How to replace a sprinkler manifold & valves

แชร์
ฝัง
  • เผยแพร่เมื่อ 23 ก.ย. 2024

ความคิดเห็น • 213

  • @JBinCalifornia
    @JBinCalifornia 8 ปีที่แล้ว +1

    We're redoing our entire school garden, and will have 16 zones + all hooked up to a wi-fi controller (Rachio Iro)... I've done several valves to replace at home; our upcoming project mimics your video w/ multiple valves + so, thanks... this video is very helpful to help visualize the steps, spacing between valve boxes, etc. Thx!

    • @Iscaper
      @Iscaper  8 ปีที่แล้ว

      +JBinCalifornia
      Thanks for watching.

  • @farmerbob339
    @farmerbob339 5 ปีที่แล้ว

    Nicely done. Now I am no longer discouraged from doing systems from scratch. Only wish they had the valves with Unions on them I did my last overhaul. I ended up putting regular 1" unions inline. AND Drain Valves!! I had them all over so once pressure was lost every thing would drain. Grandpa took them all out. I have had to do some major repairs because of this. Will fix it soon.

  • @spelunkerd
    @spelunkerd 12 ปีที่แล้ว +1

    Thanks Kerry. When I set my multimeter to measure AC voltage I measured 25V for voltage drop both at the solenoid (while running) and at the controller -- dumb mistake for me to think it was DC. In my community a new solenoid is $14 and a new valve is $57 so I just replaced the solenoid. My old solenoid had high resistance that bounced around, suggesting a bad internal wire. The new solenoid resistance was 24 ohms, the bad solenoid was 30-90 ohms. Success!
    Thanks for your advice.
    Dave

  • @oceansidehigh
    @oceansidehigh 10 ปีที่แล้ว +1

    We're fixing our sprinkler system too, and this video (along with your other ones) has been incredibly helpful. Thanks so much for posting!

    • @Iscaper
      @Iscaper  10 ปีที่แล้ว +1

      Thanks, I appreciate the comments.

  • @robertstone5476
    @robertstone5476 9 ปีที่แล้ว

    Very educational and well explained. I thought the only step missing was your checking for leaks after everything was replaced! I wish all valve had unions; that would make life a whole lot easier.

    • @Iscaper
      @Iscaper  9 ปีที่แล้ว

      Robert Stone
      I did check for leaks but didn't show it in the video. Unfortunately Rain Bird discontinued the valve with unions shown in the video. Not sure why they did it but they did.

  • @van_dutch
    @van_dutch 4 หลายเดือนก่อน

    This is incredible work, def motivating me to take on my 4 valve system. The job in this video would be about 20 trips to Home Depot for me.

    • @Iscaper
      @Iscaper  4 หลายเดือนก่อน

      Rain Bird has discontinued the union valves shown in the video. I've started using Action manifolds instead. Here's a link to a video using an Action manifold and Rain Bird 100DVF sprinkler valves: th-cam.com/video/WpetroPws10/w-d-xo.html

  • @Iscaper
    @Iscaper  11 ปีที่แล้ว +1

    Very kind, thanks for taking the time to leave a comment.

  • @spelunkerd
    @spelunkerd 12 ปีที่แล้ว

    Yes, I've heard the same thing from others, who describe the whole valve costing just a little more than the solenoid. But up here in Canada there are strange differences, partly related to duty and additional transportation fees. The valve is an irritrol 2711 APR but the solenoid is made in Mexico so it should be duty free. Mail order is often a problem here because of additional customs and shipping fees. Overall I'm glad it is fixed, and it's fun to understand how it all works. Thanks again.

  • @progers5019
    @progers5019 9 ปีที่แล้ว +3

    Great jobs, I really enjoyed watching you work through that. What a difference. Easy to listen to.

    • @Iscaper
      @Iscaper  9 ปีที่แล้ว

      Irvin Rogers
      Thanks Irvin.

