hello mr.zia i have a 3.kv home generator is is starting runing but after one minutsits sound change and big noise from cylenser and stoped so please can u help me about this it was runing well sudenly happen this
Sorry bhaye mere pass 3 kv ka generator he achee halat me he aajkal usmea kuch kharabi hugayee he ke start huneke 5 ya 7 minut ke baad band hujata he plugh bhee chang kerdiya. Shukria aapke jaldi jawab ka iska kuch hal bataean meherbani hugi. Iqbal. Karachi
Ye prbm zyada tar current coil ma hoti ha Plug ki led jis coil sy nikal kar aarhe ha is coil ko current coil , lgntion coil b bolty hn Ap ye coil new laga do IN SHAA ALLAH Ap ka generator set ho jay ga
Bhai thik ho Gaya hai Mobil patla ho Gaya tha molil Chang kardi our caburetor me eak adjustable scrow hota hai o scrow Tait Kar di to load 2000w Lene Laga thanks bhai aap bahut gaid di thanks
KHALID AHMED ASA Sir generator course programe mein episode no 8 ring or piston ka tariqa bataya tha aur ring aik maqsoos tareeqe dale the apne koi khas waja agar ring ke setting thori se age peche hogae to koi haraj tu nahi hai kindly reply as soon as possible. Thanks
W/salam Rings ka gap 1 dosry sy kam sy kam 45 degree tak lazmi hona chahye Or zyada sy zyada 90 degree 90 degree 1 gap sy 2nd gap k bilkul opposite hota ha To opposite par set kar do Agr setting thori bth age peche ho jay to b 45 degree sy he zyada he rhy gi Is lye 90 degree pr set kar dena theak rhta ha
Naveed Murad Welcome to my TH-cam channal Bhai start na ho to ap plug ko thory sy petrol sy saaf kar k plug ma spark check karo agar spark theak ha to phr petrol par start kar k dhkho Agar start ho jay to theak hn Nhi to kick ko out kar k flywheel ko hat sy aram sy ghomao flywheel 1 hesy par jaam ho ga or baki 3 heso par free ho ga Full free ho to tappit ki prbm ha Agar 1 hesy pr jaam to phr theak ha Ye check karo
Greetings from America, seems like a risky Way to damage the slip rings. Why not try Threading a slide hammer into the end and pound it off . Like a 5-10 lb one auto mechanics use , I dunno 🤷♂️
Nhi ab ma koi video upload nhi kr rha hn Bs private ma kisi ko help chahye to wo bs WhatsApp pr video send kr deta hn Bs Wo is lye k machine k pass b log jay Ye video b bht ha jo mane upload ki ha
Brother Mere 2.5KVA Generator Ka AVR istri ki tarrhan garam ho ke kharab ho raha 2 change kar chuka 2 din mai or voltage bhi low or unstable hain. Winding check ki hai series pe shortage bhi nhi hai or ohm meter pe rotor ki resistance 8 se 10 ohm hai or stator ki bhi 14 se 20 ohm ke qareeb hai . Kia waja ho sakti hai help me
Very nice video but ak problem hota hay o ki kavi kavi engine ka oil me kerosene a jata hay a kiu hota hay eska solution kayse kore please eska Jan kari dia to bohut help hoga
sir zia ap ne bht behtreen vedios banye he bht bht shukria. sir mera 2.7kva ka genrator he but over load hone ki waja se wo petrol pe to start hojata he but jab gas pe krte hein to bnd hojata he plase guide me
Ap full service kr lo generator ko Carburater rokar plug filter in sb ko petrol sy dho kr dobara fit kr k new setting kr lo IN SAHH ALLAH set ho jay ga
instead of hittng the bearing with a hammer you should find a rod that will fit into the hole so if you cut a few long bolts of a slightly smaller D smaller than the original rod then feed them into the hole until they fill the space but go past the original thread now screw a bolt of the correct thread or the original behind them - they will act as a puller as the bolt pushes them on the taper sharft and the rotor will pop off. if that sounds complex you should basically get a rod that will go in the hole and sit just behind the thread you undone - then screw a bolt in onto that rod the rod will push on the shaft and the rotor will pop off.
