Unifi Install and Cable Management

แชร์
ฝัง
  • เผยแพร่เมื่อ 22 ส.ค. 2024

ความคิดเห็น • 174

  • @johnsonger4613
    @johnsonger4613 2 ปีที่แล้ว +11

    Ahh... What joy it would be to work for a company that supplies the right length and color of patches & jacks to make the rack look nice and planned...

  • @thattechiedazzy1662
    @thattechiedazzy1662 2 ปีที่แล้ว +8

    Love this kinda presentation. Different colors for cameras, data and AP. And nice loop near the cabinet. Look forward to part 2, Keep up the good work and vids.

  • @ChristopherOdd
    @ChristopherOdd 2 ปีที่แล้ว +7

    I think this is my favourite style of video you make right now. Love it. Keep it up bro.

    • @MactelecomNetworks
      @MactelecomNetworks  2 ปีที่แล้ว

      I love on the job videos I wish more people in my space would make them but it takes so damn long. Especially when you’re trying to get the job finished

    • @fs483
      @fs483 2 ปีที่แล้ว

      @@MactelecomNetworks I though of also doing install videos but like you said time is money and I mostly work alone. Setting up camera and talking while working is just too time consuming. I do both tech support, design and install both hardware and software alone. Adding recording is just way too much! Just want to get in and out quickly! Also question of privacy issues. My customers are not too keen on having their setups being visible. I myself don't like my private stuff on the web.

    • @MactelecomNetworks
      @MactelecomNetworks  2 ปีที่แล้ว

      It does take a lot longer but thats what the people want to see. As for the privacy thing I ALWAYS get permission from the customer. If they do not want their site filmed we don't

  • @fs483
    @fs483 2 ปีที่แล้ว +6

    Nice install. I would put 2 ciment blocks under the rack just to keep it off the floor. Also might put a sheet of foam between the blocks and the rack to reduce the chance of rust. You can pretty much put any type of thin foam. Contractors usually have some lying around when they put wood 2x4 directly on concrete. Love that Megapro screw driver! I've had mines since 2003 when I started my IT Consulting company and still have it today. I carry that screw driver with me wherever I go (except when I take the plane)! Only issue I had with it is after 19 years of use, 2 of the clips that hold the spare bits are loose so when I open it, they fall out. Very durable, still have all the bits and none of them are worn down but of course I don't abuse my tools! Also added the red one a few years ago that has the security bits. Practical when you need to open up security panels or remove screws from other brand cameras.

    • @MactelecomNetworks
      @MactelecomNetworks  2 ปีที่แล้ว +3

      Great suggestion. We are probably getting another rack so we can wallmount just waiting on confirmation from the client.
      Will be more work but worth it in the end

    • @randyvanfossan1975
      @randyvanfossan1975 2 ปีที่แล้ว

      Yes, I would be worried that the basement may flood at least partially. So a wall mount seems preferable or at the very least, up on blocks.

    • @normbugera2338
      @normbugera2338 2 ปีที่แล้ว

      @@MactelecomNetworks You might want to just build a shelf onto the wall at about 3-4 feet off the floor. Nice sheet of laminated wood with a couple of triangular brackets under the shelf for support. A local Home Depot will have what you need. Set the rack and bolt it to the shelf so it stays to the shelf. This gets everything off the floor, keeps the equipment from becoming a dust vacuum and allows for working and viewing at eye level. Nice work on the patch panel layout for the short jumpers. I've been doing that for years and pretty much perfected the layout. Cheers!

    • @will1498
      @will1498 2 ปีที่แล้ว

      and leave room for the heat to vent. im assuming out the back

  • @phillukk
    @phillukk 2 ปีที่แล้ว +2

    I really enjoyed this one! I appreciate how you use patch panels to help with the cable mgmt! Looks awesome! 👀

  • @jfkastner
    @jfkastner 2 ปีที่แล้ว +2

    Well done, thank for the video! IMHO I would not put the UDM in the bottom - there are sewage pipes and a water heater, so IF you get a leak the floor might get messy incl the UDM ... or a rainstorm etc - get things OFF the floor as high as possible

    • @MactelecomNetworks
      @MactelecomNetworks  2 ปีที่แล้ว +2

      The UnVR was just on the bottom temporarily for weight. We are actually switching this rack out with a wall mount so it’s off the floor :)
      Thanks for watching

  • @ACAIDC
    @ACAIDC 2 ปีที่แล้ว +3

    Looks great! Nice clean setup! I really like those patch cables. They're not something I've used myself, but I might have to switch over to them.
    The only thing I would change is the rack. I prefer equipment to be in an enclosed rack to prevent damage or tampering to anything.

