Cylencer or head in dono k beach ma packing lagti ha Is ko packing gas kit b bolty hn Ap check karo ye packing jal kar end to nhi ho gai ha Agar asa ha to ap markit sy new cylencer ki paking la kar theak fix kar do
Bhai Mera generator 3 kv loncin hay, us ka much dino say problem Kar Raha hay. Starting Kay aik do minute Tak dhuwan deta hay phir theek ho jata hay. Load sahib uthata hay. Gas pay hay, oil badli karwa tha, total ka 20_50 Wala. Mehrbani Kar Kay brain Kya masla hay.
Zia bhai mere paas fireman ka 3kv ka generator hai uss ko chalty huwy taqreeban 2 hafty k liye bnd kr k rkha tha phir 3 se 4 din pehly us ki saaf safai kr k start krny ki koshish ki to shaft jis pr flywheel lga huwa hota hai 1 turn le kr jam ho rha hai beshak usko forward ghuma lo ya reverse ghuma lo... please iss k baary me bta dijiyay k kia msla ho skta hai.... aur iss ka hal kia hai ..?
W/salam Ye prbm carburator ma he ha Carburator ma sy petrol theak sy pass nhi ho rha ho ga Ap koi or carburator laga kar check karo Agar ap ko petrol pr zyada use karna ha to phr ap new carburator laga lo to best ha
sir mere pass 800 watts ka jd1501 wala generator he us ki rings kharab hen main ne sara generator khol liya he ab us ko assemble karna he plz bata den ko tappet ki setting k liye kon sy number ki feeler gauge use karni he.aur ye kese findout krte hein k kon c gauge no use ho gi. - via YTPak(.com)
outdoorpowerinfo.com/engine_specs/honda_valve_gaps.asp Ye 1 website ha is pr ap ko bht sy engines ka pata chal jay ga k kis engine ma valve ki setting kia honi chahye
Salam zia bhai, 1)AVR ko baghair genrater kesay check kia jaskta hay, 2)gernrater jab start hota hay to batteri terminl par short mehsos hota hay,is ka hal bataye plz
Aaj meain Honda 3 kV ka engine banaon gaa. Ye meri field naheen hay magar aap ka program daikh ker shoq ho gaya hay.mearay pass 2 generator heain.one is out of order.us per experiment karon gaa. I am a doctor .
Agar ap frame sy nikal kar generator kholo gay to b aram sy khol jay ga Par frame sy out karna thora mushkil ho ga Frame ma jitna b ho sakay generator khol lo Engine ap frame sy nikal kar khol lo Pr is k lye ap ko helper ki zarorat pary gi
Rings gap ap aamny samny rhkha karo Wesy ye 90 degree pr banta ha Piston ring ka gap kam sy kam 45 degree pr lazmi hona chahye Ap agar 90 degree pr set karo gy to agar wo apne gega sy helta b ha tab b wo 45 sy oper he ho ga Agar gap 1 sth ho jay tab b generator chaly ga Pr is sy oil jaldi black ho ga Or kuch hat tak oil kam ho ga Mtlb engine ma oil thora thora jal kr kam hony lg jay ga
zia mai ne first time gernetor ap k tutorial dekh k banaya hy sab final hu gaya hy but ap k tutorial no 17 jis mai ap ne governor ki adjustment bataye hy wo mai kafi try k bad bhi samajh nhi pa rha sab final hy but governor ki setting ki waja se on nhi hu pa raha plz plz jald apna whats up send kren i will call to u
Sir mera genrater 1 ganty bad band ho jata hy Bad me start nahi hota naya palag lagata hon phir start ho jata he 3 ya 4 bar masla aa chuka hy Kay problem ho sakti he
Sir genrator chal rha h mgr chalty chalty thori dair bd current dena bnd kr deta h genrater on rheta h mgr light nh ati . Us ka capiseter bhe change kr k deckha h mgr koi faida nh hoa . Plz guide kr dn
Yar ye capacitor waly generator mje samjh nhi aaty hn Is k hal ap ko motor winding wala he bata sakta ha jo generator ki motor banata ho Q k engine ka kam 1 alag kam ha or winding light ka kam alag ha
mera generator jaam hogya hy, chalty chalty band hogya or phr start nhi horaha bilkol jaam hogya hy, iska kya matlb hy?? kesy check kroon or kesy repair karoon iski video banaden as sson as possible
Assalam u alkium, Zia bhai, Generator petrol pe start ho raha hy,lken gas pe nhy ho raha .phly gas pe self start ho jata tha lekn ab nhy ho raha. Please reply .