  • @CostaMesaPhotography
    @CostaMesaPhotography 9 ปีที่แล้ว

    Very nicely done...if you're not already teaching, you should consider it--you're good.

    • @Iscaper
      @Iscaper  9 ปีที่แล้ว

      CostaMesaPhotography
      Thanks, I appreciate the feedback.

  • @joannalayne8688
    @joannalayne8688 6 ปีที่แล้ว

    Thanks for your video...the rubber mallet was just the trick when I was replacing my manifold....also instead of dish soap, I used hair dryer for about 60 seconds on my poly tubing and connectors slipped in very easily.

  • @alextoufanpur2629
    @alextoufanpur2629 9 ปีที่แล้ว +13

    So patiently explained. Thank you friend!

    • @Iscaper
      @Iscaper  9 ปีที่แล้ว

      Alex Toufanpur
      Thanks Alex for watching.

    • @JoseMichell
      @JoseMichell 9 ปีที่แล้ว

      iScaper1
      Can you tell me where to purchase Dura parts to build the sprinkler manifold? I broke one of the connectors and I'm unable to find a store in Regina. Since you are wearing a Rider's hat I assume u r from Sk. Thanks.

    • @Iscaper
      @Iscaper  9 ปีที่แล้ว

      Jose Michell
      You can buy them online here: www.sprinklerwarehouse.com/Standard-Valve-Manifold-Parts-s/456.htm

    • @crzy11000
      @crzy11000 9 ปีที่แล้ว

      Jose Michell You can get from consolidated turf in Saskatoon

    • @JoseMichell
      @JoseMichell 9 ปีที่แล้ว

      Thank you for the information.

  • @SDRWeddingsEvents-hh5ld
    @SDRWeddingsEvents-hh5ld 5 หลายเดือนก่อน

    You have given me the confidence to attempt this. Thank you

    • @Iscaper
      @Iscaper  5 หลายเดือนก่อน

      Good luck!

  • @Iscaper
    @Iscaper  11 ปีที่แล้ว

    If you're referring to the fitting between the 2 pre-built manifolds, it is not a coupling it is a 1"x1"x1/2" tee (SxSxT) that has an automatic drain threaded into it.

  • @Iscaper
    @Iscaper  12 ปีที่แล้ว

    Start by turning the stop & waste valve on, make sure it is completely on. Then look in the stand pipe that covers the valve. Notice if there is water filling the pipe. You could have a leak on the downstream side of the stop & waste valve. If you don't notice anything there then check all of your sprinkler valves for leaks. If the flow dial is spinning slowly, it can be difficult to isolate the leak. The most likely culprits are the sprinkler valves or your stop & waste valve.

  • @DazedNConfuzed58
    @DazedNConfuzed58 10 ปีที่แล้ว

    I am having problems with my system & this video was very helpful. Thank you! In fact my valves are the same ones here.

    • @Iscaper
      @Iscaper  10 ปีที่แล้ว

      Thanks Paully.

  • @spelunkerd
    @spelunkerd 12 ปีที่แล้ว

    Hi Kerry. I'm wondering what the normal spec for a typical solenoid valve should be for voltage drop and amp draw. If the solenoid is removed, what is the (DC?) voltage diff to ground at the device? I've got what I think is a bad solenoid but it has been hard to prove since it does work with a 9V battery when under no load. I've swapped it for other solenoids, and also I swapped the wiring with a known good valve and both tests say the solenoid is bad. Connections are clean.

  • @Iscaper
    @Iscaper  11 ปีที่แล้ว

    Thanks for watching and for the feedback.

  • @Iscaper
    @Iscaper  12 ปีที่แล้ว

    Hi Dave.
    I've done the multi-tester on the wrong setting also. I'm surprised there was that much difference in the solenoid and valve cost. Usually it's only a few dollars. What kind of valves do you have?
    Glad you solved your problem. 95% of valve trouble I run into is the solenoid.
    KT

  • @JoseRivera-hl6ve
    @JoseRivera-hl6ve 9 ปีที่แล้ว

    Keep making those video! Thank you for your time and effort in making this project so easy to do.

