seen before in very simple language.👌👍
Karne se pahle koee vishesh planning nahi thee, esliye aisa hai. Kabhi-kabhi aisa karna parta hai, mujhe ...
Good Video
helpfull
75gdp k pump me sir apko 80gdp ka membrane Nahi daalna chahyea
Kyoan bhaee, aisa kyaoan bol rahe ho ?
@@ROWaterSupport 80gdp p hamesha 100 GDP pump use karte hai membrane ki life bhot acchi rahegi
Aisa nahi manta mera experience.
Nicely explained
SB kr diya lekin uv ka connection hi ni kiya
Sahi kaha aapne
Maimrain ya pump khraab hai
Membrane kharab hai
Cuter best
Thanks for this nice appreciation.
TDS kitna hona chahiye
50 between 90
Mera pani ka test nhi ata hai, TDs sahi hai,
Sediment, pre-carbon, post carbon Inline filters change kijiye.
Konsi campany acchi hai..
Hiw much do you earn on TH-cam?
Abhi maian TH-cam par kamane nahi aaya hai, thora-bahut jo mujhe samajh me aata hai, unhe share karne aaya hai.
@@ROWaterSupport good sir but apke view kafi hai aap uspe earn kar sakte hai
Great guru g
मोबाइल नंबर दीजिएगा
RK auqafresh sabse third class. Hai mere 15 din mai kharab ho gaya tha