Yaskawa V1000 AC Drive Start-Up Auto-Tune Demonstration Using The Keypad

แชร์
ฝัง
  • เผยแพร่เมื่อ 29 ธ.ค. 2024

ความคิดเห็น • 170

  • @GalcoIndustrial
    @GalcoIndustrial  10 ปีที่แล้ว +1

    +Teodora Perisin
    For some reason I was unable to respond directly to your comment, but I hope you can see this.
    An easy way to reset to the factory settings is to go to parameter A1-03. This will allow you to initialize the parameter values. You will change this parameter and save it, then change it back again to the parameter it once was. Every time you change this parameter, it resets back to the factory defaults of that set up (2-wire control, 3-wire control, etc..)

  • @rubenbuntinx3240
    @rubenbuntinx3240 8 ปีที่แล้ว +2

    Thank you :). I am a sixt grade student in Belgium and I use an Omron V1000 in my IP. I have to control the breaking and had no clue how to install it. I do now :)

    • @GalcoIndustrial
      @GalcoIndustrial  8 ปีที่แล้ว

      Glad you found the video useful Ruben. Good luck on your future projects.

  • @fordmodela3641
    @fordmodela3641 3 ปีที่แล้ว +1

    Helpful, the manual was a bit confusing on the auto tune procedure.

  • @dharmendrasuthar4342
    @dharmendrasuthar4342 2 ปีที่แล้ว +1

    how much is the output frequency mentioned on the vfd?
    cant see clearly.

  • @buddha65281
    @buddha65281 ปีที่แล้ว

    Thank you, I was trying to find information regarding H.66 error. This video sure was informative and I did.find that the H.66 was a "safety" latch that seems to be malfunctioning. Would be nice if there were more informational videos on how to test or diag safety latches.
    Thank you so very much.

  • @engoland
    @engoland 3 ปีที่แล้ว +1

    Hello GalcoTV Team. I have a Yaskawa V1000 VFD with an error on display which shows "_rgtb ". Do you know what it could be.

  • @herdemgermiyani6438
    @herdemgermiyani6438 4 ปีที่แล้ว +1

    Hi and thanks for the video.
    I have a Yaskawa CIMR-VCBA0012BAA to be installed for my parents. The aim is, to convert single phase power supply to operate 3 phase submersible water pump. I'm still struggling with wiring and programming though, but if it's even done correctly, my elderly parents are gonna struggle with operating the unit,so my question is:can l Install a water pump control panel in between the Yaskawa inverter and water pump to make it simpler? Many thanks for the time and help of anyone who can help.

  • @MrWadja
    @MrWadja 6 ปีที่แล้ว +1

    Hi . Is this instruction for "J 1000" too?

  • @eddtv5058
    @eddtv5058 5 ปีที่แล้ว +1

    Good day, i have a question. I have like that yaskawa v1000 and it is controlling a industrial washing machine.. My question is how do i reverse the rotation of the motor when the duration step in the.washing machine is in the extraction phase?

    • @eddtv5058
      @eddtv5058 5 ปีที่แล้ว

      How to reverse the rotation of the motor in that yaskawa v1000?

    • @GalcoIndustrial
      @GalcoIndustrial  5 ปีที่แล้ว

      Then you must get your controller connected to the drive to close the reverse input and open the forward input.

  • @misplacedpawn
    @misplacedpawn ปีที่แล้ว

    How do you get the startup to be set in local as default instead of having to manually change it from remote?

  • @sudhirv.p1556
    @sudhirv.p1556 8 ปีที่แล้ว +1

    Great what is the rotational and stationery tuning. also please guide me how to download the parameters. autotune is performed before downloading . Please help

    • @GalcoIndustrial
      @GalcoIndustrial  8 ปีที่แล้ว

      2 different drive modes for Rotational tuning, V/F Control or Open Loop Vector Control (or OLV mode).
      Both Control modes require the motor be uncoupled from its load before running Autotune. If uncoupling not possible or very difficult, the load at autotune must be less than 30% of process run load.
      OLV Control requires that the motor and the drive are closely matched in size (horsepower), V/F Control is more forgiving on motor size (will run smaller motors).
      Ok now Stationary autotune is for application where the motor cable is longer than 50 meters (164’) or application where the motor cable length was modified since precious autotune.
      Didn’t see it in the manual notes but probably doesn’t matter if the load is uncoupled or not.
      Always backup parameters after autotune, some values have been changed and need to be saved.

