How to Wire a Disconnect Box for an Air Conditioner

แชร์
ฝัง
  • เผยแพร่เมื่อ 29 ส.ค. 2022
  • Hey everybody, After getting so many requests I will show you how I wire a 120v A/C Disconnect box step by step
    20 to 60-Amp-Non-Fusible-Metallic-AC-Disconnect
    amzn.to/3FaoLUR
    6 FT Liquid Line: amzn.to/3TwxmGJ
    Original Mini Split Install Video: • Master the DIY: Step-b...
    12,000 BTU Mini Split AC/Heating System with Inverter: amzn.to/3A1FKqD
    Equipment Pad for Mini Split Condensers: amzn.to/3zHym3d
    2.5" Wall Sleeve: amzn.to/3QqxfuK
    Alternatives Units:
    Senville LETO Mini Split: amzn.to/3n3x3V0
    Cooper & Hunter Mini Split: amzn.to/3Qx0r3n
    DELLA 12K Mini Split: amzn.to/3n3xxKO
    Basic Vacuum Adapter: amzn.to/3nQE4aV
    Best Adapter Tool: amzn.to/31c40E3 My Choice!
    Yellow Jacket 60278 Flaring Tool: amzn.to/3dwHpae
    Budget Flaring Kit: amzn.to/3zLHhkd
    Nylog Gasket/Thread Sealant: amzn.to/3O35oiT
    Screw Feed Tubing Cutter: amzn.to/3nQJ3Zb
    My Favorite Close Quarter Tube Cutter: amzn.to/3rpZxcg
    Vacuum Pump HVAC Kit: amzn.to/318YEcC
    PVC Decorative Line Cover Kit (one for each head): amzn.to/350IfIu
    Outdoor Mounting Bracket: amzn.to/2Fw9vpq
    2-1/2 Inch Bi-Metal Hole Saw: amzn.to/343BJS6 This A/C Unit Requires
    3-1/2 Inch Bi-Metal Hole Saw: amzn.to/3lIcpqG If needed for your A/C Unit
    DEWALT Hole Saw Kit: amzn.to/3tIjAFx
    30 Amp Fusible AC Disconnect: amzn.to/31aHN9c
    More Videos To Watch:
    Step-by-Step Guide: Installing DIY Mini Split Dual Zone | Senville | Mr Cool : • Step-by-Step Guide: In...
    How to Wire a 120v Disconnect Box for an Air Conditioner: • How to Wire a Disconne...
    Master the DIY: Step-by-Step Installation of 120v Mini Split: • Master the DIY: Step-b...
    The BEST MINI SPLIT Thermostat for Senville MrCool - The CIELO BREEZE Plus: • The BEST MINI SPLIT Th...
    #ACDisconnect #Wiringminisplit #mrcool
    IGNORE KEYWORDS:
    hvac,hvac school,air condition,how to,ac disconnect,how to install an ac disconnect,air conditioning,air conditioner,air conditioner installation,hvac basics,hvac tools,hvac installation,hvacr videos,hvac technician,hvac training videos,air conditioning system,ac disconnect tool,ac disconnect installation,ac disconnect box,ac disconnect box install,ac disconnect wiring,ac disconnect switch,hvac troubleshooting,bryan orr,Hvac school electrical,IL2BS,I Like To Build Stuff,ILikeToBuildStuff.org
  • แนวปฏิบัติและการใช้ชีวิต

ความคิดเห็น • 133

  • @hondolane1
    @hondolane1 หลายเดือนก่อน +5

    all others were showing 220. the mini unit calls for 120 and I have a 20 amp breaker at the box and you nailed it Sir.

    • @ILikeToBuildStuff
      @ILikeToBuildStuff  หลายเดือนก่อน

      Thanks for watching I appreciate it!

    • @mrdude3540
      @mrdude3540 หลายเดือนก่อน +1

      You can use a single 20 amp breaker for a 110v mini split. Black goes to breaker white and green go to bus bar

  • @kimandersonpatterson1629
    @kimandersonpatterson1629 10 หลายเดือนก่อน +3

    Well I’m glad to find this video very simple and easy to follow you uncomplicated everything all the others complicated and gave us some confidence 😂❤ thanks!

