Now All We Need's a Generator...

แชร์
ฝัง
  • เผยแพร่เมื่อ 27 ธ.ค. 2024

ความคิดเห็น • 62

  • @blueleafs2874
    @blueleafs2874 5 หลายเดือนก่อน +1

    Amazing absolutely loved this.

  • @WillLeingang
    @WillLeingang ปีที่แล้ว +1

    This is amazing and your “customer” is my hero.

  • @donl1410
    @donl1410 ปีที่แล้ว +7

    14:32 . Where are the cable connectors securing the SER cable to the two loadcenters, per NEC 338.10(B)(4)(a)(1) and 334.30?

  • @speednutsII
    @speednutsII ปีที่แล้ว +3

    The talk about mistakes and how to handle them at 15:30 ish mark is absolute money.

    • @EVMacD
      @EVMacD ปีที่แล้ว +1

      Especially when he’s holding the heart zapper 2000 in his arm pit. Not energized fortunately.. his comfort around big voltage gets my respect.

    • @mathman0101
      @mathman0101 ปีที่แล้ว +1

      Absolutely I wish more contractors and trades would take that responsibility seriously.

  • @mcarroll598
    @mcarroll598 ปีที่แล้ว +10

    Don’t you need connectors on the sub feed wire between the 2 panels in the garage? And most likely nail plates?

  • @waynejanik9668
    @waynejanik9668 ปีที่แล้ว +8

    Thank you for sharing. I wish more contractors would work with DIYers and I believe it would reduce the amount of bad DIY installs and increase safety. Great work and great partnership. you all be safe.

    • @russrockino-rr0864
      @russrockino-rr0864 ปีที่แล้ว +2

      Diyers want to work with contractors, but don't want to pickup the tab for the extra time they cost the contractor. I have seen this dozens of times in my career.

  • @Fazer07
    @Fazer07 ปีที่แล้ว +11

    You don’t need to pull the fuses in the transfer switch. You can just unplug the molex plug on the sacm board. Those fuses break easily when installing them.

    • @rupe53
      @rupe53 ปีที่แล้ว +2

      @daniel lothamer ... I have to say that load manager is great, but they really did screw up by using to those tiny fuses in a tight space. This is from a 25 year Generac tech who is now retired.

    • @rj44319
      @rj44319 ปีที่แล้ว

      I was thinking the same thing

  • @Eddy63
    @Eddy63 ปีที่แล้ว +2

    Awesome series Joel ... Thx for sharing ...

  • @josephnicolas2158
    @josephnicolas2158 ปีที่แล้ว +2

    Amazing videos! Thank you 🙏

  • @norsk54472
    @norsk54472 ปีที่แล้ว +2

    love it. learned a lot. great video presentation

  • @christopher20008
    @christopher20008 ปีที่แล้ว +2

    Great job, always professional

  • @benjaminvivar7855
    @benjaminvivar7855 ปีที่แล้ว +3

    Great job Joel,
    Preach it brother
    Very inspirational.👍

    • @donl1410
      @donl1410 ปีที่แล้ว

      Yep, spends a lot of time preaching...

  • @rj44319
    @rj44319 ปีที่แล้ว +1

    What is that black heat shrink looking material covering the exposed wire in the romex on thw second pannel?

  • @russrockino-rr0864
    @russrockino-rr0864 ปีที่แล้ว +4

    Joel. Why am I seeing large PVC male adapters being used on ser cable instead of se clamps? Fire could get out and start the wall cavity on fire.

  • @stevesolt4036
    @stevesolt4036 ปีที่แล้ว +3

    How are you able to feed that sub panel using pvc male terminal adapter without any cable restraint

    • @donl1410
      @donl1410 ปีที่แล้ว +1

      I'm sure he'll say the AHJ allows it or some other BS. If he replys at all.

  • @danlah1303
    @danlah1303 ปีที่แล้ว +2

    I had a Generac dealer try to upsell me because of the combined LRA of my 2 AC units starting up exceeded the surge amp rating of the model I was looking at. I look back now and wonder did he not know the transfer switch included AC load management so both units don't start at the same time, or was he being dishonest.

  • @leonardhuffman2644
    @leonardhuffman2644 ปีที่แล้ว +1

    Is an emergency disconnect between the meter and Generac transfer switch not required?