Asslamualkium, Zia bhai.es k baad bhe nhy chla generator.es ke tank mein rust a gaya hy.pta nhy ka say?self start bhe nhy ho raha.battery bhe check hy.us ko bhe charge kerwa k check keya.
main 2.5 kv ka gernetor bana k final ker chuka hu but governer arm jo lsat ap k 17 tutorial mai tha wo samajh nhi paya plz apna no den mjy ap ki guide line ki sakht need hy
Bhai apne complete generator bnaya hai.kindly Ye b bta do k kon kon sa saman le kr start krna chaye Jese carburetor ki packing etc.tk bar bar Shop k leye na jana ho
Generator jb b kholta ha to full packing lazmi leni parti ha Full packing ma hr chez ki gas kit hoti ha Extra 1 engine tube hoti ha jo alag dy leni parti ha Baki jo kam karwana hota ha wo to ap ko pata ho ga k kia kam karwana ha generator ma to wo he lena parya ha Mere next video ma in ki details hn wo upload ho jay us k bad b chotay chotay jo b generator ma kam hoty hn un ki video upload karo ga Is k ilwa mera num ha kuch pochna ho to rabta kr sakty ho
Zia Bhai Aap Ki Video Dekhne Bad Mein Ne Apna Jarnetar Kholne Ka Irada To Kar Leya Or Agr Kuch Samj Na Aya To Kahin Asa Na Ho App Ko Call Karta Rahon Or App Revce Hi Na Karin Reply Me
Ap oil new jb b dalo to usi time plug filter saaf kar deya karo or bolt etc 1 br check kar leya karo to bs ye he tuning ha Baki agar kisi chez ba prbm feel ho tub ap us ko not karo k kia prbm ha or us prbm ko dor kar do Tuning to bs asy he pesy nikalny ka method ha or kuch nhi ha
ap 2 sy 4 bar governor arm ko carbureter ki taraf karo is sy speed zyada ho gai to light aajay gi mtlb 1 chatka do speed ka is sy volt zyada bany gy or light aajay gi
Asad Afridi Welcome to my TH-cam channel Bhai blast tappit ki setting out hony sy hota ha ya plug k short hony sy hota ha Ap silencer side par jo tappit ha us ki setting dobara karo agar is sy b set nhi ho rha ha to phr ap new plug laga do start na hona plug ki waja sy b ho skata ha short plug ma asy he hota ha
Muhammad Rameez Welcome to my TH-cam channal AVR new ha phr b volt kam ho gay to is ma main prbm rotor mabho gi ya phr rotor pr jo camotaters lag hua hota ha jis pr carbon touch hoty hn ye gis kar kharab ho gaya ho ga Is ki waja sy AVR b khrab hota ha or carbon b Ap check karo agar camotater khrab ha to new lagwao
Kick starter ki waja sy b jaam ho jati ha Agar starter ki dori theak sy out na ho rhe ho Ya bht zyada tight ho jay Next jaam hona hota ha valve ki setting out ho is sy b kick jaam feel hoti ha To is k lye valve ki setting karni parti ha Last ma kick ka back marna Agar engine back mary to wo camshaft k khrab hony ki nishani hoti ha
@@ZiaTvgenerator asalamo alaikum Zia b hum ne genetor banwaya h lekin Genetor banay k baad abhi tak awaz aik jaga nhi ROK rahi h abhi tak genetor mistari be hume dia nhi hai na petrol par aik jaga ROK raha h na gas par rok raha h plz koj hall bata dain .mne apki video se bht kuch sikha hai plz plz help me...
