Receptacles not working, Troubleshooting Receptacles, No Power. Disney Manager.

แชร์
ฝัง
  • เผยแพร่เมื่อ 27 ส.ค. 2024
  • Troubleshooting Receptacles John Shook, Retired Disney Maintenance Manager: Plug A light into the receptacle not working, bang on wall above each receptacle and switch in the room to see if the light flickers, if not open each receptacle and switch and check the wiring. JS

ความคิดเห็น • 238

  • @TheJediChef
    @TheJediChef 5 ปีที่แล้ว +22

    Hi John, you were my instructor at the NCE briefly. You defined the phases to me one day in the lab and that was the first time it actually made sense to me. I just want to let you know that I am still pursuing the electrical field and got into the IBEW apprenticeship. I really appreciate your knowledge and efforts at sharing your electrical wisdom.

    • @zlabfab487
      @zlabfab487 3 ปีที่แล้ว

      Hey Jason, are you still in your apprenticeship? If so how are you liking it so far?

    • @4usall181
      @4usall181 2 ปีที่แล้ว

      @@zlabfab487; AA d

  • @kenkondert8949
    @kenkondert8949 3 ปีที่แล้ว +3

    Wow. I lost 5 lbs running up and down the stairsinto my basement checking and re-checking breakers to see why my outlets didn't work. This was the only video I saw suggesting to bang on the wall around the outlets to see if that would locate the problem and it worked like a charm !!! Thanks so much

  • @jimlaird4348
    @jimlaird4348 4 ปีที่แล้ว +3

    Hi John. Thanks for the video. I had several outlets dead. I verified there was voltage on the breaker output. I checked the outlet nearest the breaker and found a corroded neutral wire. Replaced the receptacle with a good 20 amp and all is now good. By the way credit to my wife for finding your great video.

  • @ErnestAbell
    @ErnestAbell 5 ปีที่แล้ว +27

    I have hired John to do work on commercial buildings. He knows what he is doing and is very professional about everything. Thanks John

    • @trailhopper45
      @trailhopper45 3 ปีที่แล้ว

      Tom Henry would be proud...

    • @MrBritrider
      @MrBritrider 3 ปีที่แล้ว

      I have an outlet that one of the two receptacles (the lower one) displays an issue. When I plug in my hair dryer but don’t switch it on, I lose power on all other receptacles down the stream. If I plug the in the hair dryer in any outlet down the stream this behaviour does not occur.
      If I plug in the hair dryer into the questionable receptacle but nothing is plugged into any receptacle down the stream the dryer or any other appliance will work as normal.
      Does this sound like a faulty receptacle?

  • @ericderosaphotographyvideo398
    @ericderosaphotographyvideo398 4 ปีที่แล้ว +8

    John, THANK YOU!! This was really fantastic. I had 3 daisy-chained outlets that were dead, no tripped breaker. I used your "tapping" the wall above the outlet method and found the loose wires. All fixed up, and more importantly, safe! Thanks again for sharing!

  • @obsoleteprofessor2034
    @obsoleteprofessor2034 4 ปีที่แล้ว +5

    I practically paid for my entire college with a little tool bag. Thank you Mr. Push-In receptacle!

  • @user-ju3od5gy5q
    @user-ju3od5gy5q 5 ปีที่แล้ว +1

    Thanks for your no nonsense excellent information. Your electrical 50 yrs knowledge/experience with this stuff is probably "only installed" in a minimum of 200 million existing homes in the US!! Please dont kick the bucket! You guys that have over 35 years experience can offer so much help to people out here who are trying to learn from honest experienced professionals and also trying to not get ripped off by so many crooks out here that seem to be around everywhere (Auto Repair Shops, Electrical, Plumbing, HVAC, Dentist, some Medical Doctors, you name it). What happened to honesty, and integrity? Thanks again for taking the time to help.

  • @freddygill3425
    @freddygill3425 2 ปีที่แล้ว +1

    Bang on nearby outlets and switches!!! Fantastic logical, early and easy troubleshooting tip!!! So simple and easily overlooked!!! Thank you so much kind Sir!!!

  • @OpaFPV
    @OpaFPV ปีที่แล้ว

    John, I just diagnosed a GFCI issue using your thoughtful and informative video. Thank you so much for sharing the experience from your career!

