INSANE MOISTURE CONTAMINATION

แชร์
ฝัง
  • เผยแพร่เมื่อ 29 ก.ย. 2024

ความคิดเห็น • 324

  • @jonsaircond8520
    @jonsaircond8520 2 ปีที่แล้ว +108

    "entire contents of the van on the roof" yea I felt that one

    • @k.sullivan6303
      @k.sullivan6303 2 ปีที่แล้ว +3

      Now imagine if that job is in Montreal Canada in January up on that roof. I could do California in my sleep. LOL

    • @k.sullivan6303
      @k.sullivan6303 2 ปีที่แล้ว +1

      and in my dreams

    • @jonsaircond8520
      @jonsaircond8520 2 ปีที่แล้ว +4

      @@k.sullivan6303 As a guy from Texas I'd have to nope out of the in January anywhere up north. Guess it's not much different than me in August

    • @cliveramsbotty6077
      @cliveramsbotty6077 2 ปีที่แล้ว +3

      i work natural gas but don't touch f gas - always feel glad i don't when i see the sheer amount of stuff you guys have to drag around site. brutal.

    • @BensSightSoundandAuto
      @BensSightSoundandAuto 2 ปีที่แล้ว +3

      He should just get the crane out to bring the van up on some of these jobs 😂😂

  • @deaconwanderer2409
    @deaconwanderer2409 ปีที่แล้ว +1

    I’ve had the water issue happen before, found a low pressure switch had snapped off on a Carrier 5OTC unit, of course the switch was on the top of the suction right under a CFM. It had rained a lot in the previous days before the call. Purged the line with Nitro but u could hear water flowing in the refrigerant line. Yea customer did not want to replace he wanted it fixed, kept getting that milky oil in my vacuum. Ended up drilling a hole in the lowest point of that circuit with a zip screw(non-bit tip) and a lot more water came out. Glad the pressure switch tripped as the compressor did sound ok. Put both driers in it recharged and changed them both out after a few weeks. System has been running for 3+ years now. With minor things(caps, contactor) going wrong since.

  • @preece7584
    @preece7584 9 หลายเดือนก่อน

    I had the same issue with oil contamination because unit came flat without any gas and another tech did a leak search pulled a vacuum i came back next cooling season found a leak and had to replace condenser, other tech doesn’t like micron gauges, so entire time pulling a vacuum he was pulling in moisture

  • @crypto_riddler8012
    @crypto_riddler8012 ปีที่แล้ว

    As mentioned below…it is an LG compressor. Not sure about that one, but I can speak from experience, the variable speed LG compressors on home refrigerators are/were terrible. It was nothing to see those fail within 6 months of purchase/installation at homes.

  • @shuaib8908
    @shuaib8908 2 ปีที่แล้ว

    Extra discharge reeds are for extreme high discharge temp. One reed acts normal and the others stay close. If the discharge temp gets really hot then the extra reeds open.

  • @j2r01
    @j2r01 2 ปีที่แล้ว +4

    Never been this early before.

  • @daemoncan2364
    @daemoncan2364 2 ปีที่แล้ว

    That is not an A/C unit. It's a milkshake machine.

  • @Boraxo
    @Boraxo 2 ปีที่แล้ว +1

    No insulation on the TXV bulb ?, or is that just for refrigeration ?

    • @petersmart1999
      @petersmart1999 2 ปีที่แล้ว

      Txv bulb should always be insulated,that way there is no interference from ambient air!

    • @Boraxo
      @Boraxo 2 ปีที่แล้ว

      @@petersmart1999 That's what I thought too, but clearly there is none on this unit.

    • @petershepherd6889
      @petershepherd6889 2 ปีที่แล้ว

      @@petersmart1999 As a new starter for Denco I went to a carrier water chiller that kept tripping on LP in the winter.
      The long serving Denco engineer with me couldn't resolve the problem but as soon as I looked at the TXV I could see the problem.
      The capillary on the TXV bulb was very long and wasn't insulated so it was affecting the TXV and causing it to close down because of low ambient temperature.
      Wrapped capillary in armaflex insulation and problem never re occurred.👍

  • @jamesbutler5570
    @jamesbutler5570 2 ปีที่แล้ว

    and you are using non metric units. nananahh

  • @davida1hiwaaynet
    @davida1hiwaaynet 2 ปีที่แล้ว +70

    Wow, that was quite a lot of water!
    This reminds me of a project I was on last year in Korea. A large oil and gas production platform was built there, for use in the Gulf of Mexico. The place has many different split unit A/C's for the different parts of the facility.
    The facility was transported here to the States for final commissioning. During the first year, ALL of the compressors started failing; many shorting to ground and others seizing up. The company who represented the HVAC side of the project found water in the systems. They connected a vacuum pump and let it run. After about an hour, they returned and found the pump overflowing with oily water! They had to bring a special pump which had an oil treater unit which recirculated the oil and removed water. It collected two gallons from one of the larger systems.
    The investigation found out that the Korean shipyard had hydro tested all the refrigerant lines, using water. The temperature at that time of year was well below freezing in Korea. They had blown the lines with nitrogen (or more likely shipyard utility air) and then evacuated. However, there was ice in the system which, of course, didn't evacuate. I have no idea what it cost them, but the shipyard was fully responsible for this messup!
    I was on site working on the power generation equipment, but talked a lot with the HVAC guys and got the story. There were a couple pallets of dead compressors on the facility before I left. It was massive carnage. No telling what it cost!