    • @ILikeToBuildStuff
      @ILikeToBuildStuff  10 หลายเดือนก่อน +1

      You're very welcome! Thanks for watching!

  • @bryanpena891
    @bryanpena891 ปีที่แล้ว +1

    Short, sweet, and straight to the point.

    • @ILikeToBuildStuff
      @ILikeToBuildStuff  ปีที่แล้ว

      I sure appreciate you joining in here Bryan, and the great comment. it means a lot to me that you would take the time to watch my video!

  • @gregbell4580
    @gregbell4580 3 หลายเดือนก่อน +2

    Thanks so much for the video. All the others talk about using 220 in a disconnect but I just wanted 110w to hook up my Mr. Cool Mini split. Thanks for making it simple

    • @ILikeToBuildStuff
      @ILikeToBuildStuff  3 หลายเดือนก่อน

      Thanks Greg for watching I appreciate it!

  • @brianc1240
    @brianc1240 ปีที่แล้ว +3

    Best video and explanation I've found so far to help install your electrical for a mini split. Thank you! I've been installing mini splits in my house to combat the high propane prices..so far this year, I've saved over 40% by switching to mini splits. Great investment and perfect for the do it yourselfers.

    • @ILikeToBuildStuff
      @ILikeToBuildStuff  ปีที่แล้ว

      I sure appreciate you joining in here Brian and the great comment it means a lot to me that you would take the time to watch my video also!

    • @elpilonvideo
      @elpilonvideo ปีที่แล้ว

      How do your system does when it is 10 f degree outside?

  • @keepmichaellong
    @keepmichaellong ปีที่แล้ว +1

    Thank you so much!! This was really helpful for me!! I'm doing two 120v mini splits and this came in really handy!!

    • @ILikeToBuildStuff
      @ILikeToBuildStuff  ปีที่แล้ว

      Hey Michael, thanks for the great comment and watching the video I sure appreciate the support.

    • @keepmichaellong
      @keepmichaellong ปีที่แล้ว

      @@ILikeToBuildStuff Thanks again for this video!! I just installed a mini-split and had to rewatch this video when installing the AC disconnect outside and low and behold, I got it working!! Keep up the good work!! Not only have you got my like, I'm subscribing to you too.

    • @ILikeToBuildStuff
      @ILikeToBuildStuff  ปีที่แล้ว

      @@keepmichaellong Thanks for the support Michael

    • @michaelruggia476
      @michaelruggia476 3 หลายเดือนก่อน

      Couldn't you just wire nut the 2 whites together?

  • @sammyking9407
    @sammyking9407 หลายเดือนก่อน

    Extremely well done. Clear and concise. Thank you sir!

    • @ILikeToBuildStuff
      @ILikeToBuildStuff  หลายเดือนก่อน +1

      Thanks for watching I appreciate it!

  • @theghostwizard6745
    @theghostwizard6745 2 หลายเดือนก่อน +1

    Great job. Right to the point.

  • @bertpainter8385
    @bertpainter8385 9 หลายเดือนก่อน +1

    Appreciate this. Asked my retired electrician buddy by text earlier today by sending a picture of someone tying the whites together and not using the terminals to see if that was code, but hadn't heard back from him yet. But I rather go with the terminals. Still not sure if it's ok by code to tie the whites together though. Like to always go by code just in case with everything.

    • @ILikeToBuildStuff
      @ILikeToBuildStuff  9 หลายเดือนก่อน

      Here we have to terminal on a disconnect

  • @SHRI_the_DIY_Warrior
    @SHRI_the_DIY_Warrior ปีที่แล้ว

    Good job budd 😊thank you 😊

  • @peppi7777
    @peppi7777 28 วันที่ผ่านมา

    As for the surge protector to install on the 120v disconnect box its pretty simple as well. Your surge protectors work for both 120v and 220v . The surge protector comes with 3 wires : 2 blacks and 1 white. The white is not the neutral but it is the ground. So tie it to the ground nut in the box. The other 2 wires ( black ), for the 120 wiring ,you tie the 2 blacks together as one wire and put it on the one the load side of the condenser wire hot black. Thats it. For 220 you put each black on the load sides. And cut the chord as short as it requires without bends. Hipe that helps a bit and gipe not confusing. Based in this video you put the 2 black wires of the surge protector together on the load side. And the ac coming in hot black on the as he shows. The neutral line in can be tied together with a nut or as he shows in this video. Every city has their own codes. Ask the inspector if you need to and wire it that way. But i shut breaker off from inside panel when i do service and the disconnect box as well.

