Trane Furnace and Air Conditioner Installation by A Plus Air Systems

แชร์
ฝัง
  • เผยแพร่เมื่อ 28 ส.ค. 2024
  • HVAC Installation by
    A Plus Air Systems Inc.

ความคิดเห็น • 435

  • @edsonsilvadacostasilvadaco5246
    @edsonsilvadacostasilvadaco5246 2 ปีที่แล้ว +101

    *Love this unit! Using upstairs in my sons bedroom **Fastly.Cool** and he’s finally able to be comfortable upstairs without me freezing downstairs. Works for more sqft than expected!*

    • @user-ln7of9gs4s
      @user-ln7of9gs4s 2 ปีที่แล้ว

      What are you talking about? I keep reading the same comment on multiple videos. You’re using a gigantic unit in your sons bedroom? Is it 4 tons?

  • @IvanStarling-kg1ei
    @IvanStarling-kg1ei ปีที่แล้ว +26

    Purchased: August 2023 - still works GREAT!I th-cam.com/users/postUgkxxsUnXhGsSJLim_XnMHyQK0u3XVaW-CGn live in a studio and during the summer it gets scorching hot - really old building with no ac units. I can’t express how EASY it was to install. This unit has been a life savior during the summer and some days during other seasons where it can still be a bit warm at night. In this small place is my friend, a husky, poodle mix and myself. We need AC - lolI don’t use the dehumidifier option - I’m not sure if it will leak in my house, since I did not install the small draining hose that came with it. May look into it late but I don’t worry about much humidity in the apartment. I don’t understand why the negative reviews since all things mentioned, I personally did not find issues with. Definitely worth it!

  • @tom-dr1ym
    @tom-dr1ym 6 ปีที่แล้ว +39

    nice when you have all that room to work

    • @ihysnxgs4014
      @ihysnxgs4014 3 ปีที่แล้ว

      Ikr

    • @xen9254
      @xen9254 3 ปีที่แล้ว

      @Roland Harlem Yeah it really does work! You guy should try it because these guys are definitely not trying to screw you over!! 💀

    • @leave_it_to_levi1652
      @leave_it_to_levi1652 3 ปีที่แล้ว

      Haha out here in California (Bay Area) we literally never have anything that spacious , that would be like heaven

  • @TheChurchofCacti
    @TheChurchofCacti 9 ปีที่แล้ว +9

    This is the field I'm getting into. Just finished my first year of a two year program. Next fall I'll graduate with my Associates degree in applied science and certification in RAC. Most of the things they did in this video I understood what they were doing, but some of the things we haven't done yet. For instance we haven't covered central air or duct work at all. Pretty much we've only gone over the four basic components, how the system actually works\cools, electrical, charging, recovering, soldering, leak detection, and stuff like that. I feel like we haven't done enough hands on work though so hopefully once I graduate and start working I get a good mentor to show me the ropes.

    • @TheChurchofCacti
      @TheChurchofCacti 9 ปีที่แล้ว +4

      hope less
      That's actually my goal. Both my parents own small businesses and will help me invest in myself when I'm ready. I plan to work under someone for a company to really learn what I need to know for a few years and then go out on my own.

    • @summitm18hvac90
      @summitm18hvac90 5 ปีที่แล้ว +1

      College doesn't teach u hardly anything. I went to school, was a 2 year program. I went for 1 and got my certificate and 608 license. When out in the field it's a whole different beast. Been doing hvac since 2013. Best of luck bro. Either wanna do this trade or dont. Can't fake it

    • @jacekburghardt2858
      @jacekburghardt2858 2 ปีที่แล้ว

      After 7 years I hope you are still in field how was your experience.

  • @oneshotofvodkaa3973
    @oneshotofvodkaa3973 4 ปีที่แล้ว +1

    You guys are lucky installing in basements. I have to install theses in hot attics in the summer. Trane Comfort Specialist from Inland Empire and North County CA.

  • @noahgibson482
    @noahgibson482 4 ปีที่แล้ว +6

    Nice when you have that many people on an install, our crew is usually me and one other guy

  • @newstart49
    @newstart49 4 ปีที่แล้ว +6

    46 years in this business (And also a Trane dealer), and I can say it looks like you did a very good job.
    My two concerns would be that the service access at the heat pump should be away from the wall to make it easier to work on. The other is the mount to the wall. I would be ok with it if I knew the mounting bolts were attached to the walls studding and not just the brick- brick is not that strong. I may have provided two footholds on the lee side.
    I always install the 4-5" filter systems. When I return to do the yearly/annual maintenance, I bring the filter with me- the customer never has to mess with filters ever again.

