How Defrost Works on a Heat Pump! Explained Step by Step!

แชร์
ฝัง
  • เผยแพร่เมื่อ 27 ก.ค. 2024
  • In this HVAC Training Video, I show the Defrost Sequence of Operation on a Heat Pump and I Explain How Each Component Works and is Powered. The Outdoor Fan shuts off, the Reversing Valve changes the direction of the refrigerant, and the W Terminal sends power to the indoor air handler to power the Electric Strip Heaters! Supervision is needed by a licensed HVACR Tech while performing tasks as Experience and Apprenticeship garners Wisdom and Safety.
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Our Related Videos/Articles
    • How an Air Handler & H...
    • Air Handler Control Bo...
    • Heat Pump Thermostat W...
    • Air Handler with Elect...
    • Heat Pump Fan not Runn...
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Our HVACR Educational Books, E-Books, Workbooks, Cards, Posters, and PowerPoints:
    All Our Educational Products on Our Site: www.acservicetech.com/store
    All Our Educational Products on Amazon: amzn.to/48pDd82
    Mini Split Book and E-Book on Our Site- www.acservicetech.com/mini-sp...
    Mini Split Paperback on Amazon- amzn.to/3ytHJSs
    Mini Split Paperback on TruTech Tools- www.trutechtools.com/BooksGui...
    Refrigerant Charging Book and E-Book: www.acservicetech.com/ac-book
    Refrigerant Charging Paperback on Amazon: amzn.to/46xTeHf
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Our HVACR Online Resources!
    Our HVAC Calculators: www.acservicetech.com/hvac-ca...
    Our Newest Articles: www.acservicetech.com/articles
    Try our HVAC/R Quizzes! www.acservicetech.com/quizzes
    Our Other Resources: www.acservicetech.com/resources
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Tools Used in Our Videos!
    Tool Links on Our Site: www.acservicetech.com/tools
    Our Tool List on Amazon: www.amazon.com/shop/acservice...
    Support the Channel by purchasing tools through TruTech Tools!
    Use this link www.trutechtools.com/?aff=8
    Save 8% at checkout using code "acservicetech"
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Follow Us On Our Social Media & Podcasting Channels!
    Patreon: / acservicetech
    Facebook: / acservicetech
    Instagram: / acservicetech
    X: / acservicetech
    LinkedIn: / ac-service-tech-llc
    Tiktok: / acservicetech
    Spotify: open.spotify.com/show/74KXLz5...
    Apple Podcasts: podcasts.apple.com/us/podcast...
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    ⚠️ Disclaimer:
    Information in this video is intended for educational purposes only. Any work related to the topics in this video should be performed by licensed technicians or by apprentices under the supervision of licensed technicians. AC Service Tech LLC is not responsible for any possible damages or injuries caused by the use or misuse of any information provided. ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    #hvacr #hvacr #hvactrainingvideos #hvactraining #hvactraining101 #acservice #acservicetech #defrost #component #reversingvalve #valve #airhandler #eletrical #stripheating #heating #heaters
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Shop through Amazon! Your Purchases through Amazon provide a means for channels such as mine to earn advertising fees from all purchases after clicking through. Prices are the same as normal.

ความคิดเห็น • 137

  • @acservicetechchannel
    @acservicetechchannel  3 ปีที่แล้ว +3

    -Thermostat Wiring Quizzes www.acservicetech.com/quizzes
    -Our Website has FREE Videos, Calculators, Podcasts, Articles, Tips, Quizzes, Q/A: www.acservicetech.com
    -Facebook Tips: facebook.com/acservicetech
    -Tools we use, Our Book, Workbook, and Quick Cards: www.amazon.com/shop/acservicetech
    -Join our updates list for an email strictly from us for new videos, articles, products and website features! www.acservicetech.com-Our E-book, Paperback, Workbook, Quick Cards, PowerPoints, www.acservicetech.com/store
    -Posters, Book, Workbook, Cards on Amazon: www.amazon.com/shop/acservicetech
    -Our E-book: play.google.com/store and iTunes and search "ac service tech"
    -Posters & PowerPoints on our Website: www.acservicetech.com/store
    -Spanish Paperback and E-book: www.acservicetech.com/libros-en-espanol

    • @saulsanchez9531
      @saulsanchez9531 2 ปีที่แล้ว

      id like you to make a troubleshooting book how to diagnose control boards ,pressure switches ,reveasing valves and all components that the heat pumps , air handle and the funace especially in spanish

    • @jeffreybricks2687
      @jeffreybricks2687 ปีที่แล้ว

      Hey ac Service Tech, if the unit shuts off during the run timer let's say is 40 minutes and it shuts off after 20 and than runs agian will it pick up where it was when the heat turned off?

