How To Troubleshoot HEUI Systems and IAP faults. 164 Faults. 3126, C7, and C9 Cat Engines.

แชร์
ฝัง
  • เผยแพร่เมื่อ 27 ม.ค. 2025

ความคิดเห็น • 303

  • @ryanburton6058
    @ryanburton6058 6 ปีที่แล้ว +9

    got a 3126 in a 2001 freightliner single axle 5 ton. approx 1 million km. Ive been the owner the last 50,000km. The previous owner told me he had the injector cups done once. Personally Ive only changed the oil. Its achieving acceptable blowby and oil use.
    Really like the engine, its very responsive and generally flawless in terms of operation. Great power for my application. I really like how the power increases through the gears. This aspect seems to be dialed in just right, very smooth and well tuned. I havent noticed the motor miss or skip a beat even once. Loving the cruise control, works very well. The borg warner turbo peaks at 23psi, which seems low, but im only running the 245hp setting. Great turbo good performance for my needs. Although loud at times this engine sounds manly and fun. Also the clutch is very good. Its Super smooth with a bit of practice and can handle a heavy duty sychro transmission just fine.
    As for some complaints... The 6 speed eaton trans in the truck is long geared. As such im shifting into 1400-1500 rpm often. This is not ideal cause the power output and lifter rattle in this range is not very good. The engine seems to operate best in the 1700-2300 rpm range. Although staying there at all times can be a challenge.
    And then there are leaks, the turbo side is bone dry at all times. Cant say the same for the intake side. the heui pump leaks from the front cover. The heui supply line leaks. The cam followers leak. The oil pressure manifold leaks. The oil pan leaks. Lets just say it leaks a little. Could fix it if I wasnt too busy making money every day.
    My attitude could change if I blew the heui system and went broke. But I wouldnt call it a boat anchor. Under the right care it can be considered reliable, and an all around nice engine. Best part is I only paid $8,000 for the truck. Some of my colleagues are $40,000+ into their rigs and spend lots of cash on EGR parts and exhaust filter problems. Not me im banking dollars daily :p

  • @jeetime9436
    @jeetime9436 ปีที่แล้ว

    Not a mechanic by trade but do know some maintenance. Your video was straight forward and in layman’s terms
    Well done

  • @michaelpatenaude5940
    @michaelpatenaude5940 7 ปีที่แล้ว +1

    You're correct it is 3126. After changing out fuel actuator which didn't work, I replaced fuel pressure sensor and that fixed the issue. Thanks for the response your videos are great.

    • @AdeptApe
      @AdeptApe  7 ปีที่แล้ว +1

      +Michael Patenaude Glad you found the problem and it was an easy fix.

  • @mikedurst8303
    @mikedurst8303 ปีที่แล้ว

    Thanks!

    • @AdeptApe
      @AdeptApe  ปีที่แล้ว

      Thank you so much.

  • @GWA1225
    @GWA1225 7 ปีที่แล้ว +1

    Your videos have been very valuable to me in understanding the C7 in my RV; I discovered you when I learned yesterday that I have a HEUI failure with metal in a couple injectors at 87k miles. One thing you haven't mentioned is whether an oil cooler failure or warpage can put metal in the oil supply and THAT failed it, as my CAT shop (which has a good reputation) is suggesting MIGHT.be the source. They point this out because if it is, the $6500 investment in the kit and it's installation can be trashed and the whole exercise re-done with the additional expense of the oil cooler. The cost Delta to do the oil cooler, they say, is about $1500 and they leave it to me to decide whether or not to go that route. I am very inclined to spend the extra money, because while I can afford to pay $8000 to fix this once, I'd rather not Pay a total of about $14,500 to fix it twice. What are your thoughts on this situation? You have not mentioned the oil cooler in your videos. Thanks very much.

    • @AdeptApe
      @AdeptApe  7 ปีที่แล้ว +5

      +GWA1225 At the time I made this video, I wasn't aware of the oil cooler possible failure. It is a concern though, the gasket can blow out between the filter housing and the cooler, causing unfiltered oil into the filtered side of the oil galley. You don't need to replace the cooler to check for this, only remove oil, check it for flatness and reseal if flat. Shouldn't cost $1500 for that. A HEUI kit shouldn't cost you $6500 installed. They are about $3600 parts and then about 12-16 hours labor in an RV which, by my calculations is about $5000-5600 all together. There is an update to the HEUI supply line they should know about that adds an inline filter to protect the pump. Make sure that is installed to protect the pump. If you have any questions, email me at AdeptApe@yahoo.com

  • @rudeboi2310
    @rudeboi2310 8 ปีที่แล้ว

    Awesome video! Its been some time since Ive worked with the CAT HEUI systems. Great refresher course and thanks for the help.

    • @AdeptApe
      @AdeptApe  8 ปีที่แล้ว

      +Dave Singh (rudeboi23) Glad I could help.

