Video is knowledgeable. ...i need complete video representation of good earth installation in home...so pls upload it...with material and equipment details
सर जी नमस्कार,आकाशीय बिजली गिरने एवं बचाव(घर एवं अन्य प्रतिष्ठान ):- के उपाय से संबंधित प्रत्येक पहलुओ के बारे में तकनीकी सामग्री,कीमत ,कृपया संपूर्ण जानकारी प्रदान करने की कृपा करेंगे,धन्यवाद सहित
Very informative and detailed video. Many of my doubt has been cleared after seeing this video and came to know that what are the main components required for lightening arrester.
Hello sir. 1.What will be the specification of copper strip?? Please mention the width and thickness 2.can I install 4 lighting arrester to one earthing rod??
Sir mera ek project hai height and spreat level measuring Ek aisa ek equipment bataye Jo earth surface se hight check kr ske Jo fully electric and wireless ho With Digital meter Plzz sir ek reply kr k kuch btaye Sir ye ek mason k liye bi bhut useful rhega kyuki phle earth surface se pipe level ka use kr k level check krna padta fir height measure krte hai Agr aisa equipment ho to btaye sir
This tech looks like shikara kalasam at top of the temple, which hindus were following since centuries. Copper material or brass. Our civilization is so advanced
Sir, self induction kya hai??,aur is kya ham free energy isse generate kar sakte hai kya, school ke phy teachers ne bataya ki magnets se free energy hota hai. Sir kya yeh possible hoga .......help
Hiii.. I am supplier of COSMOS advance Lightning protection system, it's total cost will be 1.25 Lac. Please share your enquiry to bdm.ampressbusinesinterface@gmail.com
Copper earthing for ev vehicles in detailed video make sir!! What are the raw materials required. How to charge ev vehicles through copper earthing!! And so on related electric vehicles please make video related copper earthing for ev cars in details!!🙏
Petrol tanks in Petrol Depot are not given Lightning protection. I have asked this question to the Manager of Depot but he could not answer? Will you please find out the reason?
Lighting arrester (ya surge protector) ke liye earthing ya grounding ki zaroorat hoti hai taake electrical surges ya lightning strikes se protection mil sake. Earthing ki specifications ko samajhne ke liye kuch key factors hain: **1. Earthing Conductor Size: Standards: Different standards and regulations may apply based on your country or region. In Pakistan, you should follow local electrical codes and standards, such as those provided by the Pakistan Electric Power Company (PEPCO) or Pakistan Standards and Quality Control Authority (PSQCA). General Guideline: As a general guideline, the earthing conductor size should be sufficient to handle the maximum fault current expected in the system. For most residential applications, the earthing conductor is typically between 6 mm² to 16 mm² for copper or 10 mm² to 25 mm² for aluminum. Lightning Protection Systems: For lightning arresters, the earthing conductor should be larger to handle high surge currents. Sizes of 16 mm² to 25 mm² for copper conductors or 25 mm² to 35 mm² for aluminum conductors are often used. **2. Earthing Rod or Plate: Material: Earthing rods are typically made of copper or galvanized steel. Copper rods are preferred for their conductivity and longevity. Length and Diameter: For effective earthing, the rod should be at least 2.5 to 3 meters long and have a diameter of 16 mm or more. If using a plate, it should be at least 60 cm x 60 cm and 6 mm thick. **3. Installation Considerations: Depth: Earthing rods should be driven into the ground at a depth that ensures good contact with moist soil. The exact depth depends on soil conditions but should be at least 2.5 meters. Soil Conductivity: The effectiveness of earthing depends on soil conductivity. If soil is not very conductive, you may need to use a larger rod or multiple rods. Connections: Ensure that connections between the earthing conductor and the rod are secure and properly made to prevent resistance and potential faults. **4. Testing: Earth Resistance Testing: Regularly test the resistance of the earthing system to ensure it is below the acceptable threshold, which is usually less than 1 ohm for lightning protection systems. Maintenance: Periodic checks and maintenance of the earthing system help ensure it remains effective over time. Summary: For lightning arresters, the earthing conductor should be larger to handle high surge currents, with sizes around 16 mm² to 25 mm² for copper. The earthing rod should be long enough (at least 2.5 meters) and properly installed. Always refer to local standards and codes for precise requirements and consult a professional for installation and testing.