  • @Sam-dc7qp
    @Sam-dc7qp 3 ปีที่แล้ว +26

    Best Teacher hand's down

    • @jollyscaria1922
      @jollyscaria1922 2 ปีที่แล้ว

      Systeom not pnp dow no pressar relaszbai

    • @jollyscaria1922
      @jollyscaria1922 2 ปีที่แล้ว

      Ok gas revomed need mut pump down peger only down ok big pint

    • @NROhvac
      @NROhvac 5 หลายเดือนก่อน

      Yes, he is hands down the best

  • @thaitichi
    @thaitichi 3 ปีที่แล้ว +4

    I've asked this question several times online and nobody ever seems to know the answer. You are amazing!

  • @falconewk
    @falconewk 3 ปีที่แล้ว +16

    Excellent video, simple enough for this electrician trying to develop his HVAC knowledge. Thanks Craig! Your book has been helpful as well.

  • @mixtecooaxaqueno6730
    @mixtecooaxaqueno6730 3 ปีที่แล้ว +7

    One of the best hvac teacher in youtube, I'm learning a lo from your videos and book.

  • @Joe_Joe_The_HvacMan
    @Joe_Joe_The_HvacMan 3 ปีที่แล้ว +6

    I have been an instructor and in the field for 30yrs. This is an EXCELLENT presentation on time/temp defrost system! GOOD JOB!!

    • @acservicetechchannel
      @acservicetechchannel  3 ปีที่แล้ว

      Thank you very much and thanks for teaching techs. It takes passion to teach for 30 years, awesome!!!

  • @shooter2843
    @shooter2843 3 ปีที่แล้ว +11

    Another great video. I wasn't ready for the trade after trade school, your videos helped more than I can say.

  • @bigwhitemeathead7684
    @bigwhitemeathead7684 ปีที่แล้ว +1

    Your series of videos helped me locate and fix a high voltage short in the condenser and a low voltage short in the thermostat wire. This was after the professional hvac techs gave up. Thank you for creating the excellent heat pump videos and for your excellent explanations in each and every one of them!

  • @jkbrown5496
    @jkbrown5496 3 ปีที่แล้ว +4

    I have adaptive defrost on my system. It failed last year, with a board and thermistors replacement. But I looked into how it is different than the traditional time/thermostat defrost.
    It has a coil temp sensor (thermistor) instead of a thermostat and an ambient temp sensor (thermistor). It has some algorithm that determines when to defrost based on the comparison. I did learn if the ambient temp sensor fails, the board defaults to a 30 minute time cycle (and uses the same when it is first powered up till it gets a "sense" of the temperature profile). If the coil sensor fails then defrost stops like with a thermostat. Also, the selector pins on the board don't adjust the time, but rather the coil defrost termination temperature. Haven't been able to find much on the why or wherefore of raising or lowering the termination temperature.
    Testing spare coil and ambient thermistors, I noticed the resistance test current on the meter will cause them to climb reading as it warms them up. So you have to be quick about taking the reading if you want to convert it to a real world temp. Haven't found any good information of field testing for sensor drift. So it is kind of open, shorted, or seems close enough to my outside air temp reading for testing.

  • @adamcraig1568
    @adamcraig1568 3 ปีที่แล้ว +3

    Great video. Waiting for the communicating systems to be on here

  • @jeffreybricks2687
    @jeffreybricks2687 ปีที่แล้ว +1

    You also seem like a very positive and great person, thankyou Craig!

  • @vnesmuonnam
    @vnesmuonnam 3 ปีที่แล้ว +3

    Save me a lot time and money on books. Thank you

  • @drprofessor1414
    @drprofessor1414 ปีที่แล้ว

    You’re a wonderful teacher, so eloquent with your words. Very intelligent friend, thank you for your efforts and knowledge!

