Sir Can you pls help me at the following; 1. I have seen many videos showing that if we are making 4 inch walls then we should provide a RCC band at 3 feet height in full house with at least 2 sariya of 8 or 10mm in then so that walls remain straight & if any earthquake comes then cracks do not go beyond this RCC band but my contractor says that he has seen in many such places where band is given with sariya in it, the bricks donot form proper bond with RCC and develop cracks from there, moreover he also says if we put sariya in outer walls then after few years rust starts coming out if those walls n can be seen on walls as these walls come in contact of rain etc Pls tell if he is correct or not ? I have framed structure in delhi & wall distance between pillars is not more than 15 feet. My outer walls will be of 6.5 inch as both sides of 4 inch walls, I will be putting tiles. Lastly is it good to give 4 inch RCC linter beat at 7 feet height in full house rather than just above windows n doors. I will be obliged. 🙏🏻
🟢 𝐅𝐨𝐫 𝐨𝐟𝐟𝐥𝐢𝐧𝐞 𝐓𝐫𝐚𝐢𝐧𝐢𝐧𝐠/ 𝐨𝐧𝐥𝐢𝐧𝐞 𝐥𝐢𝐯𝐞 𝐬𝐞𝐬𝐬𝐢𝐨𝐧 𝐨𝐫 𝐚𝐧𝐲 𝐚𝐬𝐬𝐢𝐬𝐭𝐚𝐧𝐜𝐞 𝐲𝐨𝐮 𝐦𝐚𝐲 𝒄𝒂𝒍𝒍 𝒐𝒓 𝑾𝒉𝒂𝒕𝒔𝑨𝒑𝒑 𝒂𝒕 +𝟵𝟭𝟵𝟳𝟭𝟭𝟭𝟱𝟱𝟱𝟴𝟱
🔴𝐅𝐨𝐫 𝗥𝗲𝗰𝗼𝗿𝗱𝗲𝗱 𝐬𝐞𝐬𝐬𝐢𝐨𝐧
𝐃𝐨𝐰𝐧𝐥𝐨𝐚𝐝 𝐑𝐞𝐢𝐧𝐟𝐨𝐫𝐜𝐞 : 𝐂𝐢𝐯𝐢𝐥 𝐄𝐧𝐠𝐢𝐧𝐞𝐞𝐫𝐬 𝐥𝐞𝐚𝐫𝐧𝐢𝐧𝐠 𝐚𝐩𝐩.
👉𝐀𝐧𝐝𝐫𝐨𝐢𝐝 𝐚𝐩𝐩 𝐥𝐢𝐧𝐤 : bit.ly/425ebrk
👉𝐖𝐞𝐛/𝐏𝐂/𝐋𝐚𝐩𝐭𝐨𝐩 𝐋𝐢𝐧𝐤: web.reinforceqst.com/
👉𝐌𝐲 𝐢𝐧𝐬𝐭𝐢𝐭𝐮𝐭𝐞 𝐚𝐩𝐩 𝐟𝐨𝐫 𝐈𝐎𝐒 𝐥𝐢𝐧𝐤: apple.co/3HFwBqo
Org code : avywj
📧 Email : reinforceqst@gmail.com
🌐 Website : www.reinforceqst.com
Very informative video.. thanks to Reinforce
Try to make a video on joints in concrete
Great work
Good job
Do we need concrete band while using light weight blocks and chemical?
Sir
Can you pls help me at the following;
1. I have seen many videos showing that if we are making 4 inch walls then we should provide a RCC band at 3 feet height in full house with at least 2 sariya of 8 or 10mm in then so that walls remain straight & if any earthquake comes then cracks do not go beyond this RCC band but my contractor says that he has seen in many such places where band is given with sariya in it, the bricks donot form proper bond with RCC and develop cracks from there, moreover he also says if we put sariya in outer walls then after few years rust starts coming out if those walls n can be seen on walls as these walls come in contact of rain etc
Pls tell if he is correct or not ?
I have framed structure in delhi & wall distance between pillars is not more than 15 feet. My outer walls will be of 6.5 inch as both sides of 4 inch walls, I will be putting tiles.
Lastly is it good to give 4 inch RCC linter beat at 7 feet height in full house rather than just above windows n doors.
I will be obliged.
🙏🏻
Which is code?
Should RCC Band provide in all floors or only for ground floor?
As per your budget,, you can give
U have half knowledge..sill band must be given coulmn to coulmn not only in window regions as u suggested