Bhai mera generator 2.7kva ka ha or wo pehly petrol pe start hota ha phr gas pe convert krna parta ha direct gas pe nhi start hota ha is ka koi solution ???
Gas pr start karny k lye ap ko gas kit ki setting karni pary gi Setting k lye kit pr out wali line pr 1 bolt hota ha or is bolt pr 1 nut hota ha Nut ko lose kar k bolt sy setting karni parti ha Setting k lye engine ko start kar k he bethani parti ha Kon kis jega set hota ha koi kisi or jega Is lye is ki koi 1 setting nhi hoti ha Is ma andaza kar k or engine k sound sy he pata chalta ha k kis jega gas set ha engine k lye
Ap capacitor pr dhkho num likha hua ho ga Jo num likha hua ha isi num ka ap new capacitor le kr laga do Ya ap capacitor ko shop pr le jao shop wala us ka num dhkh kr new de dega
Dohwa engine tab deta ha jb rings gis kar choti ho jay Or engine oil ring sy pass ho kr piston ko oper aany lag jay Piston k oper aag hoti ha jis sy oil burn hota ha or dohwa ban jata ha Is ko theak karny k lye ap ko engine full open kar k new clynder bore new ring piston or new rings dalni pary gi Mtlb k ap ko engine full general karna pary ga Agar ap ye kam kar sakty ho to phr ap 2.5 kv ka engine 3500 sy 4000 tak ma full general kar sakty ho Agar shop sy karwao gy to 7000 sy 8000 tak le gy shop waly Or shop walo ka koi pata b nhi ha k kia dal rhy hn kia nhi
Petrol per 5 minutes generator chal raha hai or silincer Mai sai fire ho Raha hai or phir generator band ho jataa hai ye kiya waja ho sekti hai ager 5 minutes per band b nai hota to silincer Mai sai fire hora hotha hai
Awaz kam karny k lye dhkhna parta ha silencer ko Engine ki speed ko Tappit ki setting theak ho Normal load ho Main silencer hota ha silencer 1 moti chadar wala milta ha is sy awaz ma fark parta ha Phr speed agar had sy zyada ha to phr b awaz zyada hoti ha Normal pr set rhta ha Tappit ki setting agar theak ho to awaz ma bth fark parta ha Last ma oil ka hota ha Oil full ho to b awaz m kami rhti ha
Ye full 1 sy le kar 17 parts hn is video k Ap mere channal pr pr jao Mera nam jo Zia tv ha is pr ok kar k channal ma jao Or videos ma jao to sab video mil jay gi
Is sab Kam sikhany Ka apko Allah pak ajar ata frmain kitny logon ki apne madad ki
Good vedio. Very deeply & nicely breaf.
Me ne BHI ap ko dekh ker apna generator Sahi kia.allah ap ko traqqi ata fermae (ameen)
Very nice zia Bhai. You are a great man. Ye chezain jaldi Koi mechanic nhi btata. God bless you
Those of us that don't understand Hindi are in dying need of the English subtitle , pls can anyone make it available.
Masha Allah
وعليكم السلام ورحمة الله وبركاته وفقكم الله وستركم من كل شر
Very nice vedio. Well demonstrated.
Boht aala
You are doing a great job.
sir MASHA ALLAH ap ne video mein bhot hi achhe andaz se samjhaya he. har har cheez waazeh pata chalti he. thanks
- via YTPak(.com)
Thanks brother
Bhai mujhe btye ki birla yamaha 2800 genrator me kitna oil padta h aur kitne hr me change krna hota hai
Great Yr Good Work
Me Full Course Sekna Hy
AOA
Your videos very good and loncin gernator 2.5kv bhut awaz kar raha ha ge se cylencer phata howa ho kia problem ha
Cylencer or head in dono k beach ma packing lagti ha
Is ko packing gas kit b bolty hn
Ap check karo ye packing jal kar end to nhi ho gai ha
Agar asa ha to ap markit sy new cylencer ki paking la kar theak fix kar do
KHUDA KHUSH rakhe Aap ko
shukrya bhai
Good
Bhai Mera generator 3 kv loncin hay, us ka much dino say problem Kar Raha hay. Starting Kay aik do minute Tak dhuwan deta hay phir theek ho jata hay. Load sahib uthata hay. Gas pay hay, oil badli karwa tha, total ka 20_50 Wala. Mehrbani Kar Kay brain Kya masla hay.