  • @brianosegueda3622
    @brianosegueda3622 ปีที่แล้ว

    Excellent explanation of what happens in heat pump mode.

  • @jeffreybricks2687
    @jeffreybricks2687 ปีที่แล้ว +1

    You make everything so simple man THANKYOU!

  • @tserevenad
    @tserevenad 2 ปีที่แล้ว

    DIYer here, .... wow mind bending. big respect to you pros!

  • @CHOMAHOMA
    @CHOMAHOMA 3 ปีที่แล้ว +1

    Thank you very much for your videos. They always help me to understand HVAC and to improve my skills every time.

  • @primusheating1
    @primusheating1 3 ปีที่แล้ว +3

    Always clear and precise from you my friend.

  • @aaronwynkoop7066
    @aaronwynkoop7066 3 ปีที่แล้ว +2

    Awesome job. If you could do a video on furnace and the components and maybe show the wiring that would be awesome

  • @pingpong9656
    @pingpong9656 2 ปีที่แล้ว

    Master class teacher - really clarifies the defrost

  • @albotiger7268
    @albotiger7268 3 ปีที่แล้ว +4

    Very good explanation. Great videos as usual!

  • @acrepairnearme
    @acrepairnearme 3 ปีที่แล้ว +1

    Brilliant! Best teacher on TH-cam!

  • @D2O2
    @D2O2 3 ปีที่แล้ว +1

    Turning the aux heat source on also adds energy to the refrigerant raising compressor discharge temp making for a quicker defrost.

  • @HillBillyGaragew
    @HillBillyGaragew ปีที่แล้ว

    Good job on explaining easy to understand you!

  • @hkhsm359
    @hkhsm359 3 ปีที่แล้ว +2

    Nice video. Great knowledge.
    Thanks for sharing

  • @jesusdelgado2232
    @jesusdelgado2232 2 ปีที่แล้ว

    Awesome Vid, I needed this refresher!

  • @8joh58
    @8joh58 ปีที่แล้ว

    Great explanation Craig 👍

  • @walterrisco4236
    @walterrisco4236 3 ปีที่แล้ว +1

    Really good explanation very clear am glad that your share all your knowledge of hvac thanks. :)

  • @gotchaplumber
    @gotchaplumber 4 หลายเดือนก่อน

    Great explanation!

  • @Demy26
    @Demy26 3 ปีที่แล้ว +2

    Great explanation

  • @buddycheck84
    @buddycheck84 3 ปีที่แล้ว +6

    How you have the time to make these great videos and not be in demand to teach in person across the country (all things equal of course) is beyond us,,!!!

  • @JeanMedard-fh6fj
    @JeanMedard-fh6fj 7 หลายเดือนก่อน

    Really good video!

  • @eman3208
    @eman3208 3 ปีที่แล้ว +2

    another awesome video.. Thanks!

  • @user-kh7zt4ti5x
    @user-kh7zt4ti5x 3 ปีที่แล้ว +1

    Very helpful, thank you

  • @hanound79
    @hanound79 3 ปีที่แล้ว +1

    Useful information 👍

  • @eternallife721
    @eternallife721 7 หลายเดือนก่อน

    Very nice video. Thank you very much.

  • @omarr.r1448
    @omarr.r1448 2 ปีที่แล้ว

    Awesome video

  • @juancarlossalcitas1690
    @juancarlossalcitas1690 3 ปีที่แล้ว

    We love your videos

  • @campbull_7815
    @campbull_7815 3 ปีที่แล้ว +2

    Great video

  • @tecniman356
    @tecniman356 2 ปีที่แล้ว

    You are the best!

  • @montes5686
    @montes5686 3 ปีที่แล้ว +2

    Good video thx

  • @humbertomacias3239
    @humbertomacias3239 10 วันที่ผ่านมา

    Amazing

  • @Ted_E_Bear
    @Ted_E_Bear 3 ปีที่แล้ว +1

    Great information !

  • @jjjames5089
    @jjjames5089 ปีที่แล้ว

    Great detail in your teaching, keep it up.
    Perhaps you could help, I need a parts catalog for an old Goodman model CPK224-1B heat pump.
    I'm having trouble finding the right reversing valve coil.

  • @charlesmorgan2234
    @charlesmorgan2234 หลายเดือนก่อน

    All your vids are great including this one! My only question is when the heat pump turns on electric heating in the air handler does it also turn on the air handler blower?