    • @canalsimonense
      @canalsimonense 6 ปีที่แล้ว

      Are you a CAT engine technician?

  • @shushucan6859
    @shushucan6859 2 ปีที่แล้ว +1

    Great video.

  • @fernandonava5792
    @fernandonava5792 8 ปีที่แล้ว

    Ok thanks for your help. I'm going to take the injector out to see if the o- rings are bad. video helped me out a lots

    • @AdeptApe
      @AdeptApe  8 ปีที่แล้ว

      +Fernando Nava None of them should be shooting oil out, that is probably your problem. They do purge a small amount out of the solenoid when running, but they should all be doing it the same

  • @sparky09100
    @sparky09100 8 ปีที่แล้ว

    thanks for the advice it sat for a year and a half and when i saw that little drip i thought bad the truck is not on the road so the best i could do is give it a good idle every so often and bring temp up till fan kicks on

  • @slowaf_12v
    @slowaf_12v 6 ปีที่แล้ว +1

    Great video!!! Good explanation of heui systems!!!

  • @kennethbullins445
    @kennethbullins445 8 ปีที่แล้ว

    At start-up C9 oil pressure is very high. With engine pre-heat it's 75 PSI, without it's over 100 PSI. Oil is bypassing the filter with this high pressure, so not good for HEUI pump. CAT 15w-40 oil takes to long obtained operating pressure. I'll received a fault code when engine load is high at high oil pressure. The fault immediately clears when engine load is reduce. When the oil pressure obtains operating pressure about 40 PSI, there's no fault. Still searching for the correct engine oil.
    Great information.
    Thank you

    • @AdeptApe
      @AdeptApe  8 ปีที่แล้ว

      Have you tried using the 10w30 Cat oil in that HEUI system yet?

    • @kennethbullins445
      @kennethbullins445 8 ปีที่แล้ว

      Adept Ape No, Yancey CAT only have 15w-40 oil on the shelf. I haven't ask if they will get 10w-30. I think my HEUI would appreciate CAT 10w-30, with the destination ECF-1.

  • @GIGABACHI
    @GIGABACHI 8 ปีที่แล้ว +1

    Awesome intel as usual. 👍
    Another video another lesson learned. 😎

    • @AdeptApe
      @AdeptApe  8 ปีที่แล้ว

      Intel! I like the sounds of that. Thanks for the comment.

    • @thetruth8958
      @thetruth8958 5 ปีที่แล้ว

      @@AdeptApe Do you know where is the fuel pump in 3126 box HEUE like what you have in the video and do you know cheap store or online website affordable price please or do you recommended used one from anyone you think they are not scam.

  • @dennishislop4428
    @dennishislop4428 2 ปีที่แล้ว +1

    why does my Check engine light does not comes on and the OBD indicate NO ENGINE.???????? PLZ THANKS.

  • @bosanacsoprano
    @bosanacsoprano ปีที่แล้ว

    Thank you sir! 🙏 great advice!

  • @kyleskustomkars
    @kyleskustomkars 7 ปีที่แล้ว

    Love your video, you did a good job explaining things.

    • @AdeptApe
      @AdeptApe  7 ปีที่แล้ว +1

      +Adam Kyle Thank you I hope it helped you.

  • @sparky09100
    @sparky09100 8 ปีที่แล้ว

    im actually thinking about going to uti diesel program and work on these cats instead of driving them plus knwoledge is good keep up with the excellent videos // wood like too see a cat rebuild video some day but there are none // your diagnostic videos help new guys for theyre schooling career alot

    • @AdeptApe
      @AdeptApe  8 ปีที่แล้ว +1

      I thank you for the kind words. You can definitely make a good living fixing Diesels. Your probably going to learn more about Cummins and Mercedes engines of you go to school because Cat doesn't make truck engines anymore.

  • @jackstowagegaming3600
    @jackstowagegaming3600 3 ปีที่แล้ว

    Excellent video

  • @dependablekit5500
    @dependablekit5500 9 หลายเดือนก่อน +1

    On the C7 sensor you said 6 to 10 ohms is that 6k to 20k or judt 6 to 10 also the sensor has 3 pins so test both outside pins to the center I'm currently working on a royal pain in the axx lol c7 truck is surging after it warms up with no codes it did have some events for low cranking pressure and I did reseal the injectors they where leaking using the primer pump any help would be much appreciated

  • @Mattye7584
    @Mattye7584 3 ปีที่แล้ว

    Great video mate! Thank you

  • @MarkWaldner-z7b
    @MarkWaldner-z7b 3 หลายเดือนก่อน

    i have a 3126 where the heui pump had external oil leaks and complaints of low power so i changed the heui pump even though it was keeping up with the commanded pressure, now it sputters when accelerating and still low power . thoughts .