Bhai g zara is tool k baray me batao k ye kitny ka h jis sy ap generator khol or band kar rahy h
Kio bahi Bata sakta hai kia motor cycle aur generator enjin same hotaa hai kia
Zia bhai mere paas fireman ka 3kv ka generator hai uss ko chalty huwy taqreeban 2 hafty k liye bnd kr k rkha tha phir 3 se 4 din pehly us ki saaf safai kr k start krny ki koshish ki to shaft jis pr flywheel lga huwa hota hai 1 turn le kr jam ho rha hai beshak usko forward ghuma lo ya reverse ghuma lo...
please iss k baary me bta dijiyay k kia msla ho skta hai.... aur iss ka hal kia hai ..?
Ap mje whatsapp num pr generator ki choti c video send karo
Ma dhkhny k bad he bata sakta hn k kia prbm ho gi
+92 312 3902109
Is pr pr bhejo video
Thanks brother 😊
spark plugin se knowning ka sound arha ha kiya issue ho sakta ha ???????????
Bohat zabardast
Dear ZIA.
❤❤❤❤❤
thanks for video iam in kurdistan
Jegr Hajiawa Welcome to my TH-cam channal
Salam zia bhai.
3 kva genratr petrol par 10 secnd bad band hota hay or gass par chalt hay,carborater ke safae ke hay,tank b saaf kia hay,
Plz help me
W/salam
Ye prbm carburator ma he ha
Carburator ma sy petrol theak sy pass nhi ho rha ho ga
Ap koi or carburator laga kar check karo
Agar ap ko petrol pr zyada use karna ha to phr ap new carburator laga lo to best ha
Zia bhai 1 bat puchni thi.....
Jo betrry charging coil hoti ha us ki positive wire ka kis k sath conection krna hota ha
Keep it up.
Can we get a English version of the course.
Very nice brother
Please do you have this course in English language. I really love your teaching. I want follow up but I can't hear Hindi language
sir mere pass 800 watts ka jd1501 wala generator he us ki rings kharab hen main ne sara generator khol liya he ab us ko assemble karna he plz bata den ko tappet ki setting k liye kon sy number ki feeler gauge use karni he.aur ye kese findout krte hein k kon c gauge no use ho gi.
- via YTPak(.com)
outdoorpowerinfo.com/engine_specs/honda_valve_gaps.asp
Ye 1 website ha is pr ap ko bht sy engines ka pata chal jay ga k kis engine ma valve ki setting kia honi chahye
Salam zia bhai,
1)AVR ko baghair genrater kesay check kia jaskta hay,
2)gernrater jab start hota hay to batteri terminl par short mehsos hota hay,is ka hal bataye plz
واعلیکم اسلام ۔ 1۔جنریٹر کے Avr کو بغیر جنریٹر کے پروڈکٹ طریقے سے چیک نہیں کیا جا سکتا،
2۔
Terminal ko khol ker saf ker ke tit kr ke lagaen .or us per gres lgaen
@@muhammadtahir818 ok thanx
Very good video sir please part 2vidio
Brother mje aik help chahiye k Mera generator slow chal rha he or avr pr voltage show nai kr RHA to problem avr ka he ya roster ka?
Agar engine ki speed kam ha to volt show nhi ho gy
Ap speed sy normal karo
Agar us k bad b volt nhi aarhy hn to phr AVR ne prbm ho sakti ha
Aaj meain Honda 3 kV ka engine banaon gaa.
Ye meri field naheen hay magar aap ka program daikh ker shoq ho gaya hay.mearay pass 2 generator heain.one is out of order.us per experiment karon gaa.
I am a doctor .