  • @sharky5570
    @sharky5570 3 ปีที่แล้ว +2

    Question what is the lowest outdoor temps that these things run in? I have had the things running in temps to mid teens. Ohio.. Also in a pinch I have had the dfs go bad and jumped it out till new one arrived. It would be in defrost for 10 min and go back into hp operation. Carrier did not know if it would work but it does because of the timer. Great video.. subscribed.

  • @thehifiwifiguy
    @thehifiwifiguy 2 ปีที่แล้ว +3

    Why don't they build heating elements into the coils to prevent this? It would potentially use less electricity than the coils in the handler IMO. It would also prevent the excessive reversing valve use.

  • @nickledimez4012
    @nickledimez4012 3 ปีที่แล้ว +1

    Buy his book! Great investment

    • @MaMa-qh4dy
      @MaMa-qh4dy 2 ปีที่แล้ว

      YES. You will not be sorry!

  • @johndoe-wt4ui
    @johndoe-wt4ui 3 ปีที่แล้ว

    🙌 the best the 🐐the legend

  • @NOVAServicesLLC
    @NOVAServicesLLC ปีที่แล้ว

    Any clearer and I’ll see my reflection 😂all jokes aside awesome video and very informative.

  • @x-man4702
    @x-man4702 2 ปีที่แล้ว

    Subscribed! Thanks for the video, very informative! Quick question: While the system is in defrost mode, does the fan inside the house runs simultaneously? If so, why?

    • @MaMa-qh4dy
      @MaMa-qh4dy 2 ปีที่แล้ว +1

      Yes it does. In doing so, the fan helps to transfer heat from inside the structure to the outdoor coils to defrost the ice. Additionally, the indoor fan blows air over the resistance strip heaters to heat the "cool" air due the the unit running in a/c mode during defrost cycle.

  • @spelunkerd
    @spelunkerd ปีที่แล้ว

    When in air conditioning mode, is there a similar defrost cycle to prevent freezing of the indoor coil? Why not? Is it because ambient temp in the home rarely gets so close to the freezing point? If you do see freezing of the indoor coil while in AC mode, do you think of other causes like a dirty filter, low freon charge, or other causes of poor air flow?

  • @mjfollrd
    @mjfollrd ปีที่แล้ว

    Can the heat pump only go into defrost on a heat call or does the DTS put it into defrost automatically no matter what if heat pump is running of not Great Video Thanks

  • @thisisyourcaptainspeaking2259
    @thisisyourcaptainspeaking2259 2 ปีที่แล้ว +1

    Found my defrost sensor dangling, disconnected from the coil tubing, where should it be mounted, before/after the "evaporator"?

  • @HVACRTECH-83
    @HVACRTECH-83 3 ปีที่แล้ว +3

    Or it will power up the gas burners on a gas/dual fuel setup during defrost

    • @jkbrown5496
      @jkbrown5496 3 ปีที่แล้ว

      The defrost board puts power on the W wire (independent of the thermostat) so what ever heat source W controls will come on.

  • @OcRefrig
    @OcRefrig 3 ปีที่แล้ว +2

    Good video ! Like #104.

  • @enduringpromise
    @enduringpromise 3 ปีที่แล้ว

    Hello Craig, I know this question is not related to the video. I could not find the answer on you other videos. Two questions...
    1. Is there a way to bleed the small air bubble in the BODY of the manifold gauges or is it so minimal that no one worries about that air bubble?
    2. If you do not connect the yellow hose to the tank, how do you return the high side refrigerate to the HVAC using a 3 value manifold gauge set? I believe the yellow line would be full of air and there is no valve available to isolate it from the body. Thank you for everything you do. I love listening and watching to all of your videos.

    • @sprockkets
      @sprockkets 3 ปีที่แล้ว

      Better solution, don't use archaic manifolds for checking pressures. Use probes. And if you are against electronics, use the analog equivalent, and you won't have to worry about it.
      And if you are worried about the high side and losing liquid, use this:
      www.trutechtools.com/Accutools-Shrader-Depressor-Tool-5-16Fx1-4M

  • @toolemanful
    @toolemanful 3 ปีที่แล้ว

    Off the subject what is a reset relay?? And how is it drawn? Thank u

  • @mikesweet9623
    @mikesweet9623 2 ปีที่แล้ว

    Hi, thanks for a very helpful video that you've shared with us. My question is that when it is difrosting and the gun of thr heat pump stoped working, is it normal that the compressor making a huming noise. should i let it run?; if so for how long it must run to defrost the heat pump. thank you.