often they won't have threads on the end of the rotor and it could (and has once for me) cause ther rod to get squished and stuck inside the hammer method is believe it or not safer
anon-iraq if you make sure the rod is sufficient in diameter then you can simply cut it to the length to fit behind the original screw that goes in behind the rotor, then screw the original screw / bolt in behind it or if it has no thread another bolt of the same type there is not a chance it will ‘squish’ if you use a normal steel rod , and there is always a thread where the original rod goes at the back of the rotor, your net cost is some steel rods and maybe a bolt at different lengths as opposed to hitting the rotor with a hammer which will be jamming angular pressure onto the bearing that is supporting it.
Mere pass ek petrol in generator uska jo magnet Mota hai bahut jaam chal raha hai free chalne ke liye kya aur Mota utar dene per generator Mera Sahi chal raha hai promoter is bar FIR kahate Hain to uske bad pura Jaan chal raha please sirbataiye
Sorry bhai Ye 1 alag kam ha Ye kam rewinding waly karty hn Mje is ka nhi pata Or na he koi batata ha Mje engine ka kam pata ha bs Agar rewinding karwani hoti ha to wo hum dosro sy karwaty hn
Filer ma oil aany ki 2 waja hoti hn 1 to tappit cover k khrab hony sy asa hota ha 2nd rings k gis jany sy gap ki waja sy air engine ma zyada jati ha or ye air out hoti tappit cover sy or is cover ma 1 paip filter cover ma aata ha isi paip sy presser ki waja sy oil b aajata ha
Bhai Jan mera genrator chal raha hy lakin light pass nhi kr raha hy phly b 125 ki bettry say shock diya ta per light pass kr raha ta lakin mujhe bettry shock dy nahi ata plz ek video banao kesay shock diya jata hy
Wesy ye AVR ki kharabi ki waja sy ho rha hota ha Apa agar shock nhi de sakty ho to is ka 1 hal ye b ha k ap governor arm ko hat sy carburetor karo to is sy speed tez hoti ha Bth bar asa hota ha k speed ki jhatkay sy light aajati ha
Ye valve ki prbm hoti ha Mtlb ap ko head open kar k valve ko theak sy saaf kr k lagao Agar valve ma zyada prbm ha to ap ko new valve lag wany pary gy Valve ma seat or duide hoti hn Ye lath machine wala set kr k de ga Ap ye kam karwa lo
Mje whatsapp pr generator ki mobsy choti c video bana kr send karo ma dhkhta hn +92 312 3902109 Is num pr bhje dena video Us k bad dhkhty hn valve ki prbm ha ya nhi
G bhai generator ki har 1 chez mil jati ha market sy new Or 2nd hand b mil jati ha Rewinding karny wali shop pr rotor or stater 2nd hand aram sy mil jaty hn Or ap usi shop pr apna old rotor or stater seal b kar sakty ho Ap ko shop waly sy bat karni pary gi har koi alag alag rate lagata ha Agar ap new rotor or stater lena ch rhy ho wo b mil jata 2.5 ka 8000 sy 9000 tak ma mil jata ha
Ap k generator ki speed thori kam ho gi Ap k generator ma jo light meter laha hota ha us pr kitny volt dhkha rha ha ?? Or ghar ma jo volt meter ha us pr kitny volt dhkhata ha meter ??
Bahi vo avr kharab tha dosra lagaya to tkh hogya but ab ik masla kr rha hai chaltay chaltay aysta hojata hai phr normal speed pay hojata hai is ka koe solution btaye
2 din me pora oil khatam ho jata hah har so din me oil dalna parta hah or oil zameen par bhi nai gir raha cheak kiya hah bus do din me oil khatam ho gata hah 15 ghantay me oil finish ho jata hah phelay me 15 din me ek bar oil dalna tha or ab 2 din me dalna parta hah plz guaide karen
Sir , mera honda ka max 500va genretor stator winding huya magar volt nehi nikal rahi hai ... Rotar armature carbon less hai . Aap kuch bataye to aacha hoga
Zia Bhai complete video making on this issue is a excellent inniciative from your. But cute brother (Straighter not Starter).