    • @zachstone1939
      @zachstone1939 ปีที่แล้ว +3

      maddog 2 at samsung?

    • @davida1hiwaaynet
      @davida1hiwaaynet ปีที่แล้ว +1

      @@zachstone1939
      LOL how the hell did you guess that!

  • @Boraxo
    @Boraxo 2 ปีที่แล้ว +137

    Our recovery tanks get hydro-tested every so often. We had one come back with almost a quart of water in it.

    • @timothystevenson7907
      @timothystevenson7907 2 ปีที่แล้ว +4

      @@Grauenwolf not a HVAC Tech but I imagine it would be easier to get it professionally dried. I'm sure there is a process you can follow but I imagine it takes alot of time.

    • @crazycory25
      @crazycory25 2 ปีที่แล้ว +12

      Then the testing facility did something wrong. When we hydro test tanks we steam dry them while they’re upside down, then if there’s still any water in them we stick an air wand into the tank and blow it out with dry air

    • @Boraxo
      @Boraxo 2 ปีที่แล้ว +1

      @@Grauenwolf Just dumped it and pulled a good vac.

    • @rickw4160
      @rickw4160 2 ปีที่แล้ว +6

      @@Grauenwolf in theory if you pull a vac on it it will all dry out.

    • @throttlebottle5906
      @throttlebottle5906 2 ปีที่แล้ว +4

      that's the only safe way to high pressure test a vessel, water(or other thin liquid equivalent to water). if it does fail, minimal bad things happen, as compared to filled with air or other gas that will also compress to a partial liquid and retains a massive amount of energy. a larger gas filled vessel rupturing can easily level a whole building and more, even if they do it within a huge tank of water, it can flatten a large area and leave a crater hole. 😬 💣 🧨☠️

  • @laskahvac666
    @laskahvac666 2 ปีที่แล้ว +305

    Chris, that magnet you found in the bottom of compressor is probably used to catch metal shavings, similar to what you'd find on an oil drain plug or transmission pan on your vehicle. It failed because it's an LG.

    • @analogmoz
      @analogmoz 2 ปีที่แล้ว +174

      What slander. I had a LG compressor work just fine for 3 months once.

    • @laskahvac666
      @laskahvac666 2 ปีที่แล้ว +39

      @@analogmoz * Guinness Book of World Records would like to know your location *

    • @Meteora125
      @Meteora125 2 ปีที่แล้ว +6

      I thought the same thing about that magnet in the bottom!

    • @wkenealey
      @wkenealey 2 ปีที่แล้ว +23

      @@analogmoz Wow! Must have been the one that was built on a Wednesday.

    • @SupremeRuleroftheWorld
      @SupremeRuleroftheWorld 2 ปีที่แล้ว +8

      @@analogmoz no way, we demand proof.

  • @irdmoose
    @irdmoose 2 ปีที่แล้ว +84

    The magnet in the bottom of the compressor doesn't look out of place to me. Automotive applications do that too. Typically your oil drain plug in your car will have a magnet on it to catch small particles of metal and keep it from getting circulated back through the system. The same thing in your transmission, there's usually a strong magnet in the pan that collects metal shavings.
    Looking at the big picture, I see two strong possibilities. Since the initial recovery didn't turn up all that moisture, it really makes me doubt it was in the old compressor unless you didn't take it down to a vacuum. If you didn't pull a hard vacuum on the system, then it's entirely likely that there was some severe factory moisture contamination. It could have even been sabotage by a factory worker who knew they were getting fired (I've seen that happen more often than I care to admit).

    • @JohnDoe-bd5sz
      @JohnDoe-bd5sz 2 ปีที่แล้ว +22

      Not only did the initial recovery not turn up all that moisture, but when you see him draining the old compressor, the oil that poured out of it, looked to be clear and not contaminated.
      I bet, the new compressor had a small leak, where the factory did not seal it.
      As far as i know, compressor oil i very hygroscopic, so if the compressor had a small leak, and it was stored somewhere moist, the oil would very quickly suck up a lot of moisture.
      My guess is the old compressor failed mechanically, and the moisture contamination was in the oil of the new, due to the new compressor not being sealed properly.
      In any case, it's good craftmanship to check, and to just keep flushing until the oil is clear, so he did this very professionally.

    • @ehsnils
      @ehsnils 2 ปีที่แล้ว +9

      @@JohnDoe-bd5sz Just hope that this unit don't die soon again due to the moisture because it could have corroded the new compressor pretty badly.

    • @JohnDoe-bd5sz
      @JohnDoe-bd5sz 2 ปีที่แล้ว +7

      @@ehsnils Yeah i agree....But if it does, i hope it does so, very fast, because then it will again, be a warranty repair.
      But yeah, that "new" compressor could be really rusted out inside...

    • @stephenwalls9277
      @stephenwalls9277 2 ปีที่แล้ว +3

      The compressor was sealed, When they removed the shipping plugs, the case was pressurised. 14:25

    • @JohnDoe-bd5sz
      @JohnDoe-bd5sz 2 ปีที่แล้ว +5

      @@stephenwalls9277 But for how long was it at the factory unsealed. Maybe it was not pressurised at once, when it came off the line.

