Thank you sir I am Karnataka I were searching this kind of video from 2 years know I got it and I want to learn more from you sir an also I am doing more hardwork on the work electrician to achieve my goal thank you 😘✌️❤️🙏
Sir,this is a simple at the same time a brillant video,keep doing this great work..I am from electrical Bim industry..it will be very useful for my interviews.thank you so much...!!!
First time I visited your channel , great technical knowledge,keep posting new things,we will follow and keep supporting you,more over it was helping us to gain a practical knowledge as an electrical engineer I failed to learn all this thing's from my college, finally thank you keep going 🙏🙏
@@ElectricalInfinity sir can you please make a video that how we can make the SLD in software. Or please suggest me any software in which I can design these SLD
Please make a video for G+3 floor commercial + 30 floor residential. With complete load calculations and cable size selection. Hope to see the detail video soon. Apart that ur videos are really informative and neatly explained with detailed information
It's makes very easy to be understand the procedure of eliminating power load step by step thanks sir ,,,i requesting you to please make video on designing
Thank you boss , your technical teaching is awesome !!!!!! am in search of Dubai DEWA electrical designing and calculation , so kindly post a video in that topic sir .
Very much Impressive sir, I'm from Execution site but your all video made me keen interest in designing too, it clears each doubt and very very closed to the practical usage too! I think none of TH-cam channel provide perfect video like you. Keep updating and please provide your contact information like email id so that we can approach you. Thanks for making my lock down period worthful ! Thanks again sir 🙏
Very nicely made video and crisp information delivered. I have a query. What if the load changes during the project execution ? It may reduce or increase. Then what is to be done about the transformer sizing ? Such scenario occurs most of the time.
Well the project don't directly go to construction phase. There are different stages like preliminary, tender and construction set. Each stage has 3 to 4 revision. The project will start on site once the construction set is finalised. It takes 3 to 8 months to complete these stages depending on size of project. Thanks for appreciation ❤. Keep watching and keep sharing.
@@ElectricalInfinity Yes, that's true and I am aware about the project life cycle. But there are times when the client comes up with some drastic changes (atleast in India). Then how we can accommodate those changes in the already designed power system or what are the other strategies to adopt ?
We have to reassess the maximum demand to make sure the load is below total ampere. The client can't make any changes to load without consulting electrical consultant. If the load is above the limit even after diversity factors then the project timeline and cost will increase due to changes in supply capacity, reapplying supply application to supply authority, transformer sizing, cable sizing and main switchboard. The client already know the impact and it is upto him. If he want changes then have to bear the cost. We can avoid this situation by allowing 15 to 20% spare amperes for future provisions during a preliminary stage of maximum demand calculations.
Very good explanation in less time.. Please make a detailed videos for electrical Designing in parts and add it into playlist Make videos in more details like how to use safety factor of 2 Thanks in advance 😊
Sir as per codes and standards you have to multiply calculated current rating with 1.25 as a safty factor for CB calculation..then you can select available current rating.
U cant choose CB directly from calculate load current...there are many factor we have to consider as per codes while designing circuit... Means if your load current is 447A then 447*1.25=558.75 After this step you can select CB rating.
Sir can you please tell me why are we multiplying KW with Ampere for Circuit breaker sizing?can you please explain the formula or logic behind this ......
Sir, Your videos are very nice to learn even for a fresher. Please put video for selection of cable (cable sizing) in the SLD. When u will put that video sir early waiting.
Sir can you please guide me how to calculate the estimated lighting, small appliance and power loads for each space in w/sq ft. for lighting i can use ashrae standards. but for small appliances how much watt we used for per outlet or area wise?
When you find common load circuit breaker size , you multiplied the common load by safety factor. But when you do the calculation in high raise building why did you multiplied by demand factor? What is the reason for it?
very good video , but SLD is wrong since it is a high rise building your have to provide MDB , from MDB to SMDB for each floor from SMDB to DB for each Flat for eg -MDB to SMDB -1 ( floor 1) then from from SMDB 1 to DB 1( flat -1 3bhk ) , SMDB 1 to DB 2 ( 4 BHK ) etc According to the load of SMDB & DB Cable Size Has to mention in SLD
Also watch the designing of High Rise Building G plus 10
th-cam.com/video/z6_7jpO8zPE/w-d-xo.html
Thanks for your response 👍 teacher
Isn't 0.8 a poor power factor?? while calculating Transformer size??
I don't even know how to thank you. I'm very grateful for this. My God bless you.
Thanks so much 😍
I don't have word to express my feelings after watching this video... thank you so much sir....
Thanks 😊
I am here with attitude of gratitude for your sharing video. Thank you so much.
Always welcome 😊. Thanks for watching 🤗
Fabulous ,your clearing more n more doubts and making MEP field and design engineers are proud and
Are very thankful to u.
Thanks a ton
Thank you sir I am Karnataka I were searching this kind of video from 2 years know I got it and I want to learn more from you sir an also I am doing more hardwork on the work electrician to achieve my goal thank you 😘✌️❤️🙏
Thanks a lot man.. You are the real engineer
Sir,this is a simple at the same time a brillant video,keep doing this great work..I am from electrical Bim industry..it will be very useful for my interviews.thank you so much...!!!