  • @Mo_Klonus
    @Mo_Klonus 2 ปีที่แล้ว

    I saw the picture of this on Reddit yesterday, started watching video and was thinking, "Man this looks familiar" Had to go back and check Reddit! Nice job.

  • @samoacryptogeekz2965
    @samoacryptogeekz2965 ปีที่แล้ว

    Those 6 Inch Slim Patch Cables are just too cute haha

  • @robertreeder2471
    @robertreeder2471 2 ปีที่แล้ว

    I have learned a lot from watching your videos. I am working on getting a Unifi network setup in my house. Keep up the Awesome work man!!

  • @TheTechnoBoyTobi
    @TheTechnoBoyTobi 2 ปีที่แล้ว

    These types of video's satisfy my inner OCD. I like watching them while working :)
    Keep it up dude!

  • @thefluentone
    @thefluentone 2 ปีที่แล้ว +1

    Thanks, I love these! implementation vs concept and your whole process.thanks so much as a nerd.

  • @GSP-76
    @GSP-76 2 ปีที่แล้ว

    Nice setup...I did something similar but without the cameras in a daycare. It was a wonderful experience setting up Ubiquiti equipment.

  • @pitsnipe5559
    @pitsnipe5559 2 ปีที่แล้ว +1

    Nice work! Really enjoy these job site videos.

  • @bobbytaylor3177
    @bobbytaylor3177 2 ปีที่แล้ว

    Nice install. Wish you lived closer I would get you to help with an install at my house

  • @JasonsLabVideos
    @JasonsLabVideos 2 ปีที่แล้ว +1

    Looking Good Cody ! Nice work !

  • @DJaquithFL
    @DJaquithFL 2 ปีที่แล้ว

    Glad to see you seem to be doing well, bravo. What blew my mind though is a network rack sitting on the concrete floor in a basement? I'd have it mounted up on the wall eye level so I didn't have to stoop over constantly.
    Personally I don't even want my rack sitting directly on the floor in my office with a wood floor; wheels or feet are fine.
    Anyway, take care. Hope all is well!

    • @MactelecomNetworks
      @MactelecomNetworks  2 ปีที่แล้ว

      Hey ,
      Yup doing well. The client bought this rack. We changed it out yesterday for a walk mount

  • @mainerdiy8399
    @mainerdiy8399 ปีที่แล้ว

    That is a very clean install.

  • @JoeRKsChannel
    @JoeRKsChannel 2 ปีที่แล้ว +2

    Is there any reason why you looped in and out of the top switch opposed to running each network cable from the UDM?

    • @MactelecomNetworks
      @MactelecomNetworks  2 ปีที่แล้ว +1

      Back plane of the UDM pro ethernet ports is only 1gb we’re adding an aggregation switch to this anyways

  • @aliazimi91
    @aliazimi91 2 ปีที่แล้ว +16

    Hey man, awesome install. I've got a question.. How do you know which cable goes to which devices or wall jack when you get to the labelling? Do you just power on everything, and see what unify says? Do you then rearrange the cables to match the camera keystones, and ect? thanks for all the work you put into this channel my dude!

    • @MactelecomNetworks
      @MactelecomNetworks  2 ปีที่แล้ว +28

      Hey,
      Good question I have a floor plan with all the data numbers on it and in the patch panel the data drops are blue so I just count up 1,2,3 etc maybe I’ll do a video on testing and labelling

    • @aliazimi91
      @aliazimi91 2 ปีที่แล้ว +11

      @@MactelecomNetworks that would be super awesome if you could make that video.. something that shows how the labelling, and the planning for cables goes for organizational purposes, cus i couldn't imagine running all this cable, to feed into the rack and not knowing which cable went where lol thanks again my dude!

    • @phillukk
      @phillukk 2 ปีที่แล้ว +4

      Good question! Definitely helpful and great video idea!