    • @dadefope80
      @dadefope80 4 ปีที่แล้ว

      I was thinking the same thing. If a tech had to come out and replace anything on that heat pump, he or she will be cussing to high heaven.

    • @bradyharbison7521
      @bradyharbison7521 3 ปีที่แล้ว

      @@dadefope80 not a heat pump

    • @dadefope80
      @dadefope80 3 ปีที่แล้ว

      @@bradyharbison7521 The Condenser, then

  • @toemblem
    @toemblem 4 ปีที่แล้ว +4

    There are a lot of things that I would have done differently but I will restrict my comments to the condenser install. First, I would have secured that slab to the bracket and then the unit to the slab. Second, I would have rotated it 90 degrees so that it would be serviceable. It looks clean all tight to the wall but someday, you'll need to change a contactor or capacitor.

    • @toemblem
      @toemblem 4 ปีที่แล้ว

      Come to think of it, they have a gas FAU for heating, why does that AC need to be mounted? They wouldn't be running it when it snows. Right?

  • @jonyboi69
    @jonyboi69 8 ปีที่แล้ว +5

    Good job on installing the system that's how all business should be, prefesional and neat workmanship. Although I did see some issues no nitro flowing when brazing, when sleaving the suction line protect opening from powder entering copper. Also when touching any electrical circuits must bring up to code, like the disconnect I seen that you forgot to reidentify the line side of the disconnected to hot. Just giving my opinion. Other than that great job!

  • @Jets-and-airconditoning
    @Jets-and-airconditoning หลายเดือนก่อน

    Dang that’s heavy as hell but that’s a really good high performance unit it’s one of the best units out there!

  • @fattony123082
    @fattony123082 10 ปีที่แล้ว +7

    I somewhat enjoy commercial hvac because 90% of the time it's a packaged RTU on a roof out of the way of a customer. Looking good in this install guys, but may I recommend purging lines with nitrogen during brazing. Less call backs know what mean. Keep up the good work

  • @1970brewcrew
    @1970brewcrew 11 หลายเดือนก่อน

    I liked the guy outside wearing shoe coverings

  • @d.hansel854
    @d.hansel854 3 ปีที่แล้ว +1

    I had a Bryant central air. When it went out my HVAC contractor talked me into an Amana system. He told me it had a lifetime warranty. About 8 years later the compressor when out. He told me no problem and brought me a brand new one, no charge.
    I called Amana which is made by Goodman air conditioner company here in Houston and ask them if they still give lifetime warranty on their units. They said anything with a 16 SEER rating and above.
    They said in the future if it goes out just let the HVAC company know and they will replace the unit FREE !
    You can't beat a deal like that.

    • @edwardburnsburns5307
      @edwardburnsburns5307 3 ปีที่แล้ว

      Amana Bought goodman and yes it is a good deal but not the best system you can buy , they also now are with Daikin and they make the Daikin fit system and that is the best system made today no other can do what that one can , i am happy to hear you are happy with your Amana , They went all out on that system so you made a good choice

  • @nuestrodestinowr
    @nuestrodestinowr 5 ปีที่แล้ว +32

    Why some people leave the electric side facing to the wall? ...
    I always leave the electric side facing out for future repairs...
    More room make it easier

    • @pbialpha2911
      @pbialpha2911 4 ปีที่แล้ว

      Lol yeah leave the wires out and fail inspection

  • @LongTrout
    @LongTrout 3 ปีที่แล้ว

    Nice install....It always help when the original was quality as well....

  • @twittyk78
    @twittyk78 7 ปีที่แล้ว +2

    i really like how the service panel is in a corner that will be fun to access ,way to think about your service guys installers !
    cool jump w1 and 2 instead of selling a better stat or running wire

    • @noone3690
      @noone3690 4 ปีที่แล้ว

      Yup. New install should have a new stat. Just asking for trouble later on.

  • @loganlawless2098
    @loganlawless2098 5 ปีที่แล้ว +51

    Installers never think about the tech that has to come and fix it down the line.

    • @MrGlen6911
      @MrGlen6911 4 ปีที่แล้ว +1

      Logan Lawless down the line I give it 3 days maybe 5

    • @javierpineda3365
      @javierpineda3365 4 ปีที่แล้ว

      Half t

    • @alyssatrujillocookingshow2853
      @alyssatrujillocookingshow2853 4 ปีที่แล้ว

      Did anyone else catch the flue length ? Didnt it seem long for 2 inch. Also did he put it on a vacumm well the other side wasn’t brazed in?

    • @RonaldRegan314
      @RonaldRegan314 4 ปีที่แล้ว

      @@alyssatrujillocookingshow2853 ?.. taking out the fact that that flu looked like it did not have proper grade, the length looks fine, that is assuming it's a 100kbtu and altitude from 0-2000, taking all his 90s and 45s he has about 50' of length to work with. But that's assuming it's 100kbtu. If it's less then he has much for footage to work with.