Thank full video
Zia bhai aap ki viewership to sari bahar ki hy bas aap English k sab title b sath lgana shoro karo ap k mazay ajayn gay doller ki barsaat hogi
I follow you, fron Turkey. You are wonderful.
❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤
Slt.bravo bravo Very good job monsieur technicien merci beaucoup
Sir petrol gernator ke alternator m grease hoti hai kya
Aslaam o alekum... Agr motor short ho to us ko amp meter pe chk krny ka tarika b bata dy jnb
Sir kindly make video on single coil stator winding of honda generater
Thanks for the vedio. Please tell me how to exite generater. Who is not giving out put
Zia baya 1,gontame engine coltahe or 1gontame lagatahe ap Kew ziada video banata he kew
Muchas gracias por tu video. Me sirvió de mucho.
Thank you sir.informative video
Sir . Your gratefully thanks. Please sir.
Asslamualykum Sir. Mere pass Honda ka exk 2800 janretar hai usme output splay nahi aa raha he please jankari Dena Bhai
Zia Bhai is Video me Maine Aap ka Tool kit Set Dekh liya hai or OLX pe ye hai Maine Order kar diya hai 700 Rs ka Ghar pe delivered kar denge Wo Kal
Ok wesy mery 1 video ha us ma generator k lye kon kon sy tool hony chahye ap k pass us ki video ha
Ap mere videos ma dhkh lo ap ko mil jay gi video
Zia Tv acha Main Dekhta hon
Zia bhi aar micher ka carant chek karne ka treeka to batae is ki video bhejen thanks
Ok
Zia Bhai Generator ka Rotar or AVR Kitne Tk Aajayega Andazan ????
Sir mere genretor ka ye khara Nikal nhe Raha hammer se Bhi shahyed Bering jam ho gayya ab Kiya karain oil Laga lon
hello mr.zia i have a 3.kv home generator is is starting runing but after one minutsits sound change and big noise from cylenser and stoped so please can u help me about this it was runing well sudenly happen this
Bhai mje itni english nhi ati ha
Sorry bhaye mere pass 3 kv ka generator he achee halat me he aajkal usmea kuch kharabi hugayee he ke start huneke 5 ya 7 minut ke baad band hujata he plugh bhee chang kerdiya. Shukria aapke jaldi jawab ka iska kuch hal bataean meherbani hugi. Iqbal. Karachi
Ye prbm zyada tar current coil ma hoti ha
Plug ki led jis coil sy nikal kar aarhe ha is coil ko current coil , lgntion coil b bolty hn
Ap ye coil new laga do
IN SHAA ALLAH
Ap ka generator set ho jay ga
@@ZiaTvgenerator ok bhaee meane coile change ker di ab bilkul theek chal raha he buhat shukriya zia bhayee
Sir old yamha 2.8 kva generator ka diode plate kon sa lagta hai sir
Zia bhai dynmo kitny ki mil jati ha
asalam alakum bhai kiya is denmo say ham free energy bana salty hain
Bhai thik ho Gaya hai Mobil patla ho Gaya tha molil Chang kardi our caburetor me eak adjustable scrow hota hai o scrow Tait Kar di to load 2000w Lene Laga thanks bhai aap bahut gaid di thanks
Ok & Welcome
Udaya💡💡💡💡💡💡💡💡💡💡💡💡💡💡💡💡💡💡
roter or starter kesy check karen k wo kharab he k sai he us ki video banao
G
IN SHAA ALLAH
@@ZiaTvgenerator thanks to rply me thanks bro
KHALID AHMED
ASA
Sir generator course programe mein episode no 8 ring or piston ka tariqa bataya tha aur ring aik maqsoos tareeqe dale the apne koi khas waja agar ring ke setting thori se age peche hogae to koi haraj tu nahi hai kindly reply as soon as possible. Thanks
W/salam
Rings ka gap 1 dosry sy kam sy kam 45 degree tak lazmi hona chahye
Or zyada sy zyada 90 degree
90 degree 1 gap sy 2nd gap k bilkul opposite hota ha
To opposite par set kar do