Zia bhai gernater me betrey install karny ki vedios bhi bnaye kabhi
IN SHAA ALLAH
agar ham gernetor fram se bahar nikaal ker kholeain tu aasaan haoye gaa kya?please expalin.
Agar ap frame sy nikal kar generator kholo gay to b aram sy khol jay ga
Par frame sy out karna thora mushkil ho ga
Frame ma jitna b ho sakay generator khol lo
Engine ap frame sy nikal kar khol lo
Pr is k lye ap ko helper ki zarorat pary gi
thanks.agar ring ka gap lagatay waqt agay pechay ho jay ya out ho jaye tu kya ho gaa
Rings gap ap aamny samny rhkha karo
Wesy ye 90 degree pr banta ha
Piston ring ka gap kam sy kam 45 degree pr lazmi hona chahye
Ap agar 90 degree pr set karo gy to agar wo apne gega sy helta b ha tab b wo 45 sy oper he ho ga
Agar gap 1 sth ho jay tab b generator chaly ga
Pr is sy oil jaldi black ho ga
Or kuch hat tak oil kam ho ga
Mtlb engine ma oil thora thora jal kr kam hony lg jay ga
Zia Tv .thanks .bhai.
zia mai ne first time gernetor ap k tutorial dekh k banaya hy sab final hu gaya hy but ap k tutorial no 17 jis mai ap ne governor ki adjustment bataye hy wo mai kafi try k bad bhi samajh nhi pa rha sab final hy but governor ki setting ki waja se on nhi hu pa raha plz plz jald apna whats up send kren i will call to u
Bike ke engine se 2.5 kv ka ganator chala sakte h kya sir
Nhi bike ka engine 70cc hota ha
Generator ka engine 170cc hota ha
Bike k engine sy itna power nhi mil sakta ha
Sir mera genrater 1 ganty bad band ho jata hy Bad me start nahi hota naya palag lagata hon phir start ho jata he 3 ya 4 bar masla aa chuka hy Kay problem ho sakti he
Ap plug k sth lgntion coil
Jo flywheel k pass lagi hui hoti ha ye coil or plug new laga do
IN SHH ALLAH
set ho jay ga
Nice
Zia bhai kia 1.5 kv jenerator engine open karne ka tareeqa bhi isi tarah hai?
G g isi trhan he ha
Bs size ma chota ha
Sir genrator chal rha h mgr chalty chalty thori dair bd current dena bnd kr deta h genrater on rheta h mgr light nh ati . Us ka capiseter bhe change kr k deckha h mgr koi faida nh hoa . Plz guide kr dn
Yar ye capacitor waly generator mje samjh nhi aaty hn
Is k hal ap ko motor winding wala he bata sakta ha jo generator ki motor banata ho
Q k engine ka kam 1 alag kam ha or winding light ka kam alag ha
bhai agr generator missing kary to us ma kya falut hota ha plz reply
Missing ki prbm plug ka short hona
Petrol ka theak sy na miln
Ya phr lgntion coil ka dim hona
In ma he prbm hoti ha
mera generator jaam hogya hy, chalty chalty band hogya or phr start nhi horaha bilkol jaam hogya hy, iska kya matlb hy?? kesy check kroon or kesy repair karoon iski video banaden
as sson as possible
Spark plug bhi new laga liya ha phr bhi wohi problem ha
Thankyou
asalam o alaikum zia bhai patrol avrege kum ziyada k bare mai bataye
I miss you
Assalam u alkium,
Zia bhai,
Generator petrol pe start ho raha hy,lken gas pe nhy ho raha .phly gas pe self start ho jata tha lekn ab nhy ho raha.
Please reply .
Plug ko theak sy saaf kr k lagao
Or gas kit ka presser to theak ha ??
Agar gas kit ma koi prblm hui to asa hota ha
Asslamualkium,
Zia bhai.es k baad bhe nhy chla generator.es ke tank mein rust a gaya hy.pta nhy ka say?self start bhe nhy ho raha.battery bhe check hy.us ko bhe charge kerwa k check keya.
1 baar self start ho tha ,wo bhe bus 1 round he chla hoga pher band hogya.
