How to check & find Earth fault in DC System | Substation | Power plant

แชร์
ฝัง
  • เผยแพร่เมื่อ 26 ส.ค. 2024
  • DC Earth fault in DC control system is very usual which occurs in substation, power plant or anywhere in control circuit where DC supply is used for control purpose. Finding earth fault location is very difficult task so before getting started to check DC earth fault we must know the basics of DC system and practical practice to use multi meter or DC earth fault detector.
    For Practical Understanding keep watching my videos !!
    #Subscribe my Channel for more practical videos !

ความคิดเห็น • 230

  • @hanumandasji8027
    @hanumandasji8027 4 ปีที่แล้ว +2

    Thank you for your valuable lecture sir. We are also facing the same problem in our 220kv grid. Now I will try to rectify it.

  • @manoranjan4598
    @manoranjan4598 3 ปีที่แล้ว

    Sir aapka video bahoot hi achha rhata hai aur banaiye video plz plz

  • @subhashelect
    @subhashelect 3 ปีที่แล้ว +1

    very Very Importance point for the High voltage Switch Gear

  • @ameerkolambalam2670
    @ameerkolambalam2670 2 ปีที่แล้ว

    Sir iam diploma apprenticeship in pgcl and wait for next video

  • @surajparkash1799
    @surajparkash1799 10 หลายเดือนก่อน

    Good explain with fine way

  • @surendrakverma555
    @surendrakverma555 3 ปีที่แล้ว

    Very good

  • @tusharwilson623
    @tusharwilson623 2 ปีที่แล้ว

    Very nice explanation

  • @premasekharramanathan4364
    @premasekharramanathan4364 6 ปีที่แล้ว

    Thank you very much , please post such practical videos

  • @soumyaranjanmohanty9431
    @soumyaranjanmohanty9431 6 ปีที่แล้ว +5

    DEAR SIR , Let me introduce my self as a protection engineer ,working for Schneider electric. Sir I got from your video that how I can know whether it is a +ve or -ve DC earth fault. As DCDB provide DC voltage to all required ckt(i.e C&R panels, CB ckt.) . So how can I easily trace out that particular ckt. where the earth fault occur so that I can make my system normal?

    • @NiteshKumarElectrical
      @NiteshKumarElectrical  6 ปีที่แล้ว

      Thanks Mr.Sumya ! I am happy that you learnt from my videos ! keep it up ! all the best for your technical enhancement ;)

    • @rajkishan1799
      @rajkishan1799 5 ปีที่แล้ว

      Bhai koi vacancy hai kya

    • @sadaqatali9166
      @sadaqatali9166 2 ปีที่แล้ว

      If you have answer plz share with me

  • @khareshkumar21
    @khareshkumar21 2 ปีที่แล้ว

    Thank you sir

  • @amitkumar-im3ji
    @amitkumar-im3ji 5 ปีที่แล้ว

    Sir i am diploma trainee in pgcil....and learning a lot from ur videos..thank u so much for uploading such videos.... please keep giving new videos and more information....😊 Want ur reply also.......

    • @NiteshKumarElectrical
      @NiteshKumarElectrical  5 ปีที่แล้ว +1

      Thanks for learning from my Videos Amit !👍 That's great !! PGCIL is a one of the best Organization to Work for electrical engineer. Keep on learning and serving Country !👍 I will be replying. Thanks 👍

    • @amitkumar-im3ji
      @amitkumar-im3ji 5 ปีที่แล้ว

      @@NiteshKumarElectrical sir really excited to know more about master trip relay and how it works... can u make a video over it....pls....

    • @NiteshKumarElectrical
      @NiteshKumarElectrical  5 ปีที่แล้ว

      Ok I will make.

  • @vikashkumargarg9453
    @vikashkumargarg9453 5 ปีที่แล้ว

    Awsame video sir ji

  • @ashoksinghbhati87
    @ashoksinghbhati87 6 ปีที่แล้ว

    Very nice concept sir. Please carry on.
    Thank you

  • @alamzeb6342
    @alamzeb6342 6 ปีที่แล้ว

    Dear its been great effort you made, we really appreciate your this effort.

  • @bharattiwariwireman2674
    @bharattiwariwireman2674 6 ปีที่แล้ว +1

    Sir, Ac supply me bhi earth folt ko isi prakar ham jan sakate hain? Kya yahi process AC me bhi hota hai?