    • @edwardburnsburns5307
      @edwardburnsburns5307 3 ปีที่แล้ว

      but 100 screws makes me a better installer because i screw my ductwork on the bottom of all my jobs and then I pull my coil out and screw it down under there too ,, when im done with that I jump up and down on my 4 foot pipe wrench to make my gas pipe tight so no one can get it apart , then i do shit like pull the blower out of the air handler and screw it to the wall behind it with 3 inch screws so it doesn't fall over and last but not least I cut tabs in my furnace so when i put the coil on it I can crew those tabs into the coil box and i always make sure i do two in the back and cover it with tape and mastic then slide it into a closet and screw it to the wall and put the coil back in so it doesnt fall up , that makes me a good installer because when i install something it never needs to be replaced later on, because i used 100 screws !! LOl

  • @thomaspease208
    @thomaspease208 7 ปีที่แล้ว

    loved they respected that lady's home by putting down the tarp and hospital style foot ware

    • @mofoshizknack
      @mofoshizknack 4 ปีที่แล้ว

      Thomas Pease they’re just trying to get down her pants

  • @fernandoprieto2865
    @fernandoprieto2865 5 ปีที่แล้ว +3

    The guy sweeping at the end cracked me up.

    • @mofoshizknack
      @mofoshizknack 4 ปีที่แล้ว

      Fernando Prieto only bitches sweep

    • @cheapandeasy1715
      @cheapandeasy1715 3 ปีที่แล้ว

      @@mofoshizknack So...how long you been sweeping now?

    • @mofoshizknack
      @mofoshizknack 3 ปีที่แล้ว

      @@cheapandeasy1715 I never sweep or wash dishes.

  • @williammarik6159
    @williammarik6159 3 ปีที่แล้ว +2

    I cant believe that old condenser did not spew oil all over that nice sidewalk with that oaf rolling it around like that.

  • @JulesODwyer
    @JulesODwyer 5 ปีที่แล้ว

    A lot of negative comments,I think the Nitrogen Purge of line sets is about the only negative comment I agree with but overall a very good clean job.From Louisiana been in a/ c trade for 45 plus yes and I think you guys did an overall good job.Listen if I was to critique everything on a job it would never end,so give the guys a break overall good job

  • @FrostBlueFire
    @FrostBlueFire 5 ปีที่แล้ว +10

    From every service repair tech who comes after this, "fuck you"
    Service access is facing in a place a service tech would have to struggle to just even look at, not to mention no nitrogen flow, microngauge is needed. Air is probably in the system, smh.
    If you ask me, half assed job, this isn't A+.

  • @jimbola77
    @jimbola77 8 ปีที่แล้ว

    looks like a nice install, I'm trying to get my foot n the door as a tech helper etc... I know it takes time practice makes u better you will alway's be learning in this field thing's keep changing never boring I drive OTR it's tiring i'm trying to get enough under my belt to switch career's!!! thank's for sharing good video and customer relation's!!!

  • @texasmade2684
    @texasmade2684 10 ปีที่แล้ว +7

    Looked like a real good job very professional. The only thing I noticed you didn't have a micron gauge when you pulled the vacuum.

    • @bigt5917
      @bigt5917 5 ปีที่แล้ว +1

      To hell with a micron guage .
      All of you new kids on the block think you have to have one. Guess what you dont.

  • @ECWnWWF
    @ECWnWWF 4 ปีที่แล้ว +2

    the explanations of why they are doing what they are doing is high quality

  • @camel8687
    @camel8687 4 ปีที่แล้ว +3

    i never though of using interior caulk for exterior masonry. what a good idea

  • @mychoclabwinston
    @mychoclabwinston 5 ปีที่แล้ว

    Wow a trance tech not actually mounting the disconnect to the electrical cover, I’m impressed😂

    • @macattack583
      @macattack583 5 ปีที่แล้ว

      its not code to connect it to the cover as long as it is reachable.

  • @elnownetwork
    @elnownetwork 5 ปีที่แล้ว +2

    Doing vacuum to the basement... nice work guys love it

    • @noone3690
      @noone3690 4 ปีที่แล้ว

      I’m hoping the outside was the full start to finish and then when they went back in they showed it’s complete install. Surly they didn’t vacuum without coil hooked up but who knows!

  • @zebragozt5284
    @zebragozt5284 7 ปีที่แล้ว

    You guys do have a hard job, work well done.