    • @Iscaper
      @Iscaper  9 ปีที่แล้ว

      Thanks Jose, I appreciate the feedback.

  • @Iscaper
    @Iscaper  12 ปีที่แล้ว

    Interesting, I can buy a Rain Bird DV valve for $11, and if I just want the solenoid it is $10.
    What part of Canada do you live in? We just went to Vancouver Island and Vancouver. What a beautiful country!

    • @tracyr5594
      @tracyr5594 6 ปีที่แล้ว

      yes, is cheaper to buy new valves than valve parts...

  • @Iscaper
    @Iscaper  12 ปีที่แล้ว

    Test your voltage from the timer. If you have the 28-29 volts I talked about earlier, everything is good to the valve. If the valve won't open and close properly your problem has to be the solenoid.
    Buy a new valve and replace the top half of the old valve with the top half of the new valve. I suggest this because solenoids often cost as much or more than a complete valve.
    Let me know how this works.

  • @toekneemoment
    @toekneemoment 3 ปีที่แล้ว

    This video is so well done. Thank you for taking your time to put this up on youtube!

    • @Iscaper
      @Iscaper  3 ปีที่แล้ว

      Thanks, I appreciate the feedback.

  • @josephperrone1979
    @josephperrone1979 6 ปีที่แล้ว +1

    The Bob Ross of irrigation. Good job

  • @Iscaper
    @Iscaper  11 ปีที่แล้ว

    Depends on what your system piping is. If your supply line piping to the valves is 1.25" or 1.5" I would install 1.5" valves. If your supply line is 1" you would be ok installing 1" valves. You don't want to reduce the available flow in gpm (gallons per minute) through the valves to the sprinkler system.

  • @Iscaper
    @Iscaper  11 ปีที่แล้ว

    Where I live the backflow preventer has to be installed before the first set of sprinkler valves. You are correct, these aren't anti-siphon valves.

  • @Iscaper
    @Iscaper  11 ปีที่แล้ว +4

    I bought them from my Rain Bird distributor. Unfortunately Rain Bird discontinued the valve. It was my favorite valve. You can still get the DVF without the unions.

  • @29nettels
    @29nettels 12 ปีที่แล้ว

    Question for you sir and thank you for the videos. My water meter has a little spinner on it and it's slowly turning. When I shutoff the water to the sprinkler system, that little spinner stops, so I think the manifold is leaking. When I take off the cover to expose the zone valves, there is stagnant water in there. Not a high amount of water but maybe half full. This is probably a leak before the valves since I haven't used the sprinkler system in awhile?

  • @johnmariano47
    @johnmariano47 7 ปีที่แล้ว

    Thanks and Well done! ' Subscribed too. The 100DFVuu may be obsolete at this time as I cannot find them online. Are the unions themselves detachable? Thanks.

  • @roberts.9599
    @roberts.9599 8 ปีที่แล้ว +4

    Just a suggestion, but you may try Oetiker clamps vs. screw clamps. Also, I tend to refrain from using automatic drains aka King drains. I've found that root intrusion and the amount of water they waste isn't worth the benefits.

  • @heroknaderi
    @heroknaderi 3 ปีที่แล้ว +1

    I enjoyed the video. I also have 9 zones at my home and still working ok the only thing I am curious about is how to find hidden valves because I could never find them my system was installed in the 1980s and I believe the installer directly buried the valves and didn’t use valve boxes. I always like to know where they are for future maintenance. Very helpful video.😁👍

    • @Iscaper
      @Iscaper  3 ปีที่แล้ว +1

      You may have to rent a line locator to find the valves.