Agr setting thori bth age peche ho jay to b 45 degree sy he zyada he rhy gi
Is lye 90 degree pr set kar dena theak rhta ha
Zia bahi Mera generater start ni hora a to hus me kya masla hoga falak bi sai a aur kya masla hosakta a engin me se
Naveed Murad Welcome to my TH-cam channal
Bhai start na ho to ap plug ko thory sy petrol sy saaf kar k plug ma spark check karo agar spark theak ha to phr petrol par start kar k dhkho
Agar start ho jay to theak hn
Nhi to kick ko out kar k flywheel ko hat sy aram sy ghomao flywheel 1 hesy par jaam ho ga or baki 3 heso par free ho ga
Full free ho to tappit ki prbm ha
Agar 1 hesy pr jaam to phr theak ha
Ye check karo
Beautiful job please stater winding
Diagram showing winding also
Yes sir please show me connection & out 220 240 volt
sir honda exk 2800 genset jadha garam hotahey kay Karan padega plz sent vide
شكرا جزيلا على هاذه المعلومات الجميلة
الله يحفظكم
يامعلومه يمعود شغله كله غلط لازم يخلي بيم بنص الار ميجر ويدك على البيم مو على البولبرن يتفلش والبتاللي راح يحرك الملف وياه
سلام عليكم عندي مولدة ما تخرج بس 70v
ماهو السبب
Greetings from America, seems like a risky
Way to damage the slip rings. Why not try
Threading a slide hammer into the end and pound it off . Like a 5-10 lb one auto mechanics use , I dunno 🤷♂️
You are 👍 right
Zia bhai chakhra shat ho jaya to kis thara chak kiya jaya
Ap rotor or stater ki bat kar rahy ho ??
Rotor or stater ko check karna ho to multimeter sy check kar sakty ho
2nd series board sy check kia jata ha
Zia bhai bilkul shey khya hai ap par is par bhe video banya to bhot ashan ho jaye ge shamjna me
Nhi ab ma koi video upload nhi kr rha hn
Bs private ma kisi ko help chahye to wo bs WhatsApp pr video send kr deta hn
Bs
Wo is lye k machine k pass b log jay
Ye video b bht ha jo mane upload ki ha
Brother Mere 2.5KVA Generator Ka AVR istri ki tarrhan garam ho ke kharab ho raha 2 change kar chuka 2 din mai or voltage bhi low or unstable hain.
Winding check ki hai series pe shortage bhi nhi hai or ohm meter pe rotor ki resistance 8 se 10 ohm hai or stator ki bhi 14 se 20 ohm ke qareeb hai .
Kia waja ho sakti hai help me
Carbon b new lagao
Or jis jega carbon rotor pr touch hoty hn
In ko check karo wo theak hn
Carbon ki waja sy wo gis kar khatam to nhi ho gaya hn
Sir 2kv generator ka block toot gaya h Kia ese weld ya magic k sath Jor skty h ya ni ?
Ager governor ki jga thek he,(totne se buch gai he) to welding karwa sakte hain
Bhai shukriya... 1.kv ka genretor ka bhi banaye...
Very nice video but ak problem hota hay o ki kavi kavi engine ka oil me kerosene a jata hay a kiu hota hay eska solution kayse kore please eska Jan kari dia to bohut help hoga
Eangine and alternator assemle video mil jayegi sir
sir zia ap ne bht behtreen vedios banye he bht bht shukria. sir mera 2.7kva ka genrator he but over load hone ki waja se wo petrol pe to start hojata he but jab gas pe krte hein to bnd hojata he plase guide me
Gas kit sy gas ka presser thora zyada karna pary ga
Us k bad load pr band nhi ho ga
thank u sir, but genrator ka sound blkul beth gya he petrol p b or jab gas p krte hein to engine me dos dos hoker bnd hojata he? plase sir guide me
or han sir load dene se phele bnd hojat he
Ap full service kr lo generator ko
Carburater rokar plug filter in sb ko petrol sy dho kr dobara fit kr k new setting kr lo
IN SAHH ALLAH set ho jay ga
thank u sir
Sir isme roter aur field me kisper load Chalta hai
It is good to learn machanic.