  • @Khaltazar
    @Khaltazar 4 ปีที่แล้ว +27

    Did they really just set a pad on top of wobbly brackets with no support and then set a heavy A/C unit on top of that? Wow... that is asking for trouble later on... if any of those brackets rust, bye bye unit. It won't survive a bump test either. Is that really standard? Every unit I see is always on the ground on a concrete slab or heavily supported with material that won't rust. They could of added some additional support under the unit to make it more stable.

    • @darrenfitzgerald8354
      @darrenfitzgerald8354 3 ปีที่แล้ว

      Trane makes heat pumps that can go on a mount this is not one of them.

  • @jasoncurtis4404
    @jasoncurtis4404 5 ปีที่แล้ว

    Me and my partner would do that entire changeoutnin about 4-5 hours. Just the 2 of us. Perfect quality install.

    • @JunaydShakur
      @JunaydShakur 5 ปีที่แล้ว

      I’m in Fort Lauderdale. Takes me 4 hours to change out system solo.

  • @getgetoutout
    @getgetoutout 2 ปีที่แล้ว +1

    Why no Nitrogen when brazing the line set?

  • @rossr4222
    @rossr4222 6 ปีที่แล้ว +2

    Big boy struggled taking that ac off the brackets LOL. Probably pooped his pants

    • @mofoshizknack
      @mofoshizknack 4 ปีที่แล้ว

      Ross R No Shit, probably farted out a condom

  • @albertaproud7855
    @albertaproud7855 3 ปีที่แล้ว +1

    Didn’t see you boys drop a chimney liner down for that water heater...

  • @amesavis
    @amesavis 4 ปีที่แล้ว

    would not expect an indian in such a cold clime but they seemed very professional

  • @jacksonvilleairductcleanin1478
    @jacksonvilleairductcleanin1478 5 ปีที่แล้ว

    Good informational video on your company

  • @Grizbox
    @Grizbox 10 ปีที่แล้ว

    this video is awesome, its editing is perfect for learning.

    • @MrGlen6911
      @MrGlen6911 4 ปีที่แล้ว

      Clintopoulos Grizworld learning what not to do I agree

    • @edwardburnsburns5307
      @edwardburnsburns5307 3 ปีที่แล้ว +1

      you want to lear watch grey furnace man , best hvac learning videos on youtube

  • @ipfreely1281
    @ipfreely1281 7 ปีที่แล้ว +1

    Good job guys thanks for posting I enjoyed it brought back memories

  • @yoellopez82
    @yoellopez82 7 ปีที่แล้ว

    that trane looks beautiful

  • @johne153
    @johne153 5 ปีที่แล้ว +1

    4:48 lmaooo idk why but seemed hilarious like the office or parks and rec. perfect video and then THUD lol

    • @carsonp.7009
      @carsonp.7009 4 ปีที่แล้ว

      yeh lmao and the zoom in just like one of those shows

  • @ashtonpollard3556
    @ashtonpollard3556 9 ปีที่แล้ว

    those guys..worked like professionals...they seek complete customer satisfaction

  • @rossr4222
    @rossr4222 6 ปีที่แล้ว +7

    Furnace and cased coil+transition is already in and big boy is still ripping out the old line set? Fired!

  • @MicheIIePucca
    @MicheIIePucca 9 ปีที่แล้ว

    Great rare video to find... and very well done. Thank you!

  • @cpapwor1
    @cpapwor1 10 ปีที่แล้ว +3

    Nice job. I only had one issue. I didn't like the condenser access panel facing the wall. Looks nice, but a pain in the ass to service or replace components.

  • @Milerhighlife2011
    @Milerhighlife2011 5 ปีที่แล้ว +17

    I never once saw a recovery machine or recovery tank maybe this system is empty who knows was it explained in the video also there once all nitrogen mean used brazing or never saw a micron gauge hook up to the system yeah not the way you do it

    • @JunaydShakur
      @JunaydShakur 5 ปีที่แล้ว +4

      As long as the system pumps down there’s no need to recover the refrigerant.

    • @toemblem
      @toemblem 4 ปีที่แล้ว +1

      Let's assume that they recovered the refrigerant properly so we don't have to worry about that. I agree. How did he know that he had pulled a proper vacuum? I do like how they changed the line set though. I assume they were going from R-22 to R-410A. Whenever possible, I would recommend changing the lineset.

    • @Jon-hx7pe
      @Jon-hx7pe 4 ปีที่แล้ว

      single stage thermostat/wiring on 2-stage furnace too! No commissioning shown.