  • @jessej.huntwork4959
    @jessej.huntwork4959 2 ปีที่แล้ว +34

    I had a refrigerant jug of 409a that had water in it. I had like 4 systems that were all getting moisture and I couldn't figure out why, they were all 409 and I had just worked on all them. Turns out there was water in the tank. I put some liquid in a cup and when the refrigeratant boiled off there was standing water in the cup still

  • @Shmash_whatever
    @Shmash_whatever 2 ปีที่แล้ว +80

    Hey Chris.
    That broken piece on the compressor is called the Oldham coupling. It keeps the moving scroll from rotating around the shaft while the compressor is running.

  • @thomasvlaskampiii6850
    @thomasvlaskampiii6850 2 ปีที่แล้ว +18

    That poor compressor was tortured, refused to say where the others were, and was murdered for it

  • @619miketseng
    @619miketseng 2 ปีที่แล้ว +24

    I have had a shop guy remove the rubber plug and let the compressor sit out on the truck over night. Cool thing was it had a sight glass on the compressor. I got to see the amount of moisture bubbling out of the oil... It was a lot and took more than a triple evacuation to get all the water trapped in the oil. I'm glad I work for another company now.

  • @dennishamilton772
    @dennishamilton772 3 หลายเดือนก่อน +3

    Hello Chris…
    I am NOT an HVAC tech, but found your videos, and love to watch you do your work. You are a superb tech in how you go over the whole picture when working on the RTU systems. I don’t know what you are talking about when it comes to your gauges readings. I’m an electrician, and understand how you check for shorted 3 phase compressors and bad contactors. I do have a company that calls me to do some of the Seimens and Novar EMS systems. I work with their tech support in replacing thermostats and their main control in the backroom, and their board in the RTUs. So I’m just touching the tip of the iceberg in remote controlled EMS HVAC and Lighting systems. I am picking up some neat tips from your videos and enjoy watching you work. Had a new store where the visitable heater never worked since the store opened. I checked for 24 volts on the thermostat, and got 0 volts. Support told me to find the control for the heater/fan. I found a transformer and contactor above the drop ceiling and was checking it out while talking with my support person. I had 208 volts on the line side of the contactor, and noticed the transformer 208 taps was on the load side of the contactor. I told my support person this don’t look right, the transformer should be on the line side of the contactor. Soon as I switched the trans to the line side all came up with the fan/heater, and my support guy said “now I can see it” I get into some crazy stuff working with these guys on the HVAC & Lighting systems. At least if we can’t get the RTU running when I swap out a thermostat or board, I can check enough other stuff in the RTU where I can tell them to get a real HVAC tech to fix the problem which is out of my scope of work on these systems.
    You say you don’t know everything, but in my book, you are a great tech and do really great work.

  • @williegillie5712
    @williegillie5712 2 ปีที่แล้ว +23

    I tore apart a rebuilt starter after it failed less then a month after a buddy of mine replaced it. We tore it down and I couldn’t believe my eyes. There’s usually a set of four magnets attached inside with an armature. I pulled the end off with the brushes and when I took the thing apart All four magnets had moved around inside the housing. They were not attached to anything. I couldn’t believe me eyes. We ended up rebuilding his old starter and he’s been using it worry free for the last five years.

  • @CrazyDragonChan
    @CrazyDragonChan 2 ปีที่แล้ว +16

    Could have the moisture come from the recovery tank when you recovered and reused refrigerant from the first visit?

    • @HVACRVIDEOS
      @HVACRVIDEOS  2 ปีที่แล้ว +3

      I will discuss this on my live stream this evening on TH-cam 11/29/21 @ 5:PM (pacific) come over and check it out th-cam.com/video/jaqX-Q3oC84/w-d-xo.html

  • @GlenS123
    @GlenS123 2 ปีที่แล้ว +22

    Compressor doesn't have reeds, those "reeds" were its check valve, odd design. Muck at top due to lack of lubrication, crazy oxidation/plating going on. Moisture was aleady in there, which means factory never evacuated properly. Hope you get to go back and change drier. One of your better videos!

    • @throttlebottle5906
      @throttlebottle5906 2 ปีที่แล้ว +1

      I'd say the reeds are there as liquid pressure relief ports for when it gets slugged.
      under operation the outlet pressure on top of the reeds should be equal or higher than pressure behind the reeds within the scroll, unless there's something non-compressible, which would open the reeds and correct the harmful condition. the reed ports would also get covered up at a certain point within the rotation.

  • @mikec.2746
    @mikec.2746 2 ปีที่แล้ว +15

    It's interesting that the dryer didn't plug or the txv didn't fail. That was quite a bit of moisture.

  • @denrayr
    @denrayr 2 ปีที่แล้ว +24

    The old compressor didn't appear to have rust on the inside. I would think there would have been heavy corrosion with the amount of moisture that you pulled out of there.

    • @HVACRVIDEOS
      @HVACRVIDEOS  2 ปีที่แล้ว +6

      I will discuss this on my live stream this evening on TH-cam 11/29/21 @ 5:PM (pacific) come over and check it out th-cam.com/video/jaqX-Q3oC84/w-d-xo.html

    • @hgbugalou
      @hgbugalou 2 ปีที่แล้ว +4

      If there is no oxygen in the system there will not be corrosion even with water.