  • @mikehamman7307
    @mikehamman7307 ปีที่แล้ว

    Wow. I just found this video. I had an outlet just stopped working for no apparent reason. It was powered by a light switch. I banged on the wall above the light switch and the outlet came on! Thank you so much!

  • @IamGoen
    @IamGoen 2 ปีที่แล้ว

    Your banging on the wall hack has saved me from having to call an electrician and from spending a few hundred bucks. Thanks!

  • @davidsowder319
    @davidsowder319 3 ปีที่แล้ว

    John, your knowledge and video helped me out today. I used a lamp and started tapping and in the second bedroom I found the culprit. Thanks so much.

  • @DIRTDIVER882
    @DIRTDIVER882 5 ปีที่แล้ว +1

    I think it would be AWESOME to have someone to pass down their knowledge & a whole life time of wisdom. How nice it must be for those who have parents gransparents etc

    • @alanroberts7916
      @alanroberts7916 5 ปีที่แล้ว

      My father knew so much stuff about relays, transformers, motors, , counters , air and hydrolic stuff. He worked on pinball machines for a while before WW2 then worked in linen supply machinery manufacturing in Chicago's downtown. He showed and taught me a lot of things. But much of it has become obsolete with time.

  • @askledhead
    @askledhead 5 ปีที่แล้ว +3

    Excellent video, straight to the point . No dragged out chatter , very informative . Thank you so much

  • @SpotWorksLNC
    @SpotWorksLNC ปีที่แล้ว

    I am back from banging on my outlets with a lamp and it worked instantly. I had a string of 5 outlets that would go out periodically without tripping the breaker. I was about to call an electrician. Thank you very much!

  • @Hamfam93
    @Hamfam93 3 ปีที่แล้ว +3

    Absolutely great video. Your explanations are done in simple terms and I love the practical advice. Even though I had a voltmeter I used a lamp like you suggested. It was way easier to see and I found the loose connection is another receptacle. Thanks

  • @raymondklucik
    @raymondklucik 3 ปีที่แล้ว +2

    What a great suggestion. Thank you for passing this tip on John!

  • @gazoomartian
    @gazoomartian 4 ปีที่แล้ว +2

    Dear John, thanks posting a very useful video. My daughter, who is also the owner of this house, plugged the vacuum cleaner in a power bar. When she turned the cleaner ON all the plugs in three bedrooms lost power. We found all circuit breaker in order. I opened up one dead plug to check the wiring. I had very small shock just like a pin pricking into skin. But now I am going to look at the 'stubbing' point of view today. Funny thing the GFCI breaker is still providing power to one of the plugs.
    If you wanted to kick the bucket you could have done years ago. Rest assure you are too old to die now like I am haha
    Jamil in Edmonton, AB, Canada

  • @johnpotter5327
    @johnpotter5327 2 ปีที่แล้ว

    John just saved me a lot of money. I followed his directions and discovered our outdoor lights on our RV had moisture issues and it kept tripping the GFI on the kitchen island.l after unloading the GFI inside the RV.. and remembering he said it could be attached to someplace weird, I unplugged the cord attached to the underbelly socket servicing the deck lighting --and that was it!

  • @scottromesburg7935
    @scottromesburg7935 5 ปีที่แล้ว +9

    I've always gone to wise owls for knowledge....don't kick to soon! you're very much needed. Thanx!

  • @McRaeStudios
    @McRaeStudios 4 ปีที่แล้ว +6

    Taping on the outlet worked for me. I found the scoundrel. Thank you.

  • @caltax9033
    @caltax9033 8 หลายเดือนก่อน

    John, Brilliant video! I have been chasing a bad receptical for a week and you solved my problems. Thanks very much and I am now a subscriber.

  • @mostlikelywedoitservices9743
    @mostlikelywedoitservices9743 5 ปีที่แล้ว +4

    John, I like your laid back style. Great information. I never thought of banging to find the break. That would sure speed up finding it vs pulling outlets. Thank you, my friend.

