Top 10 Circulator Pump Problems Found on Boilers!

แชร์
ฝัง
  • เผยแพร่เมื่อ 20 ก.ค. 2024
  • 10 Problems that Occur in Boilers that are the Circulator Pump or a Related Problem that the Circulator is Blamed for. I Discuss and Show Noise, Troubleshooting, Leaking Water, Bearings Locked, Testing the Motors, Capacitors, Air Locks, and Processes. Supervision is needed by a licensed HVACR Tech while doing this as Experience and Apprenticeship garners Wisdom and Safety.
    Tools Used In The Video
    UEI DL479 Multimeter With Temp Sensor amzn.to/2jtsUbJ
    Alligator Jumpers- amzn.to/2PxqJXn
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Our Related Videos
    • Taco Zone Valve Relay ...
    ttps:// • 4 Wire, 5 Wire Honeywe...
    • Taco Zone Valve Wiring...
    • Testing, Wiring, Taco ...
    • Taco 6 ZONE Switching ...
    • Installation of a Tank...
    • Boiler Training Class,...
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Our HVACR Educational Books, E-Books, Workbooks, Cards, Posters, and PowerPoints:
    All Our Educational Products on Our Site: www.acservicetech.com/store
    All Our Educational Products on Amazon: amzn.to/48pDd82
    Mini Split Book and E-Book on Our Site- www.acservicetech.com/mini-sp...
    Mini Split Paperback on Amazon- amzn.to/3ytHJSs
    Mini Split Paperback on TruTech Tools- www.trutechtools.com/BooksGui...
    Refrigerant Charging Book and E-Book: www.acservicetech.com/ac-book
    Refrigerant Charging Paperback on Amazon: amzn.to/46xTeHf
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Our HVACR Online Resources!
    Our HVAC Calculators: www.acservicetech.com/hvac-ca...
    Our Newest Articles: www.acservicetech.com/articles
    Try our HVAC/R Quizzes! www.acservicetech.com/quizzes
    Our Other Resources: www.acservicetech.com/resources
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Tools Used in Our Videos!
    Tool Links on Our Site: www.acservicetech.com/tools
    Our Tool List on Amazon: www.amazon.com/shop/acservice...
    Support the Channel by purchasing tools through TruTech Tools!
    Use this link www.trutechtools.com/?aff=8
    Save 8% at checkout using code "acservicetech"
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Follow Us On Our Social Media & Podcasting Channels!
    Patreon: / acservicetech
    Facebook: / acservicetech
    Instagram: / acservicetech
    X: / acservicetech
    LinkedIn: / ac-service-tech-llc
    Tiktok: / acservicetech
    Spotify: open.spotify.com/show/74KXLz5...
    Apple Podcasts: podcasts.apple.com/us/podcast...
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    ⚠️ Disclaimer:
    Information in this video is intended for educational purposes only. Any work related to the topics in this video should be performed by licensed technicians or by apprentices under the supervision of licensed technicians. AC Service Tech LLC is not responsible for any possible damages or injuries caused by the use or misuse of any information provided.
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    #hvacr #hvacr #hvacr #hvactrainingvideos #hvactraining #hvactraining101 #acservice #hvacproblems #boiler #circulator #noise #troubleshooting #leaks #motor #testing #capacitors #airlocks
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Shop through Amazon! Your Purchases through Amazon provide a means for channels such as mine to earn advertising fees from all purchases after clicking through. Prices are the same as normal.