    • @hgbugalou
      @hgbugalou 2 ปีที่แล้ว

      @Peter smith Normally I would agree, but the O2 could of been greatly reduced if the system was pumped down to a vacuum at any point. Water doesn't hold on to oxygen nearly as well in a vacuum because as you said, its probably going to boil off. There is likely some amount of oxygen left but not nearly enough to cause wide spread corrosion. In any case, its all hypothetical and this is an odd one.

    • @mattnsac
      @mattnsac 2 ปีที่แล้ว

      @@hgbugalou Water is 1/3 oxygen. If that was the case, any cars, boats or planes that went in the water should look as good as the day they submerged.

    • @hgbugalou
      @hgbugalou 2 ปีที่แล้ว +2

      @@mattnsac Water is an extremely stable molecule and the oxygen is not going to just randomly disassociate from the hydrogen atoms without electrical input via electrolysis or a very particular chemical reaction that is not present in most situations. If this were the case as you are saying, we could of solved energy long ago by just collecting hydrogen from the oceans from these random molecular break downs. Water being so nonreactive is part of the reason why its a good solvent. All corrosion from water comes from oxygen species, mainly plain old O2 dissolved in the water along with other things like salts.

  • @Kustomgadget
    @Kustomgadget 2 ปีที่แล้ว +45

    I had a restaurant owner provide a used condenser unit, for his small walk-in freezer, that had been stored for five years in his garage. Upon delivery I noted that the king valves were open and told him it was probably highly contaminated but he insisted so I installed it with a new oversized filter and after purging it with nitrogen. Sure enough, after 2 days on the vacuum pump and a bunch of oil changes, I managed to get it below 500 microns. I charged it up and started it. Yeah, the stuff I saw in the sight glass was crazy. I'm pretty sure there was insect parts and other debris flying around the system. Knowing what I know today I should have pulled the compressor and, at the very least, changed the oil. I really think the receiver and accumulator were all contaminated beyond anything I could have cleaned up though. Sometimes you just have to say no.

    • @lopaka79
      @lopaka79 2 ปีที่แล้ว +2

      No good deed goes unpunished. Was there savings at the end or were there multiple issues? I'd go as far as giving my knuckle-headed customers a questionable competitor's business info and state "some people will do anything for money, right or wrong". Most times customers will say they want it done right.

    • @murkyturkey5238
      @murkyturkey5238 2 ปีที่แล้ว +3

      @@lopaka79 lol just send it if that’s what he wants, I would give him my advice but if he wants to pay me over and over, why not

    • @murkyturkey5238
      @murkyturkey5238 2 ปีที่แล้ว +1

      Lol that’s messed up beyond what a vacuum can fix

    • @wolfjustin2
      @wolfjustin2 2 ปีที่แล้ว

      1

    • @wolfjustin2
      @wolfjustin2 2 ปีที่แล้ว

      q

  • @jmgrefrigeration4000
    @jmgrefrigeration4000 2 ปีที่แล้ว +4

    Im willing to bet it happened in manufacturing. My guess is when unit was being assembled compressors were left open to atmosphere too long before being brazed, pressure tested, and Vacuumed. Once you get moisture absorbed by POE oil it will never come out. You can clean it up but never will get it non-milky without an oil change.

  • @GeenIdee2
    @GeenIdee2 2 ปีที่แล้ว +19

    18:41 What I've learned as a car mechanic: If you get yourself some rubber hose, like 8mm ID or something, you can use that as a spacer for securing lines. Cut it to desired length, put a ziptie in, loop it around pipe one and go back trough the hose, then loop it around the other pipe and tighten the ziptie. Hope it helps!
    Find your video's pretty interesting, systems are so much different then car a/c's

    • @adamdnewman
      @adamdnewman 2 ปีที่แล้ว +3

      That's a great tip (not a hack but an actual solution)!

  • @Uncle-Duncan-Shack
    @Uncle-Duncan-Shack 2 ปีที่แล้ว +12

    You need to consider a vfd which can do broken belt detection on the blower, some of them can do it and it is worth having on these rtu's to save the compressors from no load conditions.

    • @jasonjohnsonHVAC
      @jasonjohnsonHVAC 2 ปีที่แล้ว +9

      It had a VFD on it. It was located by the compressor. Looked like it was a Mitsubishi VFD

  • @icesoft1
    @icesoft1 2 ปีที่แล้ว +5

    @29:10, that rectangular pocket where the motor shaft goes into the lower scroll is supposed to be able to turn in the bottom of the lower scroll... If it's seized/welded in, that would be (a sign of) your problem. The fact that you dumped so much oil out of the compressor suggests to me that the oil pump was not functioning - look inside the bottom of the hollow motor shaft, there might be a piece of sheet metal in there that is supposed to pump the oil up the center of the shaft to the bearing at the top (that's seized into the lower scroll).

  • @madeofscars9355
    @madeofscars9355 2 ปีที่แล้ว +9

    That finish on the cast components (guessing cast steel) that's rust they should be a light silver/grey 🤔 that thing must have been swimming in water for that to happen.
    that bluing on the shell is likely from assembly everything will be an interference fit which they likely heat the shell up and expand it and drop it over the rotating assembly and it all locks together when the shell cools and contracts.
    it's concerning how much moisture was in that system though one thing I can think of that could have contributed to the cause of the failure is the water freezing and blocking the txv and causing an intermittent high head pressure scenario.