  • @burritobeserro
    @burritobeserro 10 หลายเดือนก่อน

    I fow your advice after a day changing outlets find out was in my office one outlet was no good with intermittent connection. Thank you John

  • @montag4516
    @montag4516 4 ปีที่แล้ว +5

    Another way, besides a lamp, to know you've turned off the correct breaker for the outlet you're working on is to plug a radio or stereo into it and turn it up. You'll hear when you've cut power to the correct outlet/circuit. This saves you from repeatedly walking back and forth from the outlet area to the breaker box.

    • @geraldhenrickson7472
      @geraldhenrickson7472 3 ปีที่แล้ว +2

      I think you missed the point. Finding the correct breaker is an entirely different matter. In this episode we are locating the guilty connection that plagues us.

  • @mvred100
    @mvred100 4 ปีที่แล้ว +1

    John, I really liked your video and appreciate you sharing your knowledge of the electrical trade.

  • @ianmitchell4662
    @ianmitchell4662 6 ปีที่แล้ว +10

    Fantastic advise John. Thank you for passing on your knowledge. Had issue where suddenly 2/3 of receptacles/lights on branch circuit stopped working. This video had all the information I needed to troubleshoot and find the issue. Ended up all receptacles were push in connected and one had burned up. All the issues you covered were found, including discovering that the one branch circuit has 3 bedroom lights and 9 receptacles. House was built in 1968 so maybe they could get away with that back then. For now I have replaced the bad receptacle and have reconnected all the other receptacles using the screw terminals rather than push ins.

    • @alwaysforeigner
      @alwaysforeigner 6 ปีที่แล้ว +1

      I had the same problem and it turned out that a cable was loose in a bathroom socket, Now is working properly

  • @martingelter8064
    @martingelter8064 2 ปีที่แล้ว +1

    Thank you for this video! I was able to identify two bad outlets using the "tapping" method. I replaced them and now the entire circuit is working.

  • @martyvanord984
    @martyvanord984 ปีที่แล้ว

    Thank you sir. I subscribed at the tap the wall tap tip. There is just no substitute for long term hands on expierience that has had time to grow to the point that it becomes part of the intuition of the diagnostic procedure. Sadly when I ask after life time expierience, all to often I get the reply that they were amazing but the guy that I knew retired.

  • @albey2k
    @albey2k 3 ปีที่แล้ว

    Thanks for sharing your knowledge, wisdom, and experience with the world. Four receptacles now working. Much appreciated! :)

  • @KModica11
    @KModica11 3 ปีที่แล้ว

    Thank you very much! Great advice and more important - clearly and simply explained. Saved me a lot of time and aggravation on my 4th of July weekend. Thank God for people like you sir. Happy Independence Day.

  • @ManuelSanchez-tj5nu
    @ManuelSanchez-tj5nu 5 ปีที่แล้ว +3

    Greatly appreciated your knowledge and effort and most of all your noble spirit that's willing to share with all of us out here, thank you!

  • @sangramsingh3591
    @sangramsingh3591 5 ปีที่แล้ว +2

    Old school.. simply awesome...!!! Thanks for posting this.

  • @Saurous3098
    @Saurous3098 3 ปีที่แล้ว

    Great stuff...explained like we are in the same room.

  • @mgmmason8743
    @mgmmason8743 4 ปีที่แล้ว +1

    Thank you John for your knowledge, very much appreciated. God bless.

  • @johnallison5712
    @johnallison5712 6 ปีที่แล้ว +1

    Thanks John - the video was very helpful. I was able to identify which outlet had a problem by plugging the lamp in and tapping on the outlet!

  • @davidparker2173
    @davidparker2173 ปีที่แล้ว

    Thumbs up. Thanks. I got lots to learn. I do though know how to use my "idiot light". Got lots that don't work. Thankfully there is a Square D Homeline service panel with AFCI breakers protecting me till I figure it all out.

  • @jerryross5423
    @jerryross5423 4 ปีที่แล้ว

    Thank you! I had a number of outlets go dead, was getting voltage, but nothing would work when plugged in. I banged the wall over the outlet I had originally thought might be the culprit, but wasn't sure - and it worked. And it's a back stab outlet just like you said it would be!

  • @jf5016
    @jf5016 3 ปีที่แล้ว

    Great way to check your pacemaker! An idiot light! Love it!