    • @edwardburnsburns5307
      @edwardburnsburns5307 3 ปีที่แล้ว

      you are right sloppy work leads to call backs

  • @zeke112964
    @zeke112964 9 ปีที่แล้ว +18

    How do you pull a vacuum on the line set (14:08 minute mark) before its connected to the evaporator coil?(15:30 mark)

    • @lawrenceyoung9445
      @lawrenceyoung9445 8 ปีที่แล้ว +2

      I ask myself that too lol. I got a little lost there. I was expecting to seeing the vacuum at the end right before adding refrigerant

    • @elnownetwork
      @elnownetwork 5 ปีที่แล้ว +2

      Doing vacuum to the basement... nice work guys

    • @elnownetwork
      @elnownetwork 5 ปีที่แล้ว +1

      Doing vacuum to the basement... 500 microns love it ....nice work guys

    • @edgarh.5727
      @edgarh.5727 4 ปีที่แล้ว +2

      Think just a bad edit

    • @toemblem
      @toemblem 4 ปีที่แล้ว +1

      Had to be editing. But how do you pull a real vacuum without removing the schraders, using a 1/2" hose and a micron gauge so you know when you're done?

  • @henrym02
    @henrym02 7 ปีที่แล้ว +5

    am i missing something here? where is the trap for condensation line, and as you brace copper ,nitrogen has to run through

    • @josephschilcher7806
      @josephschilcher7806 7 ปีที่แล้ว +2

      You do not install trap in a positive pressure coil

    • @summitm18hvac90
      @summitm18hvac90 5 ปีที่แล้ว

      There should be a trap, I've put ez traps on my installs. No issues so not sure where got ur info

    • @bradw.5991
      @bradw.5991 5 ปีที่แล้ว

      Drain Traps are only required when City Code calls for it on a Positive Pressure system, all Negative Pressure systems require it for draining no matter if it has a Code or not.

    • @jasoncurtis4404
      @jasoncurtis4404 5 ปีที่แล้ว

      No trap required when coil on supply side. But in a basement, I always put ez trap.

  • @noone3690
    @noone3690 4 ปีที่แล้ว +1

    Did anyone see hangers for the pvc vents? If there was it wasn’t many. Should be every 3-4ft support hangers but maybe I missed them.

  • @tylertilghman7290
    @tylertilghman7290 5 ปีที่แล้ว +1

    This install would fail in a heart beat in Oklahoma... no secondary drip pan under the coil... no fall on the flue or fresh air for furnace... and don't get me started on why they fired up the a.c. on a day it's snowing... and I assume they charged the system on start up, so they'll be back in the spring to recover some of it...these guys are back jobs... I do a furnace, coil, line set, a.c., run a flue, and transition by myself in about 8 hours... and I have passed every inspection this last year...

  • @paulocac
    @paulocac 6 ปีที่แล้ว +1

    Gostei muito deste vídeo parabéns pela instalação

  • @kc6442
    @kc6442 ปีที่แล้ว

    @ 9:11, nice "kayak."
    👀

  • @johnperry1888
    @johnperry1888 10 ปีที่แล้ว

    Looks like a professional install that was very neatly done.

  • @erixgar4117
    @erixgar4117 6 ปีที่แล้ว +3

    What happening with the lineset filter?

  • @adriansoroa7514
    @adriansoroa7514 9 ปีที่แล้ว +1

    Hi, Guys congras for the video. The communication with customer and between you guys was good. The job was good except, you should have left a better access to be able to service the unit. To close to wall.

    • @summitm18hvac90
      @summitm18hvac90 5 ปีที่แล้ว

      I'm not defending these guys. But sometimes you don't have any other option but to be close like this job is. I've put plenty of installs in and had one job, recently, where it was barely accessible to service, but, I went over it with a service tech and he agreed, that was the only viable option.

  • @grtap
    @grtap 4 ปีที่แล้ว

    The old furnace was better than the one that they replaced it with.

  • @fattony123082
    @fattony123082 10 ปีที่แล้ว

    I really like to see the energy savings.

  • @ra8937
    @ra8937 7 ปีที่แล้ว

    Very professional. Great work gentleman.

  • @sawyerramos3113
    @sawyerramos3113 4 ปีที่แล้ว +1

    Im having an A/C installed tomorrow. 2 ton, $2600. Florida. 2020. You have to shop around and be careful with these "companies" with vans wrapped in "cute" designs. They are crooks!

  • @tonypalmer300atyahoo
    @tonypalmer300atyahoo 8 ปีที่แล้ว +2

    How much did it cost? Why didn't he shake the air conditioner condenser? Show the owner how unstable it was.

  • @Nyck461
    @Nyck461 9 ปีที่แล้ว +2

    The guys did a good job.

  • @crabjoe
    @crabjoe 9 ปีที่แล้ว +26

    Is it just me, or is the condenser a bit to close to the wall?

