Polyacrylamide Gel Electrophoresis- PAGE - Amrita University

แชร์
ฝัง
  • เผยแพร่เมื่อ 5 ต.ค. 2024
  • ▶ This video channel is developed by Amrita University's CREATE
    www.amrita.edu/...
    ▶ Subscribe @
    / amritacreate
    / amritavlab
    ▶ Like us @
    / createatamrita
    ▶ For more Information @
    vlab.amrita.edu...
    ▶ Amrita Virtual Lab Project website
    vlab.amrita.edu
    PAGE (Polyacrylamide Gel Electrophoresis), is the most widely used analytical method to resolve separate components of a protein mixture based on size.
    For this protein molecules of different shapes and sizes, need to be denatured. This is done with the aid of SDS, so that the proteins no longer have any secondary, tertiary or quaternary structure. The proteins covered by SDS are negatively charged. When loaded onto a gel matrix and placed in an electric field, the proteins will migrate towards the anode (positively charged electrode). They are then separated by a molecular sieving effect based on size. After visualization by a protein-specific staining technique, the size of a protein can be estimated by comparison of its migration distance with that of a known molecular weight marker.

ความคิดเห็น • 15

  • @majeedaraza81
    @majeedaraza81 7 ปีที่แล้ว +19

    stop using music behind

  • @akand999
    @akand999 13 ปีที่แล้ว +3

    For Stacking gel, its Tris of pH 6.8, urs is wrong... check it again

  • @TheChC47
    @TheChC47 13 ปีที่แล้ว +2

    @ktochi297 i'm not 100% sure, but i think that the advantage of Tris is that it's isotonic and its pH is close to the physiological pH (7). So, it makes sense a Tris pH 6.8 for the stacking instead of 8.8. But i'm just wondering :P

  • @safeyyasofy5515
    @safeyyasofy5515 9 ปีที่แล้ว +1

    very good explained !! well done :)

  • @RyanRamanayake
    @RyanRamanayake 12 ปีที่แล้ว +3

    The accent needs to be a bit more clear, all info is right and presented very well :)

  • @ktochi297
    @ktochi297 13 ปีที่แล้ว

    @akand999 I think the pH of the stacking and resolving gels would depend on what your protein sample is.

  • @fitriamfauzi2586
    @fitriamfauzi2586 7 ปีที่แล้ว

    how is the connection between sds chamber and power suply is not correct? what is the effect with the sample or the gel?

  • @LFS2333
    @LFS2333 10 ปีที่แล้ว +1

    very nice

  • @kbnsahebmaski8857
    @kbnsahebmaski8857 10 ปีที่แล้ว

    tnx its helpful to meeee

  • @Drshinemadathil
    @Drshinemadathil 12 ปีที่แล้ว

    thank u.......

  • @MsRicha01
    @MsRicha01 8 ปีที่แล้ว

    I AM PLANNING TO PURCHASE THIS SYSTEM. CAN PEOPLE WHO USED THIS LET ME KNOW IF THIS IS GOOD OR NOT. WE ARE CURRENTLY USING HOEFFER SE260. GOOD SYSTEM BUT GEL CASTING IS BIT DIFFICULT. I HAD HEARD SOMEWHERE THAT BIORAD GEL CASTING LEAKS. PLEASE GUIDE

  • @langitlama8015
    @langitlama8015 11 ปีที่แล้ว

    thank you :)

  • @Anupriya014
    @Anupriya014 13 ปีที่แล้ว

    nice presentation.. :) thnx

  • @somyaupadhyay8388
    @somyaupadhyay8388 8 ปีที่แล้ว

    nice dna bands are formed

  • @NetrapalSinghShekhawat
    @NetrapalSinghShekhawat 9 ปีที่แล้ว

    Nice