Trane Heat Pump with Bad HPS, Diagnosed!
ฝัง
- เผยแพร่เมื่อ 13 ต.ค. 2024
- In this video I diagnose a Trane heat pump system that has a bad High Pressure Cut-Out switch. #hvac #trane #cooling #heating #heatpumps
Check out these great tools I use on a daily basis! Use the links…SAVE SOME CASH!
WisePro 1000v Insulated Screwdriver set: amzn.to/43nBUV6
Avhrit Electric Pipe Cutter amzn.to/4e6YDKb
Discount code to save 10% : 104H1TFB
TOPTES Combustible Gas Leak Detectors.
4 TO CHOSE FROM!
PT210S
amzn.to/3QSHJEu
Discount Code: GSYQFS4Z
PT299
amzn.to/3R38JlS
Discount Code: 4A3HH88Q
PT199
amzn.to/3M5kTYs
10% off with code: N83SX3Q6
PT520B+ Professional Gas Leak Detector amzn.to/494fISD
10% off with code: R98D8JH8
TOPTES CT-300 CO Detector: amzn.to/499s23E
Discount Code: 953OHRKL
Get yourself a HIK Micro B20 Thermal Imaging Camera. Use this Link!
amzn.to/3KwRw0m
Inficon Gas-Mate Combustible Gas Leak Detector amzn.to/40ifEdL
Tesman TN-213 NCV Tester amzn.to/3rVZY3j
10% off with code: FJDYR4W3
Topdon Thermal Camera for Android amzn.to/46Wldkf
Topdon Thermal Camera for iPhone amzn.to/46Twvpu
WisePro Tradesman Backpack:
amzn.to/4912DYW
If there are any other tools and products I use in my videos that interest you…just ask! I’ll get you a link!
Support the Channel with a Super Thanks or
PayPal: @JeffsHVACAdventures
CashApp: $JeffsHVACAdventures
Venmo: @JeffsHVACAdventures
Like and Subscribe!
Questions, comments or to just say Hi, email me
jeffshvacadventures@gmail.com
I admire and respect true professionals who are skilled at what they do and perform their job with at most honesty and integrity. Thank you indeed.
Thank you for the kind words. 🤙
Man the way you troubleshoot the system is amazing, I was looking for some educational video about PS and you nailed it!
Thank you!
Happy to help friend.
Excellent call on watching the pressures before you left to make sure there wasn’t a high pressure event since you left the switch jumped out. True pro 🤙👍
Thanks man
Thank you for sharing this valuable information is showing as header with the wiring schematic
No problem brother. Thanks for commenting!
Thanks for a great video , it helps me a lot , i was having the same issue and i was able to repair it ,Thanks to you
Happy to help
Great video thanks for sharing
Thanks for watching.
Outstanding job Jeff. Which app were you using for the cap readings?
It's called HVAC School. Available in App Store or Google Play.
Great find man
Thanks
Great video man
Thanks
Dude I really like your videos because of nice approach and explains I just subscribed you. See your next video I am a preventive maintenance technician for residential only. Thanks.
I appreciate that.
This is very good video 🎉have a lot information
Thanks
That HP switch is very close to compressor discharge port and mounted straight above discharge pipe. It gets continuously cooked at high temp. Usually, they are mounted about twice the distance away from compressor discharge port and branch off to the side to run a bit cooler in temp.
Yea. I hate when they put them that close!
Is there a link to the follow up installing new switch?
No. Another tech in my company went back to replace.
I ran across that one time and I fused the run winding on the compressor temporarily so on real high pressures it would blow the fuse instead of damaging the comp...
Great idea.
Good video bro 👍
Thanks. Just Subed to your channel. Good stuff from you too!
I had this done today. I have to leave mine bypass for awhile. Due to the freon thst must be put back in. Mine takes 5lbs. And i have a heat pump.
While mentioning bad HPS I worked for the largest richest newspaper chain no good GANNETT when they were still making record profits years ago. They convinced a commercial refrigeration company to service their numerous roof top units . Rather then pay this company they agreed to place at least two or three nice sized adds in the newspaper. Somebody at the service company wss on the ball and found out that they were not p!acing enough adds then when confronted they would throw add in a Saturday thunder paper of the week that hardly anyone read. So they guy dost opted replacing safety or pressure switches. Would only jump them out. Cost cheap SOB'S $5,000 every time they had to get a over 100' crane to change compressors 40 to 50' from edge if roof.
Was supposed to say two or three adds a month!
That’s one way to get back at someone. Lol.
Can you make more video troubleshooting about Mini split system
🤙
What is that app called you did test capacitor under load ? Thanks
It’s called HVAC School
apps.apple.com/us/app/hvac-school/id1436085954
Perblam E2 model termosta SERVICE FIRST Trance Rooftop SENO 1577
Give it the old wake-up knock.. never works unfortunately..
A LOT of wind noise!
Sorry bout that.
Hmmm.......TRANE XR-17 2-STAGE 4 TON HEAT PUMP UNIT.....GOOD STUFF....surprising the High-Pressure-Cut-Out-Switch failed at only 3.5 - 4 service-life years.....must have been made overseas and "wired-up" in Tyler, Tx. with the main unit.
Yea. I found it strange too. Thanks for watching!
does that pressure switch have a Schrader valve or will you need to recover all the gas to change it?
It’s brazed in. So I’ll have to recover.
Just break it. Lol 😆
The way to fix this without ripping off the customer with all this labor is to just add a tee to the high side schrader valve outside the unit where you'd put you gauge on. Then add your new pressure switch there. Easy and less than 15 minutes worth of effort.
@@billderby1527 Yea, ive done that before. But this unit is under warranty and still has probably 15 years of service left. Rather bring it back as close to factory as possible.
@@billderby1527I would assume you would pull the valve stem core in the original valve before the tee. Right?
Why would you cut the wiring, the possibility of a defective plug needs to be established. Just jumping the plug wouldve been easier
Already ruled out the plug before I cut the wiring. Plus I still wanted the LPS to be operational. Jumping the plug would have bypassed both switches.