  • @cristobalpacheco4202
    @cristobalpacheco4202 5 ปีที่แล้ว

    Did your 12 wire timer wire reach to all the different valves or did you have to add wire extensions? Thanks

    • @Iscaper
      @Iscaper  5 ปีที่แล้ว

      I cut short lengths of timer wire and looped them up where the valve boxes would be.

    • @cristobalpacheco4202
      @cristobalpacheco4202 5 ปีที่แล้ว

      Thanks, I really enjoy this type of video

  • @sphudson
    @sphudson 12 ปีที่แล้ว

    Can you please tell me the name/part# of those valves and where I can purchase them? I believe you said RainBird. Thanks in advance.

  • @omutakaeddie
    @omutakaeddie 9 ปีที่แล้ว

    Every body should learn how to use this type of irrigation.

  • @therealandrewcano
    @therealandrewcano 5 ปีที่แล้ว

    But I like this video alot. As an irrigator myself I really dig this video

  • @kevinjohnson9761
    @kevinjohnson9761 10 ปีที่แล้ว

    Very nice video, I love the dish soap tip. thanks for sharing

    • @Iscaper
      @Iscaper  10 ปีที่แล้ว

      Thanks Kevin for the feedback.

  • @mythril4
    @mythril4 9 ปีที่แล้ว

    I build my manifolds out of close coupled 2" PVC (I use 2" smooth to 1" thread tee's), then I pipe in the city water usually with 1&1/4 inch poly pipe from a double check valve. To clarify however, the reason I use 2" PVC is for smoother valve operation and primarily for pump/city water combinations. The pumps I use can run around 4 zones at the same time in many cases, but this is only possible with the 2" manifolds. My personal pump will run 25 3.0GPM rotors at the same time if I want it to. The city water requires one zone at a time.
    Let me tell ya, close coupled 2" PVC manifolds connecting via brass nipples to the valves and then to the poly pipe. While they not only look sexy (chuckles) but they are very easy to work on as everything stays in perfect alignment and is rigid. I normally use DVF valves from Rainbird. It's usually not necessary to remove a valve entirely, you simply replace it's guts if it fails. On 1" poly fittings or smaller I use 2 pinch claps per fitting, and anything over 1&1/4" poly I use 3 pinch clamps per fitting. No leaks and no service failures until you are much much older (provided you blow the system out for winter).

  • @Sholay48
    @Sholay48 3 ปีที่แล้ว

    Thank you. Its very comprehensive. Could I ask you whether we can build the manifold and valves over ground on a wall and then box it so that they do not get muddy and at the same time easier to get access to and maintain? Thank you.

    • @Iscaper
      @Iscaper  3 ปีที่แล้ว +1

      You could but I wouldn't. Sprinkler manifolds are generally designed to be installed underground. For me the reason is aesthetics. It would be hard to build a manifold above ground and have it look good. If you're using PVC pipe to build the manifold the PVC doesn't do well in sunlight. Also bumping a manifold under pressure with something like a lawnmower or other lawn equipment risks damage to the manifold.

  • @Iscaper
    @Iscaper  11 ปีที่แล้ว

    Thanks for the comment.

  • @Iscaper
    @Iscaper  11 ปีที่แล้ว +1

    I got the shoes at REI. They are Vasque Gore-Tex. Awesome shoes.

  • @mormonsniper5183
    @mormonsniper5183 10 ปีที่แล้ว

    Excellent. Very nice installation and explanation. Pro level. Thanks!

    • @Iscaper
      @Iscaper  10 ปีที่แล้ว

      Thanks for watching.

  • @ragerdl
    @ragerdl 6 ปีที่แล้ว

    Long but seemingly complete. Nice job :)

  • @Iscaper
    @Iscaper  12 ปีที่แล้ว

    The valves are Rain Bird 100DVFUU union valves. Of my suppliers who carry Rain Bird, only 2 of them carry this particular valve. I'm not sure if you'll have better luck with Rain Bird suppliers in your area.