Kindly reply.
main 2.5 kv ka gernetor bana k final ker chuka hu but governer arm jo lsat ap k 17 tutorial mai tha wo samajh nhi paya plz apna no den mjy ap ki guide line ki sakht need hy
Sir, e generator kea kerosene se chalega??
بسم اللہ الرحمن الرحیم، السلام علیکم ۔جناب یہ دونوں قسم کے فیول پٹرول اور گیس پر چل سکتا ہے
bhai mera ganrator start to hojata hay par bas 2 mint chalta hay phir khud hi band ho jata hay kia masla ho sakta hay
Bhai apne complete generator bnaya hai.kindly Ye b bta do k kon kon sa saman le kr start krna chaye
Jese carburetor ki packing etc.tk bar bar Shop k leye na jana ho
Generator jb b kholta ha to full packing lazmi leni parti ha
Full packing ma hr chez ki gas kit hoti ha
Extra 1 engine tube hoti ha jo alag dy leni parti ha
Baki jo kam karwana hota ha wo to ap ko pata ho ga k kia kam karwana ha generator ma to wo he lena parya ha
Mere next video ma in ki details hn wo upload ho jay us k bad b chotay chotay jo b generator ma kam hoty hn un ki video upload karo ga
Is k ilwa mera num ha kuch pochna ho to rabta kr sakty ho
As salam alikom
Koi bhai mujhy batayga ye generators ka diploma kahan hota hy chooty or heavy generators dono karachi main
Pleas help me
Zia Bhai
Aap Ki Video Dekhne Bad Mein Ne Apna Jarnetar Kholne Ka Irada To Kar Leya
Or Agr Kuch Samj Na Aya To Kahin Asa Na Ho App Ko Call Karta Rahon Or App Revce Hi Na Karin
Reply Me
Salam Bhai Jan generator Mai gas ki setting samjha dijiye aur noise na kare....
Ok
zia bhai mera generator start bilkul thk leta hai lekin 5 mint bd jhatky le k bnd hjata hai kia karun plz reply
Ap lgntion coil new laga lo
IN SAHH ALLAH
set ho jay ga
Bhai Mera generator 130 ghantay chal choka Hy iski tuning kb karai Jaye plz Bata do gas PR chalta hy
Ap oil new jb b dalo to usi time plug filter saaf kar deya karo or bolt etc 1 br check kar leya karo to bs ye he tuning ha
Baki agar kisi chez ba prbm feel ho tub ap us ko not karo k kia prbm ha or us prbm ko dor kar do
Tuning to bs asy he pesy nikalny ka method ha or kuch nhi ha
@@ZiaTvgenerator thanks brother
sir kissi bhi generator ke tappet setting k liye feeler gauge number kese mahloom karen ge.k iss k liye kon sa gauge no use ho ga
- via YTPak(.com)
Bhai generator kay model no. sath Google pe search karlen in Sha Allah mil jaega
Generator chal raha hai current nh de raha AVR or carbon b change kr lia hai. Ab kia problem ho sakti hai.
ap 2 sy 4 bar governor arm ko carbureter ki taraf karo
is sy speed zyada ho gai
to light aajay gi
mtlb 1 chatka do speed ka is sy volt zyada bany gy or light aajay gi
mera generator chal raha h mgar current nae araha tw avr ka masla hai ya carbon
AVR ma zyada tar prblm hoti ha
Carbon ma b ho sakti ha pr wo bth kam hoti ha
Ap AVR new laga lo set ho jay ga
Generator engine oil ziyada consume krrha ha kiya reason ha ?? Smoke thek ha bilkul
Is ki main prbm rings ka khtam hona ha
Or is ka hal full engine open kar k new rings dal kar phr band karna pary ga
Or koi hal nhi ha
@@ZiaTvgenerator Kiya generator ko dhope me chalanay se kuch hoga ?
@@ZiaTvgenerator kesy hogi video link ?