    • @zeke112964
      @zeke112964 9 ปีที่แล้ว

      +crabjoe Yes there are minimum distances from the wall

    • @nuestrodestinowr
      @nuestrodestinowr 5 ปีที่แล้ว +4

      Other than that...
      The electric part facing to the wall..
      No room for future repairs

    • @MrGlen6911
      @MrGlen6911 4 ปีที่แล้ว

      crabjoe yes 16” clearance on all sides but thats the least of my worries lmao

    • @oneshotofvodkaa3973
      @oneshotofvodkaa3973 4 ปีที่แล้ว

      I’m a Trane Comfort Specialist in CA. What Trane recommends is 12” from the wall. 12” being the minimum.

  • @Maverick-2202
    @Maverick-2202 8 ปีที่แล้ว +5

    the journeymen did a great job but his apprentices need work. the vents were done very sloppy with no supports every 4 foot and very sloppy with the glue. The sheet metal work was very nice and clean

    • @stubronson8718
      @stubronson8718 4 ปีที่แล้ว

      Yeah, his sheet metal work on site was on point

  • @TheAloneman91
    @TheAloneman91 9 ปีที่แล้ว +4

    I want to know how much for the complete installation included the central air conditioner.

    • @mofoshizknack
      @mofoshizknack 4 ปีที่แล้ว +3

      TheAloneman91 about 3fiddy

    • @1on1c5
      @1on1c5 3 ปีที่แล้ว

      This is around 15-18K US dollars. The XR model is decent.

  • @FlyEaglesFly19111
    @FlyEaglesFly19111 5 ปีที่แล้ว +1

    #1leave all boxes on equipment till as close to install location this will help for less scratches.. #2 get help..less damage to property of customer..#3 miter duct of return to center up better new equipment to supply duct. #4 learn how to make a hand make Pittsburg seam so less air loss on supply transition. #5 do job right and install new brackets for outdoor unit. #6 install outdoor to access electrical panel better. #7 dont let these guys install at your house. I could go on and on and on of just this install..wow these guys give the rest of us a bad name!!!!!

  • @Texarkanaacrepair
    @Texarkanaacrepair 8 ปีที่แล้ว

    Interesting video, nice work!

  • @biblebloopers946
    @biblebloopers946 3 ปีที่แล้ว

    Why would you install the electrical side and your refrigerant ports in the corner like that?

  • @enriquecalderon453
    @enriquecalderon453 6 ปีที่แล้ว +1

    I'm not here to criticize I'm here to learn from other people my suggestion is why not run copper line and electrical on other side to make more accessible for Servicing

  • @dollyjohnson28
    @dollyjohnson28 5 ปีที่แล้ว

    Good video , make more please!

  • @phillipdonohue5
    @phillipdonohue5 10 ปีที่แล้ว +22

    lol, what a cake install. Have you guys in Canada ever do a install in Arizona! haha you would quit the biz!

    • @blueg3027
      @blueg3027 5 ปีที่แล้ว +4

      wtf these hacks are from Canada. Well im embarrassed as shit. These dicks are not a representation of the trades in Canada lol at all

    • @Devilsfan-pd8ov
      @Devilsfan-pd8ov 5 ปีที่แล้ว +1

      Phillip Donohue Arizona lol Try a install in jersey

    • @summitm18hvac90
      @summitm18hvac90 5 ปีที่แล้ว

      It really was a cake install. 6 hours or less

  • @jasoncurtis4404
    @jasoncurtis4404 5 ปีที่แล้ว +1

    Lucky u not in an attic in the summer time with them hot ass shirts lol.

  • @garmin1488
    @garmin1488 4 ปีที่แล้ว

    Didn't see any purple primer used while gluing the 636. Not sure why you wouldn't replace the hot water tank with a power vent type. Looks like a bit of a hack job, this seems to be one of the shadiest trades out there. Not sure how big the house is but that AC looks massive, 3.5 tons?

  • @jamalchennoufi1765
    @jamalchennoufi1765 10 ปีที่แล้ว +1

    great job thanks guys.

  • @skiprope536
    @skiprope536 5 ปีที่แล้ว +5

    H A C K job!

  • @craigweisman4783
    @craigweisman4783 8 ปีที่แล้ว +32

    Why no Nitrogen purge during Brazing? Didnt see a vacuum guage to assure 500 micron vacuum. The intake pipe is below the average snow fall. A-Plus, I think Not

    • @benjamindanielson9747
      @benjamindanielson9747 8 ปีที่แล้ว +6

      most people don't do a nitrogen purge... and I've found its not necessary if you put pressure on the line before you put the Schrader valve back in after brazing... it'll blow everything right out anyways... just a preference I suppose...