  • @hondolane1
    @hondolane1 หลายเดือนก่อน

    super. very simple and direct

  • @emmettgarcia1062
    @emmettgarcia1062 11 หลายเดือนก่อน +1

    When you disconnect with the neutral on the lug, it actually leaves voltage resting on the neural on the load side, creating a potential of difference. Neutrals always need to remain continuous back to the source in order to prevent a shock hazard. I would recommend using the wire nut method or what I’ve done in the past is use a 20a single pole switch in a bell box with a weather proof red handle cover.

    • @ILikeToBuildStuff
      @ILikeToBuildStuff  11 หลายเดือนก่อน

      Hello Emmett, Thanks for sharing! We all appreciate the comments and for watching.

  • @nathanmanley5549
    @nathanmanley5549 5 หลายเดือนก่อน

    Thank you!

    • @ILikeToBuildStuff
      @ILikeToBuildStuff  5 หลายเดือนก่อน

      You're very welcome! Thanks for watching.

  • @warnee81
    @warnee81 11 วันที่ผ่านมา

    thank you so much . this was what i wanted to know.

  • @romelmejia3106
    @romelmejia3106 10 หลายเดือนก่อน

    Thank you for you video

    • @ILikeToBuildStuff
      @ILikeToBuildStuff  10 หลายเดือนก่อน

      So nice of you, thank you for watching!

  • @SuperOpinion8ed
    @SuperOpinion8ed 8 หลายเดือนก่อน +1

    I won’t comment on code because I’m not an electrician or inspector. But in terms of physics, this works. In terms of good practices, do it per code (or as right as you can). Sometimes it’s not about you but the guy behind you. Put the “line” wires to the panel. Put the “load” wires to the ac unit.
    You could wire a cat 5 terminal any way you want and as long as both ends match it’ll work and the tester will say it’s good. But the day there’s an issue the tech is going to replace one end and the whole house of cards come crashing down.
    So, again, do it as right as you can. You can use a white wire for hot too, but at least wrap it in red or black tape where you can see it. Same concept. Physics versus good practices.

  • @bayoudreams395
    @bayoudreams395 9 หลายเดือนก่อน

    I was wondering if you have a video (or can do one) on adding a surge protector to the 120V ac? I can't find any videos on this and just thought it would be helpful to others and a good addition to your channel. Much appreciated for this video as I connected a 'fused' disconnect using your information. I had a fuseable box so used it, otherwise I would have saved money by buying a non-fuseable disconnect.

    • @ILikeToBuildStuff
      @ILikeToBuildStuff  9 หลายเดือนก่อน +1

      Great idea, I will look into that. Thanks for the input!

  • @wanderlostNW
    @wanderlostNW ปีที่แล้ว +1

    Regard less it’s hot or neutral, as long as you put your AC lines to the Load and source lines to the Line, will be fine, correct?

  • @ChristianKauffman
    @ChristianKauffman 2 หลายเดือนก่อน

    Super helpful! One question: my electrician wired 12 gauge to my disconnect. Can I use a 10 gauge AC whip with that?

    • @ILikeToBuildStuff
      @ILikeToBuildStuff  2 หลายเดือนก่อน +1

      Sure, you just can't go the other way to smaller wires.

  • @joonyaboy
    @joonyaboy 11 หลายเดือนก่อน

    Thanks I needed this. The instructions were not clear on the box

    • @ILikeToBuildStuff
      @ILikeToBuildStuff  11 หลายเดือนก่อน

      Sorry I was not clear about this and will try better next time.

  • @HillOrStream
    @HillOrStream 11 หลายเดือนก่อน +2

    The inside two connections are more insulated and should recieve the source wires. The two outer bare connections are for the outgoing lines.

    • @ILikeToBuildStuff
      @ILikeToBuildStuff  11 หลายเดือนก่อน

      Thanks for watching I appreciate it!