ความคิดเห็น • 117

  • @acservicetechchannel
    @acservicetechchannel  5 ปีที่แล้ว +6

    Support- www.patreon.com/acservicetech
    Tool List- www.amazon.com/shop/acservicetech
    For those that are looking for the tools used in the videos: (Linked Below)
    UEI DL479 Multimeter with temp sensor amzn.to/2jtsUbJ
    Valve Core Removal Tool amzn.to/2uYr8WL
    Blue Vapor Yellow Jacket Gauge- amzn.to/2Ju7pan
    Red Liquid Yellow Jacket Gauge- amzn.to/2sSFmGH
    Quick Coupler for the Gauges- amzn.to/2sTk8Ze
    JB Test Gauge High Side- amzn.to/2ruQb0l
    JB Test Gauge Low Side- amzn.to/2qR0utM
    Manual Copper Tube Swage/Expander- amzn.to/2WRPa1M
    Uniweld Hydraulic Swaging Tool- amzn.to/2MlrI8m
    Uniweld Swage and Flare Kit- amzn.to/2T55jyn
    Ameriflame Oxy Acetylene Torch Setup- amzn.to/2SRm3JF
    #2 Tip for Oxy Acetylene Torch- amzn.to/2SPDaeD
    Cap-N-Hook Tip for Oxy Acetylene- amzn.to/2MbhpUk
    Air Acetylene Torch Setup- amzn.to/2aQalsb
    15% Silver Brazing Rods- amzn.to/2gVLyLc
    Nitrogen Regulator- amzn.to/2bXdR5f
    Nitrogen Flow Meter- amzn.to/2brvoBg
    NitroVue Flow Reg- amzn.to/2MiulYv
    Ultrasonic Leak Detector- amzn.to/2Lw4Zpr
    UEI DL479 Multimeter with temp sensor amzn.to/2jtsUbJ
    Magnet Jumpers- amzn.to/2PyKPQZ
    Alligator Jumpers- amzn.to/2PxqJXn
    Fieldpiece ST4 Dual Temp Meter amzn.to/2wc1ME3
    Fieldpiece Bead K Type Temp Sensor amzn.to/2DBwKfs
    Fieldpiece Wet Bulb Temp Sensor amzn.to/2RRI7Tw
    Fieldpiece TC24 Temp Clamp amzn.to/2qHLyjZ
    Yellow Jacket Refrigerant Gauge Set amzn.to/2aenwTq
    Refrigerant hoses with valves amzn.to/2aBumVI
    Yellow Jacket Gauge set & hoses amzn.to/2vLVkV9
    Yellow Jacket 4 Port Manifold w Hoses amzn.to/2BkuGIq
    FieldpieceSMAN360 Digital Manifold Set amzn.to/2BdoaD4
    FieldpieceSMAN460 Digital Manifold Set amzn.to/2nB4Fe6
    Compact Ball Valve for Refrigerant Hose amzn.to/2KUisW8
    QuickDisconnect 90 for refrigerant hose amzn.to/2MMtVcg
    JB 6 CFM Vacuum Pump amzn.to/2nqbvo8
    Appion Blue 3/8" to 1/4" Vacuum Hose amzn.to/2uYlVyc
    Appion Red 3/8" to 1/4" Vacuum Hose amzn.to/2uYg6Ro
    Appion Valve Core Removal Tool amzn.to/2uYr8WL
    Yellow Jacket 1/4" by 1/4" hose amzn.to/2umtcod
    CPS Vacuum Micron Gauge amzn.to/2v1nM3O
    Supco Vacuum Micron Gauge amzn.to/2v1JRiA
    RectorSeal Bubble Gas Leak Detector amzn.to/2ckWACn
    UEI DL389 Multimeter amzn.to/2xAdaJf
    Other tool links can be found in the video description section.
    Shop through Amazon! Your Purchases through Amazon provide a means for channels such as mine to earn advertising fees from all purchases after clicking through. Prices are the same as normal- www.amazon.com/shop/acservicetech

  • @derrickherndon9993
    @derrickherndon9993 2 ปีที่แล้ว +4

    This was so incredibly helpful. Very thorough and clear. Last year I had an impeller that was stuck. Manually turned it to free it. This year it was a sticky relay (problem #6). Thought at first it was air in the lines as I turn off water to that heater in the summer so that hot water is not always providing a heat source in that room. Drained the line but no joy. Pump not running but impeller turning was the hint. I just tapped the relay after removing the cover and the pump engaged. Will see if the relay returns to normal switching. This is a Grundfos pump with the access port as shown above. Thank you so much for helping us DIY home owners.