    • @sudhirv.p1556
      @sudhirv.p1556 8 ปีที่แล้ว

      +GalcoTV thanks for the information.as in my case the motor cable is not that much lengthy. I have to programme CIMR P7u series drive.how to download from my laptop

    • @GalcoIndustrial
      @GalcoIndustrial  8 ปีที่แล้ว +1

      I did not find any software or communication features available for the P7 series Yaskawa drives.
      They do however have a MODBUS communication option to interface to a PLC, but not a laptop.
      You can however copy parameters to your keypad referred to as the “Digital Operator” so you can at least backup what you have. see below.
      o3 Digital Operator Copy Function
      􀂄 o3-01 Copy Function Selection
      Note: The copy function is disabled when serial communication is active.
      􀂄 o3-02 Read Allowed Selection
      The digital operator has parameter COPY capabilities via built in non-volatile memory. The digital operator can READ all of
      the parameters in the Drive and store them for later WRITE back to the Drive or into a Drive with the same product code and
      software number. In order to read the parameter values and store them in the digital operator, select o3-02= “1: Enabled”. If
      you attempt to READ the data, which overwrites any previously stored data, without first setting o3-02= “1: Enabled”, you
      will get the following error:
      After setting o3-02= “1: Enabled”, it is possible to store parameter values in the digital operator by setting o3-01=1 (INV→OP
      READ).
      A successful READ of the parameter values will display:
      An error may occur while saving the parameter values to the digital operator’s memory. If an error is displayed, press any key
      to cancel the error display and return to parameter o3-01. Error displays and their meanings are covered in Chapter 6: Diagnostics
      and Troubleshooting of the E7 Users Manual (TM.E7.01). To COPY parameter values into a Drive, set o3-01= “2: OP-
      >INV WRITE”. During the writing of the parameter values into the Drive the digital operator will display:
      Setting Description
      0 COPY SELECT (factory default)
      1 INV→OP READ
      2 OP→INV WRITE
      3 OP↔INV VERIFY

  • @Jacob-64
    @Jacob-64 7 ปีที่แล้ว +1

    Hi,Ive just bought a couple of these . I've tried to power them up and i get error code H66 . Any advice,I've looked at the manual but I'm afraid it's way above me to understand .
    Thanks
    Sean

    • @GalcoIndustrial
      @GalcoIndustrial  7 ปีที่แล้ว

      Check if external safety circuit tripped and disabled the drive. If the Safe Disable function is not utilized, check if the terminals HC, H1, and H2 are jumpered.

    • @GalcoIndustrial
      @GalcoIndustrial  7 ปีที่แล้ว

      PS, it is not H66 it is Hbb, for Base Block, a safety feature built into the drive.

    • @Jacob-64
      @Jacob-64 7 ปีที่แล้ว

      GalcoTV hi , thank your for quick response I'm now up and running . Can you tell me how to save my settings , I lose them every time I turn of the power off in my workshop . Is there not a memory source or something similar .
      Thanks your video was very helpful indeed .😊

    • @GalcoIndustrial
      @GalcoIndustrial  7 ปีที่แล้ว

      These drives save the parameters automatically when you exit the programming mode. Not sure why it is not saving in your case. We suggest cycling power while you are present in front of the drive. Do you have a copy of the manual?

    • @GalcoIndustrial
      @GalcoIndustrial  7 ปีที่แล้ว

      For a digital copy of the Technical Manual to a Yaskawa V1000 AC drive click this link www.galco.com/techdoc/yask/v1000_tc.pdf

  • @rajendrasharma1317
    @rajendrasharma1317 6 ปีที่แล้ว +1

    Are these parmeters really same for all drives of yaskwa auto tuning

    • @GalcoIndustrial
      @GalcoIndustrial  6 ปีที่แล้ว

      Not necessarily. You will have to program your motor values first off, then the rest of parameters will be application dependent. Having said that, you can probably get running with some general settings like discussed here. Just please be aware that every application may have specific needs for optimizing performance, ok?

  • @timstudio1
    @timstudio1 9 ปีที่แล้ว +1

    I was wondering why I cannot start my drive remotely using only a 24v input from an external push button. I am not using the drive's 24v supply. Do I need to switch it to source? Also, is a common wire needed from the drive?

    • @GalcoIndustrial
      @GalcoIndustrial  9 ปีที่แล้ว +1

      +Tim Lawson Yes, you will have to change switch S3 to source, sink is the default, in order to have the drive operate from an external 24VDC signal. You will also need to connect a wire from the SC terminal of the drive to the common of your external source.

  • @rajatsubhra.ray92
    @rajatsubhra.ray92 8 ปีที่แล้ว +1

    In a hoist operation, V1000 is used for controlling two 0.55 kw motors. Using multifunction input contact S5 & SC, the speed should increase upto rated frequency of 50 Hz. But it is building upto 5.25 Hz. How can I rectify this? Please help

    • @GalcoIndustrial
      @GalcoIndustrial  8 ปีที่แล้ว

      +Rajatsubhra Ray I’m assuming that you have it programmed properly to so that the speed reference goes to 50 Hz when you select S5. If that is true, you may be going into current limit which will not allow the frequency to go above the point at which you hit current limit. When you select S5, measure the current on all three legs of both motors. They should be balanced and when you add the currents from one leg of each motor, that total should be below the maximum current you programmed into your drive at parameter E2-01. If you are running in V/F mode, you can disconnect the motors and then start the drive and select S5, if the output goes up to 50 Hz, then you are probably going into current limit. If it doesn’t go to 50 Hz, something is not programmed properly. If that is the case, I would need to know how you are setting the drive up to run at 50 Hz with S5 selected, are you trying to program in a speed or are you looking at an analog input.