    • @johnney87
      @johnney87 2 ปีที่แล้ว +3

      @@aliazimi91 Its not so much remembering where each cable goes when running it. Lets say we pull 50 drops to a rack, I may or may not choose to label each wire as I am running it but most of the time I end up not doing that since in my experience I have to test each drop anyhow so we are doing twice the work. We run the cable, terminate both ends, tone from the wall plate to the rack, find it with a Fox and hound tool, label and test the pairs, and the map of the building/drops is made during that process. Then we can sort out the wires and group them together by room and separate the POE from the normal.
      Edit: Also we use color coding/type of wire if we have multiple systems, Cat 6+ Blue for Network, Cat 6+ White for Cameras, White Cat 5e for Phone.

    • @cg4528
      @cg4528 2 ปีที่แล้ว +2

      Label each cable as you pull. Pull a room in order. I like to pull the furthest away from the rack first unless the client provides a map. Room outlets are run clockwise and ascend in number. Also saves cable as you pull the shortest runs last and can see on the boxes how much is left before you start, avoiding waste and short runs.
      For large installations, we mark up the floor plan, and then leave a copy with the test results for the customer. all these take seconds on a job, more then saving time as no toning needed. Large firms with multiple comms locations and cabinets, really value this approach and the IT guys always thank us for the ease of finding outlets.

  • @gungunindragunawan4189
    @gungunindragunawan4189 2 ปีที่แล้ว +1

    So nice and clean

  • @ronm6585
    @ronm6585 2 ปีที่แล้ว

    Good stuff, thanks for sharing. Looks good.

  • @matheaumichalak7537
    @matheaumichalak7537 2 ปีที่แล้ว +1

    Why is the rack not wall-mounted, up off the floor?

  • @ChristopherOdd
    @ChristopherOdd 2 ปีที่แล้ว

    Nice Dexter comics dude!

  • @cg4528
    @cg4528 2 ปีที่แล้ว +1

    Great looking rack.
    Never understood not labelling cables during a pull, takes seconds with a sharpe and saves hours of work. If a cable gets damaged during pulling or by another trade it won’t tone. I’m in the UK and I would always expect a new install to go in order left to right from the door for each room.
    It doesn’t take any longer to install, no toning needed, just test and I can label the outlets professionally, it makes finding outlets instant for customers. Also not uncommon to mark outlets on a map attached to the rack. Running 300+ outlets in a office is not uncommon, not toning that out.
    Cannot ever understand having say port 17 and 3 on the same wall plate. That’s just crazy!!

    • @MactelecomNetworks
      @MactelecomNetworks  2 ปีที่แล้ว

      All the cables are labelled I jsut haven’t labelled the front of the patch panels which will be done tomorrow.
      Also have a floor plan with all the numbers I did mention that labelling would be done on the next visit :)

    • @cg4528
      @cg4528 2 ปีที่แล้ว

      @@MactelecomNetworks Can’t fault a professional install, like this!
      Was more of a comment over what I’ve experienced. Seen the good, the bad and the ugly countless times over the years!

    • @MactelecomNetworks
      @MactelecomNetworks  2 ปีที่แล้ว

      @@cg4528 I figured as much. Labelling is essential

  • @ryderholland
    @ryderholland 2 ปีที่แล้ว +1

    Please fix that 1st ap. Just put one of the screw holes over the giant hole and screw in the other 3. Don't leave a gaping hole in the ceiling.

    • @MactelecomNetworks
      @MactelecomNetworks  2 ปีที่แล้ว

      It’s patched by the dry waller

    • @ryderholland
      @ryderholland 2 ปีที่แล้ว

      @@MactelecomNetworks Glad to hear that 👍, keep up the great videos

  • @Deraco1
    @Deraco1 2 ปีที่แล้ว

    Looks good Cody!

  • @cct241292
    @cct241292 2 ปีที่แล้ว

    I just realized, last year, I installed a new CCTV network for the company not that small.
    1UDM Pro/2UNVR/1 XG16/7 USW or USW Pro/68 G3nG4 Cam/ 16 Door Access.
    I Install all of it in 25 days with the other 2 helpers.(7/F Concrete building

  • @missinglink7709
    @missinglink7709 2 ปีที่แล้ว

    You should fan them out in some kind of order left to right brfore bundling them. So they fan out better when terminated a service loop should not be a circle.

  • @Catge
    @Catge 2 ปีที่แล้ว

    Enjoyed the video thank you

  • @Hola-ri9lz
    @Hola-ri9lz 2 ปีที่แล้ว +2

    Do you find it is always best to use a DAC between the UDM pro and switches?