  • @danielbaldwin8260
    @danielbaldwin8260 3 ปีที่แล้ว +6

    Excellent diagnostic and repair presentation. I was able to get major air pockets removed by the fill and bleed method and provide heat to the upstairs apartment. Thanks for saving me money, time, and wasted efforts.

  • @luiselizalde6757
    @luiselizalde6757 5 ปีที่แล้ว +4

    As always, very good quality videos, I really appreciate them. Thanks teacher. Keep making those videos.

  • @jfmc2581
    @jfmc2581 2 ปีที่แล้ว +1

    Great video, you covered lots of issues clearly and quickly.

  • @catherinewalpole6392
    @catherinewalpole6392 2 ปีที่แล้ว +1

    This video is comprehensive and easy to understand. Thank you!

  • @mikeallen2097
    @mikeallen2097 2 ปีที่แล้ว

    Great video. Excellent information. Thank you very much for posting! Looking forward to more.

  • @lalac6095
    @lalac6095 4 ปีที่แล้ว +1

    Thank you for this. You just kept me from having to get up every hour and switch zones for my heat ;) bled the line and it works like a charm. ❤️

  • @tongyang1631
    @tongyang1631 ปีที่แล้ว +2

    thank you so much for all the tips. I'm a handy man but my expertise is in automobiles and carpentry. this probably saves me hundreds of dollars on my first personal diagnosis.
    I don't have a fill valve but I do have two valves that fit a garden hose. One after the circulator and one on the bottom. I will try to fill it. last year it worked well but I could hear air in my system. thank you for giving me a chance at messing with it. something so simple but I just couldn't figure how to fill without a valve

  • @jashua2089
    @jashua2089 2 ปีที่แล้ว +1

    Amazing information, keep up the good work master.

  • @jackjenkins6305
    @jackjenkins6305 3 ปีที่แล้ว +1

    Really enjoyed your video/s. you are a great instructor, so keep up the good work!

  • @Unknown-qt9cv
    @Unknown-qt9cv 9 หลายเดือนก่อน

    Thank you so much. Amazing explanations and demonstrations. VERY helpful

  • @richardcaro3368
    @richardcaro3368 4 ปีที่แล้ว +1

    Thank you so much I learn so much from your videos keep up the great work

  • @Nokyai
    @Nokyai ปีที่แล้ว

    Excellent video and clear explanation! Thank you very much!

  • @kevinkamel3158
    @kevinkamel3158 10 หลายเดือนก่อน

    Great presentation. Thank you so much for taking the time to create videos like this.

  • @integrity5264
    @integrity5264 3 ปีที่แล้ว +2

    you covered everything, thank you, well done

  • @stephenalibozek1058
    @stephenalibozek1058 3 ปีที่แล้ว +2

    Very good explanation of how to search for the problem 👍👍

  • @crooktube
    @crooktube 5 หลายเดือนก่อน

    Great video! I ended up buying a new one, but with this video I had the confidence to do it myself and that saved me so much money and maybe even saved me from a new boiler this year! Just got quoted for a new boiler.... $20K!!! Cheers!

    • @Stil1_loading
      @Stil1_loading 5 หลายเดือนก่อน

      what was he replacing radiators too?

  • @heatncool
    @heatncool 5 ปีที่แล้ว +4

    good video. nice! I've devoured your videos for the last year doing residential but since I got into commercial hvac, im working with boilers, cooling towers, vav boxes, water cooled condensers, chillers. Good video thnx!

  • @lesio333
    @lesio333 4 ปีที่แล้ว

    Very detailed and educational video, thanks :)

  • @rinamackeeman4376
    @rinamackeeman4376 5 หลายเดือนก่อน

    Really great video. You’re a good teacher

  • @carlblack8900
    @carlblack8900 5 ปีที่แล้ว +2

    Another awesome video!

  • @dpalexander
    @dpalexander 2 ปีที่แล้ว +1

    Very nice! Wondering if you have encountered a pulsing in the pump (primary), frequency approx 10 times per second, pressure surges at same frequency approx 3 psi, audible upstairs. Any suggestions? Bad bearings, blockage? The system is only 6 years old.