    • @aviator775
      @aviator775 หลายเดือนก่อน

      That was copper plating from the moisture becoming acidic which pulls copper from the refrigerant lines. It gets squeezed back out of solution and deposited on tight spaces such as bearing clearances and between the scroll sets.

  • @chrisyuriar9751
    @chrisyuriar9751 2 ปีที่แล้ว +4

    Everytime I come across a LG compressor that is bad I retrofit to a Copeland. Have never had any luck with them.

  • @inothome
    @inothome 2 ปีที่แล้ว +8

    The magnet is what everyone else is saying. Those reeds and ports could be for over-pressure relief or if it gets flooded to relieve the liquid (over-pressure). Since those ports were along the scroll.

    • @HVACRVIDEOS
      @HVACRVIDEOS  2 ปีที่แล้ว +1

      I will discuss this on my live stream this evening on TH-cam 11/29/21 @ 5:PM (pacific) come over and check it out th-cam.com/video/jaqX-Q3oC84/w-d-xo.html

  • @philltafolla
    @philltafolla 2 ปีที่แล้ว +6

    Good video Chris . I believe your nitro tank had CO2 instead of Nitro . Happen to me 🤭😀😅

    • @HVACRVIDEOS
      @HVACRVIDEOS  2 ปีที่แล้ว

      I will discuss this on my live stream this evening on TH-cam 11/29/21 @ 5:PM (pacific) come over and check it out th-cam.com/video/jaqX-Q3oC84/w-d-xo.html

  • @martinbradbury5920
    @martinbradbury5920 2 ปีที่แล้ว +7

    I like your videos because i find it interesting now this stuff works. Keep up with the cool videos man

  • @lazytv4318
    @lazytv4318 2 ปีที่แล้ว +5

    27:04 Like he mentioned, that tarnish looks like "bluing" if that casing is steel.

  • @christopherbezuidenhout7251
    @christopherbezuidenhout7251 2 ปีที่แล้ว +2

    Had a plate heat exchanger burst on a chiller the other day. Tried to purge the water out of the condenser coils and system. Oil looked like that after vacuuming over 2 weeks.

  • @RedFathom
    @RedFathom 2 ปีที่แล้ว +6

    magnets are common. the welds are spot welds.
    that junk in the bearings is from a spun bearing.

  • @ratchet1freak
    @ratchet1freak 2 ปีที่แล้ว +4

    I feel like the reeds in the scroll is there to be able to handle liquid flooding into the compressor, with the reeds if there is liquid in the scroll then it can squirt up instead of creating a massive backpressure on the shaft as it tries to compress a liquid.

  • @Jamie-po9zk
    @Jamie-po9zk 2 ปีที่แล้ว +5

    never seen vacuum pump oil look like that before, cool video.

  • @Combat.Wombat.official
    @Combat.Wombat.official 2 ปีที่แล้ว +4

    I love watching someone else work while I just sit here, makes my coffee taste better

  • @kevinschmidt3887
    @kevinschmidt3887 2 ปีที่แล้ว +4

    Early video nice Saturday evening surprise!

  • @erikandreassen6531
    @erikandreassen6531 2 ปีที่แล้ว +3

    Love your autopsy. Neat.

  • @bryansimon4072
    @bryansimon4072 2 ปีที่แล้ว +4

    The moisture issue with compressor is probably factory. Had a residential unit (lg) with same problem, took forever to clear up.

    • @HVACRVIDEOS
      @HVACRVIDEOS  2 ปีที่แล้ว +1

      I will discuss this on my live stream this evening on TH-cam 11/29/21 @ 5:PM (pacific) come over and check it out th-cam.com/video/jaqX-Q3oC84/w-d-xo.html

  • @lawrencecavens5760
    @lawrencecavens5760 2 หลายเดือนก่อน +1

    May I suggest - that you don't say I'm not the best, as this will give the public reason to do what they are doing in {we'll wait and see} scenario ...For what I see you do very good work..

  • @AaronCo29
    @AaronCo29 2 ปีที่แล้ว +1

    LG, Samsung, GE(Made by Samsung for GE) all have these kinds of problems, and Ironically, GE makes both LG and Samsung Major Household Appliances in Korea

  • @RandoWisLuL
    @RandoWisLuL 2 ปีที่แล้ว +1

    26:46 forgive my HVAC ignorance, but is that magnet to catch metal filings that may break off during its lifespan? They do this a lot in transmissions and differentials on cars....

  • @rwhite715
    @rwhite715 2 ปีที่แล้ว +2

    If it is an LG compressor, it is most likely stolen technology. I know, I used to work for LG in Tech Support.

  • @kmagnussen1052
    @kmagnussen1052 10 หลายเดือนก่อน +1

    The nitrogen in the tank would only have a partial pressure of water and it would be small due to the low molecular weight of water at 18. . If there was excessive water the tank would have sloshed How much water in grams do you think was in the compressor?

  • @aviator775
    @aviator775 หลายเดือนก่อน +1

    The darkened steel shell is from when they assembled the stator to the compressor shell. They induction heat the steel to expand it to allow the stator to drop in.

  • @James_Bowie
    @James_Bowie 2 ปีที่แล้ว +1

    AC units should shut down when belts break. Manufacturers could have that happen if they could be bothered -- but we all know that they can't be bothered.