  • @StupidPeasant
    @StupidPeasant 7 ปีที่แล้ว +1

    How do you look at settings on a running drive without stopping or changing anything?

    • @GalcoIndustrial
      @GalcoIndustrial  7 ปีที่แล้ว +2

      The Yaskawa V1000 series and most drives will allow you to look at parameter values while the drive is running and some can even be edited while in run mode as well. The drive will usually tell you a parameter is not changeable while running if you try to, ok?

  • @anapaulina3213
    @anapaulina3213 4 ปีที่แล้ว +1

    Hola podrías apoyarme con los parámetros de yaskawa V1000 para una aplicación de presión constante PID con transductor de presión de 4 a 20mA 0 a 16 bar . Te lo agradecería mucho.
    O como podría hacer que me arranque cuando detecte baja presión y al llegar a cierta frecuencia pare y vuelva a arrancar con bajo presión. Me urge porfavor responde.

  • @NguyenHuuLinh_
    @NguyenHuuLinh_ 7 ปีที่แล้ว +1

    Could you make a video about multi- Step speed of yaskawa E1000 AC drive?. tks a lot.

  • @giuseppebotto852
    @giuseppebotto852 หลายเดือนก่อน

    Nice video.
    Howerver you have input incoherend data: if you input 0.18 kW in T1-02 and 230 V in T1-03 and 1.4 A in T1-04 than you should enter 50 Hz in T1-05 and 1370 RPM in T1-07. The value of 60 Hz and 1660 RPM are related to the rated voltage of 277 V, not 230 V.
    Of course the motor run anyway if you mix the parameters too, but if you need a precise speed control proportional to the frequency you cannot make the related calculation, and the motor torque too could be not optimal.

  • @manjunathu5913
    @manjunathu5913 8 ปีที่แล้ว +1

    Hello, We are unable to load the program through drive wizards software for V1000 module from 1090 to 1021 version program, Can you please fix it

  • @HassanJaved92
    @HassanJaved92 5 ปีที่แล้ว

    I have a Yaskawa V100 installed in a metal detector . The display screen is not showing anything or any error just yellow back light. What could be the reason?

  • @mohammadmobin6971
    @mohammadmobin6971 ปีที่แล้ว

    What will happen, if after tuning we change E1-04 from 50 to 150Hz.
    As this done in rewinding machines rewinder, but dont know why is done, can you please explain that.

  • @sungrow91
    @sungrow91 4 ปีที่แล้ว +1

    how to set H3-02=20..Please share with me!

  • @joemontana3005
    @joemontana3005 9 ปีที่แล้ว +1

    Hi Galgo Tv!!
    Ihave problems with the auto-tune, i put all the data from the nameplate of my motor (0.55kW, 230 Volts, 4.2 A, 50Hz, 2850 RPM) but does not appears "Run 13", The display shows "Er-01". How can i fix the problem?
    Greetings from Mexico city!

    • @GalcoIndustrial
      @GalcoIndustrial  9 ปีที่แล้ว

      +Joe Montana Greetings! Verify that parameter T1-06 is 2, this is motor poles, and for a base speed 2850, it has to be set to 2. The default is 4 and when I put that in my drive, I got an Er-01 fault which means motor data is incorrect.

  • @EliseiDesign
    @EliseiDesign 10 ปีที่แล้ว +1

    Hi !
    I have bought a 4kw 17,5A Yaskawa V1000 for my 3phase, 12000-18000rpm, 200-300hz, 3.7 kw, 12A 2poles motor and when I am trying to perform AutoTuning, I get Error 11. How can I get past that? I have tried almost everything. Before that I didn't knew it was a 2 poles motor and it was set for 4 poles. It worked rough and the rotor was getting very hot but it was rotating. Now without autotuning performed when I hit the Run key it runs very nasty sounding like bearings not being greased at low speed and after a few seconds I get oL2 error. Thank you in advance !

    • @GalcoIndustrial
      @GalcoIndustrial  10 ปีที่แล้ว

      The sounds of the motor should be much smoother after autotuning. Er11 indicates the torque reference is too high. The Yaskawa manual suggests increasing the acceleration time. This assumes the drive doesn't have any errors and every thing else is properly programmed. Where did you buy the drive?

    • @EliseiDesign
      @EliseiDesign 10 ปีที่แล้ว

      GalcoTV The drive was bought from an online site from UK(buying overseas would add other consistent taxes). I believe the settings are not properly done. After following your video about a couple of times, I realized I was introducing some wrong data. Not being educated for this field is hard knowing or translating the technical terms. I was using for base frequency and for base voltage some smaller values(thinking that base would be something that you will probably run every day), but then I saw you introduce the data from the nameplate for those. The motor runs fine now(I believe), but the rotor still gets very hot. There is one thing I don't understand, with A1-02 set to 00(V/f control) at Auto-Tuning I can't set the T1-01 to 00(Rotational Auto-Tuning). So I had to chose at A1-02 the 02 option(Open Loop Vector). Would this be the reason for the rotor to become hot? Thank you !