  • @shinylight7705
    @shinylight7705 2 ปีที่แล้ว +1

    Thanks for the video

  • @jimmittler6344
    @jimmittler6344 8 หลายเดือนก่อน

    Excellent, thank you for covering everything

  • @leodavis7524
    @leodavis7524 2 ปีที่แล้ว

    Very well explained 👍

  • @manismello
    @manismello 3 ปีที่แล้ว

    You’re very welcome...I’ll keep In touch!

  • @user-ib5qi8ek2z
    @user-ib5qi8ek2z 3 ปีที่แล้ว +1

    Thank you for these informations.
    Can you tell me what should be the circulation pump’s body temberature while working?
    Since I found it very very hot when I touch it,
    Thanks

  • @kenwiltshire7834
    @kenwiltshire7834 3 ปีที่แล้ว +1

    Fantastic, Thanks so much.

  • @natashariley9226
    @natashariley9226 2 ปีที่แล้ว

    ThankYou for Sharing this invaluable information. Can A Grunfos Alpha 2 circulating pump work with a Burnham boiler?

  • @ThePachucoMix
    @ThePachucoMix ปีที่แล้ว

    Thanks 🙏 I need more videos of Boilers

  • @PBS-nm1uu
    @PBS-nm1uu 5 ปีที่แล้ว +2

    just found this video just keep them coming, do you have any on radiant heating ??

    • @acservicetechchannel
      @acservicetechchannel  5 ปีที่แล้ว

      Thank you, just on controls such as zone valves, aquastat, zone control relay, thanks!

  • @williambauer9259
    @williambauer9259 3 ปีที่แล้ว

    You are amazing. Thank you so much!

    • @acservicetechchannel
      @acservicetechchannel  3 ปีที่แล้ว

      Glad to help Will and check out our website at www.acservicetech.com thanks!

  • @manismello
    @manismello 3 ปีที่แล้ว +1

    Very good job, sir, 👍

  • @mark-1234
    @mark-1234 4 ปีที่แล้ว

    Not sure if this is the place to ask but I have a switching relay (Honeywell RA89A) that turns on my boiler contacters but my circulating pump is wired directly to a breaker and runs 24/7. I'd like to add a surface mounted temp control (was looking at a Johnson Controls A19DAC-1C, 100 to 240 deg F) to the pump circuit. Would I need to add another switching relay to do this, or do these temp controls switch 110V on their own?

  • @micharris1761
    @micharris1761 ปีที่แล้ว

    nice video ty for it.

  • @wildman8601
    @wildman8601 4 ปีที่แล้ว

    Craig what's best side for a circ pump to be on a boiler coming off the supply side or coming off the return side

  • @Wiggles1
    @Wiggles1 3 หลายเดือนก่อน +1

    Just SUPERB 😀

  • @juliorodriguez8863
    @juliorodriguez8863 ปีที่แล้ว +1

    Thanks!

  • @armandotorres626
    @armandotorres626 5 ปีที่แล้ว +1

    I had a grundfos airlocked and was able to bleed out the air through the same access used to unlock the motor. Is that there for air bleeding purposes as well?? Great vids, long time subscriber...

    • @acservicetechchannel
      @acservicetechchannel  5 ปีที่แล้ว

      Not necessarily because the hole is not built out to the end of the casing but could be done if needed, thanks!

  • @yoman5136
    @yoman5136 4 ปีที่แล้ว +1

    When my unit, four zones, was built two guys did the work. Looking at the first thing the B team guy did, I told the A team guy that I’m going to have to look at this system for a long long time. So the A team guy sent b guy off doing other stuff. A guy built a great four zone manifold system that was, “Instrument Fitter” quality work, perfectly plumb and level and square. . The B team guy soldered pipes out in the zone manifolds and used an old worn wire brush cleaning the insides of the copper pipes. We ended up opening the system at the pumps taking out broken wires from an old worn out soldering brush the dummy brought with him !

