The difference between 1 Phase 220V and 3 Phase 380V Inverters
ฝัง
- เผยแพร่เมื่อ 28 มิ.ย. 2023
- The difference between 1 Phase 220V and 3 Phase 380V Inverters
This difference in inverters can be an option for you beginners, so you don't choose the wrong inverter and don't choose the wrong electric motor, make sure and adjust it to your needs and conditions in your installation area.
Inverter 1 Phase to 3 Phase 220V
Inverter 3Phase to 3Phase 220V
To Add Insight to a Beginner Rewinder or Dinamo Roll Technician or as a reference for comparison when encountering problems in practice in the field.
Based on this theory, it can be used as a reference as a description or to obtain a calculation formula.
Greetings One Hobby
TECHNICAL UJM
Panel Electrical Technician, Rewinding Electromotor, Electromechanics. - วิทยาศาสตร์และเทคโนโลยี
Semangat Terus Buat Kontennya....
Terima Kaaih
Terima kasih , ulasanya jelas dan mudah dimengerti , untuk pemrogramanya dibuat vidionya Om .
Sama2....!! Terimq Kasih sudah mampir Chanel UJM Teknik.
Terima kasih pak atas ilmu nya,penjelasanya mudah di mengerti 🙏
Sama2....Mas.
Jangan lupa di share ya...
Keren pak pnjelasan sngt rinci mudah dipahami bagi saya org awam 🎉
Terima Kasih sudah mampir Chanel UJM Teknik.
Jangan Lupa Subscribe, Like, & Share ya....
Pemula, nyimak ilmu yh, bng, kbetulan, ane brencana membuat mesin konveyor mkanan untuk usaha kcil , memng sngt/harus di perhtikn, apa2, yg hrus di butuhkn, dgn meliht spek, dan fungsi yh, trimakasih ilmu yh bng, mntp jdi fham.👍
Betul,,,,!!
Apalagi buat conveyor, rasio gearbox yg dpkai, spek dinamo yg digunakan, inverter yg digunakan, beban yg akan ditarik, dissuaikan brdsrkan kbutuhannya.
Terima Kasih sudah mampir, jgn lupa Subscribe, Like, share & bunyikan loncengnya untuk mngetahui update video. 🙏🙏
Buat tutorial nya bang untuk conveyor ya 🙏
Jika motor saya 1 phase bisa kah pakai inverter..?
Apakah sama pengertian kalimat " Inverter sm dgn Sambungan . ?😮 mhn penyegaran. Krn listrik yg blajar itu hrs paham.ok pk. Trima ksh.
Tentu Beda Mas, silahkan di WA sja jika ada yg kurang paham, kita sama2 belajar. hehehe
bang. klo di namplate dinamo cma tertera 380v tidak ada simbol star dan delta. itu koneksi nya gmana.? apa lagi sampe 30hp. yg banyak beredar di indonesia kan tipe tipe sperti itu.??
Keluar kabelnya berapa Mas? 3 atau 6? Di Name Plate, biasanya tetap mencantumkan Voltage yg dipakai.
Misal Delta 380V atau Hanya STAR 380V.
Konsumsi listrik dnmo itu yg d hitung amper saat kerja to daya yg tertera d nemplet?,,,misal 15hp11kw apa daya itu yg d konsumsi /jamnya?
Yang dihtung untuk Konsumsi listrik, yaitu menggunakan aktual pengukuran saat running sudah ada beban.
Kalaw Ampere di Name Plate, itu kapasitas ampere maksimal kerja dinamo.
Apakah bisa di pakai untuk mesin cutting plasma 3 phase kah bang
Kalau untuk mesin Cutting Plashma, sya blom pernah Tes Mas.
Hanya Inverter untuk Dinamo saja...
Nanya bang,misal inverter kw nya lebih gede daripada kw dinamo GPP ya
Gak papa Mas, menurut pengalaman saya, memang standarnya harus diatasnya.
Misalkan Dinamo 1,5KW, kita gunakan Inverter 2,2KW.
Apakah inverter 3p 380v to 3p 380v bisa menggantikan fungsi dari panel star delta? Misal pada dinamo 30hp
Secara Fungsi, inverter juga bisa mengurangi lonjakan arus yg besar saat start, juga sdah bisa disetting diprogramnya, baik itu Ampere, Overload, dll.