    • @MaMa-qh4dy
      @MaMa-qh4dy 2 ปีที่แล้ว +1

      The hum you hear from the compressor is usually masked by the loud noise of the fan. It is normal noise. Depending on what model unit you have, some defrost according to "time," and some defrost according to demand (outdoor coil and outdoor ambient temperatures). Just let it do its thing.

  • @jeff-w
    @jeff-w 7 หลายเดือนก่อน

    Its amazing how refined the operation of these machines is, while at the same time its comical how archaic and sloppy the controls are.

  • @tylerlyons8109
    @tylerlyons8109 3 ปีที่แล้ว +1

    One thing I would correct here, the timer does not start counting run time until the defrost sensor closes, it does not "check" the sensor every 30/60/90 minutes, this is a common misconception that I also thought was the case for years, until I had a debate with another tech about this, we made a bet and bench tested a few different boards, I lost, might make for an interesting video

    • @helobeast
      @helobeast 3 ปีที่แล้ว

      And what you find im curious. Cause im thinking about putting mine on 30minutes or should i leave it at 60 minutes??

    • @jkbrown5496
      @jkbrown5496 3 ปีที่แล้ว +1

      I traced out a simple Goodman board and was surprised to see that, as you say, the board isn't even powered till the DFT closes. R to the board immediately goes out on the 2nd R terminal (with no other connections on the board) and the DFT terminal is the start of all the circuitry. So the DFT has to be closed to power the board. However, my current system with adaptive demand defrost is has always-on power via R. It even separately monitors the HPS and LPS instead of series wiring.

    • @tomozinga2267
      @tomozinga2267 3 ปีที่แล้ว +1

      Tyler is correct. This is a common misconception, it’s presented incorrectly in many training videos and books. But that defrost timer does not run unless the defrost thermostat is closed.

  • @mark_Hershey
    @mark_Hershey ปีที่แล้ว

    During defrost mode is the evaporator getting cold or does refrigerant not reach indoor coil?

  • @magnito9811
    @magnito9811 11 หลายเดือนก่อน

    what happens to the inside coil during defrost ? system basically runny on ac mode wouldn’t the inside could be cold and counter act the electric heat?

  • @manna5610
    @manna5610 8 หลายเดือนก่อน

    Is there a timer on how long the heat pump will run in heat mode before the elements will turn on? My hp will run to about 88 deg, then temp will start to drop (about 5 min), and the elements will turn on until the set temp is reached. this happens every time I start the hp in heating, even if I continually, adjust the set temp to turn off the hp and them turn it right back on. Service tech told me it is running fine, but could not explain why the elements keep turning on every time. Thanks for any help.

  • @charliemendez1479
    @charliemendez1479 5 หลายเดือนก่อน

    0:25 when this happens coil in air handle is cooling while aux heating at the same time?

  • @craigalan7911
    @craigalan7911 2 ปีที่แล้ว +1

    Hi. I’m a very tech savvy homeowner. My heat pump was diagnosed with a bad defrost board. I would like to do a self install. Other than swapping out the board, does it require any kind of recalibration or anything?

    • @MaMa-qh4dy
      @MaMa-qh4dy 2 ปีที่แล้ว +3

      No. Just be sure to disconnect power to both the outdoor unit as well as the indoor unit. You don't want to get killed, and you don't want to short-out your low voltage transformer and/or fuse.

  • @elizabethmasih4602
    @elizabethmasih4602 ปีที่แล้ว

    My AC contensate pump do not start automatic when the reservoir tank is full but the contender outside get shut off and air handler keep running

  • @jasonwee4305
    @jasonwee4305 3 ปีที่แล้ว +2

    Hi Craig
    Thank you for the awesome video and explanation
    Question : I've come across numerous H/Ps that have had the board and DFT replaced. My question is where do you think the best location for the DFT is, because sometimes I've seen them located right after the outdoor txv, or right (seems to be) the exit for the condensing coil.
    Thanks in advance

    • @acservicetechchannel
      @acservicetechchannel  3 ปีที่แล้ว +3

      I would like to see them need the middle of the outdoor coil but between the outdoor coil and the metering device works as well.