  • @thesetruths1404
    @thesetruths1404 3 ปีที่แล้ว

    Nice Instructional video! Thanks. Do you think Grundfos pumps are as good or better than Taco? I like how Grundfos has the shaft testing access.

  • @galenwaltman1656
    @galenwaltman1656 3 ปีที่แล้ว +3

    What would cause one zone to continuously circulate?

  • @ryans413
    @ryans413 3 ปีที่แล้ว

    My building I live in uses water heating and that pump they had was so noise you could hear it vibrating through the baseboard heating. Landlords finally got some guys in to replace it now it’s so silent I’m not use too it lol. I still hear little buzzing but not really loud anymore. Mostly just hear the water moving

  • @jackjenkins6305
    @jackjenkins6305 3 ปีที่แล้ว

    The thermostat electrical connector caps were touching making the Fasco blower, and possible the Taco Cartridge circulator continues to run until I pull the caps away from each other, then the blower stopped.
    Question: could there be a bad wire inside the connectors or can electric caps insulation go bad?
    I am thinking of having an electrician totally rewire the thermostat wiring from the house thermostat to the boiler control unit.
    Any thoughts or suggestions are appreciated?

  • @YTsux24-7
    @YTsux24-7 5 ปีที่แล้ว +2

    Good stuff as always sir!

  • @edgarkube3753
    @edgarkube3753 2 ปีที่แล้ว

    I recently purchased a outdoor boiler with 2 water circulator output. One is ging to the house one to my shop. Both have circulation pumps. Nrf 25 to the house and nrf36 to the shop. That's bell gossett pumps. The one to the house works quiet and the one to the shop is working relatively laud. The laud one sounds like it has air inside the pump. I drained the line back into the boiler with a garden hose and pump running. But that didn't solve the problem. Is it possible that the pump itself got weak? Or inside damage so it creates vaccum/air within the pump that gets pushed into the system?

  • @jerseyshoredroneservices225
    @jerseyshoredroneservices225 7 หลายเดือนก่อน

    Some recirculating pumps have a flow check built in, correct? What happens if that gets gunked up or fails some other way? I have a very simple hot water system that first wouldn't make heat even though the hot water heater was hot. There was an inline flow check valve that was gunked up. Changing that out fixed the problem but also created a new one. With the new valve installed that heat just won't stop even with the thermostat turned off.
    Since that flow check valve was replaced the hot water seems to be circulating on its own due to and the heat inside here just won't stop.

  • @koh9894
    @koh9894 4 ปีที่แล้ว

    Please HELP!!
    Bell and Gossettt Series #100
    Power getting to the pump: 122V
    Pump motor not turning with power but seems to turn freely with my screwdriver.
    I did try the Resistance test. I think I got 0.L (gonna look again)
    Electrical windings fried ??

  • @hdavey72
    @hdavey72 3 ปีที่แล้ว +1

    Good stuff

  • @CraftMMORPGs
    @CraftMMORPGs 3 ปีที่แล้ว

    Can we do an amp draw test to see if the pump is running?

  • @natashariley9226
    @natashariley9226 2 ปีที่แล้ว

    The floors are vibrating can the new circulator pump be the issue?. Floor was not vibrating prior to installing the new pump. Please advise. ThankYou

  • @Alex-jo2oi
    @Alex-jo2oi ปีที่แล้ว

    I came across one where the pump assembly is rotting out. Roughly 10 years old. Is this due to lack of maintenance, and proper draining of the lines every so often?

  • @techmasterflash
    @techmasterflash 2 ปีที่แล้ว

    Call for heat… fan comes on, circ pump relay on Taco 3 zone controller barely clicks. Circ pump doesn’t come on? Intermittent issue. Thoughts?

  • @4439841362
    @4439841362 2 ปีที่แล้ว

    Hi, my system is approx 10 years old. Circulator was replaced approx 3 years ago. Recently (august 2021) Why will circulator motor not shut off, thermostat is set at 40*F. Circ motor is hot. That loop is cold. I just purged the entire system (Circulator #1 in question has 2 heating zones with zone valves. Circulator #2 is for indirect domestic HW & no zone valve). Why will circ#1 not shut off?