Ishka wireing kaise hota hai wo mujhe जान ना है
Assalamwalakum bhai dinemo kye wiring kya barama batho pls
Sorry wo 1 alag kam ha
Wo hum nhi karty
Hum rewinding waly sy rotor or stater ko rewind karwaty hn
Hamara kam engine pr hota ha
Bhai dinemo ma char colour kya wire hai na who kaisa conection kara usbara ma bathoo
Shop se len Tu Kasy chak karn Avr 2.5 kv ka
Bhai Ek rotar ko khol te kholte bolt Andar rahgegya abhi Kese nikale please help
Thank"s from Chile
Thanks sir from malaysia
Sar Generator ki mukammal wairing dika de na
G ma try kar rha hn
instead of hittng the bearing with a hammer you should find a rod that will fit into the hole so if you cut a few long bolts of a slightly smaller D smaller than the original rod then feed them into the hole until they fill the space but go past the original thread now screw a bolt of the correct thread or the original behind them - they will act as a puller as the bolt pushes them on the taper sharft and the rotor will pop off.
if that sounds complex you should basically get a rod that will go in the hole and sit just behind the thread you undone - then screw a bolt in onto that rod the rod will push on the shaft and the rotor will pop off.
often they won't have threads on the end of the rotor
and it could (and has once for me) cause ther rod to get squished and stuck inside
the hammer method is believe it or not safer
anon-iraq if you make sure the rod is sufficient in diameter then you can simply cut it to the length to fit behind the original screw that goes in behind the rotor, then screw the original screw / bolt in behind it or if it has no thread another bolt of the same type there is not a chance it will ‘squish’ if you use a normal steel rod , and there is always a thread where the original rod goes at the back of the rotor, your net cost is some steel rods and maybe a bolt at different lengths as opposed to hitting the rotor with a hammer which will be jamming angular pressure onto the bearing that is supporting it.
Very nice
Bhi mere 1000 wat ki demo hai us ke chakr bto palz iş ke bare me mujy samjao
Sir stator or rotor ki winding agar msla kr rhi ho ya jal gai ho toh us ko kesy diagnose kr sktaay hain.
Buenas noches, como extraer el ventilador del inducido
Good knowledge give us thanks zia sb
Coil ke bare may bataia
Bhai iska startor winding video ni Mila
Is that cooling fan spinning backwards it would overheat the rotor on a long run wouldn't you think so
Mere pass ek petrol in generator uska jo magnet Mota hai bahut jaam chal raha hai free chalne ke liye kya aur Mota utar dene per generator Mera Sahi chal raha hai promoter is bar FIR kahate Hain to uske bad pura Jaan chal raha please sirbataiye
What brand is this generator?
Best idea
Hello, I'm very curious. Does that rotor have a permanent magnet. I am from Turkey. Do you know Turkey.
Yes it have Magnet
Asslam o alikum
Bhut acha sir
Sir isme generator ki magnet kha lagi hui he
Sir roater and starter ki coil round kitni Hoti h
Sorry bhai
Ye 1 alag kam ha
Ye kam rewinding waly karty hn
Mje is ka nhi pata
Or na he koi batata ha
Mje engine ka kam pata ha bs
Agar rewinding karwani hoti ha to wo hum dosro sy karwaty hn
Salam jamshed ap ye batayee air filter main oil a raha hai ye kyun araha hai
Filer ma oil aany ki 2 waja hoti hn
1 to tappit cover k khrab hony sy asa hota ha
2nd rings k gis jany sy gap ki waja sy air engine ma zyada jati ha or ye air out hoti tappit cover sy or is cover ma 1 paip filter cover ma aata ha isi paip sy presser ki waja sy oil b aajata ha
Avr ko kon kon se tar me jode
ap ny abhi tak video nai banai he k rooter or starter ko kesy check kia jay k wo kharab he k sahi he us ki wainding kesy check ki jay .