  • @chrissauter7501
    @chrissauter7501 3 ปีที่แล้ว +1

    How are we supposed to know when to use O or B?

    • @sprockkets
      @sprockkets 3 ปีที่แล้ว +2

      Rhreem and it's brands use B. Almost everyone else does O.

  • @BornToFly4031
    @BornToFly4031 5 หลายเดือนก่อน

    How does a dual fuel (Propane) defrost work (Trane 18xi) if cutout/balance temp is set to 26 degrees? And temp never gets above 26 for a few days?

  • @solexxx8588
    @solexxx8588 8 หลายเดือนก่อน

    I would think that a hot gas bypass is more efficient for defrosting and consumes less power than turning on a resistance coil.

  • @Ray-wr2wr
    @Ray-wr2wr หลายเดือนก่อน

    where is 24v coming from to the reversing valve ?

  • @charliedc2A
    @charliedc2A 2 ปีที่แล้ว

    My defrost is set to 30 minutes will this be ok

  • @mindcreation3591
    @mindcreation3591 3 ปีที่แล้ว

    Sir there is a Hitachi inverter AC. R-410a has gas. Ampere 4.1. But sir cooling is not happening. What's the problem with that, sir?

  • @joebar2249
    @joebar2249 หลายเดือนก่อน

    Hallo
    My mitsubishi heat pump stops after a half our and unit outside is frozen..
    Wher should I look for the problem..Gas is checked and refilled by technician, but no sulution.

  • @johnconnor7501
    @johnconnor7501 ปีที่แล้ว

    I don’t understand. So the 60 minute timer is just to have the board check one switch every 60 minutes? If it is why not keep it at 30 minutes instead so it check as often as possible since the temperature switch is the one actually making the decision to turn on defrost?

  • @kitchenratt
    @kitchenratt 3 ปีที่แล้ว

    👍👍👍

  • @dymarke
    @dymarke 2 ปีที่แล้ว

    Can I ask a question about a 4 zone mini split heat hump?
    I have oddities in my defrost cycle. I have a 4 zone C&H Sophia with ceiling cassettes. Usually all cassettes will defrost together but I have one cassette that will go into a defrost cycle when the other cassettes are still heating. Occasionally that cassette will stay in defrost and not complete the cycle. I have also had two cassettes (only two running at the time) that did not complete the defrost cycle and just didn't start up again. Power cycling returns proper function. This is a new system and my first mini split so I am still learning but this seems like odd behavior. Any thoughts would be appreciated.
    Thank you

    • @acservicetechchannel
      @acservicetechchannel  2 ปีที่แล้ว

      I would contact their tech support to explain what is happening and determine the cause, thanks!

    • @dymarke
      @dymarke 2 ปีที่แล้ว

      @@acservicetechchannel
      I did email them with no response but I will try again.
      Thank you

  • @johndeez2012
    @johndeez2012 2 ปีที่แล้ว

    mine pumps cold air when in defrost mode

    • @MaMa-qh4dy
      @MaMa-qh4dy 2 ปีที่แล้ว +2

      It should do that. But your strip-heaters in the indoor air-handler should turn on to warm the cold air that is blowing over the indoor coil.

    • @johndeez2012
      @johndeez2012 2 ปีที่แล้ว

      @@MaMa-qh4dy so my strip heaters might be bad

  • @throttlebottle5906
    @throttlebottle5906 3 ปีที่แล้ว +1

    heat pumps work great, without power, just ask Texas! (ok that was an uncalled for low blow lol) I almost feel bad about their overall not expecting the worst and having some form of backup plans in place or at minimum some work-around means. :| sad place of life survival skills and surroundings means to accomplish such the USA has become

  • @erichorton1440
    @erichorton1440 ปีที่แล้ว

    Pause at 6:47 and tell me his thumb isn't fake.

  • @jakemilkovich1722
    @jakemilkovich1722 3 ปีที่แล้ว

    In your given example, if the defrost cycle is a maximum of 10 minutes, why the expense and added
    complexity for emergency heat? 10 minutes of no heat, for an average building, should not even be
    noticed.