    • @cjwise5552
      @cjwise5552 8 ปีที่แล้ว +2

      I don't understand how nobody understands the concept of the piping being above snowfall. It was even snowing as he was glueing the pipes

    • @consumersgasman8376
      @consumersgasman8376 7 ปีที่แล้ว +3

      intake has to be 12in above grade for Toronto area

    • @ryanalway4655
      @ryanalway4655 6 ปีที่แล้ว

      Craig Weisman hey Craig u seem like u have good wits in this field how much should it cost for a new air conditioning system if u have all ducts and vents in home already?

    • @giomongous
      @giomongous 6 ปีที่แล้ว +1

      Ryan Alway a system like this should cost no more than 10 thousand.

  • @mrcalifornia_7177
    @mrcalifornia_7177 3 ปีที่แล้ว

    nice video.

  • @kingcobra6149
    @kingcobra6149 8 ปีที่แล้ว +1

    I don't see any filter dryer near the coil or the condenser. There should be one to avoid any type of debris that's coming from the lineset.

    • @garrettnp5
      @garrettnp5 8 ปีที่แล้ว +1

      It's in the condenser

    • @benjamindanielson9747
      @benjamindanielson9747 8 ปีที่แล้ว +1

      what Garrettpov said... so many people try to act like they know,what they're talking about when they don't see a drier outside. So many brands come with it INSIDE the condenser and anyone who's actually done this work knows that. Also, you CAN put the drier inside with the air handler... its actually PREFERABLE if you work near the beach, where the salty air rusts out metal 3 times faster than normal. If you're at the beach and install a drier at the condenser, it's gonna rust out in 2 years.

  • @fakku6356
    @fakku6356 8 ปีที่แล้ว +14

    i wanna know what happened with the Asian lady

  • @bashirmohamed7982
    @bashirmohamed7982 8 ปีที่แล้ว +2

    what was wrong with the old one

  • @lethalink2730
    @lethalink2730 8 ปีที่แล้ว

    On an existing system, I have an HVAC system upstairs where the liquid/vapor (insulated & copper) lines run through the attic coming through the drywall (high on wall) from A coil extending about 35-40 feet, free hanging angling downward for about the first 13 feet before following the roof line across to the eave and finally "sorta" attached (loosely) to the attic wall structure until it exits the exterior, back wall as low to the floor line as possible. It extends the back of the house 2 stories (really one since it comes outside right above the ceiling of the first floor). So, here's my question...I'm getting ready to semi-finish the attic where it crosses - right thru the middle of the room at about head/eye level. Can I raise the lines higher than the A coil to above my 8 1/2' ceiling line (a rise of approx 1' or 2' from current level) for about 6' (lying on top on the new ceiling) then it will drop down behind the added wall and follow its existing path outside? Basically, is there any potential problem with the initial increase in rise of the line closest to the unit/A coil? Thanks for the video and any help or suggestions.

  • @philistineau
    @philistineau 7 ปีที่แล้ว

    Great work. Thanks for sharing!

  • @getgetoutout
    @getgetoutout 2 ปีที่แล้ว

    Why paint caulk instead of silicome on sealing the intake and exhaust? That wont last long.

  • @liammeli6056
    @liammeli6056 5 ปีที่แล้ว

    Airconditioning and repairs.... if you open you own business where you take care of AC installations, repairs and maintanance.... you get hella money if you manage to have a good amount of clients. You buy AC's from an AC company as an agent and then you install them for your clients or repair them, making sure you make like $100-$200 profit. Even a service of 20 minutes maximum could give you a profit of like $60.... this is business. But if you work for a company, all the money goes to them :(

  • @edwardtony3085
    @edwardtony3085 8 ปีที่แล้ว

    My house is an old house with plenty of attic space on one part of the house, but there is no access to the attic in the kitchen, and 2 more rooms, and 2 bathrooms. So now the AC guys are saying they can't run the ducts from the front all the way to the back of the house due to no space. The house is on Peers and beans, so AC guys are now suggesting to run the ducts under the house. They say the performance is the same as having it run from the attic. Only thing they say, is that when the ducts are done underneath the house, I will need to seal and secure the skirts around the house to prevent any rodents from coming in, especially raccoons. Forgot to tell you that the house is never had a central AC unit. So they will have to start from scratch. My question is has anyone been in a situation like mine and if a Central AC was installed, how did it turn out over the years? Is it a good or bad idea to run your AC ducts under ones house? I've heard they do it under houses in northern states. Any thoughts or suggestions? Thank you in advance.

    • @billybassman21
      @billybassman21 8 ปีที่แล้ว

      Very common here in the south in two story homes. No access to the ducts on the first floor, but no way to run them under the house as it is a slab. Another solution is to remove the Sheetrock to run everything and then hire someone to replace it. Ducts under the house are fine, but if they are not elevated off the ground rodents will chew through them to get in your house. Either way will work.