Bisa dikatakan seperti itu Mas, tetapi jangan lupa sistem pengawatan dari listrik PLN ke inverter pun jika melihat skema pada manual book inverter mitsubishi, dilengkapi Kontaktor + Thermal Overload Relay juga, walawpun fungsinya hanya ON OFF saja (DOL).
@@ujmteknik bila d bandingkan antra star delta, inverter, dan soft starter, masih mending yg mana unt dinamo dg beban konstan dari segi biaya, perawatan, dan kehandalan?
Mtur suwon...
Saya lebih cenderung menggunakan Inverter, wlaupun dri segi Cost lebih mahal, tetapi lebih aman & hemat listrik, jika digunakan sesuai kebutuhan.
Saya punya dinamo 15kw.
Rencananya mau pake inventer. 1 pas ke 3 pas..
Harus pake yg brp kw gan?
Saran saya, kalau sudah diatas 5,5 KW, itu lebih baik pakai listrik 3phase 380V.
Kalau pun mau menggunakan Inverter, gunakan inverter 3 phase yang 380V to 380V.
Kak inverter saya 1 phase ke 3 phase ssring kebakar kirakira knp ya kak..apa karena udara panas atau tegangan kurang ya kak
Type 1 Phase 220Vke 3phase 220V atau Type1 Phase 220V to 3Phase 380V? Ada 2 type nya, itu pke yg mana?
Biasanya Yang sering Problem type 1 phase 220V to 3 Phase 380V.
Saya punya dua dinamo 0.6 kw Ama 1.6 kw misal pake 1 vfd 2.2 kw bisa ya
Maksudnya 2 Dinamo dijadikan 1 ya, pakai Inverter yang sama?
Alangkah Baiknya sesuai petunjuk manual booknya, gunakan satu Dinamo = 1 Inverter...!!
Maaf mau tanya, kalau inverter 1 phase 3.7kw dipakai untuk motor spindle 2.2 kw bisa tidak ya?
Bisa Mas....!! Itu lebih bagus...!!
Kalaw Inverternya 220v to 220V 3phase, maka Dinamonya juga harus DELTA 220V, jangan dipasang STAR 380V.
@@ujmteknik trimakasih mas ilmunya.
@@fajardian7683 sama2 Mas....!! Jika ada yg ditnyakan, mengenai Elektrik Panel, Star Delta, Otomatisasi, Elektromotor, dll, silahkan dikomen za.
Itu artinys 220 3 phasa dan phasa to netral 110 volt .
Inverter VFD ga ada Netralnya Mas.....!! 3 Phase 220V.
Mau tanya dong om, klo spek inverter yaskawa 3 phase... Input 380-460V 3 phase... Output 0-460V 3 phase... Untuk inputnya bisa pakai 220v biasa kah L1 dan L2 doang?... Output yg dbutuhkan untuk motor 220V 3 Phase
Jangan Mas,,,,!! Gunakan sesuai spek & peruntukannya.
Kalawpun bisa hidup, tp ga sesuai speknya.
@@ujmteknik klo pake step up 220 to 380 bisa ga kira"om ? Klo bisa spek step up nya brapa watt?
@@cadgroup_art Kalau inverter 380V, inputnya kan 3 Phase....!! Kalaw input PLN single phase 220V.
Maksudnya input 3 phase 380v pakai 1 phase 380v apakah tdak apa"?, ini saya coba input pake 1 phase 220v alarm nya menunjukan under voltage protection@@ujmteknik
Soalnya ada inverter 3 phase 220v bisa pakai 1 phase 220v @@ujmteknik
Mau nanya kk, saya pasang inverter 1phase ke 3 phase 380vpakai inverter shzk 3kw kabel sudah keluar RST nya, instalasi ke dinamo 2,5kw 380v namun tidak bisa error 04
Coba lihat di Manual Book Mas, Error 04 itu apa? Over Curreng ataw apa?
Trus jangan Lupa kalaw Inverternya 1Phase 220V to 3Phase 380V, jamper Seng Dinamonya disesuaikan.
Bila di Nameplate tertulis 220/380 maka dipsang STAR.
Sorry nimbrung mas,saya juga
begitu mohon pencerahan nya mas apa inverter mas @haris sudah bisa?
maaf mas belum bisa masih disimpan saja😄@@tamanahook8687
terimaksih@@ujmteknik
Sama mas saya juga Uda 2mggu GK bisa2😁😁😁
Kalau dinamo 1 phase bisa pakai inverter gk om... Kalau bisa inverter'y pakai yg apa? Terima kasih
Ikut nyimak..semoga di jawab
Kalaw melihat di Skema pada Manual Book inverter merk tertentu memang ada Mas, tapi saya belum pernah Ngetes atau menghidupkannya.