  • @jorgebarrera8328
    @jorgebarrera8328 4 ปีที่แล้ว +11

    These engines seem very familiar to the international 7.3L on how they operate and the injectors look very similar.

    • @jimcalver-oj4xf
      @jimcalver-oj4xf หลายเดือนก่อน

      I had a 1995 F350 for many years with the international based turbo 7.3l with heui injectors. You are right these Cat engines look and operate similarly.

  • @sheldonbrown7240
    @sheldonbrown7240 19 วันที่ผ่านมา

    I have a Thomas school bus that was working great. Went to crank it it would just turn over and service guy replaced the pump and still didn’t crank so the next service guy said the ECM was dead and replaced it with aftermarket one and it cranked started to drive and shift from 1st to second then went in derate mode. Now I have it at a caterpillar shop and still no codes. Is there something else before I buy another ECM

  • @heromungus5
    @heromungus5 หลายเดือนก่อน

    How do you remove the Quick connect oil supply line 3126b?

  • @dslfrk59
    @dslfrk59 3 หลายเดือนก่อน

    NEED HELP we have a 2003 3126 that will shut off after 30 minutes or so, let it cool for 1-15 minutes and it starts right back up. It's instant too and it starts right away when it cools. Doesn't act like heui issues seems seems electrical. I have 2 battery + and - at ecm and 1 ignition + and none are dropping out when it dies. Changed timing sensors and heui oil pressure sensors. Scan tool looses communication when it shuts down as well. We also swapped ecm and does same thing.

  • @ronbown3836
    @ronbown3836 ปีที่แล้ว

    So I'm getting a no-start issue after engine warms. Start when cold but after warmed up a can't restart it. Could that be a Heui pump?

  • @Stewart-iw4pu
    @Stewart-iw4pu 2 หลายเดือนก่อน

    Hey Adept ape, I have a problem with an engine oil leaking from the turbo charger and the pressure dropping slowly when running on idle without loading it and would very much appreciate your help?

  • @IndependentMechanic
    @IndependentMechanic 4 ปีที่แล้ว +1

    I have a c7 in a freightliner that only show's .5 gph fuel rate. I performed the actuation pressure and cutout tests that looked great. I have extended crank, miss, fuel knock, hesitation etc. No codes except for low cranking pressure but its an old code.

  • @protectionplus100
    @protectionplus100 5 หลายเดือนก่อน

    Need Help... I have two rollbacks with the Cat. 3126 Turbo deisel.. takes fuel fine, unless you have pedal all the the way down with the weight of the rollback going up hill.... down to 30mph on some hills.. blue smoke, no power under strain... even it's own weight up hill.

  • @edgardoelona2949
    @edgardoelona2949 10 หลายเดือนก่อน

    Dear Sir, we have cat C7 accert marine engine what is the probably cause " LOW FUEL PRESSURE" message from display.We change the relieved valve but still the come out again and again.thanks

  • @ronaldjavier1512
    @ronaldjavier1512 7 หลายเดือนก่อน

    Sir, what to check clutch pressure alarm in caterpillar engine.

  • @josephphillips7165
    @josephphillips7165 ปีที่แล้ว

    I have a motorhome with the C7 and having a fuel problem. Do you know how the ecm works in the 2006 winnebago? Where it is?

  • @charlielovell9897
    @charlielovell9897 ปีที่แล้ว

    Could the HEUI pump cause an extended crank on a 3126

  • @mikeblake6265
    @mikeblake6265 ปีที่แล้ว

    Will the pump throw this 164-4 code had at 2 shops 1 of witch said motor needed new rings I had put new injector seals in it replaced pressure sensor on head still have crank no start or really bad running when does start engine protect light and engine light comes on lose of all power

  • @lcmedicman
    @lcmedicman 2 หลายเดือนก่อน

    What do you use for your code reader/trouble shooter?

  • @JoedyFlynn
    @JoedyFlynn ปีที่แล้ว

    Hello, I have a C7 "JTF". Excessive oil consumption complaint , about 8 L in a 12 hour shift.. Found oil in the fuel so replaced injector o-rings and cups about 6 months ago. The lift pump looks new, HEUI looks new, Turbo is not leaking oil, no oil in the exhaust no smoke, air compressor carrying oil out so disabled it.
    Wondering if you have any methods for testing oil in fuel? Any help would be appreciated.

  • @DonSchmidt-n2h
    @DonSchmidt-n2h ปีที่แล้ว

    I need some help here. My 3126 is down and its the system i think. Fires on ether. Crank no start. Just died on me backing out the garage fixing issue none related to this. Had a computer on it saying it met desirables on pressure while cranking. Found a 164-3 code. High voltage to iap sensor. Replaced iap and ipr(iap valve on pump). Any ideas

  • @ShadrickSimbaya
    @ShadrickSimbaya 7 หลายเดือนก่อน

    My cat cylinder no 3 ive changed theinjecto but to no avail so what could be the problem

  • @bluegarren9361
    @bluegarren9361 2 หลายเดือนก่อน

    Specifically what do you need to communicate to the engine?