    • @GalcoIndustrial
      @GalcoIndustrial  10 ปีที่แล้ว

      EliseiDesign That shouldn't be the case for the motor. Unless you have an encoder with feedback going back into the drive or you are using a permanent magnet motor the open loop vector selection should be fine. The few things I can suggest is looking at the current settings on the drive, checking the load, and recheck the size of the motor does not exceed the values of the drive. Is there a load on the motor? Also, Look at the nameplate of the motor... What letter is the insulation rating?

    • @EliseiDesign
      @EliseiDesign 10 ปีที่แล้ว

      GalcoTV Oh, so that is fine then. Good to know! There is no load on the motor and I don't see the insulation rating on the nameplate. The motor is 3.7 kw at 220v and 5.2kw at 330v(but my drive can only deliver up to 220v, so just 3.7 kw). The drive should be able to deliver what it needs. This is a link with an exact motor as mine picclick.com/Giordano-Colombo-Spindle-Motor-RV-902SB-CNC-Mill-190895091037.html and this is the exact driver CIMR-VCBA0018BAA Inverter V1000, 200 V, CT: 17,5 A / 4 kW, IP20 . I will check and recheck and again and again; it seems like I am getting closer. :D Thank you for helping me ! Elisei

    • @GalcoIndustrial
      @GalcoIndustrial  10 ปีที่แล้ว

      EliseiDesign
      I found a motor similar to yours that is suggesting 15 amps at 220 volts (does the nameplate say 12 or 15?). Without seeing the motor itself it is a little difficult to help. Spindle motors can be a little tricky with drives and it might be a good idea to contact Yaskawa's tech support. Since we are based in North America, I'm afraid our tech support wouldn't be as beneficial to you.

  • @Electrical-Automation
    @Electrical-Automation 5 ปีที่แล้ว

    How to remove ope03 error for Up/down command

  • @sanatariq1498
    @sanatariq1498 9 ปีที่แล้ว +1

    how can i reduce the water pressure from 6.5 bar to 5.5 bar through yaskawa v1000 drive? i have 2 drives controlling 2 pumps.

    • @GalcoIndustrial
      @GalcoIndustrial  9 ปีที่แล้ว +1

      sana tariq There are too many variables that could affect the function of the drive. For instance we do not know if this application is utilizing the PID to control pressure or if it is a simple pressure sensor directly controlling the motor speed.
      Or some other pressure control scheme.

    • @sanatariq1498
      @sanatariq1498 9 ปีที่แล้ว

      GalcoTV There are 2 pressure transmitter (4mA to 20mA, 0 Bar to 10 Bar) utilizing the PID to control pressure.

  • @shadowlife6997
    @shadowlife6997 3 ปีที่แล้ว +1

    I can't able to run the motor for 60 Hz , motor gets over load , why?

  • @ghasen1000
    @ghasen1000 6 ปีที่แล้ว +1

    can i command this ac drive with a tachometer dynamo

  • @srinathvenkatesha8273
    @srinathvenkatesha8273 8 ปีที่แล้ว +1

    yes but we are unable to start the motor ..now no alarm message
    thanks

  • @franklina.5389
    @franklina.5389 7 ปีที่แล้ว +1

    Could you give us an explanation how to use it in the remote control, please
    Thanks in advance

    • @GalcoIndustrial
      @GalcoIndustrial  7 ปีที่แล้ว

      Sure, first connect a speed command to it (pot or 0-10volt source), then connect a start switch/contact to the start input and put the drive in remote with the LO/RE button, if the LED is off it is in remote mode, ok?

  • @etzcorndan9063
    @etzcorndan9063 5 ปีที่แล้ว

    I have a Yaskowa J-1000 AC drive, attempting to feed a old Emerson, 3PH motor, 2 HP, 230volt, 5.6amps , 1710rpm. motor nameplate has no kilowatt info, how do I figure that out?

  • @orwad7916
    @orwad7916 7 ปีที่แล้ว +1

    Great video.

    • @GalcoIndustrial
      @GalcoIndustrial  7 ปีที่แล้ว

      Thank you. If there is anything else you would like to see we haven't done already, please put your request in right here.

  • @bismillahelectronicsindust9824
    @bismillahelectronicsindust9824 5 ปีที่แล้ว

    Please you can using encoder cards b2 on yaskawa inverter and connection then hwo operate inverter see on little clip thanks

  • @yonathaneliaguirreabrego7122
    @yonathaneliaguirreabrego7122 8 ปีที่แล้ว +1

    Muchas Gracias y Saludos desde México....