  • @glenmartin2437
    @glenmartin2437 2 ปีที่แล้ว

    Thank you, again. Glad this video is still available.

  • @soyyo5828
    @soyyo5828 4 ปีที่แล้ว

    As I was watching your video we both said at the same time OUT OF LUCK when wiring a custom home - LOVE YOU MAN - You are definitely a MASTER

  • @es2194
    @es2194 3 ปีที่แล้ว

    Thank you Mr Shook. Excellent video. I’ve got a game plan now to tackle my issue.

  • @gl8585
    @gl8585 5 ปีที่แล้ว

    I had an outlet that stopped working in a bathroom in the back of the house, it was a terminal outlet in the wiring, replaced the outlet, still no current, checked all the wires, all good, so went to breaker panel, all was good, on my way back into the house noticed my solar hot water LED control panel was off. It was plugged into a GIF outlet on the garage wall, GIF outlet had tripped, reset and solar control panel came on and the outlet in the back bathroom now works! So the information about daisy chained outlets was very helpful.

  • @jamesmarshall8373
    @jamesmarshall8373 2 ปีที่แล้ว

    I'm laughing at this video because I discovered this trick 2 weeks ago purely by accident! A light in my finished basement wouldn't turn on and a few of the nearby outlets were only registering 50 volts. All of them had the push-in wiring with cheap receptacles (had problem with them on other circuits so I've been replacing them and using j-hooks). Replaced all the receptacles and still no light, low voltage. Magically, the light started working again a week or two later. Because of another project I have to do, I had to remove an unfinished (previous owner) corner cabinet that was situated physically between the outlets and the light switch. When I took the top of the cabinet off, I spied another outlet in the wall within the cabinet. As I was pounding a pry bar between the cabinet and the wall just above that outlet, the light went out! Banged the wall above the outlet again, and the light went back on! After removing the cabinet I checked the outlet out and found in addition to the line and load wires (all just push-ins) wires to the light switch j-hooked to the outlet and the hot line to the outlet just sliding in and out of the push-in with no resistance. Replaced the receptacle, pigtailed the load and light switch wires and j-hooked the four to the receptacle. Long story short, I can testify that your advice works!

  • @MichaelPickleball
    @MichaelPickleball 3 ปีที่แล้ว

    Thanks for the sound advice. After swapping out 2 outlets on a circuit and no success. I decided to search for answer on TH-cam. I had my voltage tester plugged in and banged on all the plates and watched for the tester light to go on. It was the 3rd one that I had not swapped out. Took out the socket, had fired wires. Replaced it and all's good.

    • @JohnShook
      @JohnShook  3 ปีที่แล้ว

      th-cam.com/video/IS46G_WoKWA/w-d-xo.html John Shook

  • @patcupolo9274
    @patcupolo9274 6 ปีที่แล้ว +1

    A ton of information from. A professional, not afraid and sure enough of himself, to pass on his knowledge

  • @stantaur3
    @stantaur3 6 ปีที่แล้ว

    Thank you for a great explanation and demonstration of the diagnostics for when your breaker might not be tripped, but you have an outlet that's not working (likely because of push-in connnector fault).

  • @theresamoore7634
    @theresamoore7634 ปีที่แล้ว

    Thank you very much for the video !! Take care 💗

  • @jeraldgarner1636
    @jeraldgarner1636 4 ปีที่แล้ว

    Great, very understandable and concise. John's advice is great!

  • @cortaza007
    @cortaza007 5 ปีที่แล้ว +1

    Thank you for sharing your time and your knowledge. I recently move to an apartment and I have some receptacles they don’t work.

  • @johnr.6029
    @johnr.6029 3 ปีที่แล้ว

    Very good. Now I can go to work fixing my problem receptacles. Thank you.

  • @howardlovecraft750
    @howardlovecraft750 5 ปีที่แล้ว

    It doesn't take long watching a video to know if the person is a professional. Thanks for the info.

  • @deezzbeatz8983
    @deezzbeatz8983 5 ปีที่แล้ว +1

    Thanks for the knowledge and your wisdom ,it's really what I needed to know ,these other guys where giving up nothing but worthless information,, appreciate you💥💪💥

  • @ogearbox6132
    @ogearbox6132 2 ปีที่แล้ว

    John, neat name Shook Electric lol. I have a 15 yr old house with 6 receptacles in our bedroom where the top receptacles is controlled at the wall switch. Last week the top ones went dead. No tripped breaker no sparks. Today I changed two receptacles and still the same I’ll try the bang on he wall trick and see what turns up thx.

