As technically if the busbar Isc = 41.9kA, 50 / 63 kA for 1 sec will be ok, & also please check the O/G breaker sizes shall be more than or equal to 41.9kA but shall not be less than 41.9kA, please check..
While selecting circuit breaker, Every C.B comes with starting current and short circuit current capacity. selection of 630 A looks wrong. Please correct me if I am wrong.
Hi, your explanation is so good. We are a startup looking forward to benefit engineering students with your expertise. Can you share your email so I can send details. Thank you
Excellent teacher. Thank you so much
Electrical master 🙌 I love u so much u re good for all
U r great man bro, ur videos make easy for stones. Thank u 👍👍.
God bless you
Superb sir keep going keep helping us
Thank you sir for upload this useful video 🙏
Good job sir!
Your all videos very useful please make it one video for underground cable testing
Thank you so much Mr. V.j.balan, and i will make separate video for your request very soon
Keep support our channel
Thank you
@@electricalmastar😍😍
As technically if the busbar Isc = 41.9kA, 50 / 63 kA for 1 sec will be ok, & also please check the O/G breaker sizes shall be more than or equal to 41.9kA but shall not be less than 41.9kA, please check..
Why not choose a SC rating of 50 kA for 1 second or 63 kA for 1 second? If you choose 80 kA for 1 second, it will be very expensive to manufacture.
Great Dear. You have explained nice. Which code you have followed for this all design. Please tell me.
Great thanks sir
Thanks very much
Nice bro
to calculate motor FLC, motor efficiency also has to be considered?
Can you share your IEC reference
I think that u should have used nominal voltage of 415 volts as per IE rules & made
calculations accordingly
Dear sir,
Kindly do same topic for 33kv/11kv 2×10MVA. Tq sir
why inrush current not consider in LV circuit breaker
Dear sir,
Kindly Provide me the IEC standard for this calculation.
Regards
Hariharan
Sir the apparnt power onley used for generator and sir reactive power used for transformer sir please understand me
But in this calculation u did not consider voltage drop and amp acuity of the cable to mcc
While selecting circuit breaker, Every C.B comes with starting current and short circuit current capacity. selection of 630 A looks wrong. Please correct me if I am wrong.
Do you teach online ?
How to find impedance of the transformer
How to got 105 A
From supermarket
Hmm... IEC "rules"?
Never knew IEC imposed any rules.
If you're mentioning IEC standards, please provide the standard's reference number also.
Hi, your explanation is so good. We are a startup looking forward to benefit engineering students with your expertise. Can you share your email so I can send details. Thank you
I think that u should have used nominal voltage of 415 volts as per IE rules & made
calculations accordingly