  • @perisin_
    @perisin_ 10 ปีที่แล้ว +5

    can anybody tell us how to reset to factory settings so we can try this test set up.please

    • @deepakbagiyal5652
      @deepakbagiyal5652 6 ปีที่แล้ว

      Teodora Perisin. Feed n0001-12

    • @kylewoodbury2195
      @kylewoodbury2195 6 ปีที่แล้ว

      A1-03 = 2220 and hit enter. This will set it back to factory settings for 2 wire control

  • @davb31
    @davb31 7 ปีที่แล้ว +1

    How do I get the remote to work on this

    • @GalcoIndustrial
      @GalcoIndustrial  7 ปีที่แล้ว

      The LO/RE Selection Key switches drive control and frequency setting between the operator (LOCAL) and an
      external source (REMOTE). The LO/RE key can only switch between LOCAL and REMOTE when the drive is stopped. To disable the LO/RE key to prohibit switching between
      LOCAL and REMOTE, set parameter o2-01 to 0.

    • @davb31
      @davb31 7 ปีที่แล้ว

      Hello again I can’t seem to get a it to switch over from local to remote

  • @StupidPeasant
    @StupidPeasant 7 ปีที่แล้ว +1

    What does stationary tune mean?

    • @GalcoIndustrial
      @GalcoIndustrial  7 ปีที่แล้ว

      The Yaskawa drive allows you to "Auto-tune" your motor to it without any rotation of the motor shaft. It is not as precise as a rotational tune is but it may be adequate in some cases where disconnecting the motor from its load may not be possible. Allowing the drive to rotate the shaft without anything connected to it is the best way to Auto-tune where possible, ok?

  • @srinathvenkatesha8273
    @srinathvenkatesha8273 7 ปีที่แล้ว

    please Help us Connecting to the drive using Serial connection and RJ45

  • @pauloyoshizaki2103
    @pauloyoshizaki2103 2 ปีที่แล้ว +1

    Yaskawa - Robótics - Automação -
    Future - Começou - Globalizado .

  • @svenkrause3433
    @svenkrause3433 4 ปีที่แล้ว

    In my V1000 the menue Arun doesn't exist, why?

  • @nelsonvaldoyaurichocce4677
    @nelsonvaldoyaurichocce4677 7 ปีที่แล้ว

    El manual en español no me aparecen esos parametros r1-00 sucesivamente para placa de motor porque?? tengo que ir al parametros? y configurar ahi? o como ?? porque segun el video esos parametros no veo en el maunal ...

    • @GalcoIndustrial
      @GalcoIndustrial  7 ปีที่แล้ว

      Hola Nelson, ten en cuenta que la pantalla muestra lo que parece una "r" pero que en realidad es una "t". Todo lo que Katie habla en este video está en el manual. Para obtener una copia digital en formato PDF del manual técnico, haga clic en este enlace www.galco.com/techdoc/yask/v1000_tc.pdf

  • @bismillahelectronicsindust9824
    @bismillahelectronicsindust9824 4 ปีที่แล้ว

    Hi medam i have yaskawa drive in fault cpf06 can you tell me thanks

  • @sattibabu229
    @sattibabu229 7 ปีที่แล้ว

    hi, recently i installed yaskawa v1000 its running auto control mode but while i'm going to parameters settings drive goes to manual mode and get stopped ,,i didn't get what is the problem .please be reply me as early as possible
    .

    • @GalcoIndustrial
      @GalcoIndustrial  7 ปีที่แล้ว

      Please be aware that some parameters can not be edited while in operation. Do you have a copy of the manual? If not please follow this link www.galco.com/techdoc/yask/v1000_tc.pdf

    • @sattibabu229
      @sattibabu229 7 ปีที่แล้ว

      yes i was edited all parameters from old drive but p1 and p2 outputs not coming i gave 24 volts to pc common terminal

    • @GalcoIndustrial
      @GalcoIndustrial  7 ปีที่แล้ว

      Ok if you look at page 63 in the manual it will show you to connect your power supply common to PC, then P1 and P2 go to your load (indicator lamp or PLC input what ever you are using them for) and the +24 goes to the common of your load not the drive, ok?

  • @thatipamulabikshapathi2399
    @thatipamulabikshapathi2399 7 ปีที่แล้ว +1

    Thank you exlent video great information

  • @hacilonixowy
    @hacilonixowy 7 ปีที่แล้ว +1

    should not be set to 50hz ? motor 230v

  • @jagadishthakor1666
    @jagadishthakor1666 7 ปีที่แล้ว

    Please solutions over voltage alarm of acdrive

    • @GalcoIndustrial
      @GalcoIndustrial  7 ปีที่แล้ว

      Usually this means you have to increase your DECEL time, the drive is being overhauled by a large inertia load. If the process requires your rate of decal, you may need a brake resistor or check that the brake resistor you are using is ok (may have a fuse in series with it that opened or blew out) ok?

    • @jagadishthakor1666
      @jagadishthakor1666 7 ปีที่แล้ว

      GalcoTV thanks

  • @jacksearle4543
    @jacksearle4543 9 ปีที่แล้ว

    The drive shows SC. please inform what it means and how to reset.

    • @GalcoIndustrial
      @GalcoIndustrial  9 ปีที่แล้ว

      +jack Searle SC means short circuit. Try turning off the power, wait a few minutes to make sure the capacitors have discharged, disconnect the motor then power up and run the drive. If the drive runs, you should check the wiring and motor for a short between the phases. If you still get the SC fault, you may have a bad drive.