    • @leonardhuffman2644
      @leonardhuffman2644 ปีที่แล้ว +2

      Answering my own question, the transfer switch used here is service rated and would be considered an emergency disconnect. Generac also makes a non-service-rated transfer switch.

    • @sungkim16
      @sungkim16 ปีที่แล้ว +1

      Never have I installed a separate disconnect for the generator. The transfer switch is your disconnect.

  • @jsteve8139
    @jsteve8139 ปีที่แล้ว +3

    As a lowly newbie why do you need a transfer switch and a disconnect? Is it just pure safety or is there code in relation to that?

    • @rupe53
      @rupe53 ปีที่แล้ว +2

      some areas require it due to distance. The gen set they will use already has a breaker and an exterior shutdown for FD emergencies.

  • @cengeb
    @cengeb ปีที่แล้ว +1

    Are those metal NM cable clamps on top of the panel rated for 2 NM cables?

  • @shawnphillips1220
    @shawnphillips1220 ปีที่แล้ว +1

    Why are the circuit lines in the attic black like they've been overheating? Is that normal??

  • @cengeb
    @cengeb ปีที่แล้ว

    RESPECT MY AUTHORITY!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! Too many people have that issue

  • @markelliott7917
    @markelliott7917 ปีที่แล้ว

    In Ontario Canada we wouldn't be allowed to use PVC terminal adapters as chase nipples and not have suitable cable connectors where cables enter a box. ( Cables running between panels in garage). Its a great entry point for rodents and also an escape for fire into the wall cavity.

    • @ElectricProAcademy
      @ElectricProAcademy  ปีที่แล้ว

      Thanks for sharing. It's great hearing how electricians do their work and the rationale behind it.

  • @TH3mrBROWN
    @TH3mrBROWN ปีที่แล้ว

    Haha 😂the thumbnail looks so serious, can't wait to watch this!

  • @jamesyoung4633
    @jamesyoung4633 ปีที่แล้ว

    Hey Joel just a thought. Where the surge connection goes threw the stud which is plastic needs a protective plate.

    • @jamesyoung4633
      @jamesyoung4633 ปีที่แล้ว

      As well as where the feed wires between panels.

  • @jesstreloar7706
    @jesstreloar7706 ปีที่แล้ว +1

    If you love what you do, it isn't work. I would walk through the plant and see a conduit run that is a work of art, "oh yea, I did that."

  • @dandacosta8925
    @dandacosta8925 ปีที่แล้ว +4

    How do you pass inspection with PVC connectors where the SER enters in 3 different locations?? And the heat shrink is questionable also.

    • @rupe53
      @rupe53 ปีที่แล้ว +1

      they could have added a tray or junction box on top of the panel to avoid that shrink tube.

  • @cengeb
    @cengeb ปีที่แล้ว +4

    I always keep a low standard of responsibility, so i am never disappointment in myself

    • @donl1410
      @donl1410 ปีที่แล้ว +1

      🤣

  • @mathman0101
    @mathman0101 ปีที่แล้ว

    I do really think these service wire connections in the pedestal could have been cleaned up a bit. Including the service connector block. Maybe I am mistaken saw some dirt and carbon deposits. Over time the risk of deterioration grows, the potential for increased resistance and less clean power. Worse still the possibility of a damaged neutral on the service side creating dangerous conditions on the load side. I do believe that utilities could do a better job on maintenance of those pedestal connections especially as they are exposed to damaging external conditions. Just saw a pad transformer rotted out at the bottom in my area open to rodent damage and shorting. If that thing was to short out the damage and cost would be far greater than keeping up the maintenance. Utility still have not replaced the pad transformer after a month.

  • @redmatrix
    @redmatrix ปีที่แล้ว +1

    Part 1: th-cam.com/video/VHgPeK_h4Wk/w-d-xo.html
    Part 5: th-cam.com/video/KUhvUaxnkt4/w-d-xo.html Customer shows and explains Generac

  • @tristatehomesllc599
    @tristatehomesllc599 ปีที่แล้ว +1

    Are you required to have an emergency disconnect for the generator?

    • @rupe53
      @rupe53 ปีที่แล้ว

      some localities are weird like that. They want an accessible disconnect near the gen set, despite the gen already having a breaker and an external shutdown on the outside of the cabinet, which is for fire department use in emergencies. Installing a lockable switch makes me shake my head because some can be locked in either position.