I strongly wish you can translate it to English for we that don't understand hindi
Honda gk2000 ke sath power on dynemo ki repeating me video banae sir
Zia bahi tapads b thek kar diea hain ab b start nahi ho raha gas and petrol pa b bus doug doug karta hai kbi kbi blast ke awaz b ati hai plz guide sir
Asad Afridi Welcome to my TH-cam channel
Bhai blast tappit ki setting out hony sy hota ha ya plug k short hony sy hota ha
Ap silencer side par jo tappit ha us ki setting dobara karo
agar is sy b set nhi ho rha ha to phr ap new plug laga do
start na hona plug ki waja sy b ho skata ha
short plug ma asy he hota ha
Thanks bahi plug b change keya hai ab koi samaj nahi ah rahi
Bhai chalte chalte voltage kam ho gaye 150 pe agaya kiya masla hai avr bhi new dala hai
Muhammad Rameez Welcome to my TH-cam channal
AVR new ha phr b volt kam ho gay to is ma main prbm rotor mabho gi ya phr rotor pr jo camotaters lag hua hota ha jis pr carbon touch hoty hn ye gis kar kharab ho gaya ho ga
Is ki waja sy AVR b khrab hota ha or carbon b
Ap check karo agar camotater khrab ha to new lagwao
@@ZiaTvgenerator bro chek kiya tha carbn change kiye hain
Sallam mera generator shor kar ra ha koi solutn batay plz
Bhai mera generator oil nhi khata h fir b plug short ho jata hai aysa Q
Is ma ye prbm ho sakti ha k ap k engine ki lgntion coil khrab ho jo zyada power de rhe ho gi plug ko
Ganerator stat hojata ha 15 mant chalta ha or banhojata ha ?
Ye prblm zyada tar lgntion coil ki hoti ha
Coil dim par jati ha is lye asa hota ha
Ap new lgntion coil laga lo
IN SHAA ALLAH
Set ho jay ga
Agar engine ki kick jaam ho jay tu kya kerna hoga.
Kick starter ki waja sy b jaam ho jati ha
Agar starter ki dori theak sy out na ho rhe ho
Ya bht zyada tight ho jay
Next jaam hona hota ha valve ki setting out ho is sy b kick jaam feel hoti ha
To is k lye valve ki setting karni parti ha
Last ma kick ka back marna
Agar engine back mary to wo camshaft k khrab hony ki nishani hoti ha
@@ZiaTvgenerator asalamo alaikum Zia b hum ne genetor banwaya h lekin Genetor banay k baad abhi tak awaz aik jaga nhi ROK rahi h abhi tak genetor mistari be hume dia nhi hai na petrol par aik jaga ROK raha h na gas par rok raha h plz koj hall bata dain .mne apki video se bht kuch sikha hai plz plz help me...
Bhai mera generator 2.7kva ka ha or wo pehly petrol pe start hota ha phr gas pe convert krna parta ha direct gas pe nhi start hota ha is ka koi solution ???
Gas pr start karny k lye ap ko gas kit ki setting karni pary gi
Setting k lye kit pr out wali line pr 1 bolt hota ha or is bolt pr 1 nut hota ha
Nut ko lose kar k bolt sy setting karni parti ha
Setting k lye engine ko start kar k he bethani parti ha
Kon kis jega set hota ha koi kisi or jega
Is lye is ki koi 1 setting nhi hoti ha
Is ma andaza kar k or engine k sound sy he pata chalta ha k kis jega gas set ha engine k lye
zia bhai shukaria
ap mujay apna number de saktay han ?
generator thek chalta ha start honay k bad lakin petrol pe start hota ha tou mujay start kr k phr gas ki setting krni hogi ??
Whatsapp num
+92 312 3902109
Sir ji hamare generator ka capacitor kharab ho gaya hai 1.2 kv kaun se number ka capacitor chalega please reply
Ap capacitor pr dhkho num likha hua ho ga
Jo num likha hua ha isi num ka ap new capacitor le kr laga do
Ya ap capacitor ko shop pr le jao shop wala us ka num dhkh kr new de dega
Old capacitor par naam nahi hai bhai sahab
Ok ap old wala shop pr le jao
Shop wala dhkh kr size sy pehchan jay ga
Ganator engine kitane hp ka h 2.5 kv le liye
2.5 kv k generator ma 4.5 hp ka engine hota ha
Sir generator start nahi hu raha h s ki kia waja h
nice bro
bhai jaan panel connection ka bataen mujhe volte meter ki tarain lagani hai woh kaam nahi kar raha
hi bro ...how can i get it in English?