  • @Devendrakumarpankaj
    @Devendrakumarpankaj 29 วันที่ผ่านมา

    Thanks

  • @yogeshkumar8659
    @yogeshkumar8659 6 ปีที่แล้ว

    Awesome way of practical

  • @mdmanzarali9117
    @mdmanzarali9117 6 ปีที่แล้ว

    Very smart explanation

  • @dipanjandas9463
    @dipanjandas9463 6 ปีที่แล้ว

    Thank you sir. After identify how to solve this earth fault. 1Q. What is float charging & Boost charging and for 10 KW dc motor what capacity of battery bank required? Please explain.

  • @khan_tanzeem0521
    @khan_tanzeem0521 2 ปีที่แล้ว

    So in the case above are we further going to trace the positive earth fault identified or look for loose connection at the MCB for rectification please explain? (Enjoyed watching your video)

  • @asifkhokhar9331
    @asifkhokhar9331 3 ปีที่แล้ว

    Thank you

  • @pratikbhatt95
    @pratikbhatt95 5 ปีที่แล้ว

    Nice bro... I saw many of your videos, u have good knowledge and also u can explain very well. Best wishes, keep making more and more videos, our youth needs confusion free knowledge as u giving...👍

  • @smrutijitsatapathy7317
    @smrutijitsatapathy7317 6 ปีที่แล้ว

    Super class sirji

  • @satheeshkumar3977
    @satheeshkumar3977 6 ปีที่แล้ว

    Good

  • @punamchand4059
    @punamchand4059 6 ปีที่แล้ว

    बहुत-बहुत धन्यवाद

  • @sumittiwari327
    @sumittiwari327 3 ปีที่แล้ว

    Sir kya multimeter se DB panel ki earthing check Kar Sakte hai? Uspar ek vedio bna dijiye

  • @vinaykushwaha2380
    @vinaykushwaha2380 5 ปีที่แล้ว

    Too much good explanation bhai

  • @uddipansarkar90
    @uddipansarkar90 6 ปีที่แล้ว

    Nitesh ji agar earth fault nahi hota toh +ve to gnd and -ve to gnd kitna voltage ana chahiye tha??

  • @DeadSr851
    @DeadSr851 4 ปีที่แล้ว

    Well guidance thank you

  • @raytech6049
    @raytech6049 2 ปีที่แล้ว

    We do service all these digital meters in Kolkata with best accuracy 👌 .

  • @AmitThakur-yl9kr
    @AmitThakur-yl9kr 6 ปีที่แล้ว

    Thanks for your explanation...

  • @solarinstallationsbyaman7252
    @solarinstallationsbyaman7252 2 ปีที่แล้ว

    good

  • @DevD1111
    @DevD1111 6 ปีที่แล้ว

    Hello sir- very informative video. Ek acchi grounding k liye neutral and ground k bich m kitna voltage hona chaiye.

  • @alienvaigyanik5470
    @alienvaigyanik5470 ปีที่แล้ว

    Sunder

  • @erajaykumarv8755
    @erajaykumarv8755 6 ปีที่แล้ว +1

    Thank you for your information

  • @kanimran9285
    @kanimran9285 6 ปีที่แล้ว +1

    Good explain. ......

  • @dharmedradharuka9540
    @dharmedradharuka9540 5 ปีที่แล้ว +1

    Good thank you sir

  • @sanjeevreddy4811
    @sanjeevreddy4811 6 ปีที่แล้ว +3

    Bihar ka Sher...

  • @ShubhamYadav-mu6go
    @ShubhamYadav-mu6go 6 ปีที่แล้ว

    thank u sir.
    sir power factor ko lekar bahut confusion h iske baare Me detail se bataiye plz.

  • @DeepakMishra-js8ed
    @DeepakMishra-js8ed 5 ปีที่แล้ว

    u r superb sir

  • @shashanksinha2593
    @shashanksinha2593 6 ปีที่แล้ว

    It's helpful for me thks...

