HOW TO INSTALL GENERAC 25 KW / HOW TO CONNECT PROPANE GAS LINE (Pt. 4)

แชร์
ฝัง
  • เผยแพร่เมื่อ 27 ก.ย. 2024
  • HOW TO INSTALL GENERAC GENERATOR FOR YOUR HOME / CONNECT PROPANE GAS LINE (Pt. 4) / Check out Davenport Energy as they connect my gas line from the in ground propane tank to the 25KW Generac Generator.
    #Generac #GeneracGenerators #DavenportEnergy #standbygenerators #backupgenerators #generators
    www.davenporte...
    www.generac.com

ความคิดเห็น • 17

  • @howtodoitdude1662
    @howtodoitdude1662 6 หลายเดือนก่อน +1

    You are the only one I’ve seen use a drip leg on the gas line. Thank you for being so thorough and professional!

  • @nonyabeeswax2967
    @nonyabeeswax2967 ปีที่แล้ว +2

    I'd get rid of the union between the generator and the flex line. You already have a union on either side of the flex line. I'd probably eliminate the union on the other side of the flex line as well. The reason to get rid of the first one is that it will see a tremendous amount of vibration, particularly on start up and shut down. Fuel tech's often use unions for appliances, but don't realize how much motion and vibration a generator has when running, unlike a furnace or water heater. At the least, I would do routine gas line checks with a detector and the appropriate liquid.

  • @Haymaker-rd6zp
    @Haymaker-rd6zp 7 หลายเดือนก่อน

    Is there any particular gas regulator should be used for a 26kw Generac generator?

  • @brandoncasey7124
    @brandoncasey7124 8 หลายเดือนก่อน

    The sediment trap is supposed to be installed before the regulator, just fyi

  • @ritterenterprises
    @ritterenterprises ปีที่แล้ว +1

    Why are you using galvanized pipe supposed to be black pipe for gas

    • @Respect.The.Grind..
      @Respect.The.Grind.. ปีที่แล้ว +1

      Black iron you still have to paint to avoid rust by code in most states.

  • @smitty2721
    @smitty2721 10 หลายเดือนก่อน

    Is the tracer wire made from copper or steel?

  • @ChrisJohnsonOk
    @ChrisJohnsonOk 2 ปีที่แล้ว

    What size galvanized pipe did they install? 1”? Thanks

    • @Respect.The.Grind..
      @Respect.The.Grind.. ปีที่แล้ว

      Looks like 3/4”. 1 “ would be too big I would have to assume

  • @ritterenterprises
    @ritterenterprises ปีที่แล้ว

    Why are you using galvanized pipe

  • @paulharper3411
    @paulharper3411 ปีที่แล้ว +2

    Thank you!! This video stopped a lot of back and forth this is how no this is how it done. On our first Generac install also so once again thank you very much !!!

  • @Alexander-fz7sd
    @Alexander-fz7sd ปีที่แล้ว

    I live in Oregon and amerigas came and filled our propane tank but they refuse to come out and hook it up to the generator

  • @mlevass1
    @mlevass1 ปีที่แล้ว

    I'm doing the same thing good video, have you figured how long the tank will run your generator

    • @ProjectNEXT1
      @ProjectNEXT1  ปีที่แล้ว

      My burn rate is 5 to 6 gal. per hour. Over 400 gals. in tank. Days !!!! Thanks for watching !!!!!

    • @Brad.W
      @Brad.W 9 หลายเดือนก่อน

      Typically a 500 gallon tank gets filled to around 430-450 gallons I didn't catch what size generator he has but i basically have a similar setup and after a couple of extended outages in the past i learned that a full 450 gallons of LP will run a 24 KW Generac roughly 3.5 to at the most 5 days straight days depending on how much of a load you keep on it. Me personally I typically try not to run any of my large 240v appliances other than my heat and air which is a variable speed Trane heat pump system during an outage all food we eat is either take out or nuked.