Video is knowledgeable. ...i need complete video representation of good earth installation in home...so pls upload it...with material and equipment details
thank you very much sir for your good information
🙏🙏🙏
सर जी नमस्कार,आकाशीय बिजली गिरने एवं बचाव(घर एवं अन्य प्रतिष्ठान ):- के उपाय से संबंधित प्रत्येक पहलुओ के बारे में तकनीकी सामग्री,कीमत ,कृपया संपूर्ण जानकारी प्रदान करने की कृपा करेंगे,धन्यवाद सहित
Sar Jo badi badi building hoti hai use se earthing ka distance kitna ho na chiye Deewar se?
What is cost for seven floor bldg
The outer look is explained . The main thing which is earthing , u said about the chemicals didn’t mention any of those . Anyways will google it .
Very informative and detailed video. Many of my doubt has been cleared after seeing this video and came to know that what are the main components required for lightening arrester.
Hello sir.
1.What will be the specification of copper strip??
Please mention the width and thickness
2.can I install 4 lighting arrester to one earthing rod??
Very good information sir ji.Thank you.
Electrical Drawings and Symbols k videos bhi banaiye
.
TH-cam pe iske videos bahut Kam he
So nice so informative video bro
Good thanks very nice video
lighting arrester ki range kitna hay...matlab ek system kitna lagana padega ek building me
Sir ham ghar ka or active lighting ka rad aktho lagay to hoga
Sir TOP 244yn ki family kitni hai aur Kon sa best hai 12v 12amp ka smps ka leya ?
More video please more video every day
Very important vedio
Very good learning from u
Plz discuss about class 1 and class 2.lintning system. Where it use and why.plz sir.
SIR PLZ EK video Torque and excitation ke bare me with example banayiye plz
Sir can we use use it in open area like farm and how much distance should single rod cover in open farmland
Bhai kiya ground RoD se, current collection hoo payaenge🤔
Yes
Sir mera ek project hai
height and spreat level measuring
Ek aisa ek equipment bataye Jo earth surface se hight check kr ske Jo fully electric and wireless ho
With Digital meter
Plzz sir ek reply kr k kuch btaye
Sir ye ek mason k liye bi bhut useful rhega kyuki phle earth surface se pipe level ka use kr k level check krna padta fir height measure krte hai
Agr aisa equipment ho to btaye sir
This tech looks like shikara kalasam at top of the temple, which hindus were following since centuries. Copper material or brass. Our civilization is so advanced
क्या जरूरी है सर उसी पर गिरे उसके बगल भी गिरवी सकती है
Nice video sir
Sir iam waiting for your video👍
Sir, self induction kya hai??,aur is kya ham free energy isse generate kar sakte hai kya, school ke phy teachers ne bataya ki magnets se free energy hota hai. Sir kya yeh possible hoga .......help
Nice video sir 👍🏻
Bro very informative
sir, best ground for outdoor copper cabinet, rectangular or triangular ,
Sir aap LPS installation bhi krte ho kya?? I wanna how much it will be cost?? I face a lot of damage loss from lightning. Please reply.
Thnxx 💐💐🙏🙏
Hiii..
I am supplier of COSMOS advance Lightning protection system, it's total cost will be 1.25 Lac. Please share your enquiry to bdm.ampressbusinesinterface@gmail.com
Sir Kya Ye Mobile Tower Pe Bhi Reheta Hai🤔
Yes
Copper earthing for ev vehicles in detailed video make sir!!
What are the raw materials required.
How to charge ev vehicles through copper earthing!!
And so on related electric vehicles please make video related copper earthing for ev cars in details!!🙏
Will try
@@NiketShahPlushow many days left for copper earthing for ev vehicles????
good informatio
Nice video 👍👍👍
Itna high AMP flow korne ke liye actually kitna sq mm conductor chiye? Eyse keise possible hai🤔🤔🤔
Minimum 70mm cable or 25x3 mm copper busbar
70 mm Sq copper cabale
Copper strip plate certainly will be cut away , instead of copper aluminum plates / strip is also seen to be used.
Sir apka vidios best hai
Niket ભાઈ તમે વિજળી વિશે બહુ જ સરસ વાત કરી...પણ મને એ વાત ની મુંઝવણ છે કે આ રોડ અને કેબલ ઓછામાં ઓછું કેટલા mm નુ જોઈએ
Petrol tanks in Petrol Depot are not given Lightning protection. I have asked this question to the Manager of Depot but he could not answer? Will you please find out the reason?