  • @mohammedasif-wu6wr
    @mohammedasif-wu6wr 9 ปีที่แล้ว

    hi sir can you please help me with this machine we are using same machine in our company in alm display it is showing "Uu1" can u tell me how to fix it

    • @GalcoIndustrial
      @GalcoIndustrial  9 ปีที่แล้ว

      mohammed asif First you will need to identify the problem. Uu1 is the fault for DC bus undervoltage and can be caused by input power phase loss, loose input terminal wiring, improper voltage coming in, power interruptions, worn internal circuitry, drive internal temperature, or problem with the charge indicator. Checking the quick start guide found on galco's website can outline how to correct each problem. You can find the link above in the description tab and then click on the V1000. Under the docs and links tab is the quick start guide. Fault Uu1 is found on page 138. I hope this helps.

    • @mohammedasif-wu6wr
      @mohammedasif-wu6wr 9 ปีที่แล้ว

      GalcoTV thanks for replying, please help me with one more doubt which is very important, we are running 3 phase motor for this drive, the motor specifications are (power)p1= 2.65 kw and p2=2.2kw, (voltage)=230-240 ^/ 400-415 Y, current in ampere is 8.3/4.8, frequency in hertz is 50 and (min-1) rpm is 2820 how many poles for this rpm?.Now please tell me what should be the reading for t1-01, t1-02, t1-03, t1-04, t1-05, t1-06, t1-07 i want to confirm my readings as i have put t1-01=3, t1-02=2.2kw, t1-03=230v, t1-04=4.8, t1-05=50, t1-06=2, t1=07=2820. Please help me with this table waiting for it thanks for co-operation i appreciate it.

    • @mohammedasif-wu6wr
      @mohammedasif-wu6wr 9 ปีที่แล้ว

      GalcoTV and if the air inside drive is too hot how to check the drive internal temperature and how to fix it?

    • @GalcoIndustrial
      @GalcoIndustrial  9 ปีที่แล้ว

      mohammed asif I can see a couple of problems with the data you have provided. The voltage setting that you have for t1-03 is 230 volts. This would suggest that t1-02 is 2.65 kW and t1-04 is 8.3 A. If your incoming voltage is 400 and the motor is configured for this, then t1-02 and t1-04 is right and t1-03 needs to change.

    • @mohammedasif-wu6wr
      @mohammedasif-wu6wr 9 ปีที่แล้ว

      GalcoTV can u provide me parameters from t1-01 to t1-07 according to this motor specification please it will great help for me because we dont have technician for this drive

  • @srinathvenkatesha8273
    @srinathvenkatesha8273 8 ปีที่แล้ว

    please help us how to reset the Hbb Fault Alarm

    • @GalcoIndustrial
      @GalcoIndustrial  8 ปีที่แล้ว

      Hello,
      The HBB fault means that the terminal H1 is open or has no signal for the “safe disable” input.
      Terminals HC, H1, and H2 need to be linked if there is no external contact or signal source to keep the safe disable input satisfied.
      If the signal is present or the terminals are linked (jumped), then the drive is defective and needs repairing or replacing.
      Hope this helps!

    • @srinathvenkatesha8273
      @srinathvenkatesha8273 8 ปีที่แล้ว

      thanks we have connect the jumper . now no alarm
      and we have connected the motor but its not starting

    • @GalcoIndustrial
      @GalcoIndustrial  8 ปีที่แล้ว

      3 suggestions for you to try:
      Is it in local or remote mode? Make sure the LED is off on the LO/RE button.
      Then check for signal at the S1 or S2 input with respect to the SC terminal at the control inputs.
      If that’s all good, we still have to tell it how fast to go with speed command at analog input A1 with respect to AC.
      Let me know how this goes and we will try to help you further from there.

  • @chinthakanaotunna4612
    @chinthakanaotunna4612 9 ปีที่แล้ว +1

    my YAsakawa drive I used it for Fwd and reverse function of a motor. I switched the SC and S1 motor starts but once i removed it motor doesn't stop. so i have to power off the driver. same scenario for the reverse operation. Pl help me to fix this.

    • @GalcoIndustrial
      @GalcoIndustrial  9 ปีที่แล้ว +1

      +China Aripp I need some answers before I can help you. What value is in parameter b1-02, and How are you selecting reverse?

  • @josecarlosfranca6397
    @josecarlosfranca6397 4 ปีที่แล้ว +1

    Pode ser em português?

  • @nasubash
    @nasubash 7 ปีที่แล้ว

    my yaskawa v1000 showing ol2 alarm. I need know how to resolve by drive.

    • @GalcoIndustrial
      @GalcoIndustrial  7 ปีที่แล้ว

      OL2 is Drive Overload. The thermal sensor of the drive triggered overload protection.
      (see page 134.)
      www.galco.com/techdoc/yask/v1000_qs.pdf

    • @nasubash
      @nasubash 7 ปีที่แล้ว

      thanks a lot. I solved it.