    • @dperreno
      @dperreno 20 วันที่ผ่านมา

      Agree. Inside connectors are for the line (to the panel), outside connectors are for the load (ac unit).

  • @falconthree3815
    @falconthree3815 2 หลายเดือนก่อน

    Hi Jim, question can I mount a gfi outlet on the disconnect /120v sharing the same power source to the a/c ?

    • @ILikeToBuildStuff
      @ILikeToBuildStuff  2 หลายเดือนก่อน +1

      No, the a/c unit is known for tripping GFI and as per code I am almost certain everywhere in USA it's a dedicated line with only the disconnect allowed.

  • @extreme696969
    @extreme696969 2 หลายเดือนก่อน

    Hi great video, my question is..the system uses a 20amp braker, so can i use a 30 or 60 amp disconnect box? Thanks

    • @ILikeToBuildStuff
      @ILikeToBuildStuff  2 หลายเดือนก่อน +1

      Yes you can! and thanks for watching

  • @travisschafer4158
    @travisschafer4158 ปีที่แล้ว

    Is it ok to hook up two mini splits (assuming amperage loads are ok) to a single disconnect? I take it that I would splice them to the same outgoing nuts? Thanks

    • @ILikeToBuildStuff
      @ILikeToBuildStuff  ปีที่แล้ว

      As per code NO, you must have a disconnect for each unit

  • @joebarnes3368
    @joebarnes3368 ปีที่แล้ว

    I see you have a condenser like the one I purchased, have you done a video installation of this unit with air handler

    • @ILikeToBuildStuff
      @ILikeToBuildStuff  ปีที่แล้ว

      Hey Joe, Yes I have two videos one on a single unit for shop th-cam.com/video/07SB6aIJfPU/w-d-xo.html and the other dual system video th-cam.com/video/1WHYPfq6MGc/w-d-xo.html
      Thanks for visiting the channel and watching, I appreciate it!

  • @ShootieMcShoot
    @ShootieMcShoot 14 วันที่ผ่านมา

    Can I do the same process if I want to add a 120 outlet to the disconnect box?

    • @ILikeToBuildStuff
      @ILikeToBuildStuff  13 วันที่ผ่านมา

      It should not have a receptical in the line, unit to disconnect then disconnect to dedicated 20amp breaker homerun to electrical box

  • @darkreelaction
    @darkreelaction 2 หลายเดือนก่อน

    Did you use 12-2 to the disconnect and the outside unit? Or did you use 10 going from the disconnect to the outside unit?

    • @ILikeToBuildStuff
      @ILikeToBuildStuff  2 หลายเดือนก่อน

      Yes, on a 20amp circuit I ran a dedicated 12-2. Thanks for watching!

  • @chrisfields1333
    @chrisfields1333 5 หลายเดือนก่อน

    I have a older trane unit and it has 2 black wires. Not sure why. I am hesitant to hook it up because I am not sure what the extra goes to. (Line or load) If you have any ideas please let me know 👍

    • @ILikeToBuildStuff
      @ILikeToBuildStuff  5 หลายเดือนก่อน

      Well not knowing or seeing what you have I would contact Trane and ask. If it's a 240v most have a red and black for L1 L2 but like i said without seeing it I don't want to give you bad advice.

  • @giovannipaul007
    @giovannipaul007 ปีที่แล้ว

    Is it the same hookup if my minisplit unit is 115v with a 15amp breaker at the panel? Do you need a ac disconnect that's rated at 120/240 or any disconnect that says 240?

    • @ILikeToBuildStuff
      @ILikeToBuildStuff  ปีที่แล้ว

      Hi, this is for the 120 with a 20 amp breaker but no you only need a 120 disconnect for a 120 mini split but if it's 240 then the disconnect needs to be listed as such for code

    • @giovannipaul007
      @giovannipaul007 ปีที่แล้ว

      I don't see just a 120 disconnect anywhere it's usually showing 120/240 in the listings. I am trying to figure out what I need for my setup

    • @ILikeToBuildStuff
      @ILikeToBuildStuff  ปีที่แล้ว +1

      @@giovannipaul007 No problem here ya go amzn.to/3FaoLUR

  • @taniksambo1969
    @taniksambo1969 ปีที่แล้ว

    Is it possible to add an outlet from a quick disconnect line?