  • @Goldstacker1972-kp2bh
    @Goldstacker1972-kp2bh 6 หลายเดือนก่อน +1

    They have a handke bar that goes through that eye lit o. The top.of the compressor you hook.it through the eyelit and wraps the compressor which it makes them super easy to lift.

  • @techman8817
    @techman8817 ปีที่แล้ว +1

    I would guess the reeds and the weird shape on the scroll are to make smoother output from the compressor.

  • @mysticknight9711
    @mysticknight9711 3 หลายเดือนก่อน +1

    Hey - do you ever use pig mats or other oil absorbent sheets to keep the oil from getting on the roofing and for other oil cleanup?

  • @paulb4496
    @paulb4496 2 ปีที่แล้ว +2

    The varnish on the copper wire and the string around the windings all contain moisture. A low charge condition makes the compressor run hot, driving moisture out of the windings. You see things in that hot climate I never see in Portland Oregon.

  • @johns815
    @johns815 2 ปีที่แล้ว +1

    The only info i have on LG is they SUCK.
    I will not buy LG anything ever again.

  • @Goldstacker1972-kp2bh
    @Goldstacker1972-kp2bh 6 หลายเดือนก่อน +1

    I hate trane driers. Seriously who makes a drier 3/8 on one side and 5/8.on the other side.

  • @transmitterguy478
    @transmitterguy478 2 ปีที่แล้ว +2

    Chris, did you let that moisture settle out to measure how many oz there were? Would the moisture content give a false reading of the state of charge you were seeing on your gauges? Did you cut the dryer apart to see if the moisture clogged it? When you drained the oil from the compressor into the orange bucket did any moisture settle out? Just thinkin.

  • @AIM54A
    @AIM54A 2 ปีที่แล้ว +8

    I'm going to guess the water was in your blue vacuum hose.. Perhaps an errant water hose when cleaning coils splashed onto the end when it was disconnected at your last job before before this one. Or the new compressor had the water in it.. If the old compressor had that much water in a hot compressor that mild steel would have been 100% rust on the inside even with oil splashing around. Very strange indeed.

  • @Terayonjf
    @Terayonjf 2 ปีที่แล้ว +2

    Not a fan of the LG compressors. I've found dozens dead within 3 years on package units. Even equipment that was factory commissioned. It really seems like they cut every corner to save money when making them

    • @nickwallette6201
      @nickwallette6201 2 ปีที่แล้ว

      That's how you get to the top with mass-produced products. Yay consumerism. "Which one's cheapest?"

  • @petersmart1999
    @petersmart1999 2 ปีที่แล้ว +2

    JB Black Gold is the best vacuum pump oil,hands down!

  • @fitybux4664
    @fitybux4664 2 ปีที่แล้ว +1

    0:16 Did they put lemon juice into their compressor or something? 😆

  •  2 ปีที่แล้ว +3

    Rust cannot happen in absence of oxigen.

    • @HVACRVIDEOS
      @HVACRVIDEOS  2 ปีที่แล้ว +1

      I will discuss this on my live stream this evening on TH-cam 11/29/21 @ 5:PM (pacific) come over and check it out th-cam.com/video/jaqX-Q3oC84/w-d-xo.html

  • @MovingHeatLata666
    @MovingHeatLata666 ปีที่แล้ว +1

    I have noticed LG Compressors can’t handle flooded starts. I watch the condensation line on my replacement compressors. ( similar to the way you watch receivers for winter charge ) and if the condensation is high on the compressor. There is a feeding issue with the TXV. Some TXV’s can carefully be adjusted others I have to change out with an adjustable TXV. The moisture issue has to be from the factory. 😊Hope that helps.

    • @MovingHeatLata666
      @MovingHeatLata666 ปีที่แล้ว

      Also micro channel coils in Phoenix on high ambient days cause flooded starts and main breaker or HP Safeties to trip and weaken. I’ve called Trane and got permission to pull out 5-10% of the charge to help prevent this issue. This happens to all many here. AAON,TRANE,LENNOX,HASKRIS ( Process chillers ) all responded after a small adjustment. Had a bunch to do this summer. Most extremes were on systems too close to a parapit wall or systems picking up discharge air from other systems. Poor condenser air flow. Hope that helps next summer. Now we get geared up for low ambient 😊

  • @AaronCo29
    @AaronCo29 2 ปีที่แล้ว +1

    Just seeing this video, I was in the hospital for 3 months and almost died at one point. I took a job a few years back from another contractor that couldnt get the job finished, turned out his guy, that he had just fired, poured water into the new compressor prior to installation.

  • @Mack_Dingo
    @Mack_Dingo 2 ปีที่แล้ว +1

    hilarious u fired up the AC to go eat lunch in the restaurant then turn it off after again

  • @justgonnagetbetter1037
    @justgonnagetbetter1037 2 ปีที่แล้ว +3

    Notification squad on the job

  • @TravisDoesGames
    @TravisDoesGames ปีที่แล้ว +1

    so how did the moisture get in? Water cooled condenser?

  • @nsaglian
    @nsaglian 2 ปีที่แล้ว +3

    Excellent video, and really liked the brazing montage music!

    • @ismarcfo
      @ismarcfo 2 ปีที่แล้ว +1

      Elfl Voyager Purple es la música.