    • @javiervelasquez3950
      @javiervelasquez3950 6 ปีที่แล้ว

      @@nasubash How did you solve it?

  • @tweenie271
    @tweenie271 7 ปีที่แล้ว

    Hi guys, i want to ask how to unlock the parameters of yaskawav1000, i want to change parameters, many rhanks.

    • @GalcoIndustrial
      @GalcoIndustrial  7 ปีที่แล้ว

      No problem Manny, go to parameter A1-04; The password is selected via parameter A1-05. The selected password must be entered in parameter A1-04 to unlock parameter access.

  • @hallmarktechnicalservices6933
    @hallmarktechnicalservices6933 6 ปีที่แล้ว

    how can i get this in Nigeria

    • @GalcoIndustrial
      @GalcoIndustrial  6 ปีที่แล้ว

      We ship to many countries around the world, to find out if we can ship to you, just give us a call at 800-337-1720 and ask for sales.

  • @zahoorahmedsaroya8982
    @zahoorahmedsaroya8982 8 ปีที่แล้ว +2

    wonderfull video

    • @GalcoIndustrial
      @GalcoIndustrial  8 ปีที่แล้ว +2

      Thank you Zahoor. If you think of anything that you would like to see demonstrated just write a reply right here.

  • @ravikumaryadav912
    @ravikumaryadav912 7 ปีที่แล้ว

    my yaskawa v1000 drive is showing overvoltage alarm in backup (rescue) mode

    • @GalcoIndustrial
      @GalcoIndustrial  7 ปีที่แล้ว

      You must mean KEB Kinetic Energy Backup? There are 2 of these modes, and if you get OV trip you are probably using KEB1 which is based on a DECEL time regardless of load inertia. Try using KEB 2 mode (L2-01=2) that adjusts the decel time based on the bus voltage so that the DC bus voltage meets the level set in parameter L2-11.

  • @MasumBillah-nz8bk
    @MasumBillah-nz8bk 6 ปีที่แล้ว

    what is winding program?

    • @GalcoIndustrial
      @GalcoIndustrial  6 ปีที่แล้ว

      Well are you asking in general or in the drive?

    • @MasumBillah-nz8bk
      @MasumBillah-nz8bk 6 ปีที่แล้ว

      my drive model:CIMR-AB4A0011FBA

    • @MasumBillah-nz8bk
      @MasumBillah-nz8bk 6 ปีที่แล้ว

      my drive is fault ---OH1

    • @GalcoIndustrial
      @GalcoIndustrial  6 ปีที่แล้ว

      Oh ok, this means the Heat-sink in the drive has overheated. Check and make sure the cooling fan(s) are running. Make sure they are not blocked and you can feel air out the top of drive, ok?

    • @MasumBillah-nz8bk
      @MasumBillah-nz8bk 6 ปีที่แล้ว

      I want to new drive use

  • @mdmehedi8912
    @mdmehedi8912 2 ปีที่แล้ว

    how to set modbus address v1000 and a1000 please help me

  • @lovemorechimonyo5065
    @lovemorechimonyo5065 10 ปีที่แล้ว

    how can i reset a varispeed yaskawa v1000 on an extractor fun

    • @GalcoIndustrial
      @GalcoIndustrial  10 ปีที่แล้ว

      I am not sure if you have a fault you are looking to reset or you want the drive to reset to factory settings (out of the box settings). If you are looking for resetting the drive because of a fault condition, then you will need to find the fault and clear it before pushing the reset button located above the run button on the keypad. For example, if there is a short somewhere, you will need to fix it before resetting the drive.
      If you are looking to reset all of the parameters and start fresh then you will need to initialize the drive. Our techs and docs link on any of the V1000 products will allow you to download the technical catalog. On page 104-5 there are steps to initialize the drive with the A1-03 parameter. You can initialize the drive to whichever configuration you have.
      Warning: Initializing a drive will reset all parameters. Make sure you know what you are doing and what your motor settings are before you initialize the drive.

  • @sudhirv.p1556
    @sudhirv.p1556 8 ปีที่แล้ว +1

    many thanks for the reply.

  • @anasnori9801
    @anasnori9801 10 ปีที่แล้ว +5

    i watch this & ABB ACS550 AC Drive and sure abb drive is more easy to operate and to program...... just my opinion

    • @GalcoIndustrial
      @GalcoIndustrial  10 ปีที่แล้ว +1

      All drives tend to have a learning curve. I will admit that the advanced keypad has greater resolution on the ABB drives, but both do require knowing how to navigate. The Yaskawa keypad is also very responsive and easy to navigate, which is often underestimated when operating a drive through the keypad.