  • @juansaydeflores890
    @juansaydeflores890 ปีที่แล้ว

    30yr network tech here.. you have a lot of PRIDE in your work.. most techs in my area do not!

  • @ashton.scott787
    @ashton.scott787 3 หลายเดือนก่อน

    i love how tidy all of the work is but how do you know what cable is what when placing it into the patch pannel do you label the cable?

  • @mkueffler
    @mkueffler 2 ปีที่แล้ว +3

    quick question, why not connect each switch from the UDM, instead of going from UDM to a switch, and then from that switch to another switch?

    • @marinemerchant
      @marinemerchant 10 หลายเดือนก่อน

      The top SW is at full RJ45 port density (24 ports used). The UDMP FW only has one SFP port for LAN and one for WAN(2); one rj45 WAN(1). You can reconfigure WAN for LAN I think, but I always prefer 2 WAN for failover internet even if not used immediately.

  • @halimrahmouni2530
    @halimrahmouni2530 2 ปีที่แล้ว

    Nice,

  • @justinbrooks9566
    @justinbrooks9566 2 ปีที่แล้ว

    Ubiquiti in a business RIPPPPP

  • @hawairan
    @hawairan 2 ปีที่แล้ว

    Ehm.. check panduit cbot24k cable organizing kit, or you can make it yourself. nice work btw!

  • @cpvlk
    @cpvlk ปีที่แล้ว

    hey man! i love ALL your videos! awesome work! QUESTION. WHICH PATCH PANELS ARE YOU REGULARLY USING FOR JOBS NOW? and are you still using the same VC keystones and monoprice / InstallerParts CAT6A patch cables? it has been a year to two ... you still loving them? thanks!

  • @NYphenom73
    @NYphenom73 2 ปีที่แล้ว

    This video made my OCD very happy. How do you plan on connecting the NVR to the rest of the system?

    • @MactelecomNetworks
      @MactelecomNetworks  2 ปีที่แล้ว +1

      The NvR will be plugged in using a DAC cable. We’re going to add a aggregation switch and also changing out the rack to be wall mounted

  • @turcoscorner
    @turcoscorner 2 ปีที่แล้ว

    Nice work Cody! Strange rack though!

    • @MactelecomNetworks
      @MactelecomNetworks  2 ปีที่แล้ว +3

      Right! We may be changing it to a wall mount

    • @turcoscorner
      @turcoscorner 2 ปีที่แล้ว

      @@MactelecomNetworks Very nice! Congrats!

  • @SpiffingPepe
    @SpiffingPepe 2 ปีที่แล้ว

    Nice install! The only thing i don't like is the UNVR's design, the ports for connecting it are at the back and it has no screen.

    • @MactelecomNetworks
      @MactelecomNetworks  2 ปีที่แล้ว +1

      The UNVR Pro has the SFP+ and ethernet interface at the front I wish the normal UNVR had the same

  • @P2Feener305
    @P2Feener305 2 ปีที่แล้ว

    Ruckus blows UniFi out the water.

  • @alingondrozario
    @alingondrozario 2 ปีที่แล้ว +1

    Hello there, can I ask why do all the CAT 6 Ethernet cables need to be on the patch panel before plugging in on the switch? Can they be directly plugged into the switch without needing any patch panel? Can you please explain, I don't understand.

    • @MactelecomNetworks
      @MactelecomNetworks  2 ปีที่แล้ว +2

      Well the main reason cable management it would look not so nice if you just put rj45 end on and connect directly to the switch. Also the cables are certified end to end. If the cabling goes bad it will typically be the patch cable which can easily be replace instead of having to go back to the job site and re-crimp an end on

    • @alingondrozario
      @alingondrozario 2 ปีที่แล้ว

      @@MactelecomNetworks Oh, now I got it. Thank you so much. Have a great day! 😊

  • @katlegobopape9760
    @katlegobopape9760 2 ปีที่แล้ว +1

    Great video🤙however I do have a question. Why did you use only 2 DAC cables- is it not best practice to use at-least 2 interfaces for each of those links between the switches and the router for redundancy? (link aggregation ) on most vendors STP is enabled by default.