  • @TravisDoesGames
    @TravisDoesGames ปีที่แล้ว +1

    pretty good numbers for a compressor full of water

  • @briant9764
    @briant9764 2 ปีที่แล้ว +1

    To someone that understands when i was a working man the worst day of the year to work was the day after Thanksgiving. Just not into it after eating and drinking to much and hanging out with family. watching football etc. You had to fight mall traffic, extremely busy kitchens. I know i just oozed the attitude with managers IDK.

  • @aleckofunk7564
    @aleckofunk7564 7 หลายเดือนก่อน +1

    Leaking trader core what a pain in the arse.

  • @markbeiser
    @markbeiser 2 ปีที่แล้ว +1

    Lucky Goldstar Kwality!

  • @rodgraff1782
    @rodgraff1782 ปีที่แล้ว +1

    I replaced a coil on a industrial Hyde drier for a tannery. The factory used water to pressure test the coil. Same problem with the vacuum pump oil. Had to change it about ten times. We even purged the coil with dry nitrogen before we started. I’ve had nitrogen bottles with water on the bottom. I would tip that cylinder over once it’s empty and see if water drips out. Flooded starts = cause of most compressor failures.

  • @brianpatrick678
    @brianpatrick678 2 ปีที่แล้ว +1

    I had a Trane heat pump that I worked on a bit ago that had a leak in the discharge line. I repaired the discharge line. When I evacuated it I had to change my vacuum pump oil 7 times before it had clear oil. I was beginning to think I had a leak. It was just that much moisture in the system.

  • @evaristosalazar9169
    @evaristosalazar9169 2 ปีที่แล้ว +1

    The only time I've seen that is when there was still refrigerant in the system and I was pulling a vacuum. The isolation valve was bleeding by and the oil in my pump turned white, even after changing it multiple times.

  • @AIMANNY
    @AIMANNY 2 ปีที่แล้ว +2

    What That Is Interesting. Also i love your videos

  • @zachz96
    @zachz96 2 ปีที่แล้ว +1

    Why wouldn't they be using a heat pump in Southern California?

    • @HVACRVIDEOS
      @HVACRVIDEOS  2 ปีที่แล้ว

      It comes down to our electricity costs ..... I will discuss this on my livestream this evening 12/20/21 @ 5:PM (pacific) on TH-cam come over and check it out th-cam.com/video/UKCMOJE_rmU/w-d-xo.html

  • @DanBurgaud
    @DanBurgaud 2 ปีที่แล้ว +1

    22:28 if moisture was from the old compressor, would that moisture cause freezing "inside" the low side?
    26:51 car oil pan drain plugs are also magnetic with purpose of capturing metallic bits

  • @derrickenbuenosaires
    @derrickenbuenosaires 2 ปีที่แล้ว +1

    30 degree superheat with no load, with a load on there that compressor must've been cookin ! lol it's a shame lennox didn't give the unit adjustable valves

    • @ismarcfo
      @ismarcfo 2 ปีที่แล้ว +1

      Derrick eres el mejor!

    • @ismarcfo
      @ismarcfo 2 ปีที่แล้ว +1

      Derrick sería interesante verte a tí con una tablet y viendo los mismos parámetros te facilitaría el trabajo.

  • @guygfm4243
    @guygfm4243 2 ปีที่แล้ว +7

    So true Chris if its not working out it’s because you are doing something wrong. Have had to walk away and come back to a problem and it just sorts its self out. Thanks for sharing love your videos keep on learning as I watch.

    • @mark351
      @mark351 2 ปีที่แล้ว +1

      It's also taking your mind off the problem for a while. I've solved many engineering issues by walking away for a while.

  • @rubenguzman6144
    @rubenguzman6144 2 ปีที่แล้ว +1

    Just curious why would you put in vapor only if your supposed to use liquid only to charge wouldn’t that cause fragmentation of the refrigerant or does it take lot of vapor charge to cause that ?

  • @rafaarroyo5438
    @rafaarroyo5438 18 วันที่ผ่านมา +1

    Great!!! ❤

  • @tobyoverton_hvacr
    @tobyoverton_hvacr 2 ปีที่แล้ว +1

    Those LG compressors are garbage.

  • @raulrse
    @raulrse 2 ปีที่แล้ว

    Hey man, I fix appliances for living, and I can tell you these South Korean brands LG and Samsung are the worst of the worst. Low quality materials, low quality assembly. Just very shitty manufacturers.

  • @mykabeinortas9270
    @mykabeinortas9270 2 ปีที่แล้ว +2

    Hvacr back with a amazing video

  • @Georges3DPrinters
    @Georges3DPrinters 2 ปีที่แล้ว

    Try setting your camera the manual focus cuz I think you're using a smartphone and the autofocus is messing with you

  • @newstart49
    @newstart49 2 ปีที่แล้ว

    The manufacturer of the system or LG would be paying for that job in full (Moisture related- just over a year old). I won't buy equipment with LG compressors.
    Your nitrogen was fine. You don't get moisture in a hermetically sealed system because of flooded starts.