  • @ryandodson2786
    @ryandodson2786 ปีที่แล้ว

    Aren't the line lugs in the middle and the load lugs on the two outer 2 terminals?

    • @ILikeToBuildStuff
      @ILikeToBuildStuff  ปีที่แล้ว

      Hi Ryan, you are correct but like I said in the video that it didn't matter as the black or white block just makes the connection between the white wires on one side and the black wires on the other in this type of box. Good eye Ryan! Thanks for watching and joining in.

  • @phillamoore157
    @phillamoore157 หลายเดือนก่อน

    This was a GREAT video. The irony is that "certified" electricians either can't, or aren't about to explain anything. I think I'm over-thinking this, but this part doesn't confuse me as much as how this leads back to the main breaker panel. You see a lot of videos on this part of it. I need to run a new breaker from our main box across the house somewhere accessible to our 2nd floor master bedroom for a mini-split. And, I need to do it in a way that doesn't get me castrated because it looks like a huge eye-sore. Certified electricians want an insulting amount of money to do this, and short of running the wire, it doesn't seem like it's that hard of a job (compared to the mini-split install itself). Any advice, or link you can give on the 1st part of this...i.e. main fuse box to the shut-off?

    • @ILikeToBuildStuff
      @ILikeToBuildStuff  หลายเดือนก่อน

      I would say first check to see if your panel has any dedicated electrical line running in the area where you need it but isn't in use. I have seen that so many times. But if you need to run your own line it's not usually a problem if you have attic access, you can hide the line in the attic and drop it out under the roof eve. But you are correct running the line and connecting it is not a big deal.

    • @phillamoore157
      @phillamoore157 หลายเดือนก่อน

      @@ILikeToBuildStuff Thank you! I’m hoping, like you said there’s a line running to that side of the house. If I have to use the attic, I’ll have to wait till winter. It’s 120 degree’s up there literally. The heatwave/drought in Fl right now is beyond brutal. Fortunately, it looks like the electrical part of this should be fairly straight forward. Thanks again for the reply.

  • @therickster1989
    @therickster1989 8 หลายเดือนก่อน

    My whip uses green,red, and black conductors opposed to your green,white and black conductors. Would I just use the red in the same configuration as your white into the disconnect?

    • @ILikeToBuildStuff
      @ILikeToBuildStuff  8 หลายเดือนก่อน +1

      Hi and welcome, Yes but an inspector may not approve of the color change. But if they do just replace the whip wire to natural white. I have been able to pass by wrapping the red with white tape. Hope this helps and thanks for watching!

    • @therickster1989
      @therickster1989 8 หลายเดือนก่อน +1

      Thank you

  • @victorgutierrez5826
    @victorgutierrez5826 ปีที่แล้ว

    can you explain me..why connect a 60 amp box to the A/C and not a 30 Amps box? if isn't 220 volts?

    • @ILikeToBuildStuff
      @ILikeToBuildStuff  ปีที่แล้ว

      It's mainly the box that can handle up to 60amps but it's the breaker that will control the 30amp shutoff

  • @hippo-potamus
    @hippo-potamus ปีที่แล้ว +2

    I hate pullout disconnects. I want to use the Square D 60 amp 240v breaker type disconnect, here is my idea please let me know what you think about it: Run hot wire from main panel to hot lug of disconnect box. Connect hot wire from ac to breaker. Connect both grounds to disconnect box ground bar. ADD an isolated neutral bar to the disconnect box and run both neutrals to that (seems better than just wire nut the neutrals together). If you know of a 120v single pole non fuse disconnect that is not the pullout type I would really appreciate a link to it. Thank you for your reply. Cheers

    • @ILikeToBuildStuff
      @ILikeToBuildStuff  ปีที่แล้ว

      Hello, check out amzn.to/3FUaufp in my opinion this would work for 240v and 120v just choose the correct amperage breaker for the application. If you are looking to pass code the hot & neutral wires would all need to be terminated at the disconnect which I don't recommend any other method

    • @hippo-potamus
      @hippo-potamus ปีที่แล้ว +1

      @@ILikeToBuildStuff I'll look at that one. Yea most of the switches I've been looking at while being shut off are not true disconnects as the neutrals remain bonded to the circuit. I dont like working on equipment even if the hots are disconnected if the neutrals are still active. While I don't have any circuits that share neutral runs I just feel better if the disconnect switch disconnects both the hot and neutral lines entirely which is why I was hesitating about turning the breaker disconnect into a switch disconnect. Thanks for your input. Edit: I think the Siemens LNF221R lever disconnect is what I need. Each pole side is isolated so I can run the hot to one side and the neutral to the other pole. As such the lever would disconnect both lines simultaneously.