    • @MactelecomNetworks
      @MactelecomNetworks  2 ปีที่แล้ว +2

      You can do that yup,this install still is not finished we are most likely adding another POE switch and an aggregation switch. I’ll update when it’s completed

  • @joshlemons3662
    @joshlemons3662 2 ปีที่แล้ว

    So you’re the reason everything is out of stock! 🤣

  • @Red1Wollip
    @Red1Wollip 2 ปีที่แล้ว

    Great video!!

  • @withcookies
    @withcookies 2 ปีที่แล้ว

    Awesome Video. You mentioned at the end you went with a USW-PRO because you plan on setting up a ui access controller... Why do you need a pro switch for that? For the L3 capabilities? P.S. off topic - Noticed your Dexter stuff in the background. Did you hate the ending of new blood?

    • @MactelecomNetworks
      @MactelecomNetworks  2 ปีที่แล้ว

      Hey so we need the pro because it has PoE++ to power the Unifi access hub.
      I actually was ok with the dexter ending was a lot better than the original ending lol

  • @El3andro
    @El3andro 2 ปีที่แล้ว

    Nice video and clean rack and cable management! How are you crimping the keystone modules with the cables?

    • @MactelecomNetworks
      @MactelecomNetworks  2 ปีที่แล้ว

      For the keystones I use the vertical cable ipunch tool there is a link in the description for it

  • @sachavez100
    @sachavez100 2 ปีที่แล้ว +1

    Nice deployment. Too bad I cannot procure a single camera for my system.

    • @MactelecomNetworks
      @MactelecomNetworks  2 ปีที่แล้ว

      Ya stock shortages are a pain. The customer bought all this gear months ago

  • @t3hnaku
    @t3hnaku 2 ปีที่แล้ว +1

    Where do you find so much Unifi in stock?
    I’ve been on the wait list for weeks

    • @MactelecomNetworks
      @MactelecomNetworks  2 ปีที่แล้ว

      The customer had bought all of the gear months ago

  • @powerup350
    @powerup350 ปีที่แล้ว

    I did not see a link for the white DAC cables?

  • @blessdstry
    @blessdstry ปีที่แล้ว

    Why not mount the AP over the hole. Just pop a small hole in the plastic holder. Would look much better

  • @ryoohk
    @ryoohk 2 ปีที่แล้ว

    Looks nice but to me only using half of a 24 port patch panel is wasteful, I know I know it's so the cables look clean because of how the ports are layers out on the UniFi switches but you can still use a full patch and make it look nice.

    • @MactelecomNetworks
      @MactelecomNetworks  2 ปีที่แล้ว

      Yup I get it. I only had 6 inch patch cables anyways so if I filled the patch panel the cables wouldn’t reach

  • @tmillerau
    @tmillerau 2 ปีที่แล้ว

    The first access point seems with your placement, you didn't cover up the cut-out

  • @AnthonyWebb7
    @AnthonyWebb7 ปีที่แล้ว

    Curious why 2 x 24 port switches instead of one 48?

  • @jasonperry6046
    @jasonperry6046 2 ปีที่แล้ว +1

    Have you tried ubiquiti's cable? do you have a link to the cables you typically order from Infinate cables?

    • @MactelecomNetworks
      @MactelecomNetworks  2 ปีที่แล้ว +1

      yup I have I like them for patching in devices as you can bend the boot but I don't use them on the patch panel side
      www.infinitecables.com/cat5e-cat6-cat6a-cat8/cat6-patch-cables/ultra-thin-patch-cables/rj45-cat6-utp-ultra-thin-patch-cable-premium-fluke-patch-cable-certified-cmr-riser-rated/?variation_id=10577

    • @jasonperry6046
      @jasonperry6046 2 ปีที่แล้ว

      @@MactelecomNetworks what about for bulk cable? I look at the price Ubiquiti is selling a box for and the price infinite cable is selling a box for and I wonder what the difference is.

  • @DaveShrivastav
    @DaveShrivastav 2 ปีที่แล้ว

    Looks good. I'm working on a project where switches are 300ft away. Are there DAC cables that long? Or would I need to just buy sfp port insert and use cat6?

    • @PoisonWaffle3
      @PoisonWaffle3 2 ปีที่แล้ว +1

      DAC is meant for in-rack cabling. You'll want to use Cat6 or fiber depending on your speed, distance, and RF requirements. If It's 300ft of cable, 1Gbit is plenty, and you're not running next to mains wiring, then Cat6 is probably good.