    • @akhileshxxx7941
      @akhileshxxx7941 7 ปีที่แล้ว

      Edward Tony

    • @jasoncurtis4404
      @jasoncurtis4404 5 ปีที่แล้ว

      Either way is fine. Just depends on access. As long as everything is sized right, and sealed up, you goid.

  • @trabajosdehvacenusa7771
    @trabajosdehvacenusa7771 4 ปีที่แล้ว +2

    Nice well done 👍.. that is exactly how HVAC jobs are done here in Tennessee......me and my partner usually do that kind of installation on an open space in about 5 to 6 hours from 8 am to 2pm. Then after 2pm we go to help the fucked up lazy crews that takes 8 to 9 hours to complete jobs.........

  • @travisturner1165
    @travisturner1165 6 ปีที่แล้ว +9

    How not to install 101

  • @samuelvalenzuela4541
    @samuelvalenzuela4541 5 ปีที่แล้ว +2

    They forgot the oil trap for the compressor and a big mistake with the outdoor unit facing the control box against the wall

    • @jasoncurtis4404
      @jasoncurtis4404 5 ปีที่แล้ว

      Oil trap for sure not needed unless the vertical distance exceeds around 25 feet. Varies per manufacturer.

    • @jasoncurtis4404
      @jasoncurtis4404 5 ปีที่แล้ว

      Also that side panel to the right, and that corner is all u need access to. The side towards the house has nothing. Everything accessible in the corner, and if a heat pump, the reversing valve is in that side panel.

  • @giomongous
    @giomongous 6 ปีที่แล้ว +1

    Where is your micron gauge?

  • @JAshw84
    @JAshw84 6 ปีที่แล้ว

    By default, the blower speed for the AC is set to high... Did you have to lower the blower speed for Air Conditioning?

  • @MKOMKONNNN
    @MKOMKONNNN 4 ปีที่แล้ว +1

    alex plus caulking on outside no no no silkaflex dudes if i were to post a video i would do a killer job on being proper and correct

  • @emilioalaniz7263
    @emilioalaniz7263 4 ปีที่แล้ว

    Is that the 90% efficiency furnaces. Never seemed one done Good stuff 👌🏽

  • @siedlaczek7118
    @siedlaczek7118 6 ปีที่แล้ว +3

    Wow the way you guys situated that condenser with a acces panel in the corner is a disaster l can se myselfe getting very upset and pissed doing a service on it. I would course you guys out for sure 😐and that grey pvc glue wtf

    • @brianrice1196
      @brianrice1196 5 ปีที่แล้ว

      That's a customer vs. technician battle that I've had to deal with too many times. panel on those units faced out vs. the model side is ugly. Customer opinion wins.

    • @jasoncurtis4404
      @jasoncurtis4404 5 ปีที่แล้ว

      The corner of that trane unit is easy to get to. And the reversing valve side is on the right. Easy to service.

  • @EDCKnifeAddiction
    @EDCKnifeAddiction 5 ปีที่แล้ว

    No one mentioned the fact that no Clean out tee, or trap was put on the drain. Hey, looks good from their house.

  • @consumersgasman8376
    @consumersgasman8376 7 ปีที่แล้ว +5

    no nitrogen trickle during brazing,would not want this install in my house

  • @danielrapkin2178
    @danielrapkin2178 ปีที่แล้ว

    They honestly could have done a way better job. First off that AC unit on that rust ass platform is going to fail. I would have cleared the brush and left it on the ground. Would have no issues down the road. 2nd is with the fresh air pipe and exhaust pipe no screen or protective barrier. Have fun getting bugs, mice, snakes and any kind of small animal that can fit in that hole. I would have called them back to redo it correctly and not rush it.

  • @gamingwithjaylenofficial2265
    @gamingwithjaylenofficial2265 2 ปีที่แล้ว

    9:28 The noise from upstairs

  • @MohamedhabakaHabaka
    @MohamedhabakaHabaka 2 ปีที่แล้ว

    محترفين

  • @pelon542
    @pelon542 3 ปีที่แล้ว

    good luck to the poor bastard that has to work on that condenser rammed against the wall

  • @JustinJustin2929
    @JustinJustin2929 5 ปีที่แล้ว +1

    Nothing like taking 24 measurements to ensure you have a 16x25 filter rack... lol

  • @FlyEaglesFly19111
    @FlyEaglesFly19111 5 ปีที่แล้ว +1

    Where is your nitrogen while brazing.. WTH..

  • @Spector_NS5_RD
    @Spector_NS5_RD 8 ปีที่แล้ว

    what's the name of the bender you're using for the ACR tubing. i'd love one of those. i'd save money rather than buying 3/4 elbows. thanks.