  • @ILikeToBuildStuff
    @ILikeToBuildStuff  ปีที่แล้ว

    20 to 60-Amp-Non-Fusible-Metallic-AC-Disconnect
    amzn.to/3FaoLUR
    Liquid Line
    amzn.to/3gH9baa
    Original Mini Split Install Video: th-cam.com/video/07SB6aIJfPU/w-d-xo.html
    12,000 BTU Mini Split AC/Heating System with Inverter: amzn.to/3A1FKqD
    Equipment Pad for Mini Split Condensers: amzn.to/3zHym3d
    2.5" Wall Sleeve: amzn.to/3QqxfuK
    Alternatives Units:
    Senville LETO Mini Split: amzn.to/3n3x3V0
    Cooper & Hunter Mini Split: amzn.to/3Qx0r3n
    DELLA 12K Mini Split: amzn.to/3n3xxKO
    Basic Vacuum Adapter: amzn.to/3nQE4aV
    Best Adapter Tool: amzn.to/31c40E3 My Choice!
    Yellow Jacket 60278 Flaring Tool: amzn.to/3dwHpae
    Budget Flaring Kit: amzn.to/3zLHhkd
    Nylog Gasket/Thread Sealant: amzn.to/3O35oiT
    Screw Feed Tubing Cutter: amzn.to/3nQJ3Zb
    My Favorite Close Quarter Tube Cutter: amzn.to/3rpZxcg
    Vacuum Pump HVAC Kit: amzn.to/318YEcC
    PVC Decorative Line Cover Kit (one for each head): amzn.to/350IfIu
    Outdoor Mounting Bracket: amzn.to/2Fw9vpq
    2-1/2 Inch Bi-Metal Hole Saw: amzn.to/343BJS6 This A/C Unit Requires
    3-1/2 Inch Bi-Metal Hole Saw: amzn.to/3lIcpqG If needed for your A/C Unit
    DEWALT Hole Saw Kit: amzn.to/3tIjAFx
    30 Amp Fusible AC Disconnect: amzn.to/31aHN9c

  • @ernie5187
    @ernie5187 ปีที่แล้ว

    I will be using the wiring from my kitchen base board heater because we dont use it. It uses 2 20amp breakers in my main panel
    So wouldn't I just need to use 1 of the 20amp breakers and 1 ser of wires from that breaker for my disconnect? Thanks!

    • @ILikeToBuildStuff
      @ILikeToBuildStuff  ปีที่แล้ว

      Hi Ernie, Yes as long as that is what your unit requires. I say that because another viewer ask that and I said yes but his was a 220v

  • @Stuntifed
    @Stuntifed ปีที่แล้ว

    I can only find a electrical whip with 4 wires. The power coming from my panel will be done with 12/2 on a 20A circuit to the non fused disconnect. Where do I put the extra wires from the whip!!?

    • @ILikeToBuildStuff
      @ILikeToBuildStuff  ปีที่แล้ว

      Hi Mathew, you should be able to pull the non used wire out no problem

    • @___asd159gh43
      @___asd159gh43 ปีที่แล้ว

      ​@@ILikeToBuildStuff does it matter if im using a 30A or 60A box if were relying on the breaker box for that, or is there probably a local code or something that will tell me which one to use?

    • @ILikeToBuildStuff
      @ILikeToBuildStuff  ปีที่แล้ว

      @@___asd159gh43 Most A/C disconnects I've seen are 60 amp which is standard and most of the time less expensive. There's nothing wrong with using a 60 amp disconnect on a 30 amp unit as long as the circuit itself is on the proper size breaker.

    • @___asd159gh43
      @___asd159gh43 ปีที่แล้ว

      @I Like To Build Stuff ok, cool. Cause all my local big box store had was a 30A and im adding a MrCool 115v which is supposed to run around 10A. But definitely all makes sense. Thanks for your help!