    • @mayracontreras6271
      @mayracontreras6271 9 ปีที่แล้ว

      GalcoTV un m hmm mmmmo km o

  • @rspandeyec
    @rspandeyec 6 ปีที่แล้ว

    How to change motor direction in yascava ac drive

    • @GalcoIndustrial
      @GalcoIndustrial  6 ปีที่แล้ว

      If you have not changed from the standard Macro, then S1 is forward run input and S2 is run reverse

    • @rspandeyec
      @rspandeyec 6 ปีที่แล้ว

      I want motor direction change from key pad of drive
      Then how to change

    • @GalcoIndustrial
      @GalcoIndustrial  6 ปีที่แล้ว

      You may have to verify parameter b1-04=0 (reverse operation enabled), put in LO (local mode) with LO/RE button and LED in button should be lit. Then push Enter button and up/down arrow until rEv displays and push enter again.

    • @GalcoIndustrial
      @GalcoIndustrial  6 ปีที่แล้ว

      Got it now?

  • @surinderkumar-by7lx
    @surinderkumar-by7lx 7 ปีที่แล้ว

    please tell me how to auto restart v1000 parameters

    • @GalcoIndustrial
      @GalcoIndustrial  7 ปีที่แล้ว

      To reset the drive and set parameters to their default values, end users need to use the “Initialize” command in the V1000’s A1 Menu. This is done at parameter A1-03. The value should be set to 2220, for factory two-wire control or 3330 for 3 wire control.

  • @gunaseelan6962
    @gunaseelan6962 12 ปีที่แล้ว +2

    good product yaskawa

  • @jesusverdugo5848
    @jesusverdugo5848 8 ปีที่แล้ว +1

    Problema con un yaskawa v1000
    No cambia los parametros
    Alguien sabe como solucionarlo?

  • @ahmadkabbani3829
    @ahmadkabbani3829 6 ปีที่แล้ว

    I have yaskawa , model : cimr . f7j4132 . please sent to wireing - up diagram

  • @HassanHassan-uq3fd
    @HassanHassan-uq3fd 6 ปีที่แล้ว

    How is تحفيض Number of floors elevator Can you help me please

  • @patelsahdev2521
    @patelsahdev2521 ปีที่แล้ว

    Hi sister i from India you will teach me yeskawa ga500 drive its my dreem and I have worked hard to learn please 🙏 help me??

  • @narinderbatish4772
    @narinderbatish4772 7 ปีที่แล้ว

    How to decided Motor pole according Rpm

    • @GalcoIndustrial
      @GalcoIndustrial  7 ปีที่แล้ว +1

      This is an excellent question Narinder. For standard induction asynchronous AC motors it's easy. If rated 1750RPM @ 60Hz, it would be safe to say the synchronous RPM is 1800, this is a 4 pole motor. If rated 3450RPM @ 60Hz this is a 2 pole motor. Up in RPM = down in pole count. If rated 870RPM @ 60Hz synchronous RPM is 900 or an 8 pole motor, ok?

  • @joseguadalupecamposhernand5886
    @joseguadalupecamposhernand5886 4 ปีที่แล้ว +1

    Podrían pasarlo a español

  • @hasemislam3983
    @hasemislam3983 2 ปีที่แล้ว +1

    Love

  • @hindustantechno3132
    @hindustantechno3132 ปีที่แล้ว

    Apako Hindi ati ho please share the link

  • @julioaugustolutgehetmann2434
    @julioaugustolutgehetmann2434 5 ปีที่แล้ว +1

    en español , por favor

  • @KashifaliKashifali-r4n
    @KashifaliKashifali-r4n 10 หลายเดือนก่อน

    I got at lot of hlep from your video, wolud you like to help me soemething elso?

  • @hadyatali6683
    @hadyatali6683 8 ปีที่แล้ว

    so good vedeo

  • @gustavoamaya2069
    @gustavoamaya2069 11 ปีที่แล้ว

    GOOD PRESENTATION

  • @asirthangam8553
    @asirthangam8553 10 ปีที่แล้ว

    Nice

  • @MasumBillah-nz8bk
    @MasumBillah-nz8bk 6 ปีที่แล้ว

    my drive model :CIMR-AB4A0011FBA

  • @pubgserviver3737
    @pubgserviver3737 5 ปีที่แล้ว

    U Contact pc & leptop

  • @francoisesseyi5105
    @francoisesseyi5105 4 ปีที่แล้ว

    Je veux en français

  • @MasumBillah-nz8bk
    @MasumBillah-nz8bk 6 ปีที่แล้ว

    please help me

  • @deepakdeepakkewat8976
    @deepakdeepakkewat8976 6 ปีที่แล้ว

    Motar sepireet controlling Purogramig

  • @soponhossain3563
    @soponhossain3563 5 ปีที่แล้ว

    Hide show pargarm do

    • @GalcoIndustrial
      @GalcoIndustrial  5 ปีที่แล้ว

      Can you ask this another way, it makes no sense

  • @shivasw483
    @shivasw483 11 ปีที่แล้ว

    thanksssssssssssssssssssssssssss

  • @mahmoudradwan1040
    @mahmoudradwan1040 7 ปีที่แล้ว

    Want translation into arabic

  • @huysim5216
    @huysim5216 5 ปีที่แล้ว

    5 c