  • @robertmicheline1551
    @robertmicheline1551 2 ปีที่แล้ว

    what do you do if it dry when you motor off felt no water in the circulator

  • @rodbutler4054
    @rodbutler4054 5 หลายเดือนก่อน

    I have replaced 4 circulating pumps over 10 years because they were running hot and probably failed prematurely. In my last replacement I surrounded the pump with strips of aluminum foil to draw away the heat and have noticed it runs cooler and more efficient.IMHO

  • @ABDELFIX
    @ABDELFIX 8 หลายเดือนก่อน

    Would a noisy circulator pump cause the pressure relief valve on the boiler to open up as well? I checked the pressure and it was around 20 psi and temperature was around 150-160 F, no problem there. So I'm not sure if the circulator pump is the problem or now I'm thinking maybe the expansion tank?

  • @Tsilsby
    @Tsilsby 2 ปีที่แล้ว

    i have a question... i bought my house a few years ago. and they system works great. the boiler was manufactured in 1963 (IIRC) its old.. but it works perfectly.
    ok my question.... i don't have zones. its all one zone.. would they have built it consecutively or would each room go to a junction and feed back to the storage tank??
    Also, there are times when it sound like water going through the radiator. like I don't think its 100% full of water...
    are they systems designed to be topped off.... or are they only filled up so much.. to make room for expansion when the water is heated...???...
    sorry this is all new technology to me... every house i have ever lived in has had force air system...
    This house also has a heat pump. with a back up heat grid... so I have 3 different ways to heat my house..
    However, its was built at the end of the 19th century. so electric is stupid expensive to heat with.

  • @michaelthompson7528
    @michaelthompson7528 2 ปีที่แล้ว

    He just saved me some money. My pump was the red pump. Went into the basement and oiled it in all three ports. NO MORE noise.

  • @vitaliisiennikov4663
    @vitaliisiennikov4663 ปีที่แล้ว

    I have Taco 007-F5-71FC right now in my system. Can you tell me please on which model can I change it which have more power? Because right now it not enough power for two floors? Thank you!

  • @Tko_Seven
    @Tko_Seven 5 หลายเดือนก่อน

    is the pump supposed to generate magnetic field as the boiler switch is on
    or
    only when the pump is actively engaging?

  • @komakon
    @komakon ปีที่แล้ว

    My problem is #5 and I guess the builder never hooked the pump up to power. It's located in a box outside on the house next to the AC unit. I have a leak from the Taco pump but I can't seem to find a new O ring anywhere, do you know where I could find one? the Model number is 006-BC5Y-1 any help is appriciated.

  • @Vmartin70EZ
    @Vmartin70EZ 7 หลายเดือนก่อน

    My circulation pump is like the one before the red one and there's no noise at all there's no current going into the motor L1 wire, no shut off valves above or below the pump housing any advice how to stop water from leaking down out when I replace it?😕

  • @ernestodiaz76
    @ernestodiaz76 ปีที่แล้ว

    Do you have a book about heating systems?

  • @annacacheiro9983
    @annacacheiro9983 3 ปีที่แล้ว

    My problem is that I cannot have both my floors heating system on, if I put on the 1st floor, my second floor shuts off and vice versa. Any suggestions would be greatly appreciated

    • @bpdp379
      @bpdp379 ปีที่แล้ว

      It may be setup to use a priority zone.

  • @jackieb8998
    @jackieb8998 3 ปีที่แล้ว +1

    What kind of oil should I use for a circle pump like the red one you showed around @8:43 the larger one?

    • @acservicetechchannel
      @acservicetechchannel  3 ปีที่แล้ว +1

      zoom spout oil, thanks!

    • @jackieb8998
      @jackieb8998 3 ปีที่แล้ว

      @@acservicetechchannel thank you for letting me know! My pump stopped making the humming noise instantly.