Assalam'OAluikum,
Next vedio kab aye gi
Bhai mera generator bhot dohwa Mar raha hai tu pleas ap bataden ke kia karo
Dohwa engine tab deta ha jb rings gis kar choti ho jay
Or engine oil ring sy pass ho kr piston ko oper aany lag jay
Piston k oper aag hoti ha jis sy oil burn hota ha or dohwa ban jata ha
Is ko theak karny k lye ap ko engine full open kar k new clynder bore new ring piston or new rings dalni pary gi
Mtlb k ap ko engine full general karna pary ga
Agar ap ye kam kar sakty ho to phr ap 2.5 kv ka engine 3500 sy 4000 tak ma full general kar sakty ho
Agar shop sy karwao gy to 7000 sy 8000 tak le gy shop waly
Or shop walo ka koi pata b nhi ha k kia dal rhy hn kia nhi
Bhai field ke connection kesa honge
Field ka kon sa connection ??
Assalam o Aliakum
Petrol per 5 minutes generator chal raha hai or silincer Mai sai fire ho Raha hai or phir generator band ho jataa hai ye kiya waja ho sekti hai ager 5 minutes per band b nai hota to silincer Mai sai fire hora hotha hai
Exhuse valve k lose hony ki waja sy asa hota ha k fire marta ha
Ap valve ki setting karo
Thora sa tight kr lo valve
Set ho jay ga
Zia Tv thanks for reply
sir your num
Head Out Kar Ke Valve Ki Setting karay ya Rocker koo tight karay.
Bhai Jan with due respect! Kindly tashih kar len. AAP Pori vedio Mai bar bar starter Bol rahy Hai jab us ka Nam straighter Hai.
Bhaii suN sound ka silanCer bataoO
Start nai horaha hai Generator 2.2 kva ka hai fire mar raha hai spark plugs new bi change Kia hai tab bi wohi masla hai
Contact 03122797984
Bhai generator ka awaz kesi kam kary
Awaz kam karny k lye dhkhna parta ha
silencer ko
Engine ki speed ko
Tappit ki setting theak ho
Normal load ho
Main silencer hota ha
silencer 1 moti chadar wala milta ha is sy awaz ma fark parta ha
Phr speed agar had sy zyada ha to phr b awaz zyada hoti ha
Normal pr set rhta ha
Tappit ki setting agar theak ho to awaz ma bth fark parta ha
Last ma oil ka hota ha
Oil full ho to b awaz m kami rhti ha
men don't mind but you are fucking awsome i think you are sindhi
2.5 kv ka generator ka salap kese nkle ga explain plz
Kik wala firnt cover khol ker fulai wheel khol lain . Self ke 2 bolts apko nazer jaengy.
Plug 2-3hr me he short ho jata hai aur kala bhi ho jata h
Next part kaha hai iska
Ye full 1 sy le kar 17 parts hn is video k
Ap mere channal pr pr jao
Mera nam jo Zia tv ha is pr ok kar k channal ma jao
Or videos ma jao to sab video mil jay gi
Aap sy contact kesy Karen???
Only WhatsApp num
+92 312 3902109
Generator power 300 nekalta hy us pr koi video bna den
Kuch time lg jay ga
Ap AVR new laga lo
Video ma time lg jay ga
Zia bhai mera generator load nhi uthata is k lye kia krna pryga?
Mobil me tel kyu miljata h iski kya wjah h
Asslam o alaikum!
Zia bhai ap ka what'sapp. nmber kia ha.?
3 KV generator ki tuning ka tarika bta den plz. Shukriya
+92 312 3902109
Background music shouldn't be used and voice need more clear
Jaany De yr bilkul thek bni he. Kery mt nikalo