Thanks. I will continue to do so
Thank you for this informative video. Its Really Helpful and clearing all basics doubts.
Glad it was helpful!
What a video sir The way you explained all the terms Mind blowing sir ❤️❤️❤️
Woww superb ji.. no words to say .. my doubts all are cleared.. thankyou so much ..... 🎉🎉🎉 Keep your service.. god bless you
Always welcome.
u r perfectly posting videos i have inspired technically from ur talent
Thanks so much
This video is very useful .
Thank you so much for making this video
So nice of you
Thank you this is very useful for all
Thankyou man.. i cleared my interview
Great 👍. I am very happy you cleared your interview. All the best with your job.
Very very nicely explained.... thank you sir
Welcome 😊
First time I visited your channel , great technical knowledge,keep posting new things,we will follow and keep supporting you,more over it was helping us to gain a practical knowledge as an electrical engineer I failed to learn all this thing's from my college, finally thank you keep going 🙏🙏
Thanks Gurushankar for such lovely comment. 🙂
Easily explained video... Thanks brother...
Welcome 😊
@@ElectricalInfinity by watching this video I got every basics but regard 3BHK 4BHL I am confused what is BHK?
3 bedroom 1 hall 1 kitchen.
thank you!!!!! saved my day
Always welcome
Very good valueble inpermation thank you sir🙏🙏
Most welcome
Thanks sir for providing valuble knowledge
Welcome
Thanks sir very useful information 👍
Welcome
Great videos, Really well explained. Appreciate the efforts mahn.
😊 thanks
It's clear and informative. Good job. Can you share more for commercial buildings, Industries?
Thanks✌
Best ever explaination you are amazing sir
Thanks a lot 😊
@@ElectricalInfinity sir can you please make a video that how we can make the SLD in software. Or please suggest me any software in which I can design these SLD
You can use Powercad for Sld designing. Or AutoCad for drafting sld.
@@ElectricalInfinity thank you
Thank you sir you are sharing great knowledge with us
It's my pleasure😍
Sir, god bless.. thank you a lots...
😊 welcome
Superb class .thank u so much
Always welcome
Very useful. Thanks you very much
Glad it was helpful! Thanks
Please make a video for G+3 floor commercial + 30 floor residential.
With complete load calculations and cable size selection.
Hope to see the detail video soon.
Apart that ur videos are really informative and neatly explained with detailed information
Woow sir..... Super explain 🙏... Regarding this Notes please upload or send me.. 🙏🙏
Transformer rating Calculate table
Mccb mcb table....
It's makes very easy to be understand the procedure of eliminating power load step by step thanks sir ,,,i requesting you to please make video on designing
Sure I will
Very useful video 👍
Thanks 🙂
Good Information sir
Superb bro 😎
Thanks
🏇🏇🏇🏇🏇🏇 awesome sir🤺🤺🤺🤺🤺🤺🤺
so useful... Plzz keep it up Sir G
Thanks
Plzz go ahead
This is good video, thanks
Welcome
this is great. Thanks
Glad you liked it!
Great...
Thank you boss , your technical teaching is awesome !!!!!! am in search of Dubai DEWA electrical designing and calculation , so kindly post a video in that topic sir .
Always welcome. Thanks for your kind words 😍.
Very much Impressive sir, I'm from Execution site but your all video made me keen interest in designing too, it clears each doubt and very very closed to the practical usage too!
I think none of TH-cam channel provide perfect video like you. Keep updating and please provide your contact information like email id so that we can approach you.
Thanks for making my lock down period worthful !
Thanks again sir 🙏
Thanks for appreciation. Such comments inspire me to make more videos ❤
We learning many things from your video. thank you
I request to you please upload a video -G+22
Thank you 😊
very nice explain
Thanks
Nice one....keep going...good luck
Thank you shaif
Very nicely made video and crisp information delivered.
I have a query. What if the load changes during the project execution ? It may reduce or increase. Then what is to be done about the transformer sizing ?
Such scenario occurs most of the time.
Well the project don't directly go to construction phase. There are different stages like preliminary, tender and construction set. Each stage has 3 to 4 revision. The project will start on site once the construction set is finalised. It takes 3 to 8 months to complete these stages depending on size of project.
Thanks for appreciation ❤. Keep watching and keep sharing.
@@ElectricalInfinity Yes, that's true and I am aware about the project life cycle. But there are times when the client comes up with some drastic changes (atleast in India). Then how we can accommodate those changes in the already designed power system or what are the other strategies to adopt ?
We have to reassess the maximum demand to make sure the load is below total ampere. The client can't make any changes to load without consulting electrical consultant. If the load is above the limit even after diversity factors then the project timeline and cost will increase due to changes in supply capacity, reapplying supply application to supply authority, transformer sizing, cable sizing and main switchboard. The client already know the impact and it is upto him. If he want changes then have to bear the cost.
We can avoid this situation by allowing 15 to 20% spare amperes for future provisions during a preliminary stage of maximum demand calculations.