  • @mix_videos_islamic_knowled4804
    @mix_videos_islamic_knowled4804 3 ปีที่แล้ว

    Nice info

  • @boloharekesaharekejaijai4003
    @boloharekesaharekejaijai4003 6 ปีที่แล้ว

    You are great Sir

  • @himanshurana2181
    @himanshurana2181 6 ปีที่แล้ว

    Than you sir for this help

  • @umeshsarma53
    @umeshsarma53 6 ปีที่แล้ว

    Nitesh sir mene apne ghr me mcb 63 amp ka lga rkha tha Havells ka ,or aaj rccb lgaya 40 amp ka Siemens ka, kyunki ghr ka load km h . Jese ki mcb pehle lgta h or uske baad me rccb thik vese connection jb kiye to rccb ekdum trip ho ja rha h jese hi me koi fan load ya refrigerator load on krta hu ...Lekin jb mcb. (63amp. D.P.) ko rccb k baad lgaya to rccb normal work kr rha h ...ab mujhe ye btaaye ki ye connection shi ese hi rehne de ya fir rccb(40amp.) mcb (63amp. D.P) k baad lgaye.
    And Jo mcb single pole k lge h vo 10 amp or 16 amp k h lekin jb me wire daal k socket se short kia to mcb trip hi nhi hota blki socket burn hone lg gyi. Plz suggest me some good idea

  • @kalyankings2218
    @kalyankings2218 2 ปีที่แล้ว

    Tq boss

  • @bilalzinda3541
    @bilalzinda3541 6 ปีที่แล้ว

    helo brother kya hal hay ye pochna tha k ht volt kitni dori say noqsan karty hay matlab kitny volt par kitni dori say ap kam kar sakty plz reply kijey GA thanx

  • @sharadtiwari755
    @sharadtiwari755 3 ปีที่แล้ว

    Sir Mujhe multimeter purchase karna h..Substation k battery PM k kiye to kaunsa Multimeter lena hai ?

  • @bartamo3766
    @bartamo3766 3 ปีที่แล้ว

    Sir, suppose there is a damage to few 2volt cells of the battery bank of 110volt battery system of dc supply. Can i remove say six cells and add a 12volt lead acid battery available for home inverter from market and add in series as an emergency. Will it have any consequences?

  • @satnam7namsingh158
    @satnam7namsingh158 5 ปีที่แล้ว

    Good video

  • @darwint4065
    @darwint4065 2 ปีที่แล้ว

    Good potential value positive to earth ? Negetive to earth ?

  • @sajidabbas73
    @sajidabbas73 ปีที่แล้ว

    sir one q.
    what is panel waring

  • @mohammednazeeruddin5931
    @mohammednazeeruddin5931 6 ปีที่แล้ว +2

    How to trace and rectify this ground fault?

  • @technicalexperience2785
    @technicalexperience2785 4 ปีที่แล้ว

    accha hain

  • @user-ej1bv8rp4n
    @user-ej1bv8rp4n 5 หลายเดือนก่อน

    what is the procedure to solve the +ground fault? if u have any video plz give me the link

  • @ajayrai129
    @ajayrai129 3 ปีที่แล้ว

    Please provide information regarding what voltage values will be obtained when there is no earth fault..

  • @arpengoyal3051
    @arpengoyal3051 6 ปีที่แล้ว

    Bhai..substation me jitne b equipments hote h unki selection kse krte h??? oske upper koi video bna do..plxZzz bhai

  • @shivkumarchaturvedi5619
    @shivkumarchaturvedi5619 4 ปีที่แล้ว

    Please explain why 50% potential found wrt. Ground in isolated dc control supply system

  • @erajay2010
    @erajay2010 4 ปีที่แล้ว

    Sir please btaiye kya shut down liye bina hum particular section ko one by one isolate kr ke means uska ckt disconnect kr ke (DCDB se) dc leakage test kr skte h

    • @NiteshKumarElectrical
      @NiteshKumarElectrical  4 ปีที่แล้ว

      SOP ke anusar to shutdown lena hi chahiye. Bina shutdown ka koi bhi allow nahi karega aisa karne ke liye.

  • @uuuu2843
    @uuuu2843 5 ปีที่แล้ว

    Thank you bro

  • @aurobindamohapatra2768
    @aurobindamohapatra2768 6 ปีที่แล้ว

    Sir thank you, sir ekk ratings ke bare me ekk video banao

  • @sanjaykumar-es9wl
    @sanjaykumar-es9wl 6 ปีที่แล้ว +1

    Bhai cable Megger kaise karte hai ... Ek video us par bhi. Urgent chahiye tha

  • @siyaramrathore6722
    @siyaramrathore6722 4 ปีที่แล้ว

    Sir please aap ek 415 V ac to 220 V dc battery charger per ek video banaiye

  • @shyara_parth
    @shyara_parth 6 ปีที่แล้ว

    hello.sir.agar positive and negative dono me EF nahi hoto to dono k bich me kitana voltage show karega?...