Bhai background music Mt lagai, aapki video wese hi achi he
Genretor mai current nhi aa raha hai to kya kare
Bhai Jan mera genrator chal raha hy lakin light pass nhi kr raha hy phly b 125 ki bettry say shock diya ta per light pass kr raha ta lakin mujhe bettry shock dy nahi ata plz ek video banao kesay shock diya jata hy
Wesy ye AVR ki kharabi ki waja sy ho rha hota ha
Apa agar shock nhi de sakty ho to is ka 1 hal ye b ha k ap governor arm ko hat sy carburetor karo to is sy speed tez hoti ha
Bth bar asa hota ha k speed ki jhatkay sy light aajati ha
Rad dal k kaise Nikal sakte hai
english vid would be great!
No te entiendo nada, pero muy bueno el video
Bhi, plz ak video... AVR , Stator , Rotor and diode box ka apas ma connection/wireing ki b dalayn
Very nice vedio
Sir 7.6kva ka genretoe hai Bina load PE sahi se chalta hai load dete hi engine band ho jata hai Kya fult honga sir
Ye valve ki prbm hoti ha
Mtlb ap ko head open kar k valve ko theak sy saaf kr k lagao
Agar valve ma zyada prbm ha to ap ko new valve lag wany pary gy
Valve ma seat or duide hoti hn
Ye lath machine wala set kr k de ga
Ap ye kam karwa lo
Mje whatsapp pr generator ki mobsy choti c video bana kr send karo ma dhkhta hn
+92 312 3902109
Is num pr bhje dena video
Us k bad dhkhty hn valve ki prbm ha ya nhi
Great job 👍👍👍
Excelente información desde como trabar el estator y dos formas de quitarlo muchas gracias seguí adelante
Sar hamare pash 3 kgw alti single phesh ka hi aior ham use duvl phesh banana chhahte hi uashko banane ke leye btaiyel
very informative. thanks
Bhai avr Chang Mardi phir bhi 1500w ka load dene par generator off ho jata hai 2kw ka generator full load kitna lega batai
Zia Bhai Rotor ka fan nikalny or lagany ki video upload kryn...Thanks.
ok
Muy bueno profe
buy starter or Rotor new mail Jatt hi danbo mokmml ki price ky he jawab Jarur Dena comment me
G bhai generator ki har 1 chez mil jati ha market sy new
Or 2nd hand b mil jati ha
Rewinding karny wali shop pr rotor or stater 2nd hand aram sy mil jaty hn
Or ap usi shop pr apna old rotor or stater seal b kar sakty ho
Ap ko shop waly sy bat karni pary gi har koi alag alag rate lagata ha
Agar ap new rotor or stater lena ch rhy ho wo b mil jata 2.5 ka 8000 sy 9000 tak ma mil jata ha
5 kv generatar Ka rotar winding ky Kia charges ho gy?
Bahy mera genrator ka avr kharab hoa to wu change kya hai but light blimb krty hai avr bhy tkh hai ? Kya problm hai plz guide me
Ap k generator ki speed thori kam ho gi
Ap k generator ma jo light meter laha hota ha us pr kitny volt dhkha rha ha ??
Or ghar ma jo volt meter ha us pr kitny volt dhkhata ha meter ??
Bahi vo avr kharab tha dosra lagaya to tkh hogya but ab ik masla kr rha hai chaltay chaltay aysta hojata hai phr normal speed pay hojata hai is ka koe solution btaye
Bhai sahab apny iska.ivr or bush Kagan ghayeb kiyeh hain
Generator kitne RPM par work karta hai?
Thanks jan
2 din me pora oil khatam ho jata hah har so din me oil dalna parta hah or oil zameen par bhi nai gir raha cheak kiya hah bus do din me oil khatam ho gata hah 15 ghantay me oil finish ho jata hah phelay me 15 din me ek bar oil dalna tha or ab 2 din me dalna parta hah plz guaide karen
Does the generator have a fixed magnet, if so, where is it?
Good job brother
Sir , mera honda ka max 500va genretor stator winding huya magar volt nehi nikal rahi hai ... Rotar armature carbon less hai . Aap kuch bataye to aacha hoga
Light kese banti hai .
Jabki isme megnet to nhi dikha de rha hai .
Is that synch genarator ...?
Motor kaise check karen
شكر ا thank you allah bless U
भाई साहब आप जिसे स्टारटर कहते हो उसे स्टेटर कहते है |