  • @magarinmoreno
    @magarinmoreno 2 ปีที่แล้ว

    My freightliner cat c7 it's returning oil to the fuel tanks?
    I was advised by mechanic that the HEUI pump it's the cause of my oil "disappearing". Around 2 gallons of oil consumed on a day (450 miles). When looking at the tank it's black and we're advised it's oil.
    I'm not sure about it, what are your thoughts?

  • @MrJerryjam
    @MrJerryjam 5 ปีที่แล้ว +1

    A question about: the fuel flow from the filter thru the pressure regulator on the Cat 3126 2001\2002 build. Question: Would installing an electric fuel pump between the fuel filter and the fuel transfer pump allow the bleeding of air from the head in the event of the failure to prefill the fuelfilter\filters? Would the additional pump allow any air to pass thru the pressure regulator and allow fuel to be circulated bank into the fuel tank?

  • @peterlahai7990
    @peterlahai7990 10 หลายเดือนก่อน

    Thanks for the video. I have a 2009 f750 7.2l it starts ,run and shutdown after 1 minutes and will start right back and there is a sign on cluster stop engine. .I need some help please. Thanks

  • @rodgedaddy
    @rodgedaddy ปีที่แล้ว

    working on a c7. runs like crap. 102-4 was active but after a few minutes of running, went logged. inside logged events, 164-11 code found. cylinder cut out test shows to have 2 inactive injectors. should this be the 164-11 event?

  • @walterrolon6912
    @walterrolon6912 3 ปีที่แล้ว

    Hey buddy can you tell me what are comon causes of lot of fuel on engine oil oc c7 replaced injectors orings and same trow a set of used injectors and same
    please help

  • @emontgomeryjr
    @emontgomeryjr 2 ปีที่แล้ว

    I have a motor home with a C7. Sat for couple years. I did start it and run once in a while. I can’t seem to get fuel to the inlet of primary filter. I drained tank and added fresh fuel. Replaced both fuel filters. I did replaced the fuel regulator today. Have a hand prime pump but it never gets hard to push after priming 100’s of times. Cat dealer replaced HUI pump and injectors a few years ago so I’m hoping it’s not that. Any ideas as to why no fuel to the primary fuel filter?

  • @holeshot1721
    @holeshot1721 4 ปีที่แล้ว

    I bought a 2000 gmc 7500 box truck and it came with no ecm can i buy any ecm for the 3126 cause that’s the motor thats in there to get it to drive?

  • @jmyhre5251
    @jmyhre5251 5 ปีที่แล้ว

    I have a C7 ACERT in a FMTV military truck. Cranks-no start or attempt to start. There is no fuel pressure at all at the secondary fuel filter and I swapped out the fuel pressure regulator-same thing. I have not yet checked fuel pressure out of the transfer pump. The driver on the HEUI pump is 8.3 ohms. The vehicle has been sitting for a long time and had water in the fuel and even some rust in the fuel filters. Before testing fuel pressure I drained the fuel tank and put new fuel in the tank and also changed out the filters / primed system. Is it best to change out HEUI pump AND also the injectors since the fuel was contaminated badly?

  • @johngrzibowski1519
    @johngrzibowski1519 ปีที่แล้ว

    I'm using a gallon of oil each day i run my truck. 3126. going into fuel . How to check Heui or injectors.

  • @wbarney59
    @wbarney59 7 ปีที่แล้ว

    thanx josh you helped me again

  • @DavidDallas3343
    @DavidDallas3343 5 ปีที่แล้ว +2

    My question is this what fails in the Heui pumps on the 3126e

  • @fapolanco1245
    @fapolanco1245 6 ปีที่แล้ว

    My truck has a misfire I have no way to communicate with the ecm I’ve replaced tue huei pump and stil cuts off when Im after 3rd gear ⚙️ check remove the valve cover to check for leaks seems like a lot of oil is coming out of the injectors but don’t know if that’s normal any ideas 💡

  • @00Blqze
    @00Blqze 8 ปีที่แล้ว +1

    Hey man it would be very interesting if you did a day in the life i would love it im in highschool and i want to be a diesel mechanic at CAT. Thank you pleas keep up the great work!

    • @AdeptApe
      @AdeptApe  8 ปีที่แล้ว +5

      I've actually been thinking of like strapping my gopro to me throughout the day or just doing like 20 snippets of the day videos and then doing a compilation of them. It is a good idea and now that I know other people think so too maybe I'll do one.

    • @00Blqze
      @00Blqze 8 ปีที่แล้ว

      +Adept Ape Thank you man it would be great

    • @robbiepinkham3739
      @robbiepinkham3739 6 ปีที่แล้ว

      Adept Ape .hello help.. motor starts and runs good but losses fuel in the filter after u shut it off.. ??