  • @anoopverma3912
    @anoopverma3912 6 ปีที่แล้ว

    Nice sir

  • @iswarmahanta6905
    @iswarmahanta6905 5 ปีที่แล้ว +1

    Why 220 v dc supply half between ph to ground..? Please sir fundamental clear...?

  • @parvezahmadaimim5780
    @parvezahmadaimim5780 5 ปีที่แล้ว

    sir batye to hame samjhe me aya

  • @ketankhairnar3320
    @ketankhairnar3320 6 ปีที่แล้ว

    Nice dar

  • @mdnadeemhussainansari6770
    @mdnadeemhussainansari6770 6 ปีที่แล้ว

    nice sir

  • @MaheshKumar-dn9gn
    @MaheshKumar-dn9gn 6 ปีที่แล้ว

    Super sir

  • @harishaharisha3707
    @harishaharisha3707 4 ปีที่แล้ว

    Sir please speech merger testing

  • @asthalalakimasti1989
    @asthalalakimasti1989 6 ปีที่แล้ว +1

    Dear sr
    Positive aur negative me 220 v dikhata hai lekin positive me earth se +110 v dikhata hai neg me -110v dikha hai aisa kyo kyo nhi +220 aur - 0 dikhata

  • @sanambuet2721
    @sanambuet2721 6 ปีที่แล้ว

    Nitesh brother, can you please provide the video on protection scheme design which you explained earlier but now i can't find them. please

  • @brijendraswaroop9963
    @brijendraswaroop9963 6 ปีที่แล้ว

    Good evening sir

  • @sagartrivedi7168
    @sagartrivedi7168 3 ปีที่แล้ว

    Sir ager positive or negative dono me earth fault ho to?

  • @pankajbehera8461
    @pankajbehera8461 6 ปีที่แล้ว

    Sir Us wire ground Kahan hua hai kese pata chalega I mean us mcb Ko kholenge ya kuch aur method hai

  • @RamaKrishnan-hx4ui
    @RamaKrishnan-hx4ui 4 ปีที่แล้ว

    Sir mujhe ek bat samaj nahi aya wt r the advantage to ground the +ve , if the +ve shorted to the earth how can we getting the voltage.

  • @adithihomeplant3661
    @adithihomeplant3661 3 ปีที่แล้ว

    We r switch one by one feeder dc supply .but it's fault in battery charger how to check fault sir.

  • @SimajNewsonline8626
    @SimajNewsonline8626 5 ปีที่แล้ว

    Nice

  • @mdmanzarali9117
    @mdmanzarali9117 6 ปีที่แล้ว

    Pls make one video on oil filtration of transformer

  • @saidurrahman2662
    @saidurrahman2662 5 ปีที่แล้ว

    thanks sir

  • @parthaproteemroy9742
    @parthaproteemroy9742 6 ปีที่แล้ว

    I want to know what about Telecom Systems where we need negative voltage where the positive is grounded in order to give negative voltage to the systems

  • @nhattru3195
    @nhattru3195 5 ปีที่แล้ว

    Thank sir, I have question, At power house, DC system display fault: Battery Earth Fault, How do check faul? Thank you!

    • @NiteshKumarElectrical
      @NiteshKumarElectrical  5 ปีที่แล้ว

      Watch this Video. I have uploaded today to answer your questions. th-cam.com/video/auwNwBGX744/w-d-xo.html
      This is in English language. If you want to watch in Hindi then link is given in the description box of this video. Or search in my channel. Thanks.

  • @csgupta7017
    @csgupta7017 3 ปีที่แล้ว

    In some cases either positive or negative is grounded . If positive is grounded then how can we detect earth fault between negative and earth?

  • @abdullahkhan4020
    @abdullahkhan4020 6 ปีที่แล้ว

    Nice g

  • @ZahidHussain-wk1zl
    @ZahidHussain-wk1zl 5 ปีที่แล้ว

    How do I test a transformer differential relay slope, high sets?
    Please explain..