  • @Iscaper
    @Iscaper  11 ปีที่แล้ว

    Drains are King auto drains. They are much more reliable than drains from years past which were ball and spring types and would tend to get debris in the drain and leak. These drains have a rubber diaphragm with filter cloth over the drain. I've had very little trouble with them. When the zone pressure hits the drain (7psi) they shut off and when the zone shuts down they open and begin draining (slowly). Rocks-gravel around drain are only necessary if you have heavy clay soil.

  • @Iscaper
    @Iscaper  11 ปีที่แล้ว

    Thanks, this installation turned into a project.

  • @therealandrewcano
    @therealandrewcano 5 ปีที่แล้ว +1

    I've never seen hose clamps used on poly , but I've also only used poly for drip (plants and trees)

  • @lorenzobatt6902
    @lorenzobatt6902 4 ปีที่แล้ว

    Excellent explanation and video. Thank you!

  • @curiousmelody
    @curiousmelody 11 ปีที่แล้ว

    What type of automatic drain do you use? I think there are different types and most irrigation professionals that I have talked with do not like to use them. We have never winterized or system and never had any problems. I do know at the end of the line which slopes down we have an automatic drain valve. Do you recognize rocks around the drain? Great site that I've subscribed too.

  • @johnvandyk2592
    @johnvandyk2592 3 ปีที่แล้ว

    Pretty sharp the way you duct taped your primer and glue together. That's a tip I'll remember.

    • @Iscaper
      @Iscaper  3 ปีที่แล้ว

      Thanks John for watching.

  • @Iscaper
    @Iscaper  12 ปีที่แล้ว +1

    I'll say. We ate some great sea food in Victoria. The lady at the hotel we stayed at said there is a running joke in Victoria that you had to be newly wed or nearly dead to live in Victoria, and that the city was trying to change that image. I didn't notice any of that when we were there.

  • @owlexS
    @owlexS 11 ปีที่แล้ว +1

    This was an awesome video. Thank you for sharing your knowledge.

  • @gustavoriquelme10
    @gustavoriquelme10 11 ปีที่แล้ว

    Gracias por compartir el conocimiento desde Argentina, Neuquén.-

    • @Iscaper
      @Iscaper  11 ปีที่แล้ว

      Thanks Gustavo for commenting.

  • @tomkane26
    @tomkane26 ปีที่แล้ว

    All of the dirt must be put back into the hole, so there is no divot around the valve box. Those bleeder valves needed gravel around them. Before cutting wires mark which wires go to what area and mark them with masking tape, and the valves that you are changing so you don't have to reprogram your controller.

  • @cspill99
    @cspill99 ปีที่แล้ว +1

    Can you help me with installation? old copper system with pvb in the basement. how can I rerun this? I have pictures.

  • @Iscaper
    @Iscaper  12 ปีที่แล้ว +1

    I went to Rain Bird's site & looked up their specs on solenoids. They are 24VAC 50/60Hz solenoids. Inrush current is .30A (7.2VA) at 60Hz. Holding current is .19A (4.6VA) at 60Hz. Coil resistance is 42-55 ohms.
    Even though the solenoids are 24VAC, most timers I've encountered put out around 28-29VAC. The lowest voltage I've seen on a timer & still have it open a valve solenoid is 18VAC.
    continued

  • @Iscaper
    @Iscaper  12 ปีที่แล้ว

    Thanks for the feedback.

  • @robertglidewell9494
    @robertglidewell9494 5 ปีที่แล้ว +1

    EXCELLENT video

  • @davidh2049
    @davidh2049 11 ปีที่แล้ว

    Should there be some backflow prevention device installed ? These are not anti-siphon valves, right?