  • @GTRaceVid
    @GTRaceVid 7 ปีที่แล้ว +1

    Can you tell me what you said from 5:30 to 5:33 in the video it sounds like you said you have never seen that be the cause unless it says injection actuation pressure sensor( forward chime)
    What is forward chime...or did I mishear something

  • @gergmeister1
    @gergmeister1 29 วันที่ผ่านมา

    I ordered a new replacement actuation valve for our 3126 HEUI (aftermarket p/n: 1225053) to replace the old valve. I tested the new valve coil at 36.2 ohms; is this considered ok,? or would it be possible that it's the wrong part?
    I've been watching your much appreciated video's , and as you've said, the ohm reading should be between 4 to 16 ohms.
    Thank you for your professional knowledge!!

  • @ericanderson9345
    @ericanderson9345 2 ปีที่แล้ว

    Have a 2001 renegade with a cat 3126, cranking but doesn’t start, runs off starting fluid but doesn’t continue to run, It’s been sitting for years so I think it’s either the transfer pump or the heui pump but both are expensive and idk how to tell which one, what kind of scanner do I need to check for codes?

  • @patrickondego5540
    @patrickondego5540 หลายเดือนก่อน

    Good day Adept. Nice stuff and highly apprciated. I have a marine engine which has a newly installed pump that is not keeping up with the load demand - i.e RPM cant increase to the normal 1800 only goes upto 1100. Ill appreciate you input

  • @ninte4th
    @ninte4th 4 ปีที่แล้ว

    Got i C9 giving 42-05 current below normal in crane operation.
    1.replace ECm,wiring harness, injectors,HUEI pump
    Engine hunting when ramp up to 1800rpm.

  • @nutsplitter
    @nutsplitter 6 ปีที่แล้ว

    I have a 1999 Newmar Dutchstar Motorhome with 170K miles and a Cat 3126 Diesel. On a return trip from ND this summer it suddenly slowed to 40mph while travelling down a freeway. I could not get it above 40. I could slow down and speed back up to 40 but nothing faster. I decided to pull over and it died and would not start again. Afterr about a 1/2 hour of calling around, it did start but again would only go 40 max. I limped it to the next exit and called for a tow.
    The towing company also did minor servicing and suspected clogged fuel filters, which they changed, numerous times but did not fix the situation. They noticed the diesel fuel was dark with oil and suspected blow by from a cracked piston, o-rings or cracked head. They replaced the o-rings which seems to have helped the discolored diesel, but did not fix the speed or starting issue.
    I should mention that the RV would start with ether and if I was lucky and could get the vehicle moving, I could limp down the road but it seemed after the engine was warm and it died, it would not start until some time passed or ether was used.
    Also the OBDC is not producing errors. When the 40 mph govenor kicks in the Engine light does come on but does not pass any codes. After apparent cooling down, the Check Engine light goes out as if nothing is wrong only to reappear after a while.
    The shop now suspect the HUEI. They are not a highly knowledgeable professional diesel service/shop but are trying to help me by keeping my costs down. Although trial and error and parts changing may work, it's been 2 1/2 months now and would like to get this resolved.
    Any help, thoughts, comments, kick in the pants would be greatly appreciated.
    Thanks in advance!

  • @JoseLopez-zc8ed
    @JoseLopez-zc8ed 3 ปีที่แล้ว

    My problem with a cat c7 is low oil pressure, change the pistons, all the metals inside the new oil tank and the head rubbers, and nobody understands why there is no pressure. question ? can be heui pressure pump

  • @marcosvillalobos6845
    @marcosvillalobos6845 2 ปีที่แล้ว

    Hey brother thanks for Information I have a 05 freightliner with a c7 that currently has a slight miss at low idle my fuel pressure is good and oil pressure so I removed valve cover and I can see that 2 of my injectors are squirting oil from the actual injectector itself and nor from the seals below it , is that a sign my injectors are failing ? Also had injector harness unplugged while I cranked to prevent mess?

  • @philholloway5272
    @philholloway5272 7 ปีที่แล้ว +3

    Hi there I'm having trouble with a 336d running a c9 that refuses to start when warm unless it gets a squirt of ether I'm thinking huei pump or faulty injector am I on the right track?

    • @AdeptApe
      @AdeptApe  7 ปีที่แล้ว

      +phil holloway If it has a cold miss, that is usually an injector. You can do a cylinder cutout test right when it starts to see if you can identify which one.