  • @williambrennan5701
    @williambrennan5701 2 ปีที่แล้ว

    I may have a possible explanation.. The nitrogen tanks had loads of water in them . How that happens .... well.... When I worked at a prison ( as an employee) they had equipment but as far as supplies, forget it . So we would end up using refrigerant for leak checks . they kept us in refrigerant cause the office people system leaked and they were not about to sweat.. Well one day I got the idea instead of breaking federal law how about we use the recovery machine and pump air into the nitrogen tanks . We could get 500psi that way if we used three tanks we could pressure test a big system. This took forever but all you had in prison is time and inmates carried the tanks so whatever . Yes this would introduce moisture but I figured if we vacuumed it long enough we would get it back out .. we did this for a year. Well finally new budget and we actually got approved for some nitrogen tank swaps. The guy hands us the new tanks and I have the old ones up. the new tanks definitely weighed less than the ones we were turning in. Years later I talked to someone that refills those tanks and he said if they still had pressure he would just refill it and send it back out. You may have got a tank like that . I really tried to keep the crap running . when I got there they didn't even have recovery tanks, I made a bunch out of old catch cans I scavenged from the corrections junk area. I get this seems like it's a bunch of bull , but here is an unlisted video I have inside of my workshop ,outside of the prison fence , where I cobbled together a system using a two ton r22 240v window unit compressor ,a 410a mini split condenser and a R22 two ton air handler . Best I could get was an 18 degree split when I installed it but I installed it in 2018 and last I heard it still works today in the shake down room for when inmates have to strip search when they get in from work ,now it's 75 to 80 instead of 100 to 110 in there ... this is prison ingenuity th-cam.com/video/De_LYXMQneM/w-d-xo.html

  • @bentlikeitsmaker
    @bentlikeitsmaker 2 ปีที่แล้ว +1

    Spot welds if the tips wear down you may not get good fusion with every weld epically if the tips start getting too wide

  • @bryanharayda1975
    @bryanharayda1975 2 ปีที่แล้ว +3

    Just a heads up for you and your viewers, most recovery bottles have some numbers stamped into or around the handle, the TW is the tare weight and WC is the weight content, so no need to weigh an empty tank prior to recovery

    • @jonnymac31
      @jonnymac31 2 ปีที่แล้ว +3

      WC is water capacity

    • @jfbeam
      @jfbeam 2 ปีที่แล้ว +4

      When ounces (grams) matter, you weight the tank. It's a simple 3s process. Just like pushing the "zero" on the scale.

    • @HVACRVIDEOS
      @HVACRVIDEOS  2 ปีที่แล้ว

      I will discuss this on my live stream this evening on TH-cam 11/29/21 @ 5:PM (pacific) come over and check it out th-cam.com/video/jaqX-Q3oC84/w-d-xo.html

    • @bryanharayda1975
      @bryanharayda1975 2 ปีที่แล้ว

      Nice, all this time I was calculating 80% of the WC to determine how full I can fill a bottle. I didn’t know it meant water capacity, good to know. Thanks!

    • @jonnymac31
      @jonnymac31 2 ปีที่แล้ว

      @@bryanharayda1975hell yeah man. HVAC school has some info on using WC and specific gravity to determine fill. They have a nice calculator too on the app.

  • @petershepherd6889
    @petershepherd6889 2 ปีที่แล้ว

    Went to comission a water chiller and found no water flow switch was installed.Advised customer that it was imperative that a water flow switch should be fitted and he said it wasn't needed as the chiller was interlocked with the chilled water pump and wouldn't run without the pump running.
    Few weeks later got called to site as the chiller wasn't running and found the whole system was empty of gas and full of water.
    Had to fit a new water chiller as evaporator was split and compressor was stuffed.Two weeks spent purging with nitrogen and continually evacuating the system until the system was dry.
    Guess what,customer asked for a flow switch to be fitted.

  • @Yourengineeringstandpt
    @Yourengineeringstandpt 2 ปีที่แล้ว

    Why wouldn't you change out compressor, and dryer after evac, blow out with nitrogen... Where the he'll did the water come from that's alot of water

  • @arotechmechanicalhvacr1158
    @arotechmechanicalhvacr1158 2 ปีที่แล้ว

    It failed cause LG compressors are junk Trane had a bunch of issues with them now a lot of manufacturers are using them also they don’t come close to the quality of copelands scroll!

  • @joshstevens9826
    @joshstevens9826 ปีที่แล้ว

    Quicker to break with nitro when there is moisture in the system. I work on a lot of water cooled chillers. Triple evac is standard. Actually quicker to break with nitro

  • @ryancomeau8616
    @ryancomeau8616 2 ปีที่แล้ว

    I believe you're right but I don't know where you live but in Canada the freeze stat sets a code all the time especially with an economizer

  • @davidberger4726
    @davidberger4726 ปีที่แล้ว

    Lots of water ------- Sometimes somebody will mess with you. If you know what I mean!

  • @gabrielchiu2650
    @gabrielchiu2650 ปีที่แล้ว

    why is there random walk in freezer/cooler equipment? when you were cutting the compresser?

  • @Elektrotechniker
    @Elektrotechniker 2 ปีที่แล้ว

    15:17 What happened to your wrist mate? Looks like a 2-3rd degree burn!

  • @knockitofff
    @knockitofff 2 ปีที่แล้ว

    What about smell? That much moisture should be easily identified by the acidic smell

  • @weini1923
    @weini1923 ปีที่แล้ว

    Are moisture contamination from refrigerants and oils over heated to spoiled ?

  • @alimuh007
    @alimuh007 2 ปีที่แล้ว +1

    Big picture diagnosis, that's interesting