  • @wjackstl
    @wjackstl 9 ปีที่แล้ว

    hello Kerry, I just wanted to offer a suggestion for you. when retrofitting a system from poly to pvc, I will get out my heat gun and (lightly) heat the poly, first. then I will insert any 2" to 3" (or as long as you want) off-cuts of 3/4" pvc into the 1" poly. after it's heated, it slides right in and will harden around the pvc, but I still like to add a hose clamp for good measure. I have found this to be cheaper and easier than purchasing those transition adaptors, not to mention using up scrap pvc....plus there's the added benefit of having more pipe inside the poly than the transition adaptors. just my 0.02 ¢ take care

    • @Iscaper
      @Iscaper  9 ปีที่แล้ว

      +Wesley Jackson
      Good tips, thanks for posting.

    • @raidherrideher
      @raidherrideher 6 ปีที่แล้ว

      I like ideas like that, fewer transitions and a stronger connection. this works because poly is a thermoplastic meaning it's formed/molded & REMOLDED via heat just like PVC. there are heat snakes that make up to 4" pvc into rubber noodles for odd angle connections and help avoid issues of kinking from too localized of a bend via heat gun heating of the pipe (the bend happens all in 1 short section vs. a longer sweep)

  • @MixinGreen-uk6id
    @MixinGreen-uk6id 4 หลายเดือนก่อน

    nice job, i noticed u didnt use tephlon tape. But Ive seen other guys use it. Im assuming its not required . Anybody have suggestions?

    • @Iscaper
      @Iscaper  4 หลายเดือนก่อน

      Rain Bird discontinued valves used in video. They were union valves that had an internal o-ring so teflon tape wasn't required. I've been using Action manifolds and Rain Bird 100DVF sprinkler valves since. Here's a link to a video replacing the manifold with affiliate links for the parts. th-cam.com/video/WpetroPws10/w-d-xo.html

  • @johnlynch8330
    @johnlynch8330 11 ปีที่แล้ว

    Great video, the repairs I have to do seem a lot more manageable...

  • @musicteacherbuilder
    @musicteacherbuilder 11 ปีที่แล้ว

    My old system has 1.25" valves. It seems modern Rainbird valves are now 1", 1.5", or 2". Can you replace a valve in a 1.25" system with a standard 1" valve?

  • @Iscaper
    @Iscaper  11 ปีที่แล้ว

    Small repairs I normally do by the hour plus materials. A lot of customers what to know up front what the costs will be so then I would give them an estimate.

  • @bigheadmarkie
    @bigheadmarkie 2 ปีที่แล้ว

    your tutorials are awesome!

    • @Iscaper
      @Iscaper  2 ปีที่แล้ว

      Glad you think so!

  • @spelunkerd
    @spelunkerd 12 ปีที่แล้ว

    Thanks for the quick response. I'll look into that.
    Dave

  • @roballison5076
    @roballison5076 10 ปีที่แล้ว

    Very good and very helpful for my home project. Thanks.

    • @Iscaper
      @Iscaper  10 ปีที่แล้ว

      Thanks for watching.

  • @ShortFlic
    @ShortFlic 4 ปีที่แล้ว +1

    Good video. Well done, thanks

  • @angelmarte9539
    @angelmarte9539 3 ปีที่แล้ว

    Excellent video

    • @Iscaper
      @Iscaper  3 ปีที่แล้ว

      Thanks Angel for watching.

  • @Iscaper
    @Iscaper  11 ปีที่แล้ว

    No special reason other than my sprinkler material supplier carried the hose clamps but not the pinch clamp.

  • @johnkosheluk1041
    @johnkosheluk1041 11 ปีที่แล้ว

    Good eavining kerry i allways watch your videos and learn a lot i am estimiting a spr revamp job i have a question do u est a job by the hr or give a price on the job after u look at it your in put would b gerat

  • @pac1la
    @pac1la 6 ปีที่แล้ว

    Very informative video, thank you.

  • @josedurand1132
    @josedurand1132 10 ปีที่แล้ว

    Great video! very professional, help me a lot. Thanks

    • @Iscaper
      @Iscaper  10 ปีที่แล้ว

      Thanks Jose for the comments.