  • @mikejaques6573
    @mikejaques6573 ปีที่แล้ว

    I really enjoy yiyr Cat videos I have a car c9 in a bus. I was having surging read the dipstick correctly or GLASSES I’m old. I was 7 quarts low now runs excellently. I wonder can o make an immune filter system for a cat c9 or can get them now. Thanks for any reply

  • @margomarin1181
    @margomarin1181 4 ปีที่แล้ว

    Have c7 10 oms good. If I clear codes and history engine not running. I get the flashing light on the dash. I haven't even started the motor. Would this indicate a wiring issue. I had to put injector seals they were gone. The harness to injectors was in bad shape and 1 injector failed on test. I can't get the flashing to stop. I need advice on what to do. Please. Great video!

    • @kanasney1793
      @kanasney1793 2 ปีที่แล้ว

      Hey I have the same problem now 😢😢

  • @LeeMatczak
    @LeeMatczak ปีที่แล้ว

    I have an rv with a 04 cat c7. It is a 350 hp engine. Upon start up when it sits overnight, it will throw the ck engine and engine protect light upon start up. Codes 164-2 and 164-0 are the only codes in the system. When it starts it will seem to run a little rough and seems more black smoke than usual but I never paid much attention upon start up because I am inside. It stalled twice on me. Both times when the lights were on. I had to turn the key off and try to start it again because it would not start until I shut the key all the way off. Once I did that it started right back up. If the light come on when I start it, I turn the key off and start it again and the lights are off. It never had low power and still doesn't once those light are out. I put my scanner on it to test the actuation pressure, and it did go all the way up and down, but seemed a little delayed in response. Any suggestions? PLEASE!!! Supposed to leave for vacation in 2 weeks and need a vacation not a vacation to HELL though. Thanks in advance

  • @bolajiayodele4582
    @bolajiayodele4582 2 ปีที่แล้ว

    I have a C7 that’s reading no codes but won’t start. Could you help?

  • @indyvision4157
    @indyvision4157 5 ปีที่แล้ว

    I Have a 2006 c7 and it is surging badly when accelerating under load.It shakes the truck badly. It also surges or has a "choppiness" when revving the engine in neutral. It does have a light unevenness when you let go of the throttle from a rev. Have any thoughts???

  • @hectorsantos1970
    @hectorsantos1970 3 ปีที่แล้ว

    Good afternoon I have a 3126 cat engine with 145,000 miles I am having a issue with it while using it it feels like it get air or like if it wants to turn off we stop the truck and put the transmission in neutral and press the diesel pedal and it goes way and we keep driving fine
    And once in a while while the truck is stopped but running it will turn off and we go turn it on again and it stars right away ???? Any idea what it could be ??

  • @antreasiona6033
    @antreasiona6033 2 ปีที่แล้ว

    I have generator c7 and I would like to know the maximum and minimum injector pressure

  • @TheYnnad77
    @TheYnnad77 3 ปีที่แล้ว

    Why does my cat c7 have a fuel knock until I unplug the huei pump driver?

  • @louielemburg1034
    @louielemburg1034 4 ปีที่แล้ว +1

    Thanks for the videos... need help. 1997 3116 Heui... Starts easily, runs great, low power. No boost to speak of. I just got the J1708 rewired to a regular truck connector and can talk to it now. Without Cat ET I only see fuel pressures, not requested (yet) working on codes for that data point... Pulled the Fuel actuator IACP and pulled it apart, and cleaned it. no change. Checked the intake air pressure sensor, clean. I only see up to ~20psi boost then it drops back to 18 even on the floor. can't get over 40 mph.
    Heeelllppp. suggestions are welcome.

  • @robertosoares1902
    @robertosoares1902 6 ปีที่แล้ว +1

    I have a cat engine 3412E showing the following defect
    in the first cold start the engine runs but in the second start the engine does not work only by applying ether in the turbine
    What can be
    thank you

  • @admiresavanhu6157
    @admiresavanhu6157 5 ปีที่แล้ว

    Hi there I have a C7 that has injector 1 and 2 not firing. I have since confirmed its not the injectors we I swoop them around and they fire. I suspect it could be the ECM because all injectors squirts oil and if I pull out the plug it stops squirting. I tried the cylinder cut out test but you can hear there's no change in sound or rpm or fuel pressure unlike injectors 3 - 6. Can you please help with any advice. Our big problem is we don't have another test ECM so I want to make sure before buying one. Thank you

  • @fernandonava5792
    @fernandonava5792 8 ปีที่แล้ว

    sorry to bother u again. so took off the valve and cranked it over and i notice that one of the injector was shooting out oil through the side does that mean i have a bad o rings on the injectors? and when it start up that was the only one with oil shooting out. thanks

  • @fernandonava5792
    @fernandonava5792 8 ปีที่แล้ว

    it has a new IAP and what i call ipr for the heui pump. i work with powerstrokes and i know that they are alike. i don't a scanner to check my pressure, so I'm not sure how to go about to see if i have desire pressure that it needs to fire the injector.