    • @acservicetechchannel
      @acservicetechchannel  3 ปีที่แล้ว +1

      The problem is that its not that the indoor blower shuts off. It is literally running in air conditioning mode and the refrigerant is absorbing heat from the building in order to move it outside to melt the ice. You can stop the indoor blower because then there will be no heat in the refrigerant to melt the ice outside, thanks!

    • @sprockkets
      @sprockkets 3 ปีที่แล้ว

      Indoor creature comfort.

    • @enduringpromise
      @enduringpromise 3 ปีที่แล้ว

      @@acservicetechchannel FYI, missed the word, "not". Cannot stop the blower...

    • @jkbrown5496
      @jkbrown5496 3 ปีที่แล้ว

      You'd be surprised how pissed off you get when your heat is blowing cold(ish) air. Even though objectively it only reduced the temp 1 degree. I started watching these videos because my system had issues. I finally learned the right questions to ask. My defrost board has two rows of terminals, input and output. When installed they'd put the W wire on the input terminal. I don't cuss the AC guy who installed the system all winter anymore.

  • @sgtfixer
    @sgtfixer ปีที่แล้ว

    Does a heat pump make a loud woosh sound during this process? I’m concerned something is wrong with my girlfriends condenser.

    • @MaMa-qh4dy
      @MaMa-qh4dy ปีที่แล้ว +1

      That is normal when reversing valve goes back to heating mode causing the refrigerant flow to be reversed.

    • @sgtfixer
      @sgtfixer ปีที่แล้ว

      @@MaMa-qh4dy thanks!

  • @realestateservicessaleshea99
    @realestateservicessaleshea99 3 ปีที่แล้ว +1

    👍🏌
    Stay safe.
    Retired keyboard super tech.
    Wear your safety glasses.

  • @kevinvillal6169
    @kevinvillal6169 3 ปีที่แล้ว

    This nigga can teach

  • @yamahasuperbike2202
    @yamahasuperbike2202 3 ปีที่แล้ว +1

    I currently have a heat pump at my residence. I'll never own another one again. Piece of shit. Not very warm in the winter and not very cold in the summer.

    • @MaMa-qh4dy
      @MaMa-qh4dy 2 ปีที่แล้ว +1

      "Not very warm in the winter" -- NORMALLY TRUE. "Not very cold in the summer" -- then, you have a problem with your unit.

  • @r410a8
    @r410a8 ปีที่แล้ว

    If a heat pump is air-water the indoor electrical resistances does continue to heat up the water? This doesn't require a nominal electric power comparable to nominal heat power of indoor exchanger element that is working like condenser in normal cylce,producing the heat power of rifrigerant compression plus refrigerant evaporation latent heat? And what happens to total electric power consume for this few minites if the machine has to consume power for compressor + electric power that equals compressor+evaporator (on normal cycle conditions)?,Doesn't this reduce dramaticaly the instant heat cop of heating from a scale multiplicate of 1 ,for instance 4,to a number lower than 1?
    If a machine gets freeze all the time and gets turn on the defroast cylce frequently for instance 1 time per hour for 10 minist ,the total cop won't be lower than a nominal eventualy?
    For instance assume a large heat pump with a nominal heat production 1Mbtu/h has a theoritical average hourly cop for a cold outdoor conditions 3,5,then to 1 hour only 1/3,5 Mbtu electrical power has been absorbed by the electrical grid and the rest 1-(1/3,5) has been absorbed as heat by the outdoor unit. If and a defrost 10 min need to be turned on ,the defrost cycle cop is 1 (because heat resistants produce all the demanding work for the defrost time,that equals 1Mbtu/h*(10min/60min) are produced now from heat resistants without having the 3/4 parts to been pumped from outdoor enviroment ) minus 1/3,5 (the theoritical work of compressor that it continues work and consume grid power without producing any good heat work indoor ,that equals 1Mbtu/h*(10min/60min)*(1/3,5) cop) = 10 minites defrost cop 1-0,285 = 0,714.So the total hourly cop isn't 3,5 but 3,5*(50min/60min)+0,714*(10min/60min)=3,035.If my calculations are right then with more time defrost cycle the more less expected average cop will you have in far cold enviromments .
    Is this a vfm thing taking to account the extraordinery coast of electrical power and the fact that the heat pump is selected for energy and money save?