    • @josedurand1132
      @josedurand1132 10 ปีที่แล้ว

      Why do you use two liquid?

    • @Iscaper
      @Iscaper  10 ปีที่แล้ว

      Jose Durand
      Two liquids? I don't understand.

    • @Iscaper
      @Iscaper  10 ปีที่แล้ว

      Kenneth Webster
      I get it, thanks Kenneth. It's primer and glue. Primer prepares the pipe and fittings so that the glue will have a good chemical bond.

  • @sharpelawncare5381
    @sharpelawncare5381 10 ปีที่แล้ว

    I like using action brand manifolds and Hunter PGV valves.

    • @Iscaper
      @Iscaper  10 ปีที่แล้ว

      Good tip, thanks for posting. I like Action manifolds also. I've also used Dura manifold parts.

  • @chuckweir1649
    @chuckweir1649 10 ปีที่แล้ว

    nice job; ready to take on my project now.

    • @Iscaper
      @Iscaper  10 ปีที่แล้ว

      Thanks Chuck and good luck.

  • @manangservices918
    @manangservices918 8 ปีที่แล้ว

    hilo whats that? silinoid valve? 220 volt why burried in the ground it safe? i make stab out water meter semilar to your project but 12 inch in the ground so easy to operate and less maintenence with directoy anyway tnx nice vids

    • @Iscaper
      @Iscaper  8 ปีที่แล้ว +1

      +albert pagliawan
      Sprinkler valves are 24 volt.

  • @culayta
    @culayta 11 ปีที่แล้ว

    Why do you chose to use to use worm fittings instead of pinch clamp fittings?

  • @jambatvee3803
    @jambatvee3803 ปีที่แล้ว

    This is perfection!

    • @Iscaper
      @Iscaper  ปีที่แล้ว

      Thanks Jamba, I appreciate the feedback.

  • @None-ij7zz
    @None-ij7zz 6 ปีที่แล้ว

    Why would you use clamps that over time rust? They leak on external garden hose and most likely worse in dirt.

  • @andymenichino8053
    @andymenichino8053 8 ปีที่แล้ว

    I was able to blow out my first few zones, then suddenly the air started flowing out of the manifold instead of into the pipes....what could I have broken and how might I fix it?

    • @Iscaper
      @Iscaper  8 ปีที่แล้ว

      +Andy Menichino
      With the air running into the system you need to feel around the pipes, fittings, and valves in the manifold to see where the air is escaping. Hopefully you don't have a broken pipe, fitting, or sprinkler valve.

  • @roadrunner123
    @roadrunner123 3 ปีที่แล้ว

    Another great video!

    • @Iscaper
      @Iscaper  3 ปีที่แล้ว

      Thanks Road Runner!

  • @garciaslandscaping1128
    @garciaslandscaping1128 10 ปีที่แล้ว

    What is the part number for the rain bird kit that you are using?

    • @Iscaper
      @Iscaper  10 ปีที่แล้ว

      Rain Bird part number is: UVMS3DVFS. Problem is Rain Bird discontinued the 100DVFUU valve so I don't know if this manifold kit is still available.

  • @marinejarheade9
    @marinejarheade9 5 ปีที่แล้ว

    I was wondering how to connect the common wires together on a nine valve manifold since the valve wires are to short to reach together?

    • @Iscaper
      @Iscaper  5 ปีที่แล้ว

      Connect the wires that will reach to a longer single wire that would connect to the common wire running to the timer.

  • @vilsan.r.9875
    @vilsan.r.9875 4 ปีที่แล้ว

    How many years before the hose clamp rots away?

  • @brianamarie8205
    @brianamarie8205 8 ปีที่แล้ว

    ha John what do u tk of the wireless timers ( Remote Typ )

  • @germansampayo2730
    @germansampayo2730 8 ปีที่แล้ว

    you need to install between the main shot of valve and the manifold bacflow prevented need's to be installed so the water flow's through the arrow and won't back in to the city water and contaminated

  • @arturozavala8677
    @arturozavala8677 3 ปีที่แล้ว

    Thats at least a $1500.00 Dollar Job in todays money👍

  • @sigguy1361
    @sigguy1361 8 ปีที่แล้ว

    Love that easy setup. Nice work. No tef-tape for the threads?