No idea
Very good, thank you sir
Very informative video thanku sir
Very useful information about earthing.
Very good👍
Thank you! Cheers!
Can we connect 2 lightening arrester to the same Lightening earthing rod ?
yes
Thank you sir good knowledge
सर मेरे घर से 600 मीटर दूर मोबाइल टावर है तो क्या ये सिस्टम मुझे लगाना होगा
Pura Seth kitne me Kagta hai 🙂
Hi,
I am planning to do this GI pipe earthing near my plastic water tank,
Will it be safe for us in future?
Please reply
Yes
Are lightening systems (if installed properly) guaranty for protection from lightening?
99%
Good information !
Kindly if you know any tech.party,who have involve for installation of LPS(New),provide the contact no.
Kaha milega kripya bataye
Please explain why lighting rods are provided in conical shape fom top?
Ajoy sarkar i want more detsils larning sir plz
Video itna kam kyu upload kar rahe hey sir ggg
Ok
Thank u very very much Ok
Thank u very very much
welcome.. do share this video with others as well
Ye to eric cartman aur kyle ga ghar he
Sir from where I can buy
Earthing wire kya size ki Leni chahiye please tel me
70 mm copper cabale
Thank you vai
Do share this video with others
Sir aap modeling sikha sakte hai
Rod ka price kitna
we are not in sales
Total kitne rod lagane ka
Depends upon your load
why lightning arrester spike is too edgy
Hii
Rate kya h. ?????
No idea
Its learning
hi
Hi
Lightning arrestor
Sir number
Ceiling Fan Winding class hots ha
induction or electricity leke thoda sa v knowledge nahi hai tujhe...ulta pulta bola ja rha hai
Irth wir mm
Lighting arrester ke liye earrings kitna hona chahiye
Lighting arrester (ya surge protector) ke liye earthing ya grounding ki zaroorat hoti hai taake electrical surges ya lightning strikes se protection mil sake. Earthing ki specifications ko samajhne ke liye kuch key factors hain:
**1. Earthing Conductor Size:
Standards: Different standards and regulations may apply based on your country or region. In Pakistan, you should follow local electrical codes and standards, such as those provided by the Pakistan Electric Power Company (PEPCO) or Pakistan Standards and Quality Control Authority (PSQCA).
General Guideline: As a general guideline, the earthing conductor size should be sufficient to handle the maximum fault current expected in the system. For most residential applications, the earthing conductor is typically between 6 mm² to 16 mm² for copper or 10 mm² to 25 mm² for aluminum.
Lightning Protection Systems: For lightning arresters, the earthing conductor should be larger to handle high surge currents. Sizes of 16 mm² to 25 mm² for copper conductors or 25 mm² to 35 mm² for aluminum conductors are often used.
**2. Earthing Rod or Plate:
Material: Earthing rods are typically made of copper or galvanized steel. Copper rods are preferred for their conductivity and longevity.
Length and Diameter: For effective earthing, the rod should be at least 2.5 to 3 meters long and have a diameter of 16 mm or more. If using a plate, it should be at least 60 cm x 60 cm and 6 mm thick.
**3. Installation Considerations:
Depth: Earthing rods should be driven into the ground at a depth that ensures good contact with moist soil. The exact depth depends on soil conditions but should be at least 2.5 meters.
Soil Conductivity: The effectiveness of earthing depends on soil conductivity. If soil is not very conductive, you may need to use a larger rod or multiple rods.
Connections: Ensure that connections between the earthing conductor and the rod are secure and properly made to prevent resistance and potential faults.
**4. Testing:
Earth Resistance Testing: Regularly test the resistance of the earthing system to ensure it is below the acceptable threshold, which is usually less than 1 ohm for lightning protection systems.
Maintenance: Periodic checks and maintenance of the earthing system help ensure it remains effective over time.
Summary:
For lightning arresters, the earthing conductor should be larger to handle high surge currents, with sizes around 16 mm² to 25 mm² for copper. The earthing rod should be long enough (at least 2.5 meters) and properly installed. Always refer to local standards and codes for precise requirements and consult a professional for installation and testing.