    • @ILikeToBuildStuff
      @ILikeToBuildStuff  ปีที่แล้ว

      @@___asd159gh43 You Bet!

  • @bstebbins314
    @bstebbins314 ปีที่แล้ว

    Can you use a 220 disconnect and wire the same way? The 120 is hard to find.

    • @ILikeToBuildStuff
      @ILikeToBuildStuff  ปีที่แล้ว

      Here ya go Brian amzn.to/3FaoLUR

    • @NIPictures
      @NIPictures 11 หลายเดือนก่อน

      @@ILikeToBuildStuffgreat video, thanks! Btw the Halex HNF60R is 240v rated and I will also install it to my 120v mini split.

  • @folsomatgranitebay5215
    @folsomatgranitebay5215 4 หลายเดือนก่อน

    Should phase tape/re identify line neutral that is also hot.

    • @ILikeToBuildStuff
      @ILikeToBuildStuff  4 หลายเดือนก่อน

      You can but I have never had a problem with inspectors but it is a good point, thanks for commenting we appreciate it.

    • @jefflinsk8032
      @jefflinsk8032 2 หลายเดือนก่อน

      How is the neutral hot? It's only a 120 circuit. The disconnect has 2 sides to accommodate 240 but it's effectively just an on -off switch. Right?

  • @johnrutledge9757
    @johnrutledge9757 5 หลายเดือนก่อน

    What is the hight requirement for the outdoor disconnect

    • @ILikeToBuildStuff
      @ILikeToBuildStuff  5 หลายเดือนก่อน

      Hi John, in my area is 48 inches but I am to understand this varies in other places. I have never seen or placed one lower than 36" myself though

  • @anthonycarroll7222
    @anthonycarroll7222 ปีที่แล้ว +1

    Are you using 12/2 wire?

    • @ILikeToBuildStuff
      @ILikeToBuildStuff  ปีที่แล้ว +2

      Hi Anthony, Yes on the 110v units with a short run I do.

  • @EdwardVanVino
    @EdwardVanVino ปีที่แล้ว +1

    Is it possible to use the wiring from an outlet but keep the outlet? Im so confused at why nobody has explained this

    • @Constantsorrow512
      @Constantsorrow512 ปีที่แล้ว +1

      Yes it's possible, safe as well, but won't pass code anywhere in the US.

    • @EdwardVanVino
      @EdwardVanVino ปีที่แล้ว +2

      @@Constantsorrow512 ah ok. I’m in an odd situation in an HOA where the fuse box is on the outside of another unit so I can’t just run lines through their place. Need to swap for a dedicated breaker to something else.

    • @ILikeToBuildStuff
      @ILikeToBuildStuff  ปีที่แล้ว

      What Randy Said!

  • @elpilonvideo
    @elpilonvideo ปีที่แล้ว

    You have to start in your house electric box first then to that box outside then to your mini split

    • @ILikeToBuildStuff
      @ILikeToBuildStuff  ปีที่แล้ว

      Yes, you would need to make a home run to this box.

  • @maryhyarborough4071
    @maryhyarborough4071 18 วันที่ผ่านมา

    Where does the red wire go? Also, my disconnect has two extra places that your box doesn't have. I have to assume those would be for fused connections. Nonetheless, I removed those and still don't know where the red wire goes (from the whip). The bozo local yokel I had install my ductless simply used the disconnect as a junction box, which is how my motherboard got fried. It's how all the ac guys here do it, which is why I've become a DYIer out of necessity. So, I'm trying to fix this and do things properly. Meanwhile, the various how-to install disconnect videos I've watched do not discuss the red wire, and there are conflicts on whether I treat the load white as hot. I'm way confused. A little help?

    • @ILikeToBuildStuff
      @ILikeToBuildStuff  18 วันที่ผ่านมา

      I am going to assume that your unit is 120v and not 240v in which case the red wire would be for the 240v so it sounds like the red wire is not hot but an extra inside the whip, you should verify that it is a unused wire and that no current .