    • @DaveShrivastav
      @DaveShrivastav 2 ปีที่แล้ว

      @@PoisonWaffle3 Thanks Scott. That's what I'll do. And I found the Unifi CAT SFP adapter so that will work perfect.

  • @justintemp
    @justintemp 2 ปีที่แล้ว

    At the start there are a lot of cameras close to each other. Is a single one not sufficient as it has a long field of view?

  • @dawidlelito
    @dawidlelito 2 ปีที่แล้ว

    good job :)

  • @shakabrainfinite
    @shakabrainfinite 2 ปีที่แล้ว

    Why did you pick the phone system you did? Would UniFi talk work just as well? Or would it fall short in certain areas?

    • @MactelecomNetworks
      @MactelecomNetworks  2 ปีที่แล้ว +1

      I've used Grand stream quiet a few times and it works well and not over complicated to configure. Currently Unifi Talk is not available in Canada so its really hard to get the phones. If it were available I may have went with it

  • @quantumuninstall
    @quantumuninstall 2 ปีที่แล้ว

    On the first AP why not just offset the mount over the hole a little bit? It would have hid the blemish completely.

    • @MactelecomNetworks
      @MactelecomNetworks  2 ปีที่แล้ว

      It has been patched by the drywaller.

    • @quantumuninstall
      @quantumuninstall 2 ปีที่แล้ว

      @@MactelecomNetworks The correct approach is always the best ;)

  • @jordivanselm3201
    @jordivanselm3201 ปีที่แล้ว

    7:15 I would have put in 3 screws and let the plastic mount overlap the giant hole. Now you are left with a ugly hole

  • @DyraCaptain
    @DyraCaptain 2 ปีที่แล้ว

    Hi! Super works. My question is: Why do not you label the cables to see which is which?

    • @MactelecomNetworks
      @MactelecomNetworks  2 ปีที่แล้ว

      We do label the cables. In the video I had said we were not done yet. I’m actually going back today to finish up

    • @DyraCaptain
      @DyraCaptain 2 ปีที่แล้ว

      @@MactelecomNetworks Thank you! Sorry my English is not the better! I learn a lot from your videos.

  • @ZEK1NRZ
    @ZEK1NRZ 2 ปีที่แล้ว

    how do you tell which of the cables are for cameras and which are for data drops?

  • @DaveShrivastav
    @DaveShrivastav 2 ปีที่แล้ว

    What UPS did you end up using?

  • @emanuelroman6137
    @emanuelroman6137 2 ปีที่แล้ว

    Hey man, awesome work!!!
    Quick question, what kind of keystones and set of crimpers you used? I have tried different kind and still haven’t found the right ones. Thanks!!!

    • @ChristopherOdd
      @ChristopherOdd 2 ปีที่แล้ว

      He answered this question in the video.

    • @MactelecomNetworks
      @MactelecomNetworks  2 ปีที่แล้ว +1

      The tool is the vertical cable I-punch tool and the jacks are vertical cable vmax there are links in the description to them

  • @schism8286
    @schism8286 2 ปีที่แล้ว

    The partial hole where they made the AP hole too large is so cringe to me. Were the bracket mounting holes too narrow to cover that? Why did you offcenter?

    • @MactelecomNetworks
      @MactelecomNetworks  2 ปีที่แล้ว

      We were in there before the dry wall was up and had the cable center. The drywaller needs to pop the cable through the hole for us.
      As for the massive hole before the AP that was all patched up

  • @jirilazarek1929
    @jirilazarek1929 2 ปีที่แล้ว

    Hi, great job. Where did you buy white blindfold to empty patch panel? Thx

  • @Vijaythalapathy28
    @Vijaythalapathy28 2 ปีที่แล้ว

    Absolutely smashed it bro! And what screwdriver was that please?

    • @MactelecomNetworks
      @MactelecomNetworks  2 ปีที่แล้ว +1

      I’m honestly not sure I’ll find out for you

    • @Vijaythalapathy28
      @Vijaythalapathy28 2 ปีที่แล้ว

      @@MactelecomNetworks cool, thank you bro

  • @SouthernMedicRN
    @SouthernMedicRN 2 ปีที่แล้ว

    How are you getting anything from Unifi? All I get is out of stock and limits on quantity....