    • @AdeptApe
      @AdeptApe  8 ปีที่แล้ว

      Really the best way is to get a scanner, but if not you could use a high pressure hydraulic gauge set that is rated up to 5000 psi and install it in the HEUI oil rail, you need about 850 psi at cranking to fire.

  • @MissingLinkMTB
    @MissingLinkMTB 5 ปีที่แล้ว

    Have one running like it's got a cam in it at idle... running it feels like a miss. On the test drive I go into Injection Actuation Pressure Test, Start Test, runs smooth as butter immediately. At 870 it ain't got the power to drive the mountains of course. I push up the pressure to max and she runs like a scalded dog. Pressures max, expected to actual match up. Ran like that for a bit. Cut off the test and the engine runs normal. Drove around a bit and still no problems. It was recently serviced. Any chance there was debris in the injectors and pushing the pressures blew it out or should I be looking into this more?

  • @tcrooks7701
    @tcrooks7701 3 ปีที่แล้ว

    Hi there I have 3126b in an 2001 fl70, the engine is sputtering if the outside air temp is hot. Doesn’t matter if the engine is cold or hot. But on a colder day. The engine will run nice and smooth until I have to really put it work(climbing a hill loaded or something like that), i have changed the Heui pump, fuel transfer pump, the actuator on the heui pump, the oil pressure sensor, the check valve on the rear on the engine, the fuel pump in tank, and of course new filters and oil and lots of fuel. the truck doesn’t have any codes and doesn’t have any kind of smoke coming out of it. Do you have any suggestions for me to check next? Thank u

  • @teamklr2bar
    @teamklr2bar 6 ปีที่แล้ว

    I have a 3126 with a bad HEUI. It looks like the one I -this video with the filter housing/reservoir on top. (Not sure what it is) so if I were to replace the pump do I need to do anything with the computer to reset it?

    • @AdeptApe
      @AdeptApe  6 ปีที่แล้ว

      +TDCtactical You don't need to do anything with the ECM to change the HEUI pump.

  • @briangunter2824
    @briangunter2824 7 ปีที่แล้ว

    Great video. Working on a 04 IC DT466. Starts great and runs great until it gets hot. Injection control pressure drops way off and it wont start again once engine is shut off. Then when it cools off BAM starts and runs great until it gets hot again. Should I look under the valve cover PITA, or suspect the HPOP. Thanks again!

  • @gunks_getaway
    @gunks_getaway ปีที่แล้ว

    You're saying it's more common to replace the whole HUEI pump, than the seals going bad on the injectors? ( 5:18 )

  • @PI4YOU
    @PI4YOU 5 ปีที่แล้ว

    a 1998 Kodiak with a 3116 HUI. I used it to move parked it 3 years ago and want to start it. Fuel evaporated from the tank, added 5 gallons. Tried pressurizing the fuel tank with 15 ish psi and no fire. What should I be doing? tia

  • @cwclark4188
    @cwclark4188 3 ปีที่แล้ว

    Hey this is Chris with a 2006 bounder with c7 cat when I was going through mountains the engien light came on and reduced power happened when I got out of mountains it ran great do you think a barrow problem thanks

  • @anthonywolden9242
    @anthonywolden9242 6 ปีที่แล้ว

    Ok I have a 3126 pulled the valve cover off no oil when u crank on it. So do I need to change the heui pump or is there something else to check before I order a pump???

  • @shushucan6859
    @shushucan6859 2 ปีที่แล้ว

    Heui pump percentage only goes up too 45% any explanation for this? Thanks

  • @mrfasttap7574
    @mrfasttap7574 7 ปีที่แล้ว +1

    I have a Cat C-7 eng# WAX54111 I have extreme high pressure oil pressure at crank and idle approximately 4000-4500 psi changed IPC sensor HEIU pump ecm traced and inspected wiring any other ideas as to why this issue is occurring advice would be much appreciated.

  • @AhmadAli-mx3xn
    @AhmadAli-mx3xn 8 ปีที่แล้ว

    thnx again it is very useful . but I have another question maybe u could help me with . I have a Perkins 1103 generator set . but it stalling and die under load .

    • @AdeptApe
      @AdeptApe  8 ปีที่แล้ว

      Does the annunciator panel have any of the warning lights come on when it stalls?

    • @AdeptApe
      @AdeptApe  8 ปีที่แล้ว

      +Ahmad Ali So you put the unit under load, it stalls with lack of power, then shuts down for under frequency/under voltage? It sounds like a horsepower problem. You need to check the Turbocharger and the intake tubing and aftercooler for leaks first thing. Does it run smoothly under no load or does it have a miss?

    • @AdeptApe
      @AdeptApe  8 ปีที่แล้ว +1

      +Ahmad Ali Normal breath? Do you mean it doesn't have a turbocharger? Is it a Diesel or gas engine then?