Ada 2 macam Dinamo, 1 yang menggunakan Platina ( Dinamo Starting) dan yg ke 2 Dinamo Running atau yang langsunh di Couple kapasitor Running.
Nah menurut saya, yg memungkinkan bisa adalah type yang ke 2, karena kalaw type yg pertama saklar centrifugal tidak bisa membuka pada putaran yg rendah.
Nanti saya akan bantu Coba praktekan, mengenai pertanyaan ini.
Terima kasih sudah mampir Channel UJM Teknik,,,,👍👍
Alhamdulillah penasaran saya sudah sedikit terobati hehehe gas buat konten bang....ditunggu percobaanya...
Kalo 3 pasha ,,bisa dirubah ke 1 pasha k min
Secara teori bisa mas, karena memang ukuran Kern Stator dan Rotor sama secara HPnya, hanya saja ukuran kawat berbeda dan pada 1 phase dipasang saklar sentrifugal, kalaw memang bisa dipasang saklarnya, tetntu bisa.
Tapi biasanya akan lebih mudah dipasang Elektrik Sentrifugal jika ingin merubah 3 phase ke 1phase, nah ini yang jadi pertimbangan...karena harganya lumayan...!! hehe
Bang ijin bertanya. Saya sudah pasang daya listrik 6600 3 phase 10A. Tapi daya dinamo sy 5.5kw 7.5 hp jadi ketika dinyalakan listriknya langsung jepret. Kira kira sy butuh inverter atau tambah daya listrik? Mohon pencerahan 🙏🏼
Solusinya sudah dijelaskan via WA ya....👍👍
Apakh Motor 1 Phase bisa diatur kecepatanya?
Apakah ada inverter 1 Phase to 1 phase?
Jika melihat Skema di Inverter yg Made in China merk INVERTER, itu ada skema untuk motor 1 Phase...!!
Tapi saya belum pernah Trial atau Tes menggunakan motor 1 Phase.....
Mau tanya bg,saya coba pasang blower keinverter niatnya mau mengatur speed blower tetapi kenapa pas dihidupkan inverternya ada tulisan eror ya,0.75kw,220v - 220V
Mohon dibantu solusinya BG kira2 bagaimana
Errornya Kode apa? Harus dicek di Manual Booknya, apakah itu Overload atau Overheat atw apa?
Name Plate dinamonya 220/380 & pastikan dipsang Delta 220V jika inverternya 220 to 200V 3 phase.
@@ujmteknik kalau dinami motor 220 volt 1 phase gimana pak cara masang nya mohon di jawab
dinamo
@@user-vj5wj5cu2g dinamo nosch 1 phase
Maksudnya dinamo 1 Phase merk NOSCH mau pakai Inverter, supaya speednya bisa diatur??
Invelter saya copot kabal di dalam mohon petunjuk
Maksudnya ada kabel yg lepas ya Mas, dalam inverternya?
Dibuka saja Mas & lihat posisi atau jalur kabelnya, dipasang lagi jika pakai socket, kalaw solderan ya di solder lagi Mas...
Iya tapi tidak tau titik nya karena tidak meninggalkan bekas solder
Bapak rumahnya mana, so,Ale saya mau pasang inverter, tapi ditempat saya, ga,ada tukang pasang inverter
Saya di Tasikmalaya Mas....!!
Bapak darimana?
@@ujmteknik kok jauh ya pak saya Magelang jateng
@@HarditoHarnyot-qw8zi iya Mas jauh. 😊
Inverter merk apa yg dipasang Mas?
@@ujmteknik inverter belum ada, rencana mau beli sekalian minta dipasangkan, buat dinamo 3 pas, mesin Milling, listrik di rumah 220
@@HarditoHarnyot-qw8zi Lanjut di WA za Pak : 082310094123. Di saya kebetulan ada Stock Inverter 1 Phase to 3 Phase.
Tanya bang... kalo spindle di hidupkan bentar panas... kira setting parameter apa yg salah? Trm kasih
Spindle As Rotor atau Spindle Mesin Mas?
@@ujmteknik spindle yg buat cnc router itu mas. Padahal masih baru. Apa ada yg salah setting parameternya ya?
1500w 3phase 220v
@@atthewin spek motor Spindle nya udah sama juga 3 Phase 220V?
@@ujmteknik sama bos