  • @dennisjangula6797
    @dennisjangula6797 2 ปีที่แล้ว

    Where do you buy your velco rolls from? Do you happen to have a link? Keep up the great videos

  • @world_of_food
    @world_of_food ปีที่แล้ว

    Hi Just wanted to ask, is it possible not to add a patch panel, and cut each ethernet cable so it reaches the ethernet ports of the switch and then just add ethernet connecter to cable and plug directly into switch

  • @christopheoudin3625
    @christopheoudin3625 2 ปีที่แล้ว

    Hi very good job! Nice and clean. I also install ubiquiti material and at this time is so difficulte to find some stock. Did you have same probleme?

    • @MactelecomNetworks
      @MactelecomNetworks  2 ปีที่แล้ว +1

      The customer had purchased this months ago so we were ready to install when we got there

  • @fps_purple9556
    @fps_purple9556 2 ปีที่แล้ว

    are those drops labeled, or are you going to tone them out and label at the end?

    • @MactelecomNetworks
      @MactelecomNetworks  2 ปีที่แล้ว +1

      I have a floor plan I know where they all go back to labelling will be a breeze

  • @jackshett
    @jackshett ปีที่แล้ว

    Maybe this is just me but... I would never run just 1 cable to a wall jack. You never know what will happen in the future. That doesn't mean it has to terminate to a switch, but at least be ran.

    • @MactelecomNetworks
      @MactelecomNetworks  ปีที่แล้ว

      I agree. Problem though is what the customer is willing to pay. In this case they only wanted one drop

  • @stewills9711
    @stewills9711 2 ปีที่แล้ว

    Any reason you went from switch to switch and not both off the UDM ? Surely that is just asking for trouble if the primary/data/voice switch goes down, you lose both. If you DAC off the UDM to each switch you can still keep cams/wifi up or LAN/Voice patching up independent of the other.

    • @MactelecomNetworks
      @MactelecomNetworks  2 ปีที่แล้ว +1

      Good question and you’re correct we would lose both.
      So we are going to be adding another two switches. One 16 port PoE and a aggregation switch .
      But if we lose the aggregation switch we lose all switches. It’s all about client budget and how much availability we need

  • @denimleather7071
    @denimleather7071 2 ปีที่แล้ว

    Not finding the link to the 6" patch cables you used. Thanks.

  • @fvasquezl
    @fvasquezl 2 ปีที่แล้ว

    What is the patch panel are you using?, where I buy one?

  • @besniknovaj3001
    @besniknovaj3001 2 ปีที่แล้ว

    Do you test the cables after terminating the keystones and crimping the ends? I didn’t see that and that’s something I always do.

    • @MactelecomNetworks
      @MactelecomNetworks  2 ปีที่แล้ว

      Yup I say at the end of the video I’m not done there. I label the patch panels, the back of the patch panel with cable wraps and same with the device end

  • @jeffrey8859
    @jeffrey8859 2 ปีที่แล้ว

    Question when working with this amount of cables, do you lable each cable before pulling the cable from the outlet to the patch location or how do you make sure what colour keystone to patch?

    • @MactelecomNetworks
      @MactelecomNetworks  2 ปีที่แล้ว

      I do just with a sharpie. Then when I’m done I label the patch panels, do wire wraps on both ends of the cables and face plates
      I also have a drawing with all of the labels and where they are located

    • @jeffrey8859
      @jeffrey8859 2 ปีที่แล้ว

      @@MactelecomNetworks Thanks for this quick reply, if i'am correct all cables going to the patch panel are blue, these are bundled and distributed on the two patch panels and switches. Is each cable labelled so you know where to connect the cables (blue for data/yellow for AP and purple for Camera). Or could you show this in upcoming videos? Keep up the great work!

    • @MactelecomNetworks
      @MactelecomNetworks  2 ปีที่แล้ว +3

      @@jeffrey8859 I think it will be easier to do in a follow up video I’ve had a few people ask this

  • @christophersteinbock2288
    @christophersteinbock2288 2 ปีที่แล้ว

    Hello,
    How are you keeping track of what cable is what? do you label them before routing ?

    • @MactelecomNetworks
      @MactelecomNetworks  2 ปีที่แล้ว +1

      Yup they were labelled with sharpie when I was pulling them in. I also have them labelled on a floor plan. Then the final labelling will be wire wraps behind the keystones, labels on the patch panel and then labels at the end device, faceplates

    • @christophersteinbock2288
      @christophersteinbock2288 2 ปีที่แล้ว

      @@MactelecomNetworks Thx for the reply. Are you going to make a video about how you do it, one day?