Very good explanation in less time..
Please make a detailed videos for electrical Designing in parts and add it into playlist
Make videos in more details like how to use safety factor of 2
Thanks in advance 😊
Welcome.
And thanks for tips
very useful videos
Thank you🙂
thank you
Good. Man.
Thanks bro
Sir will you undertake load calculation and Transformer sizing and MCB sizing for private building.. we will provide all details
Great effort
Thank u nani 😁
Excellent
Thanks
excellent
Thank you! Cheers!
Tq for the explanation and interactive. Sir, could you please share the calculation to decide the cable sizing please.
Can we calculate one city power consumption in similar manner?
Hello sir, on base you selected multiplying factor for 3 phase Ampere current . Multiplying factor 1.9
Great
Thanks 😊
Could you please clarify why do we need multiple with 2 for CB sizing for load
Mashallah
sir, can i ask to you, what type smartphone you use ? very usefull aplication. big thanks, please answer sir
S9
How to did you calculate multiplying factor(1.4,1.9)
Good video
Thanks
Though I'm a fresher still I understood maximum part of these video
Great work sir...
Can I get your linkedIn id ?
❤
Thank you sir for the session. Simple and easily explaned . which device you are using to write. Can you inform with its make.
Yes, sure. I am using I pad 7th gen.
Sir as per codes and standards you have to multiply calculated current rating with 1.25 as a safty factor for CB calculation..then you can select available current rating.
U cant choose CB directly from calculate load current...there are many factor we have to consider as per codes while designing circuit...
Means if your load current is 447A then 447*1.25=558.75
After this step you can select CB rating.
I would like to learn designing and drafting. Can you guide me what kind of course should i do. What software should i learn..
Sir i hava doubt we have 15nos 3 bhk then we use 15 nos 63amp circuit braker for each 3 bhk ? Am i right ?
Good
Thanks 😊
Excellent sir, thanks a lot . Kindly do design video for high rise towers like 20 floors and above. Regarda
Welcome. Will make one soon
we will waiting for ur next video related to design
@@sefatullah441 here is a video for you on high rise building th-cam.com/video/z6_7jpO8zPE/w-d-xo.html
thanks alot sir G... you are genius
thanks alot sir g... try to upload more videos related to building design..
cable sizing farmula etc... more videos please..
God bless you
👍👍👍👍👍
Awesome constant !!! Can you give a book or published paper reference on your the statement and formula that you used in the video?
That’s what we follow at our workplace and I don’t have any published papers on this.
Sir can you please tell me why are we multiplying KW with Ampere for Circuit breaker sizing?can you please explain the formula or logic behind this ......
Mam I really impressed your knowledge..And i have plz request ,I want to Work with under your guidance... 👍👍🙏
😊Thanks
Sir,
Your videos are very nice to learn even for a fresher. Please put video for selection of cable (cable sizing) in the SLD. When u will put that video sir early waiting.
Thanks for appreciation. Will try to make one on cables. Btw I have made one video on cable sizing
Good explanation...I need this type of wrtiting pad....where I get?
Its Ipad
Thank you sir .. Can you please recommend book Or any online course so we can learn in detail 🙏
Sir what's the reason to use a 50 amp MCB for 29A load?
amazing vidio please make for hotel
Thanks
I subscribed already bro
Thanks buddy ✌
Sir can you please guide me how to calculate the estimated lighting, small appliance and power loads for each space in w/sq ft. for lighting i can use ashrae standards. but for small appliances how much watt we used for per outlet or area wise?
When you find common load circuit breaker size , you multiplied the common load by safety factor.
But when you do the calculation in high raise building why did you multiplied by demand factor?
What is the reason for it?
try to upload more videos related to electrical design plzz
very good video , but SLD is wrong since it is a high rise building your have to provide MDB , from MDB to SMDB for each floor from SMDB to DB for each Flat
for eg -MDB to SMDB -1 ( floor 1) then from from SMDB 1 to DB 1( flat -1 3bhk ) , SMDB 1 to DB 2 ( 4 BHK ) etc
According to the load of SMDB & DB Cable Size Has to mention in SLD
Good ,But miss the cable part... Sizing and type according.
How to avail these standard tables for transformers, circuit brrakers and cables??
💐💐💐💐💐💐💐💐🔥
Why is a safety factor of two used for end MCB ratings?
sir plz make a video on DG sizing
Sir, pl tell wat is the incomer cable from metering panel to house
How can we decide the short circuit ratings of MCCB and MCB?
any software would you recommend for this ?
AUTOCAD
Can you please provide the links to sizing charts you used in this video
Please prepare similar video for 30x40size 3 floor building
We TP mccb for common load?
Sir is the peak demand of the building is the total load of the building
Hi why did you use a 3P MCCB after the transformer instead of a 4P MCCB
What about ground floor sir ... is there no 3bhk and 4 bhk flats in ground floor ?
Parking mostly
Great work butt need to explanation more ni detail samliar project like larga plaza or shoping malls or multi story buildings
Sure will make such videos in future
@@ElectricalInfinity thanks