    • @Iscaper
      @Iscaper  8 ปีที่แล้ว +1

      These sprinkler valves have o-rings that keep them from leaking when the nuts are tightened. No teflon tape is needed on the male adapters.

    • @sigguy1361
      @sigguy1361 8 ปีที่แล้ว

      Looks very neat and professional, especially when it's all finished and covered. Good job!

    • @sigguy1361
      @sigguy1361 8 ปีที่แล้ว

      Another question for you: at what point would you consider making a move from 3/4 to 1" pvc for your runs, or is it unnecessary for residential? I guess with well placed, quality heads (like the ones you are using), 3/4 is sufficient?

    • @Iscaper
      @Iscaper  8 ปีที่แล้ว

      Usually most homes are fed with a 3/4" water meter so even though there would be a little less friction loss running 1" pipe on the zone lines the cost increase isn't worth it and there isn't the flow from the water meter to support it. I do like to do the manifolds, supply lines to the valves in 1" because most lawn sprinkler valves for residential applications are in 1". If a home has a 1" water meter I would definitely run 1" pipe to the heads.

    • @sigguy1361
      @sigguy1361 8 ปีที่แล้ว

      iScaper1
      Roger that. Thanks for the help!

  • @anon2414
    @anon2414 6 ปีที่แล้ว

    Wow work of art

  • @AdamMargie4ever
    @AdamMargie4ever 9 ปีที่แล้ว

    Great job on the video very helpful!!!!

    • @Iscaper
      @Iscaper  9 ปีที่แล้ว

      Thanks.

  • @lopezsotomayor
    @lopezsotomayor 10 ปีที่แล้ว

    excelente video, muy práctico.

    • @Iscaper
      @Iscaper  10 ปีที่แล้ว

      Thanks Luis for watching.

  • @jarhead0754
    @jarhead0754 6 ปีที่แล้ว

    another trick and easier to install fittings to pipe is heat up the pipe slightly.

  • @kalamelliel
    @kalamelliel 4 ปีที่แล้ว

    Where do you get your fittings from generally

    • @Iscaper
      @Iscaper  4 ปีที่แล้ว

      Rain Bird quit making the union valves a few years ago, I'm using Action Machine manifolds now. Here's a link: th-cam.com/video/WpetroPws10/w-d-xo.html

  • @omutakaeddie
    @omutakaeddie 9 ปีที่แล้ว

    Thank u 4 the good idea u hv given .

    • @Iscaper
      @Iscaper  9 ปีที่แล้ว

      Thanks Eddie.

  • @tracyr5594
    @tracyr5594 6 ปีที่แล้ว +1

    This was a very long project. I bet you were there all day.

  • @Eddybarrett84
    @Eddybarrett84 ปีที่แล้ว

    Use a smaller Dopper from the smallest glue bottle w/ pint glue can.1” -1/2’ smaller doppers are best

  • @d7c7d
    @d7c7d 12 ปีที่แล้ว

    Excellent video. Thank you.

  • @jasonbranson448
    @jasonbranson448 4 ปีที่แล้ว

    Thanks, learned a lot

  • @larrykluckoutdoors8227
    @larrykluckoutdoors8227 4 ปีที่แล้ว

    Good video. Thanks

  • @danielmcdonald9433
    @danielmcdonald9433 10 ปีที่แล้ว

    Thank you sir! Very helpful

    • @Iscaper
      @Iscaper  10 ปีที่แล้ว

      Thanks, I appreciate the feedback.

  • @constantbuzz
    @constantbuzz 6 ปีที่แล้ว

    no leak test before back filling?