  • @Mindcoach1on1
    @Mindcoach1on1 ปีที่แล้ว

    I’m curious if the circuit is only 20 A why did you use a 60 amp

    • @ILikeToBuildStuff
      @ILikeToBuildStuff  ปีที่แล้ว

      Good morning, this box was $1 more and can be used up to 60 amps so if I ever want to change out for a bigger split I can. The disconnect has nothing to do 20 or 60 amp in the breaker box you need to put the right amp breaker according to each unit unless the disconnect has a breaker itself.

    • @ryandodson2786
      @ryandodson2786 ปีที่แล้ว

      It will go up to 60amp

    • @ILikeToBuildStuff
      @ILikeToBuildStuff  ปีที่แล้ว

      @@ryandodson2786 Yes this box is rated up to 60 amp but it is limited to the breaker in the main feed.

  • @yolandawebster7808
    @yolandawebster7808 ปีที่แล้ว

    Wish it was a closer pic as on my phone I can't tell what you are doing.

    • @ILikeToBuildStuff
      @ILikeToBuildStuff  ปีที่แล้ว +1

      Thanks for watching I appreciate it! I will try to do better.

    • @yolandawebster7808
      @yolandawebster7808 ปีที่แล้ว

      @@ILikeToBuildStuff Watched on my computer and MUCH better. Thanks for your info!

    • @ILikeToBuildStuff
      @ILikeToBuildStuff  ปีที่แล้ว

      @@yolandawebster7808 Thank you

  • @yon_s0l011
    @yon_s0l011 ปีที่แล้ว +1

    120 single phase doesn't matter where u put them? How did u wire in main panel?

    • @ILikeToBuildStuff
      @ILikeToBuildStuff  ปีที่แล้ว

      correct it just makes the connection when you insert the bar and as far as the main panel was a 20 amp single throw with the black hot wire to the breaker the white wire to the neutral bar and ground to ground bar.

    • @elpilonvideo
      @elpilonvideo ปีที่แล้ว +1

      That’s the million dollars question 😂

    • @directoppositeent
      @directoppositeent ปีที่แล้ว

      Lol no one ever show the main box, just disconnect box

  • @YanLevesque
    @YanLevesque ปีที่แล้ว

    You don't put a fitting where your wire get in the box, so no water goes in and the wire is secured?

    • @ILikeToBuildStuff
      @ILikeToBuildStuff  ปีที่แล้ว +1

      You are correct, I did go back and use a sealer there and have had no problems. Good eye Yan!

  • @Weasel_NM575
    @Weasel_NM575 ปีที่แล้ว +1

    You keep saying a 20 amp breaker but when you’re hooking both lines to a line terminal then it’s no longer a neutral correct?! So that 20 amp breaker to talk about is it a 2 pole 20 amp breaker?!

    • @ILikeToBuildStuff
      @ILikeToBuildStuff  ปีที่แล้ว

      You can use a 2 pole but with this disconnect it just stops power to unit for servicing and code. A single pole works fine for this application.

  • @cookinwithchris86
    @cookinwithchris86 7 หลายเดือนก่อน

    No k es showing how u wire it to your breaker box

    • @ILikeToBuildStuff
      @ILikeToBuildStuff  7 หลายเดือนก่อน

      Well that's because if someone is not comfortable installing a breaker in a service panel they may want to hire someone who is, I say this for safety concerns and why I don't show it. I know you watch an entire video so you don't miss how to do the job but there are thousands that skip around a video assuming they are getting all the information they need and unfortunately can cause harm not only to them but to others.

  • @AngelPerez-nw5cd
    @AngelPerez-nw5cd ปีที่แล้ว

    That’s 240v and there’s no neutral his using the white as the second hot because his using a double pole breaker.

    • @ILikeToBuildStuff
      @ILikeToBuildStuff  ปีที่แล้ว

      Well this was 120 and just an A/C disconnect with a homerun to a 20 amp breaker single pole

  • @richardm.9821
    @richardm.9821 ปีที่แล้ว

    You need to change your title to denote this is a Mini-Split and NOT a common A/C unit. There IS a difference.

    • @ILikeToBuildStuff
      @ILikeToBuildStuff  ปีที่แล้ว

      Thanks for the input Richard I appreciate that.

  • @avagates2039
    @avagates2039 ปีที่แล้ว

    It's all Chinese to me. 😔