  • @josepeixoto3384
    @josepeixoto3384 ปีที่แล้ว

    video from a pro, we can tell; thanks

  • @robinjoly9262
    @robinjoly9262 2 ปีที่แล้ว

    My pump was not circulating water and was making a very high pitch squeeling sound. With online help from a relative, I was advised that the impeller was likely stuck and the high pitch sound was the shaft spinning. He said try hitting it with a wrench to get it spinning, which I did. The impeller then was spinning again and water was circulating. I believe this problem was caused because a repairman left my water supply off after a small leak repair. It was off for almost 2 weeks. Does anyone think that this pump is now compromised and that the company should pay to replace this pump?

  • @jstavene
    @jstavene ปีที่แล้ว

    Out of curiosity if you have say 4 zones and 1 zone does not have water at a bleed valve, is it possible there is no water because the circulator pump locked up? or would it be more likely the bleed valve is not working? (its -26 ) and I am not taking the boiler offline or changing water if I can help it and everything else seems fine and working?

    • @sirhc07
      @sirhc07 ปีที่แล้ว +2

      More than likely the zone was frozen for that extreme cold weather

  • @daveschooley8514
    @daveschooley8514 2 ปีที่แล้ว

    I have a taco 0011-f4 pump, can the impeller get worn down and only pump a small amount, about 3 pm? How can I tell what the problem is?

    • @bpdp379
      @bpdp379 ปีที่แล้ว

      Cavitation can definitely wear an impeller down to nothing.

  • @dovikel
    @dovikel ปีที่แล้ว

    I wonder - in a 4 zone boiler - can defective circulator pump do the job for 3 zones and not to the forth zone?

  • @MustPassTruck
    @MustPassTruck 4 ปีที่แล้ว

    I'm fine turning wrenches, but the stuff with angry fairies always throws me off.

  • @rtta51
    @rtta51 3 ปีที่แล้ว

    Can't find anyone who sells just the Taco motors.

  • @faroyoussef1757
    @faroyoussef1757 2 ปีที่แล้ว +1

    Guys why there is a flow of electricity everywhere in the boiler except the pump??

    • @Alex-jo2oi
      @Alex-jo2oi ปีที่แล้ว

      Faulty ground somewhere? I’d definitely call out an electrician.

    • @caru3257
      @caru3257 ปีที่แล้ว +1

      @@Alex-jo2oi Aquastat likely bad if boiler is at high limit temperature.

  • @Tsilsby
    @Tsilsby 2 ปีที่แล้ว

    I have the larger red style pump. when i bought my house the seller showed me how to oil they system.. but he only showed me the 1 oil port on the propeller. learn something new every day.
    now to replace the o ring cause its leaking at the flange....

  • @sportykev
    @sportykev 3 ปีที่แล้ว

    Exactly what I needed, believe my impeller is seized in the Taco Circulator Pump. Hit it with a hammer worked...

    • @pmny3423
      @pmny3423 3 ปีที่แล้ว

      The old caveman method. Might have to try that out on mine.

  • @q7jdwomfvkbj74
    @q7jdwomfvkbj74 2 ปีที่แล้ว

    12 to 15 psig cold
    20 to 22 psig hot

  • @jde1780
    @jde1780 2 ปีที่แล้ว

    We're always thankful for the information you share, but It would be *much* better if you used the term "Micro Farad", instead of "UF".
    Even though we understand, the Unit Of Measurement is microfarads, not UF's. It's the same as the movie Back To The Future: He uses the term "Jigga-Watts" instead of "Gigawatts".
    You'll be teaching the incorrect unit pronunciation/terms to new students.
    Regardless of my pet peeve, thanks for sharing.

  • @schloshyjea1
    @schloshyjea1 ปีที่แล้ว

    UF is pronounced microfarad :)

  • @Yourengineeringstandpt
    @Yourengineeringstandpt 3 ปีที่แล้ว

    Sleeve pump cartridge replacement you didn't show them that that's what you do k your welcome?!!!

  • @zeez4178
    @zeez4178 3 หลายเดือนก่อน

    Solutions 😡?

  • @seg83423
    @seg83423 3 หลายเดือนก่อน

    youtube algorithm