Installation guide -- Danfoss Thermostatic Radiator Valves: radiators with side connection

แชร์
ฝัง
  • เผยแพร่เมื่อ 10 ม.ค. 2025

ความคิดเห็น • 15

  • @NEWsklepusaNEWsklepusa
    @NEWsklepusaNEWsklepusa 2 ปีที่แล้ว

    what position needs to be valve open? closed? or between when you install thermostatic operator?

    • @DanfossClimate
      @DanfossClimate 2 ปีที่แล้ว

      Thanks for the question. Since this is the valve with a pre-setting, the setting should be set as mentioned in the video, in that case on 3. You can check the correct setting for your radiator valve using Danfoss Installer App, with Radiator Presetting tool www.danfoss.com/en/service-and-support/downloads/dhs/danfoss-installer-app/#tab-overview. Once the radiator valve is mounted, turn up radiator thermostat to 5, and then down to 3, as shown in the video.

  • @janso1
    @janso1 8 ปีที่แล้ว +1

    Please give more information on the adjustable ring. It is clear how it relates to the figure table, but how does it work? As Loftur Hjalmarsson asks below, how should it be set
    for maximum flow?

    • @DanfossHeating
      @DanfossHeating 8 ปีที่แล้ว +1

      Hi Jan
      The adjustable ring is connected to an orifice in the valve.
      With this ring it is possible to set the correct flow for the radiator.
      With this you can make a static balancing of the system by setting the presetting to the correct amount of water.
      The maximum for the valve is pos. (N). The valve goes from 1,2,3,4,5,6,7, and N
      Have a good day
      Danfoss Heating

    • @janso1
      @janso1 8 ปีที่แล้ว

      Thank you!

    • @sasant310
      @sasant310 3 ปีที่แล้ว

      @@DanfossHeating Hi, i have the same issue :) I set the valve in N position and put the thermostat back, all the way open (5) but it gets cold so I have to remove the whole thermostat and use the radiator without it. That's a bit too hot. any suggestions?

    • @DanfossHeating
      @DanfossHeating 3 ปีที่แล้ว +1

      Hi @@sasant310​, Thank you for your comment.
      It can be the setting 'N' is the imagined setting, but in reality it is not and perhaps on a low value (1-3 or so) or even worse; in between 1 and N meaning the valve is fully closed. The 'pointer' (in reality more like a small | on the valve body) for setting the valve is very small and sometimes hard to recognize, a mistake can be made here. This 'pointer' also depends the exact product type which was used.
      You mention when the thermostat is removed, it gets too hot. The practical way to solve it is to have a rubber hammer and tick on the valve body a few times to see if it 'gets loose'. If so, it would be a temporary solution and same can be expected when heating is switched off for longer period of time again in future. But for short term issues, it is solved. Hope this was helpful so far :-) Please, reach out to us for any further information if needed.

  • @andriiprychepa7023
    @andriiprychepa7023 4 ปีที่แล้ว

    Why did you choose Delta P is 10 ? Thank you .

    • @DanfossInstallerLife
      @DanfossInstallerLife  4 ปีที่แล้ว +1

      Hello Andrii
      Thank you for the question.
      We have set Delta P to 10, because in typical radiators the pressure drop about 10 kPa.
      Have a good day
      Danfoss Heating

  • @miloslukic6033
    @miloslukic6033 4 ปีที่แล้ว

    Please tell me size of this wrench on 1:18

    • @Thammuz90
      @Thammuz90 3 ปีที่แล้ว

      Depends on the size of the valve.
      If the valve is for 1/2" then it's 1/2", if it's 3/4" it's 3/4"... you can guess the rest.

  • @NikolaiPonomaryov
    @NikolaiPonomaryov หลายเดือนก่อน

    Подскажите цену

    • @DanfossInstallerLife
      @DanfossInstallerLife  หลายเดือนก่อน

      Здравствуйте, пожалуйста, обратитесь за помощью в ближайший офис Danfoss: bit.ly/3aQedtE.

  • @anthonydoriand
    @anthonydoriand 2 ปีที่แล้ว

    Thank you :)

  • @lofturhjalmarsson295
    @lofturhjalmarsson295 8 ปีที่แล้ว

    the adjustable ring around pin ting , what , how , to set it for maximum flow or what purpose has it. chosen number seems to be supposed to point towards oven raddiator heater, . guess the n means no flow, and numbers for max flow , 1 for little , 7 much .