  • @hornetd
    @hornetd 4 ปีที่แล้ว +1

    This may seem a minor quibble but the National Electric Code forbids the installation of 20 ampere receptacles on 15 ampere circuits. That's because the 20 ampere receptacle will except both a 15 ampere plug and a 20 ampere plug. 20 ampere plugs are installed on equipment that will draw more than 15 amperes but not a whole lot more. Circuit breakers open much more quickly on a dead short than they do on overloads. While the thermal sensor of the circuit breaker is getting hot enough to trip the breaker damage may occur on some weak point on the circuits wiring. It may not be enough damage to prevent the receptacles and luminaires; which is the code term for lighting fixtures; to continue working but it may well be enough to cause a problem later. High quality receptacles are available in the fifteen ampere receptacle pattern. 15 ampere receptacles will not allow a 20 ampere plug to be inserted so you have less likelihood of a damaging overload.
    I agree completely that the back entry screw clamping receptacles are superior in many ways to side wired binding screw terminals. I also agree completely that any other type of terminal is superior to the back wired spring terminal terminals. Spring contact terminals have a far higher rate of failure per 100,000 installations than either of the 2 other types of terminals.
    --
    Tom Horne

  • @KevinCoop1
    @KevinCoop1 5 ปีที่แล้ว

    John, As an electrical design engineer that worked for electrical contractors for over 35 years, although I would not design circuits this way, for general purpose receptacles the NEC allows 10 receptacles on a 15 amp breaker and 13 receptacles on a 20 amp breaker. The information is as follows: receptacles are considered 1.5 amperes each for load purposes, this is also considered a non continuous load. So fully loaded would be 15 / 1.5= 10 receptacles. 20 /1.5= 13.3 so 13 receptacles. As I said, this is NEC, not what I would design.

  • @kevinvt4174
    @kevinvt4174 10 หลายเดือนก่อน

    John, You should tell people the correct way to wire the plug after you find the problem. If you have 2 romex wires in your box add a pigtail to each wire - Hot, Neutral & ground then run your pigtails to the plug so if the plug burns out, breaks or anything else it does not effect the plugs downstream.

  • @geraldhenrickson7472
    @geraldhenrickson7472 3 ปีที่แล้ว

    Thanks John. Will try the BOW technique to locate my bad outlet/switch that causing my issues.

  • @jamescc2010
    @jamescc2010 2 ปีที่แล้ว

    Always great to learn , tricks and such, from long time experience. POT LUCK. Thank you

  • @hotwheelmanraven2289
    @hotwheelmanraven2289 4 ปีที่แล้ว

    That is a very good idea. I will try that. I have one room that's got four circuits not working and it's driving me crazy panel says all the breakers are on. So I will try that today. I thank you very much. I wish you lived close I had to come over here and fix the damn thing.

  • @thundercrow1965
    @thundercrow1965 5 ปีที่แล้ว +1

    Thanks for your clear, concise help. Much appreciated!

  • @tudocervera3764
    @tudocervera3764 2 ปีที่แล้ว

    WE THANK YOU SIR FOR YOURE KNOWLEDGE..

  • @barbarocaballero9596
    @barbarocaballero9596 4 ปีที่แล้ว

    Thank You very for the feedback!!🙏🙏

  • @carsonestes2763
    @carsonestes2763 4 ปีที่แล้ว +1

    Your awesome great video to watch with some experience thank you very much sir for the time you and effort you put in to it

  • @jenko701
    @jenko701 6 ปีที่แล้ว +3

    I like to pigtail behind the outlet so the outlet it self is never Carrey’s pass through current. Great video.