    • @AhmadAli-mx3xn
      @AhmadAli-mx3xn 8 ปีที่แล้ว

      +Adept Ape it is a 3cylinder diesel

  • @thejimatch89
    @thejimatch89 5 ปีที่แล้ว

    So, I have a 3126 with a intermittent issue. While under way, i hear will the engine "grunting", then for no apparent reason will stop grunting and smooth out. When it smooths out, I can hear the turbo more clear and it runs like a top. Most times it will not clear up, and for better words is a complete dog! I have done injector cups, and have changed the fuel filters 20 times or so.(in hopes it will run like it should). I have no check engine lights. I noticed the other morning, I started it and the rpms jumped to 1000 rpms or so as if I patted the pedal a couple times. It ALWAYS STARTS, and has never left me stranded. KOW. Any help would be great. I appreciate your videos. Where are you located?

  • @Diesel_Monkey_Tx
    @Diesel_Monkey_Tx 4 ปีที่แล้ว

    Hey there. I am working on a C9 that surges while accelerating until it gets above 1600 RPMs. I’ve noticed the actual injection pressure is higher by 2-600 psi while it’s doing this and once it calms down it read close to the desired. Where do I even start. I have CAT ET and am familiar with the heui system but never seen one do this.

  • @mitzvahgolem8366
    @mitzvahgolem8366 6 ปีที่แล้ว

    Excellent Thanks you. What is a good scan tool for occasional use?

  • @ovidiofs1
    @ovidiofs1 8 ปีที่แล้ว +1

    thanks Ill check; I had a bad injector before but my mechanic fixed it, the control valve of heui has 9 ohm and the sensor gets 5 volts in, .9 volts at idle when rev it up going up, and ran well but it show those codes ..thanks Iam learning a lot of mechanic with you and your videos are helpful and interesting thanks for your time body

  • @capybobs2
    @capybobs2 5 ปีที่แล้ว

    Excessive smoke and sluggish performance on 2006 c7 475 hp marine Is thus indicative of injectors hanging up?

  • @ryeckley7267
    @ryeckley7267 4 ปีที่แล้ว

    at 8:11, whats a driver? it looks like you have the leads connected to the ipr regulator

  • @mag2395
    @mag2395 5 ปีที่แล้ว

    Working on a c9, truck starts fine cold, but when warm the truck will not start. IAP is commanding 700 psi but when the IAP test is ran it will not go over 700 +- , even when commanded 3300 psi. Output is sitting at 99% during test the whole time. Any thoughts? Huei pump? Checked for injector seal leak and no leaks when cranking.

    • @ronbown3836
      @ronbown3836 ปีที่แล้ว

      I'm having the same thing going on with my GMC c6500.

  • @fernandonava5792
    @fernandonava5792 8 ปีที่แล้ว

    on the video u said to take off the valve cover to see if oil was coming out of the injector, is that another way to determine if my heui pump is working if the if oil shoots out? how would you determine if the injector themselfs are leaking?
    i wanna say thank you for help me out on this cat engine.

    • @AdeptApe
      @AdeptApe  8 ปีที่แล้ว +1

      Your injectors purge small amounts of oil when running, but if one is spraying oil or purging a lot more than the others you have a problem with that injector.

  • @kirkmiller8409
    @kirkmiller8409 6 ปีที่แล้ว

    when i do the injection actuation pressure test i cannot get pressure into the 3000 it will code out on me and get the 164-2 code i have i to shut the truck off and start again iap test wont respond plus i am getting 64-2 and 64-11 driving me crazy please help

  • @deanbrotzman7889
    @deanbrotzman7889 3 ปีที่แล้ว

    the heui pump om at 10.1 the pressure was bouncing from 2400 to 5200 as we werechecking conections we lost pump data

  • @TheYnnad77
    @TheYnnad77 3 ปีที่แล้ว

    Can the injector pressure sensor be at fault?

  • @jerrydudley7372
    @jerrydudley7372 3 ปีที่แล้ว

    Does a 3412e have a Huei pump?

  • @manlo7704
    @manlo7704 6 ปีที่แล้ว

    Hello, how about I changed one of my injectors (#5) and vehicle is still losing power. Not sure if the ECM is bad or the HEUI pump is bad. Please help... Thank you!

  • @craigjohnson6025
    @craigjohnson6025 8 หลายเดือนก่อน

    I have a 3126 i put a new heui pump on it it still will not start I have loosened the fuel lines one at a time and not fuel is coming in new fuel filter already installed

  • @wesleyyamahar1
    @wesleyyamahar1 2 ปีที่แล้ว

    This is very helpful.
    Thanks for making the video. What kind of software do I need to troubleshoot the 3126. I have been having issues and the dealership around me is terrible at helping even finding the right issue. Thank you.

  • @crrassh
    @crrassh 5 ปีที่แล้ว

    I did that pressure test like you did and mine will to 3300 psi but when at that pressure the engine is surging or hunting is this normal? Thanks