    • @sungkim16
      @sungkim16 ปีที่แล้ว

      ​@@rupe53 seems silly to since there is a kill switch behind the generator for the FD

    • @rupe53
      @rupe53 ปีที่แล้ว

      @@sungkim16 .... I already said that, but I don't make the codes. I just know they exist. The code for an electrical disconnect was written a long time ago, before most companies had the other features. The kill switch for the engine is a fairly new NFPA rule. (5-6 years?) It's a "hard lockout" and requires 3 distinct keystrokes to restart the engine once the cabinet is open.

  • @Tom-wj4tr
    @Tom-wj4tr ปีที่แล้ว +1

    Utility company doesn't use torque wrenches? WTF?

    • @ferrisr
      @ferrisr ปีที่แล้ว

      I just came here to comment that too! So much sketchiness with that whole hookup the utility did...

    • @notmarcus421
      @notmarcus421 ปีที่แล้ว +3

      I've never seen one use a torque wrench just give it a few uggas

    • @DGoomba3
      @DGoomba3 ปีที่แล้ว +5

      The utility guys are their own breed. Their rules don’t apply to the ones that electricians have. In the field they just get ir done. 😂

    • @benbohannon
      @benbohannon 3 หลายเดือนก่อน

      After 29 years, their wrists get certified as a torque wrench.

  • @nhzxboi
    @nhzxboi ปีที่แล้ว +2

    This is rather lame. No doubt you'll have good voltage with no load. Very silly with ll the drama from the utility...dancing with the wires like a hero. Sort of a zero really. He'll get his due rewards at some point.

  • @Tom-wj4tr
    @Tom-wj4tr ปีที่แล้ว +3

    Would never partner with this guy. What a super painful customer.

    • @speednutsII
      @speednutsII ปีที่แล้ว +3

      Why? Joel is an electrician. This guy is an electrical engineer who wholly admits he’s done basic electrical work but is interested in learning more when it comes to something more complicated like this. Joel in exchange is learning from someone who is an engineer. It’s an exchange of professions and experience. The guy was able to talk at length and with ease about how the transfer switch works and why it’s designed the way it’s designed. Joel is a successful business owner. You don’t get that way by not trying to take every opportunity to learn from anyone you can.

    • @Tom-wj4tr
      @Tom-wj4tr ปีที่แล้ว +2

      @@speednutsII because professionals want to make money, complete the job on time and budget and get out of there. This guy over analyzes and complicates everything. I’d run away or charge him double.

    • @rupe53
      @rupe53 ปีที่แล้ว +2

      @@speednutsII ..... it also makes a more interesting video.

    • @benbohannon
      @benbohannon 3 หลายเดือนก่อน

      Agree. But there’s benefits. Better video. And great that an EE can sing your praises to all his nerd friends and refer customers.

  • @JackElectrician
    @JackElectrician ปีที่แล้ว

    First

  • @coldfinger459sub0
    @coldfinger459sub0 ปีที่แล้ว +1

    I use a Prius as a mobile HVAC owner of my company. I have a custom roof rack on my Prius. I have put 1200 pounds on the roof of the Prius. I usually only have about 4 to 500 pounds of tools and equipment and boxes on the roof of the Prius. That’s my average weight daily.
    I have a tow hitch on my Prius . The largest trailer I use is a 5’ x 9’ U-Haul trailer trailer it’s self weight about 1000 pounds and I put another thousand pounds of tools equipment and supplies in it to bring the job sites that are large and leave it there at the job site..
    My normal run around trailer is a little 4 x 4 trailer with 4 to 500 pounds of equipment and supplies on that small trailer
    All the interior in the rear has been ripped out of my Prius, and I have a flatbed for easy sliding in and out of toolboxes tools and supplies
    Underneath the flatbed board in the rear of my Prius, I have storage underneath for supplies and tools that are rarely used, but I needed when you need them on rare occasion.
    I call it my Prius work truck
    When you measure 256 V that is at the verge of the highest limit to wear many overseas, mini splits, computer boards start to receive damage from overvoltage .

    • @ElectricProAcademy
      @ElectricProAcademy  ปีที่แล้ว +1

      Hey hey! Your Prius is too cool! Can you contact us hello@electricproacademy.com re Prius Work Truck?