    • @1575murray
      @1575murray 4 ปีที่แล้ว

      That is good practice but is more time consuming. Builders are very cost sensitive so in many places I have seen the push in terminals used as it saves a lot of money. If I replace a receptacle in that situation if I don't pigtail the new one I use the side screw terminals as they are more reliable. Also he talks about using 20 amp receptacles on a 15 amp circuit what he really means is 15 amp receptacles rated to pass through 20 amps which is available on commercial grade receptacles not inexpensive residential grade ones. It would be an electrical code violation to use a receptacle which can accept a 20 amp plug on a 15 amp circuit as using a load which exceeds 15 amps will overload the wiring and trip the circuit breaker.

  • @ottoroth9377
    @ottoroth9377 5 ปีที่แล้ว

    Great info from one old guy to another. What I do when I rewire either for remodel or new work..I put each room on its own circuit and I supply each room with a single 20 amp circuit along with the 15 amp run. Makes it easier to troubleshoot and see which breaker goes to what...the 20 amp is for a space heater and will have a single round plug. I cannot stand a wiring job connecting two or three rooms, or sharing an outside outlet. Also...all outside outlets I install are 20 amp and separate from anything else. Bathrooms too..a 20 amp. I also keep the proper outlet according to the amp circuit I run. Another point is I use Insure connectors (because I can see the connection where in a wire nut, you cannot) and run a separate pig tail to the outlet, that way the outlet is not being stressed

  • @phenix1307
    @phenix1307 4 ปีที่แล้ว

    Thank you Mr. Shook, your advise help me.

  • @emeraldcity9574
    @emeraldcity9574 4 ปีที่แล้ว

    Thank you for your insight and experience. I was able to make the repair.

  • @chenlaoding
    @chenlaoding 5 ปีที่แล้ว

    Thanks for your very educational and practical videos

  • @houseofwisdom3579
    @houseofwisdom3579 4 ปีที่แล้ว

    Thank you for passing your knowledge along.

  • @thirdeye7611
    @thirdeye7611 2 ปีที่แล้ว

    Nice of you. Thank you.

  • @aaronmaturino5572
    @aaronmaturino5572 6 ปีที่แล้ว

    Thanks for the quick to the point lesson

  • @Wayman_Simmang
    @Wayman_Simmang 2 ปีที่แล้ว

    Thanks John! Great tips!

  • @tm71100
    @tm71100 5 ปีที่แล้ว +1

    Thank you very much John , you just fixed my problem.

  • @RiverPlaid
    @RiverPlaid 5 ปีที่แล้ว +6

    Thank you for sharing the valuable insight you have.🌸

  • @skipd9164
    @skipd9164 4 ปีที่แล้ว

    Wow loved your advice and I'm hoping it will help me. I have a good knowledge of electrical systems but not an electrician. I'm an appliance repair tech that helps friends save money. I'm going to put this to use and hope to reply with a thank you.

  • @anilbharat
    @anilbharat 5 ปีที่แล้ว +1

    Thank you! I fixed receptacles problem in my home office...

  • @MommaheartsMakeup
    @MommaheartsMakeup 4 ปีที่แล้ว +2

    You've been a great help. Thank you so much!!!!!!!!!!!!!!!!!

  • @bobhaire3039
    @bobhaire3039 5 ปีที่แล้ว

    Hey John, Thanks for the excellent video. You make it simple and understandable. Even for an old technician. I am 74 and never knew about a whiggy and about the weaknesses of the connections inside the outlets. Power is totally different than instrumentation that works off of milliamperes ! Glad you are taking time to educate some us so we don’t get frustrated and give up. Sometimes experience is the only answer. Do you have a video on voltmeters and ampmeters ? I will search and see. Thanks again. Bob//

    • @JohnShook
      @JohnShook  5 ปีที่แล้ว

      th-cam.com/video/goPZ1UhrBWw/w-d-xo.html

  • @dexstjok1
    @dexstjok1 3 ปีที่แล้ว

    Thank you Sir. Great video.

  • @usntheboy1
    @usntheboy1 5 ปีที่แล้ว

    Excellent video! Saved me a couple hundred dollars! Thanks you so much!

  • @tonyb4887
    @tonyb4887 4 ปีที่แล้ว

    Thank you boss, this vedio is very helpful it's as clear as day light .

  • @glenmartin2437
    @glenmartin2437 5 ปีที่แล้ว +1

    Thank you. This is a time saver.

  • @frankmeyst1923
    @frankmeyst1923 5 ปีที่แล้ว

    Thanks from a 40 year tile guy who hates dealing with electrical.