  • @Legendary_UA
    @Legendary_UA 2 ปีที่แล้ว

    Basically, what could I expect to pay for a normal Cat 6 cable run to be installed residentially? About 100 ft runs
    Thx

    • @MactelecomNetworks
      @MactelecomNetworks  2 ปีที่แล้ว

      Residential is always tricky, depends if the home is finished I would say between $150-$300 I know that a large gap but residential is always a pain

  • @blakegray9883
    @blakegray9883 2 ปีที่แล้ว

    Are you going to install a UPS?

    • @MactelecomNetworks
      @MactelecomNetworks  2 ปีที่แล้ว

      Yup it’s already installed but the job isn’t completed going back Sunday

  • @ZaimAfham
    @ZaimAfham 2 ปีที่แล้ว

    No ups?

  • @redmapleleafwanderer
    @redmapleleafwanderer 2 ปีที่แล้ว

    Waiting for the configuration

    • @MactelecomNetworks
      @MactelecomNetworks  2 ปีที่แล้ว

      Unfortunately there wont be a configuration video as this is a customer site and can not show personal data

  • @kalepost
    @kalepost 2 ปีที่แล้ว

    Nice install. I was wondering why you didn’t use a pro 48 port switch?

    • @MactelecomNetworks
      @MactelecomNetworks  2 ปีที่แล้ว +1

      At the time they were all sold out. Customer purchased all the gear months ago and the 24 ports were the only thing avaiable

  • @mikemcdonald5147
    @mikemcdonald5147 10 หลายเดือนก่อน

    everyone knows you never use blue velcro on blue cables it will stop the flow of electrons LOL :) j/k

    • @MactelecomNetworks
      @MactelecomNetworks  10 หลายเดือนก่อน

      Usually use black but its all I had lol

  • @nielstaildeman
    @nielstaildeman 2 ปีที่แล้ว

    Too bad the UDM-P only has 1 SFP+ lan port, now you have to daisy chain the switches.

    • @MactelecomNetworks
      @MactelecomNetworks  2 ปีที่แล้ว

      Yup I wish the second WAN port could be a LAN port. Could always add a aggregation switch in the mix

    • @nielstaildeman
      @nielstaildeman 2 ปีที่แล้ว

      @@MactelecomNetworks For 2 access switches that would be an expensive solution. :D Also than the aggregation switch would be the single point of failure.

  • @pepeshopping
    @pepeshopping 2 ปีที่แล้ว

    Don’t mount that rack. Electronics love the dust from the floor and water if it floods.

    • @MactelecomNetworks
      @MactelecomNetworks  2 ปีที่แล้ว

      So you must have missed in the video where I said the customer purchased this rack not myself and its not wall mountable. Either way we may be changing it out for a wall mount

    • @johnney87
      @johnney87 2 ปีที่แล้ว

      You must be new to the industry lmfao

  • @mohatokeer
    @mohatokeer 2 ปีที่แล้ว

    Hello how are you my brother
    My visa sand me your for work please

  • @Bagged_Cayman
    @Bagged_Cayman 2 ปีที่แล้ว

    7:22 How are you going to cut a big a$$ hole and not even cover it with the AP, thats lazy work...

    • @MactelecomNetworks
      @MactelecomNetworks  2 ปีที่แล้ว

      I guess you didn’t hear where I said the drywallers cut the hole 🤦‍♂️ they patched it already the day after this video

  • @pepeshopping
    @pepeshopping 2 ปีที่แล้ว

    Ah yes. The “pro” taking 4 times the time instead of using a cable comb…

    • @MactelecomNetworks
      @MactelecomNetworks  2 ปีที่แล้ว

      You do know cable combs are not good for cable lol

    • @AdamHillikerLikesRobots
      @AdamHillikerLikesRobots 2 ปีที่แล้ว +4

      Why come over here and talk shit instead of starting helpful discussion. Every post you've made could have been posited in a way to be constructive for the community instead of sounding like a jerk.

    • @johnney87
      @johnney87 2 ปีที่แล้ว

      I have done Zip Tie installation for 6 years, and I have never had a problem with my cable, his install (Velcro Straps) is how I was taught in school to do it, I like Velcro straps for sorting and managing the cable while I'm terminated it whether it be a keystone or just a Rj45 but I use zip ties for the finish.