Do you have any information on a Mitsubishi F-500 VFD? As far as setting the parameters? My company purchased an old jaw crusher with a 150hp motor. And we have no manuals on this machine at all. Thank you
Hi, Sir, I am from Bangladesh. Our company bought a Mitsubishi A800 VFD for operating Atlas Copco 90VSD compressor. We properly installed all electric and mechanic parts of this compressor. Electrical wiring and mechanical fitting is ok. But this VFD gave high amphere 180amp to 200 up amp. The parameter setting P9 is 210A. Compressor setting 10bar. When run then after (2 - 3)minitues VFD goes to trip condition which desplayed TH again and again then displayed E.FIN. I give you two picture with this sms which is Motor and Compressor nameplate. Please give me solution how we solve this problem. We also communicate with Bangladeshi representative for this problem, but they didn’t give proper solution.
Very useful video, really helpful while programming the A800 series inverter. However, please let me know, while connecting via HMI & PLC by RS485 which parameter we should enter?
can you program your speed according to a external datum input, exemple the distance of a element on scale closer from the center of rotation faster the motor run?
Basic stuff , so the comment ‘ informative ‘ is appropriate only unfortunately. If a video detailing the setting up of the VSD being controlled by a transducer or potentiometer! then a comment from me would be ‘ very informative ‘ but there won’t be a video on that as we don’t need every Tom dick and Harry knowing how that works , get it ? 😉
Hello, every two days I get a nuisance E.SAF alarm on my FRD700. I'm new to vfd's is this something I can bypass on a parameter?
Pls,Help me function PLC for A800,thanks.
Please 8nwould like to ask this
How can I bypass innovance inverter password
I have problembaju,
The inventer Mitsubishi A800 Error indication is E GF..
Whats solution??
Output side earth ( ground ) fault overcurrent
What type of VFD do hospitals normally use?
How to closed in case of fire alarm (escaletor
Fell over at first instruction will not go into PU mode !
Canaktion terminal on. off protaction
How to program for encoder feedback
Also how to set parameter 168 & 169
Pm moter programing
I bought a800 a few month but it always trip , how to solve this problem mitsubishi dealer cannot solve
You can convert the 800 series to 700 with a convertion kit, basically using a terminal Block from 700
How solve undervoltage fault
Sir I would like to how to syncronize three Mitsubishi FR A800 drives
Sir how to speed up and down by using push switch. Please sir give this parameter and connection
Do you have any information on a Mitsubishi F-500 VFD? As far as setting the parameters? My company purchased an old jaw crusher with a 150hp motor. And we have no manuals on this machine at all. Thank you
Hi,
Sir, I am from Bangladesh. Our company bought a Mitsubishi A800 VFD for operating Atlas Copco 90VSD compressor. We properly installed all electric and mechanic parts of this compressor. Electrical wiring and mechanical fitting is ok. But this VFD gave high amphere 180amp to 200 up amp. The parameter setting P9 is 210A. Compressor setting 10bar. When run then after (2 - 3)minitues VFD goes to trip condition which desplayed TH again and again then displayed E.FIN. I give you two picture with this sms which is Motor and Compressor nameplate. Please give me solution how we solve this problem. We also communicate with Bangladeshi representative for this problem, but they didn’t give proper solution.
In order to get to PU my VFD wants a password but Mitsubishi tech support doesn’t know how to get past that. Any idea how to get past that?
Pr-0 Torque boost .how to set and what is the piroty in this setting.
Can u guide me which VFD is best suited for 20hp induction motor 3-phase reciprocating air compressor??
So basically the same set up as the Mitsubishi E700 series right? Seems almost identical. Thanks for the video
Thankអរគុណ
Hey can you please explain FR-A800 plus R2R drive torque setting by the external voltage or current..
Hey buddy I got a question I’m an hvac tech I have one of these but I only got a picture of it I don’t have the model number
how to parameterize the A800 series inverter, to visualize the Rpm
Is there a way to set it to run manually and then program it back to auto? Like you do with the 525?
Very useful video, really helpful while programming the A800 series inverter. However, please let me know, while connecting via HMI & PLC by RS485 which parameter we should enter?
Good Sujetion sir very very smart Loketion 👍
Drive hardware
Sir how to run this drive with out external potentiometer plz explain
Please tell push button through drive start and parameter set
Nice video Sir. But could you tell us that how will do control wiring? Thanks
Please share analog control also .............
can you program your speed according to a external datum input, exemple the distance of a element on scale closer from the center of rotation faster the motor run?
thanks alot, youve saved my job
Why set VFD to 0 which is constant torque mode. What does this mean ?
Thank you :)
how setup pid terminal 2 0-10v. thanks
You're explanation is👌
how to set default seating A800
Sir please tell how to connect remote connection with ricever
Thank You Sir ☺️
Please how can I change from NET TO EXIT OR PU
Press [PU/EXT] until you select desired mode. But if you have it set to use the NET it will only go to NET or PU mode.
Good Sujetion 👍
how to install A700 settings
Thanks sir
Thanks
very informative.. thank you
Basic stuff , so the comment ‘ informative ‘ is appropriate only unfortunately. If a video detailing the setting up of the VSD being controlled by a transducer or potentiometer! then a comment from me would be ‘ very informative ‘ but there won’t be a video on that as we don’t need every Tom dick and Harry knowing how that works , get it ? 😉
thank you sir
Best tutorial.. Loved It
Good
Thank you sir
hi
thanks a lot