  • @johndicus123
    @johndicus123 ปีที่แล้ว

    I wish I'd seen this before buying a new circuit breaker for an entire circuit that went dead. Turns out the first receptacle hot line had come out over the thirty years since it'd been backstabbed. I got a better receptacle and back-wired it in. Soon I'll get some more Romex and properly pigtail the leads with a single line out to the receptacle.

  • @TheShop.
    @TheShop. 5 ปีที่แล้ว

    Great information on testing an outage. Thanks

  • @skydaver2
    @skydaver2 4 ปีที่แล้ว +1

    do the lights in the room run off the same connections? because I have 5 outlets that have no power. I used my phone recharging in every socket in the room and outside the room and the issue is only with the electrical sockets the lights work. I will look to see if you talk about a switch box in one of the other videos.

  • @entoletao
    @entoletao ปีที่แล้ว

    Fantastic Info

  • @johnt890
    @johnt890 3 ปีที่แล้ว

    Great instruction

  • @victorm.4167
    @victorm.4167 4 วันที่ผ่านมา

    Don't use a lamp, use a LOUD RADIO. You can hear it on separate floors.

  • @carlosmartinezreborned6403
    @carlosmartinezreborned6403 5 ปีที่แล้ว

    Awesome video, great knowledge, and I appreciate you passing all of this information on before you kick the bucket my friend.

  • @SparkY0
    @SparkY0 4 ปีที่แล้ว +2

    Please don't put 20Amp receptacles on 15A breakers. Like ever. For safety... And By law.
    You see that extra bit of hole on the front of the 20A outlet? That's keying to stop you from overloading a 15 A circuit with a 20A device. Installing outlets that lets people overload a circuit is a bad thing.
    This isn't a "bigger is better" situation. This is a "too much will not pass inspection and could burn down your house" situation.

    • @JohnShook
      @JohnShook  4 ปีที่แล้ว

      Then they should make 15 amp receptacle a lot better then they are now. I have seen 25 or so 15 amp receptacle just melt down and not trip the 15 amp breaker. (In My 50 years or so)

  • @geocapistrano4364
    @geocapistrano4364 ปีที่แล้ว

    Thank you 🙏🏽

  • @O.Bey7Podcast
    @O.Bey7Podcast ปีที่แล้ว

    Hello Jason...I recently installed a 100amp electric main panel from a small one. This one holds 30 breakers. I was able to put my Dr. infrared electric heater which is a double 40/40 post and my electric water heater a double 30/30 post and a wall electric heater double 20/20 post....working really good. When I tried to add a receptacle for a lamp...the light flickers and I cannot seem to find the problem.

  • @kattiablanco4611
    @kattiablanco4611 4 ปีที่แล้ว

    Thank you! Very helpful!

  • @timothygorman6972
    @timothygorman6972 ปีที่แล้ว

    Thank you Sir

  • @roberthiday3342
    @roberthiday3342 5 ปีที่แล้ว +2

    just started watching your videos and love 'em. thanks. I am confused about where to buy a 'wiggie. I understand what it does, but cannot find anything on Amazon, or the big box store that seems to be the device you are talking about. what is it called exactly? thanks

    • @JohnShook
      @JohnShook  5 ปีที่แล้ว +1

      Knopp K-60 Cat Number. 14460 Voltage Tester by Knopp, at Amazon, Or any tester that's 3000 to 4000 ohms per volt.
      Also try electrical dealers like CED, Platt, or any electrical wholesale. should have it for under $ 50.00. JS

  • @vintagespeedandperformance6615
    @vintagespeedandperformance6615 5 ปีที่แล้ว

    NEC does not have a limit on number of receptacle in a residential application. Use of pigtails prevents the overloading failures mentioned at 4:08. Never ideal to use the device as a junction. The NEC requires pigtailed neutrals on multi-wire circuits.

  • @josemorgan4524
    @josemorgan4524 5 ปีที่แล้ว

    Great Video..This Info Helped me fix my Problem ..keep up the good work👌

  • @gregorymorris8343
    @gregorymorris8343 5 ปีที่แล้ว

    Awesome video, don't kick the bucket anytime soon thanks for your expertise.