  • @manojshukla3598
    @manojshukla3598 6 ปีที่แล้ว

    sir provide any source for understanding relay setting of Siemens ,abb ,and easun relay as well as motor protections

  • @jyotirmoysahoo1024
    @jyotirmoysahoo1024 5 ปีที่แล้ว

    Sir Relay k barame Kuch video banaye

    • @NiteshKumarElectrical
      @NiteshKumarElectrical  5 ปีที่แล้ว

      Hi jyoti, aap mere channel pe sabhi video ko dekh lo, usme jo achha lage aap dekh sakte ho. relay ke bare me bhi maine video banaya hai. usko dekho.
      th-cam.com/channels/B3y6-CYWtZEf5JYLND06oA.html

  • @nerldcshillong2272
    @nerldcshillong2272 4 ปีที่แล้ว

    Can you please give me the value of capacitance of dc positive to Earth or negative to Earth (of your substation)

  • @VIKRAMSINGH-eo1lo
    @VIKRAMSINGH-eo1lo 3 ปีที่แล้ว

    If there is a minor difference between positive - Earth and negative Earth voltage then DC is leakage anywhere or not.If leakage then how we find out at which point DC Leakage and we can short it.Plz explain..

    • @NiteshKumarElectrical
      @NiteshKumarElectrical  3 ปีที่แล้ว

      You would have got some idea by watching this video. Concept is same only. However I will explain in a separate video about your concern. Thanks.

  • @aamirawan7998
    @aamirawan7998 3 ปีที่แล้ว

    What if there was no ground fault? What will be the voltage then between positive and ground and also negative and ground?

  • @ersachinsaini2064
    @ersachinsaini2064 4 ปีที่แล้ว

    Ab earth fault ko trace kaise karoge jabki cable to sab jagah ja rhi ho underground and through chanel or congested area .....that u know what I am asking...
    Plss reply

    • @NiteshKumarElectrical
      @NiteshKumarElectrical  4 ปีที่แล้ว

      Video me maine bataya hai na trace karne k liye. Alag alag circuit ko pahle identity karo ki kis me hai. Uske bad trace hoga scheme ke according.

  • @dinabandhukhuntia9077
    @dinabandhukhuntia9077 2 ปีที่แล้ว

    How we get voltage reference to earth where battery is not grounded.you only get voltage from +ve to- ve value.
    So you must describe the middile point earhing first.

  • @sadaqatali9166
    @sadaqatali9166 2 ปีที่แล้ว

    How we find exect location of DC grounding

  • @erajay2010
    @erajay2010 4 ปีที่แล้ว

    Sir can I connect Galvanometer with the dc Circuit to check dc leakage? So that if there is any leakage, Galvanometer must deflect.

  • @sadaqatali9166
    @sadaqatali9166 2 ปีที่แล้ว

    How i find DC lekeage in grid station system

  • @LifEoFaSaiLor2022
    @LifEoFaSaiLor2022 5 ปีที่แล้ว

    EARTH FAULT NI HOTA HAI TOH POSITIVE AND GND AND NEGETIVE AND GND K BICH KITNA HOTA HAI?HEALTHY CONDITION ME I MEAN

  • @KarmaRangdroelThaye
    @KarmaRangdroelThaye 5 ปีที่แล้ว +1

    hello sir, if you could explain in English, its far better to understand for those who are language problem.

    • @NiteshKumarElectrical
      @NiteshKumarElectrical  5 ปีที่แล้ว +1

      *Hi Karma ! Thanks for feedback but I used to make videos in both Language Hindi & English. You may check list of videos on my channel. I do understand this, My viewers are from Glob and basically it's technical so I make video in both language on same topic and upload at the same time. Thanks*

  • @mukeshghodakiya8839
    @mukeshghodakiya8839 6 ปีที่แล้ว

    mere substation ke battery charger me earthlikage ka indications aa Gaya hai. kese find out karna padega sir?

  • @chrisraj7513
    @chrisraj7513 5 ปีที่แล้ว +1

    Dear sir, I am from tamilnadu . So please explain english also . Open new english channel and give that link sir

    • @NiteshKumarElectrical
      @NiteshKumarElectrical  5 ปีที่แล้ว +1

      th-cam.com/channels/B3y6-CYWtZEf5JYLND06oA.html
      Go through this. You will get my english videos also. I make video in two language on same topic. And upload at the same time. Thats my old video. Thanks.

    • @chrisraj7513
      @chrisraj7513 5 ปีที่แล้ว

      Thanks sir